997 resultados para Posterior-fossa Surgery


Relevância:

30.00% 30.00%

Publicador:

Resumo:

STUDY DESIGN Biomechanical cadaveric study. OBJECTIVE To determine whether augmentation positively influence screw stability or not. SUMMARY OF BACKGROUND DATA Implantation of pedicle screws is a common procedure in spine surgery to provide an anchorage of posterior internal fixation into vertebrae. Screw performance is highly correlated to bone quality. Therefore, polymeric cement is often injected through specifically designed perforated pedicle screws into osteoporotic bone to potentially enhance screw stability. METHODS Caudocephalic dynamic loading was applied as quasi-physiological alternative to classical pull-out tests on 16 screws implanted in osteoporotic lumbar vertebrae and 20 screws in nonosteoporotic specimen. Load was applied using 2 different configurations simulating standard and dynamic posterior stabilization devices. Screw performance was quantified by measurement of screwhead displacement during the loading cycles. To reduce the impact of bone quality and morphology, screw performance was compared for each vertebra and averaged afterward. RESULTS All screws (with or without cement) implanted in osteoporotic vertebrae showed lower performances than the ones implanted into nonosteoporotic specimen. Augmentation was negligible for screws implanted into nonosteoporotic specimen, whereas in osteoporotic vertebrae pedicle screw stability was significantly increased. For dynamic posterior stabilization system an increase of screwhead displacement was observed in comparison with standard fixation devices in both setups. CONCLUSION Augmentation enhances screw performance in patients with poor bone stock, whereas no difference is observed for patients without osteoporosis. Furthermore, dynamic stabilization systems have the possibility to fail when implanted in osteoporotic bone.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION Spinal disc herniation, lumbar spinal stenosis and spondylolisthesis are known to be leading causes of lumbar back pain. The cost of low back pain management and related operations are continuously increasing in the healthcare sector. There are many studies regarding complications after spine surgery but little is known about the factors predicting the length of stay in hospital. The purpose of this study was to identify these factors in lumbar spine surgery in order to adapt the postoperative treatment. MATERIAL AND METHODS The current study was carried out as a post hoc analysis on the basis of the German spine registry. Patients who underwent lumbar spine surgery by posterior surgical access and with posterior fusion and/or rigid stabilization, whereby procedures with dynamic stabilization were excluded. Patient characteristics were tested for association with length of stay (LOS) using bivariate and multivariate analyses. RESULTS A total of 356 patients met the inclusion criteria. The average age of all patients was 64.6 years and the mean LOS was 11.9 ± 6.0 days with a range of 2-44 days. Independent factors that were influencing LOS were increased age at the time of surgery, higher body mass index, male gender, blood transfusion of 1-2 erythrocyte concentrates and the presence of surgical complications. CONCLUSION Identification of predictive factors for prolonged LOS may allow for estimation of patient hospitalization time and for optimization of postoperative care. In individual cases this may result of a reduction in the LOS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE Recent advances in different MRI sequences have enabled direct visualization and targeting of the Globus pallidus internus (GPi) for DBS surgery. Modified Driven Equilibrium Fourier Transform (MDEFT) MRI sequences provide high spatial resolution and an excellent contrast of the basal ganglia with low distortion. In this study, we investigate if MDEFT sequences yield accurate and reliable targeting of the GPi and compare direct targeting based on MDEFT sequences with atlas-based targeting. METHODS 13 consecutive patients considered for bilateral GPi-DBS for dystonia or PD were included in this study. Preoperative targeting of the GPi was performed visually based on MDEFT sequences as well as by using standard atlas coordinates. Postoperative CT imaging was performed to calculate the location of the implanted leads as well as the active electrode(s). The coordinates of both visual and atlas based targets were compared. The stereotactic coordinates of the lead and active electrode(s) were calculated and projected on the segmented GPi. RESULTS On MDEFT sequences the GPi was well demarcated in most patients. Compared to atlas-based planning the mean target coordinates were located significantly more posterior. Subgroup analysis showed a significant difference in the lateral coordinate between dystonia (LAT = 19.33 ± 0.90) and PD patients (LAT = 20.67 ± 1.69). Projected on the segmented preoperative GPi the active contacts of the DBS electrode in both dystonia and PD patients were located in the inferior and posterior part of the structure corresponding to the motor part of the GPi. CONCLUSIONS MDEFT MRI sequences provide high spatial resolution and an excellent contrast enabling precise identification and direct visual targeting of the GPi. Compared to atlas-based targeting, it resulted in a significantly different mean location of our target. Furthermore, we observed a significant variability of the target among the PD and dystonia subpopulation suggesting accurate targeting for each individual patient.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE To enhance the diminished screw purchase in cancellous, osteoporotic bone following the fixation of posterior pelvic ring injuries by iliosacral screws an increased bone-implant contact area using modificated screws, techniques or bone cement may become necessary. The aim of the study was to identify sites within the pathway of iliosacral screws requiring modifications of the local bone or the design of instrumentations placed at this site. MATERIALS AND METHODS The breakaway torque was measured mechanically at the iliosacral joint ("ISJ"), the sacral lateral mass ("SLM") and the center of the S1 ("CS1"), at a superior and an inferior site under fluoroscopic control on five human cadaveric specimens (3 female; mean age 87 years, range: 76-99) using the DensiProbe™Spine device. RESULTS The measured median (range) breakaway torque was 0.63 Nm (0.31-2.52) at the "iliosacral joint", 0.14 Nm (0.05-1.22) at the "sacral lateral mass", 0.57 Nm (0.05-1.42) at the "S1 center." The "sacral lateral mass" breakaway torque was lower than compared to that at the "iliosacral joint" (p < .001) or "S1 center" (p < .001). The median (range) breakaway torque measured at all superior measurement points was 0.52 Nm (0.10-2.52), and 0.48 Nm (0.05-1.18) at all inferior sites. The observed difference was statistically significant (p < .05). CONCLUSIONS The lateral mass of the sacrum provides the lowest bone quality for implant anchorage. Iliosacral screws should be placed as superior as safely possible, should bridge the iliosacral joint and may allow for cement application at the lateral mass of the sacrum through perforations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the stability of Le Fort I maxillary inferior repositioning surgery in patients with a vertical maxillary deficiency at least 6 months after surgery. The electronic databases were searched to identify all articles reporting the long-term effects of one-piece maxillary inferior repositioning with rigid fixation. Methodological quality was evaluated according to 15 criteria related to study design, measurements, and statistical analysis. Two articles were identified, with a total of 22 patients. The maxilla was repositioned inferiorly from a mean 3.2 to 4.5mm in the anterior part and from a mean 0.1 to 1.8mm in the posterior part. At 6 months post-treatment, absolute relapse of a mean 1.6mm was measured for the anterior part of the maxilla and 0.3mm for the posterior part of the maxilla. The stability of maxillary inferior repositioning surgery could not be confirmed due to the small sample size, unclear diagnosis, and potential confounding factors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We read with great interest the large-scale network meta-analysis by Kowalewski et al. comparing clinical outcomes of patients undergoing coronary artery bypass grafting (CABG) operated on using minimal invasive extracorporeal circulation (MiECC) or off-pump (OPCAB) with those undergoing surgery on conventional cardiopulmonary bypass (CPB) [1]. The authors actually integrated into single study two recently published meta-analysis comparing MiECC and OPCAB with conventional CPB, respectively [2, 3] into a single study. According to the results of this study, MiECC and OPCAB are both strongly associated with improved perioperative outcomes following CABG when compared with CABG performed on conventional CPB. The authors conclude that MiECC may represent an attractive compromise between OPCAB and conventional CPB. After carefully reading the whole manuscript, it becomes evident that the role of MiECC is clearly undervalued. Detailed statistical analysis using the surface under the cumulative ranking probabilities indicated that MiECC represented the safer and more effective intervention regarding all-cause mortality and protection from myocardial infarction, cerebral stroke, postoperative atrial fibrillation and renal dysfunction when compared with OPCAB. Even though no significant statistical differences were demonstrated between MiECC and OPCAB, the superiority of MiECC is obvious by the hierarchy of treatments in the probability analysis, which ranked MiECC as the first treatment followed by OPCAB and conventional CPB. Thus, MiECC does not represent a compromise between OPCAB and conventional CPB, but an attractive dominant technique in CABG surgery. These results are consistent with the largest published meta-analysis by Anastasiadis et al. comparing MiECC versus conventional CPB including a total of 2770 patients. A significant decrease in mortality was observed when MiECC was used, which was also associated with reduced risk of postoperative myocardial infarction and neurological events [4]. Similarly, another recent meta-analysis by Benedetto et al. compared MiECC versus OPCAB and resulted in comparable outcomes between these two surgical techniques [5]. As stated in the text, superiority of MiECC observed in the current network meta-analysis, when compared with OPCAB, could be attributed to the fact that MiECC offers the potential for complete revascularization, whereas OPCAB poses a challenge for unexperienced surgeons; especially when distal marginal branches on the lateral and/or posterior wall of the heart need revascularization. This is reflected by a significantly lower number of distal anastomoses performed in OPCAB when compared with conventional CPB. Therefore, taking into consideration the literature published up to date, including the results of the current article, we advocate that MiECC should be integrated in the clinical practice guidelines as a state-of-the-art technique and become a standard practice for perfusion in coronary revascularization surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Infrared thermography (IRT) is a safe and non-invasive tool used for examining physiological functions based on skin temperature (Tsk) control. The aim of this paper was to establish the probable thermal difference between the beginning and the end of the anterior cruciate ligament (ACL) rehabilitation process after surgery. For this purpose thermograms from 25 ACL surgically operated patients (2 women, 23 men) were taken on the first and last day of a six-week rehabilitation program. A FLIR infrared camera according to the protocol established by the International Academy of Clinical Thermology (IACT). The results showed significant temperature increases in the posterior thigh area between the first and the last week of the rehabilitation process probably due to a compensatory mechanism. According to this, we can conclude that temperature of the posterior area of the injured and non-injured leg has increased from the first to the last day of the rehabilitation process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Infrared thermography (IRT) is a safe and non-invasive tool used for examining physiological functions based on skin temperature (Tsk) control. Thermograms from 25 anterior cruciate ligament (ACL) surgically operated patients (2 female, 23 male) were taken with a FLIR infrared camera according to the protocol established by the International Academy of Clinical Thermology (IACT). This work consists of 4 studies. Studies 1 and 3 were related to establish the probable thermal difference among different moments of an ACL rupture after surgery: before starting the rehabilitation (P0), at the end of rehabilitation (P1) and 18 months from the end of rehabilitation (P2). For this purpose, on the other hand, studies 2 and 4 were related to establish the skin thermal difference (Tsk) between the injured and the non-injured leg in P0, P1 and P2. Results of the first study showed significant temperature increases in the posterior thigh area between P0 and P1 probably due to a compensatory mechanism. According to this, we can conclude that temperature of the posterior area of the injured and noninjured leg has increased from the first to the last day of the rehabilitation process. In the second study we found significant temperature differences between the injured and non-injured leg in both stages of rehabilitation (p<.01). On the one hand, the temperature of the injured leg is higher in the anterior view and the temperature of the non-injured leg is higher in the posterior view. By the time the patients had recovered from the reconstruction, thermal imbalances should have not been shown between symmetrical parts, but differences seemed to be still latent.. Study 3 shows that temperatures seem to be higher after a year and a half (P2) than in P1. Study 4 shows how thermal values 18 months later seemed to be normalized between both legs. No significant differences were found between the injured leg and the noninjured leg after one year and a half of the rehabilitation process. Considering results from Study 3 and 4 we can conclude that patients seemed to have recovered from a thermal point of view. The temperature in P2 was higher but symmetrical. RESUMEN La termografía infrarroja (IRT) es una herramienta segura y no invasiva utilizada para examinar funciones fisiológicas que se basan en el control de temperatura de la piel (Tsk). Termogramas de 25 pacientes intervenidos quirúrgicamente del ligamento cruzado anterior (LCA) (2 mujeres, 23 hombres) fueron tomadas con una cámara de infrarrojos FLIR de acuerdo con el protocolo establecido por la Academia Internacional de Termología Clínica (IACT). Este trabajo consiste en 4 estudios. Los estudios 1 y 3 describen la diferencia térmica entre los diferentes momentos tras la operación del ligamento cruzado anterior: antes de comenzar la rehabilitación (P0), al final de la rehabilitación (P1) y 18 meses tras finalizar la rehabilitación (P2). Por otra parte, los estudios 2 y 4 describen la diferencia de temperatura de la piel (Tsk) entre la pierna lesionada y la pierna no lesionada en P0, P1 y P2. Los resultados del primer estudio mostraron aumentos significativos de temperatura en la zona posterior de los muslos entre P0 y P1, probablemente debido a un mecanismo de compensación. De acuerdo con esto, se puede concluir que la temperatura de la zona posterior de la pierna lesionada y no lesionada se ha incrementado desde el primero hasta el último día del proceso de rehabilitación. En el segundo estudio se encontraron diferencias significativas de temperatura entre la pierna lesionada y no lesionada en ambas etapas de la rehabilitación (p<.01). Por un lado, la temperatura de la pierna lesionada es mayor en la vista anterior. Por otro lado, la temperatura de la pierna no lesionada es mayor en la vista posterior. Una vez que los pacientes se han recuperado de todo el proceso, no deberían existir desequilibrios térmicos entre partes simétricas del cuerpo, pero las diferencias todavía estaban latentes. El tercer estudio muestra que la temperatura es más alta en P2 que en P1. El cuarto estudio muestra cómo los valores térmicos entre ambas piernas en P2 se han normalizado entre ambas piernas. No se encontraron diferencias significativas entre la pierna lesionada y la pierna no lesionada después de 18 meses tras el proceso de rehabilitación. Considerando los resultados del studio 3 y 4, podemos concluir que se ha llegado a la recuperación total desde un punto de vista térmico. La temperatura es más elevada en P2 pero simétrica.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Durante o desenvolvimento da oclusão, a instalação de maloclusões podem resultar em desarmonias dento faciais de natureza e severidade diversas, podendo provocar alterações no desenvolvimento crânio facial, dentre as estruturas envolvidas as Articulações Temporo Mandibulares (ATM), podem sofrer alguma influência, dessa forma a avaliação desta região, no aspecto morfológico e funcional, constituí tema de interesse, sempre que levados em conta os aspectos funcionais da oclusão. A relação entre a forma e a função, tanto das cabeças da mandíbula, bem como o contorno da fossa mandibular com as maloclusões ainda é controversa e não está compreendida por completo, porém a literatura sobre o assunto, demonstra correlação entre a instalação de maloclusões e modificações neste sistema, mesmo que algumas alterações não sejam de ordem estatística e em amostras de indivíduos em tenra idade, as mesmas podem comprometer o desenvolvimento adequado em indivíduos adultos ou mesmo adultos jovens. Tendo como propósito nesse estudo a avaliação das cabeças da mandíbula quanto ao volume e superficíe dos lados direito e esquerdo, cruzado e não cruzado, a amostra selecionada foi de 20 indivíduos com mordida cruzada posterior unilateral, com idades entre 06 e 09 anos de idade, utilizando imagens de tomografia computadorizada por feixe cônico, imagens obtidas por um equipamento modelo i- Cat, sendo utilizado na reformatação e manipulação das imagens o programa computacional - NemoCeph 3D® versão 11.5. Nas medições propostas para esse estudo, utilizou-se o teste t pareado de Student para amostras com distribuição normal. Na observação das tabelas e seus respectivos gráficos, podemos verificar que na comparação entre os lados direito e esquerdo, e cruzado e não cruzado das cabeças da mandíbula, com relação ao volume e superfície, existem diferenças numéricas entre elas, porém não pode ser observado diferenças estatísticas significantes, nessa amostra especifica com a metodologia empregada para esse estudo. Assim foi possível concluir que nas Mordidas Cruzadas Posteriores Unilaterais as cabeças da mandíbula tanto em seu volume como em sua superfície não apresentaram diferenças estatisticamente significantes na amostra estudada.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose To evaluate visual, optical, and quality of life (QoL) outcomes and intercorrelations after bilateral implantation of posterior chamber phakic intraocular lenses. Methods Twenty eyes with high to moderate myopia of 10 patients that underwent PRL implantation (Phakic Refractive Lens, Carl Zeiss Meditec AG) were examined. Refraction, visual acuity, photopic and low mesopic contrast sensitivity (CS) with and without glare, ocular aberrations, as well as QoL outcomes (National Eye Institute Refractive Error Quality of Life Instrument-42, NEI RQL-42) were evaluated at 12 months postoperatively. Results Significant improvement in uncorrected (UDVA) and best-corrected distance (CDVA) visual acuities were found postoperatively (p < 0.01), with significant reduction in spherical equivalent (p < 0.01). Low mesopic CS without glare was significantly better than measurements with glare for 1.5, 3, and 6 cycles/degree (p < 0.01). No significant correlations between higher order root mean square (RMS) with CDVA (r = −0.26, p = 0.27) and CS (r ≤ 0.45, p ≥ 0.05) were found. Postoperative binocular photopic CS for 12 cycles/degree and 18 cycles/degree correlated significantly with several RQL-42 scales. Glare index correlated significantly with CS measures and scotopic pupil size (r = −0.551, p = 0.04), but not with higher order RMS (r = −0.02, p = 0.94). Postoperative higher order RMS, postoperative primary coma and postoperative spherical aberration was significant higher for 5-mm pupil diameter (p < 0.01) compared with controls. Conclusions Correction of moderate to high myopia by means of PRL implantation had a positive impact on CS and QoL. The aberrometric increase induced by the surgery does not seem to limit CS and QoL. However, perception of glare is still a relevant disturbance in some cases possibly related to the limitation of the optical zone of the PRL.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Implantation of phakic intraocular lenses (pIOLs) is a reversible refractive procedure, preserving the patient’s accommodative function with minimal induction of higher order aberrations compared with corneal photoablative procedures. Despite this, as an intraocular procedure, it has potential risks such as cataracts, chronic uveitis, pupil ovalization, corneal endothelial cell loss, pigmentary dispersion syndrome, pupillary block glaucoma, astigmatism, or endophthalmitis. Currently, only two models of posterior chamber pIOLs are commercially available, the implantable collammer lens (STAAR Surgical Co.) and the phakic refractive lens (PRL; Zeiss Meditec). The number of published reports on the latter is very low, and some concerns still remain about its long-term safety. The present article reviews the published literature on the outcomes after PRL implantation in order to provide a general overview and evaluate its real potential as a surgical refractive option.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To calculate theoretically the errors in the estimation of corneal power when using the keratometric index (nk) in eyes that underwent laser refractive surgery for the correction of myopia and to define and validate clinically an algorithm for minimizing such errors. Methods: Differences between corneal power estimation by using the classical nk and by using the Gaussian equation in eyes that underwent laser myopic refractive surgery were simulated and evaluated theoretically. Additionally, an adjusted keratometric index (nkadj) model dependent on r1c was developed for minimizing these differences. The model was validated clinically by retrospectively using the data from 32 myopic eyes [range, −1.00 to −6.00 diopters (D)] that had undergone laser in situ keratomileusis using a solid-state laser platform. The agreement between Gaussian (PGaussc) and adjusted keratometric (Pkadj) corneal powers in such eyes was evaluated. Results: It was found that overestimations of corneal power up to 3.5 D were possible for nk = 1.3375 according to our simulations. The nk value to avoid the keratometric error ranged between 1.2984 and 1.3297. The following nkadj models were obtained: nkadj= −0.0064286r1c + 1.37688 (Gullstrand eye model) and nkadj = −0.0063804r1c + 1.37806 (Le Grand). The mean difference between Pkadj and PGaussc was 0.00 D, with limits of agreement of −0.45 and +0.46 D. This difference correlated significantly with the posterior corneal radius (r = −0.94, P < 0.01). Conclusions: The use of a single nk for estimating the corneal power in eyes that underwent a laser myopic refractive surgery can lead to significant errors. These errors can be minimized by using a variable nk dependent on r1c.