978 resultados para Radiotherapy, Image-Guided
Resumo:
Background and purpose: We are developing a technique for highly focused vocal cord irradiation in early glottic carcinoma to optimally treat a target volume confined to a single cord. This technique, in contrast with the conventional methods, aims at sparing the healthy vocal cord. As such a technique requires sub-mm daily targeting accuracy to be effective, we investigate the accuracy achievable with on-line kV-cone beam CT (CBCT) corrections. Materials and methods: CBCT scans were obtained in 10 early glottic cancer patients in each treatment fraction. The grey value registration available in X-ray volume imaging (XVI) software (Elekta, Synergy) was applied to a volume of interest encompassing the thyroid cartilage. After application of the thus derived corrections, residue displacements with respect to the planning CT scan were measured at clearly identifiable relevant landmarks. The intra- and inter-observer variations were also measured. Results: While before correction the systematic displacements of the vocal cords were as large as 2.4 ± 3.3 mm (cranial-caudal population mean ± SD Σ), daily CBCT registration and correction reduced these values to less than 0.2 ± 0.5 mm in all directions. Random positioning errors (SD σ) were reduced to less than 1 mm. Correcting only for translations and not for rotations did not appreciably affect this accuracy. The residue random displacements partly stem from intra-observer variations (SD = 0.2-0.6 mm). Conclusion: The use of CBCT for daily image guidance in combination with standard mask fixation reduced systematic and random set-up errors of the vocal cords to <1 mm prior to the delivery of each fraction dose. Thus, this facilitates the high targeting precision required for a single vocal cord irradiation. © 2009 Elsevier Ireland Ltd. All rights reserved.
Resumo:
This document describes best practice and evidence based recommendations for the use of FDG-PET/CT for the purposes of radiotherapy target volume delineation (TVD) for curative intent treatment of non-small cell lung cancer (NSCLC). These recommendations have been written by an expert advisory group, convened by the International Atomic Energy Agency (IAEA) to facilitate a Coordinated Research Project (CRP) aiming to improve the applications of PET based radiation treatment planning (RTP) in low and middle income countries. These guidelines can be applied in routine clinical practice of radiotherapy TVD, for NSCLC patients treated with concurrent chemoradiation or radiotherapy alone, where FDG is used, and where a calibrated PET camera system equipped for RTP patient positioning is available. Recommendations are provided for PET and CT image visualization and interpretation, and for tumor delineation using planning CT with and without breathing motion compensation.
Resumo:
Image segmentation of natural scenes constitutes a major problem in machine vision. This paper presents a new proposal for the image segmentation problem which has been based on the integration of edge and region information. This approach begins by detecting the main contours of the scene which are later used to guide a concurrent set of growing processes. A previous analysis of the seed pixels permits adjustment of the homogeneity criterion to the region's characteristics during the growing process. Since the high variability of regions representing outdoor scenes makes the classical homogeneity criteria useless, a new homogeneity criterion based on clustering analysis and convex hull construction is proposed. Experimental results have proven the reliability of the proposed approach
Resumo:
La tesis se centra en la Visión por Computador y, más concretamente, en la segmentación de imágenes, la cual es una de las etapas básicas en el análisis de imágenes y consiste en la división de la imagen en un conjunto de regiones visualmente distintas y uniformes considerando su intensidad, color o textura. Se propone una estrategia basada en el uso complementario de la información de región y de frontera durante el proceso de segmentación, integración que permite paliar algunos de los problemas básicos de la segmentación tradicional. La información de frontera permite inicialmente identificar el número de regiones presentes en la imagen y colocar en el interior de cada una de ellas una semilla, con el objetivo de modelar estadísticamente las características de las regiones y definir de esta forma la información de región. Esta información, conjuntamente con la información de frontera, es utilizada en la definición de una función de energía que expresa las propiedades requeridas a la segmentación deseada: uniformidad en el interior de las regiones y contraste con las regiones vecinas en los límites. Un conjunto de regiones activas inician entonces su crecimiento, compitiendo por los píxeles de la imagen, con el objetivo de optimizar la función de energía o, en otras palabras, encontrar la segmentación que mejor se adecua a los requerimientos exprsados en dicha función. Finalmente, todo esta proceso ha sido considerado en una estructura piramidal, lo que nos permite refinar progresivamente el resultado de la segmentación y mejorar su coste computacional. La estrategia ha sido extendida al problema de segmentación de texturas, lo que implica algunas consideraciones básicas como el modelaje de las regiones a partir de un conjunto de características de textura y la extracción de la información de frontera cuando la textura es presente en la imagen. Finalmente, se ha llevado a cabo la extensión a la segmentación de imágenes teniendo en cuenta las propiedades de color y textura. En este sentido, el uso conjunto de técnicas no-paramétricas de estimación de la función de densidad para la descripción del color, y de características textuales basadas en la matriz de co-ocurrencia, ha sido propuesto para modelar adecuadamente y de forma completa las regiones de la imagen. La propuesta ha sido evaluada de forma objetiva y comparada con distintas técnicas de integración utilizando imágenes sintéticas. Además, se han incluido experimentos con imágenes reales con resultados muy positivos.
Resumo:
Objectives The purpose of this study was to evaluate the effectiveness of the acellular dermal matrix (ADM) as a membrane for guided bone regeneration (GBR), in comparison with a bioabsorbable membrane. Material and methods In seven dogs, the mandibular pre-molars were extracted. After 8 weeks, one bone defect was surgically created bilaterally and the GBR was performed. Each side was randomly assigned to the control group (CG: bioabsorbable membrane made of glycolide and lactide copolymer) or the test group (TG: ADM as a membrane). Immediately following GBR, standardized digital X-ray radiographs were taken, and were repeated at 8 and 16 weeks post-operatively. Before the GBR and euthanasia, clinical measurements of the width and thickness of the keratinized tissue (WKT and TKT, respectively) were performed. One animal was excluded from the study due to complications in the TG during wound healing; therefore, six dogs remained in the sample. The dogs were sacrificed 16 weeks following GBR, and a histomorphometric analysis was performed. Area measurements of new tissue and new bone, and linear measurements of bone height were performed. Results Post-operative healing of the CG was uneventful. In the TG membrane was exposed in two animals, and one of them was excluded from the sample. There were no statistically significant differences between the groups for any histomorphometric measurement. Clinically, both groups showed an increase in the TKT and a reduction in the WKT. Radiographically, an image suggestive of new bone formation could be observed in both groups at 8 and 16 weeks following GBR. Conclusion ADM acted as a barrier in GBR, with clinical, radiographic and histomorphometric results similar to those obtained with the bioabsorbable membrane. To cite this article:Borges GJ, Novaes AB Jr, de Moraes Grisi MF, Palioto DB, Taba M Jr, de Souza SLS. Acellular dermal matrix as a barrier in guided bone regeneration: a clinical, radiographic and histomorphometric study in dogs.Clin. Oral Impl. Res. 20, 2009; 1105-1115.
Resumo:
This paper describes an image compounding technique based on the use of different apodization functions, the evaluation of the signals phases and information from the interaction of different propagation modes of Lamb waves with defects for enhanced damage detection, resolution and contrast. A 16 elements linear array is attached to a 1 mm thickness isotropic aluminum plate with artificial defects. The array can excite the fundamental A0 and S0 modes at the frequencies of 100 kHz and 360 kHz, respectively. For each mode two synthetic aperture (SA) images with uniform and Blackman apodization and one image of Coherence Factor Map (CFM) are obtained. The specific interaction between each propagation mode and the defects and the characteristics of acoustic radiation patterns due to different apodization functions result in images with different resolution and contrast. From the phase information one of the SA images is selected at each pixel to compound the final image. The SA images are multiplied by the CFM image to improve contrast and for the dispersive A0 mode it is used a technique for dispersion compensation. There is a contrast improvement of 47.5 dB, reducing the dead zone and improving resolution and damage detection. © 2012 IEEE.
Resumo:
Object. Over the past few decades, various authors have performed open or stereotactic trigeminal nucleotractotomy for the treatment of neuropathic facial pain resistant to medical treatment. Stereotactic procedures can be performed percutaneously under local anesthesia, allowing intraoperative neurological examination as a method for target refinement. However, blind percutaneous procedures in the region of the atlantooccipital transition carry a considerably high risk of vascular injuries that may bring prohibitive neurological deficit or even death. To avoid such complications, the authors present the first clinical use of microendoscopy to assist percutaneous radiofrequency trigeminal nucleotractotomy. The aim of this article is to demonstrate intradural microendoscopic visualization of the medulla oblongata through an atlantooccipital percutaneous approach. Methods. The authors present a case of severe postherpetic facial neuralgia in a patient who underwent the procedure and had satisfactory results. Stereotactic computational image planning for targeting the spinal trigeminal tract and nucleus in the posterolateral medulla was performed, allowing for an accurate percutaneous approach. immediately before radiofrequency electrode insertion, a tine endoscope was introduced to visualize the structures in the cisterna magna. Results. Microendoscopic visualization offered clear identification of the pial surface of the medulla oblongata and its blood vessels, the arachnoid membrane, cranial nerve rootlets and their entry zone, and larger vessels such as the vertebral arteries and the branches of the posterior inferior cerebellar artery. Conclusions. The initial application of this technique suggests that percutaneous microendoscopy may be useful for particular manipulation of the medulla oblongata, increasing the safety of the procedure and likely improving its effectiveness. (DOI: 10.3171/2011.8.JNS11618)
Resumo:
Abstract: Bisphosphonate-related osteonecrosis of the jaws (BRONJ) is characterized as exposed bone in the jaws for more than 8 weeks in patients with current or previous history of therapy with bisphosphonates (BPs) and no history of radiotherapy in the head and neck. We report a case series of 7 patients with BRONJ and analyze the variations of clinical and imaging signs, correlating them with the presence or absence of bone exposure. Among the patients, 6 were women and 1 was a man, aged 42–79 years. Five of the patients were using zoledronic acid and the other 2 alendronate. The use of BPs varied from 3 to 13 years. In 5 patients, tooth extraction was the triggering event of injuries. Panoramic radiographs and computed tomography (CT) were evaluated by a radiologist blinded to the cases. There were persistent unremodeled extraction socket even several months after tooth extraction in 3 of the cases that were consistent wit CT findings that also showed areas of osteosclerosis and osteolysis. Patients were treated according to the recommendations of the AAOMS, with surgical debridement and antibiotic coverage with amoxicillin in the symptomatic patients. The follow-up of these patients ranged from 8 to 34 months, with a good response to treatment. The image findings in this case series were not specific and showed no difference between each stages of BRONJ (AAOMS, 2009). The image features were similar in presence or absence of exposed bone.
Resumo:
Purpose Physiological respiratory motion of tumors growing in the lung can be corrected with respiratory gating when treated with radiotherapy (RT). The optimal respiratory phase for beam-on may be assessed with a respiratory phase optimizer (RPO), a 4D image processing software developed with this purpose. Methods and Materials Fourteen patients with lung cancer were included in the study. Every patient underwent a 4D-CT providing ten datasets of ten phases of the respiratory cycle (0-100% of the cycle). We defined two morphological parameters for comparison of 4D-CT images in different respiratory phases: tumor-volume to lung-volume ratio and tumor-to-spinal cord distance. The RPO automatized the calculations (200 per patient) of these parameters for each phase of the respiratory cycle allowing to determine the optimal interval for RT. Results Lower lobe lung tumors not attached to the diaphragm presented with the largest motion with breathing. Maximum inspiration was considered the optimal phase for treatment in 4 patients (28.6%). In 7 patients (50%), however, the RPO showed a most favorable volumetric and spatial configuration in phases other than maximum inspiration. In 2 cases (14.4%) the RPO showed no benefit from gating. This tool was not conclusive in only one case. Conclusions The RPO software presented in this study can help to determine the optimal respiratory phase for gated RT based on a few simple morphological parameters. Easy to apply in daily routine, it may be a useful tool for selecting patients who might benefit from breathing adapted RT.
Resumo:
BACKGROUND AND PURPOSE: Daily use of conventional electronic portal imaging devices (EPID) for organ tracking is limited due to the relatively high dose required for high quality image acquisition. We studied the use of a novel dose saving acquisition mode (RadMode) allowing to take images with one monitor unit per image in prostate cancer patients undergoing intensity-modulated radiotherapy (IMRT) and tracking of implanted fiducial gold markers. PATIENTS AND METHODS: Twenty five patients underwent implantation of three fiducial gold markers prior to the planning CT. Before each treatment of a course of 37 fractions, orthogonal localization images from the antero-posterior and from the lateral direction were acquired. Portal images of both the setup procedure and the five IMRT treatment beams were analyzed. RESULTS: On average, four localization images were needed for a correct patient setup, resulting in four monitor units extra dose per fraction. The mean extra dose delivered to the patient was thereby increased by 1.2%. The procedure was precise enough to reduce the mean displacements prior to treatment to < o =0.3 mm. CONCLUSIONS: The use of a new dose saving acquisition mode enables to perform daily EPID-based prostate tracking with a cumulative extra dose of below 1 Gy. This concept is efficiently used in IMRT-treated patients, where separation of setup beams from treatment beams is mandatory.
Resumo:
PURPOSE: To describe the implementation and use of an electronic patient-referral system as an aid to the efficient referral of patients to a remote and specialized treatment center. METHODS AND MATERIALS: A system for the exchange of radiotherapy data between different commercial planning systems and a specially developed planning system for proton therapy has been developed through the use of the PAPYRUS diagnostic image standard as an intermediate format. To ensure the cooperation of the different TPS manufacturers, the number of data sets defined for transfer has been restricted to the three core data sets of CT, VOIs, and three-dimensional dose distributions. As a complement to the exchange of data, network-wide application-sharing (video-conferencing) technologies have been adopted to provide methods for the interactive discussion and assessment of treatments plans with one or more partner clinics. RESULTS: Through the use of evaluation plans based on the exchanged data, referring clinics can accurately assess the advantages offered by proton therapy on a patient-by-patient basis, while the practicality or otherwise of the proposed treatments can simultaneously be assessed by the proton therapy center. Such a system, along with the interactive capabilities provided by video-conferencing methods, has been found to be an efficient solution to the problem of patient assessment and selection at a specialized treatment center, and is a necessary first step toward the full electronic integration of such centers with their remotely situated referral centers.
Resumo:
PURPOSE Images from computed tomography (CT), combined with navigation systems, improve the outcomes of local thermal therapies that are dependent on accurate probe placement. Although the usage of CT is desired, its availability for time-consuming radiological interventions is limited. Alternatively, three-dimensional images from C-arm cone-beam CT (CBCT) can be used. The goal of this study was to evaluate the accuracy of navigated CBCT-guided needle punctures, controlled with CT scans. METHODS Five series of five navigated punctures were performed on a nonrigid phantom using a liver specific navigation system and CBCT volumetric dataset for planning and navigation. To mimic targets, five titanium screws were fixed to the phantom. Target positioning accuracy (TPECBCT) was computed from control CT scans and divided into lateral and longitudinal components. Additionally, CBCT-CT guidance accuracy was deducted by performing CBCT-to-CT image coregistration and measuring TPECBCT-CT from fused datasets. Image coregistration was evaluated using fiducial registration error (FRECBCT-CT) and target registration error (TRECBCT-CT). RESULTS Positioning accuracies in lateral directions pertaining to CBCT (TPECBCT = 2.1 ± 1.0 mm) were found to be better to those achieved from previous study using CT (TPECT = 2.3 ± 1.3 mm). Image coregistration error was 0.3 ± 0.1 mm, resulting in an average TRE of 2.1 ± 0.7 mm (N = 5 targets) and average Euclidean TPECBCT-CT of 3.1 ± 1.3 mm. CONCLUSIONS Stereotactic needle punctures might be planned and performed on volumetric CBCT images and controlled with multidetector CT with positioning accuracy higher or similar to those performed using CT scanners.
Resumo:
OBJECTIVE Angiographic C-arm CT may allow performing percutaneous stereotactic tumor ablations in the interventional radiology suite. Our purpose was to evaluate the accuracy of using C-arm CT for single and multimodality image fusions and to compare the targeting accuracy of liver lesions with the reference standard of MDCT. MATERIALS AND METHODS C-arm CT and MDCT scans were obtained of a nonrigid rapid prototyping liver phantom containing five 1-mm targets that were placed under skin-simulating deformable plastic foam. Target registration errors of image fusion were evaluated for single-modality and multimodality image fusions. A navigation system and stereotactic aiming device were used to evaluate target positioning errors on postinterventional scans with the needles in place fused with the C-arm CT or MDCT planning images. RESULTS Target registration error of the image fusion showed no significant difference (p > 0.05) between both modalities. In five series with a total of 25 punctures for each modality, the lateral target positioning error (i.e., the lateral distance between the needle tip and the planned trajectory) was similar for C-arm CT (mean [± SD], 1.6 ± 0.6 mm) and MDCT (1.82 ± .97 mm) (p = 0.33). CONCLUSION In a nonrigid liver phantom, angiographic C-arm CT may provide similar image fusion accuracy for comparison of intra- and postprocedure control images with the planning images and enables stereotactic targeting accuracy similar to that of MDCT.
Resumo:
Image-based modeling of tumor growth combines methods from cancer simulation and medical imaging. In this context, we present a novel approach to adapt a healthy brain atlas to MR images of tumor patients. In order to establish correspondence between a healthy atlas and a pathologic patient image, tumor growth modeling in combination with registration algorithms is employed. In a first step, the tumor is grown in the atlas based on a new multi-scale, multi-physics model including growth simulation from the cellular level up to the biomechanical level, accounting for cell proliferation and tissue deformations. Large-scale deformations are handled with an Eulerian approach for finite element computations, which can operate directly on the image voxel mesh. Subsequently, dense correspondence between the modified atlas and patient image is established using nonrigid registration. The method offers opportunities in atlasbased segmentation of tumor-bearing brain images as well as for improved patient-specific simulation and prognosis of tumor progression.
Resumo:
Introduction. In this era of high-tech medicine, it is becoming increasingly important to assess patient satisfaction. There are several methods to do so, but these differ greatly in terms of cost, time, and labour and external validity. The aim of this study is to describe and compare the structure and implementation of different methods to assess the satisfaction of patients in an emergency department. Methods. The structure and implementation of the different methods to assess patient satisfaction were evaluated on the basis of a 90-minute standardised interview. Results. We identified a total of six different methods in six different hospitals. The average number of patients assessed was 5012, with a range from 230 (M5) to 20 000 patients (M2). In four methods (M1, M3, M5, and M6), the questionnaire was composed by a specialised external institute. In two methods, the questionnaire was created by the hospital itself (M2, M4).The median response rate was 58.4% (range 9-97.8%). With a reminder, the response rate increased by 60% (M3). Conclusion. The ideal method to assess patient satisfaction in the emergency department setting is to use a patient-based, in-emergency department-based assessment of patient satisfaction, planned and guided by expert personnel.