986 resultados para Portal Corporativo
Resumo:
To analyze the role of the murine hepatoportal glucose sensor in the control of whole-body glucose metabolism, we infused glucose at a rate corresponding to the endogenous glucose production rate through the portal vein of conscious mice (Po-mice) that were fasted for 6 h. Mice infused with glucose at the same rate through the femoral vein (Fe-mice) and mice infused with a saline solution (Sal-mice) were used as controls. In Po-mice, hypoglycemia progressively developed until glucose levels dropped to a nadir of 2.3 +/- 0.1 mmol/l, whereas in Fe-mice, glycemia rapidly and transiently developed, and glucose levels increased to 7.7 +/- 0.6 mmol/l before progressively returning to fasting glycemic levels. Plasma insulin levels were similar in both Po- and Fe-mice during and at the end of the infusion periods (21.2 +/- 2.2 vs. 25.7 +/- 0.9 microU/ml, respectively, at 180 min of infusion). The whole-body glucose turnover rate was significantly higher in Po-mice than in Fe-mice (45.9 +/- 3.8 vs. 37.7 +/- 2.0 mg x kg(-1) x min)-1), respectively) and in Sal-mice (24.4 +/- 1.8 mg x kg(-1) x min(-1)). Somatostatin co-infusion with glucose in Po-mice prevented hypoglycemia without modifying the plasma insulin profile. Finally, tissue glucose clearance, which was determined after injecting 14C-2-deoxyglucose, increased to a higher level in Po-mice versus Fe-mice in the heart, brown adipose tissue, and the soleus muscle. Our data show that stimulation of the hepatoportal glucose sensor induced hypoglycemia and increased glucose utilization by a combination of insulin-dependent and insulin-independent or -sensitizing mechanisms. Furthermore, activation of the glucose sensor and/or transmission of its signal to target tissues can be blocked by somatostatin.
Resumo:
Then, the expression of angiogenesis markers (western blotting), the formation of portosystemic collaterals (radioactive microspheres) and the production of superoxide anion (lucigenin-enhanced chemiluminescence) were determined. Mean arterial pressure, portal pressure, and superior mesenteric arterial blood flow and resistance were also measured.Results: In portal hypertensive rats, NAD(P)H oxidase blockade significantly decreased portosystemic collateral formation, and superior mesenteric arterial flow. It also reduced the splanchnic expression of VEGF, VEGF receptor-2 and CD31, and attenuated the increased production of superoxide, compared with vehicle.Conclusions: NAD(P)H oxidase plays an important role in experimental portal hypertension, modulating splanchnic angiogenesis, the formation of portosystemic collaterals and the development of splanchnic hyperdynamic circulation. These results suggest that NAD(P)H oxidase may represent a new target in the treatment of portal hypertension.
Resumo:
BACKGROUND/AIMS/METHODS During hepatic vein catheterisation, in addition to measurement of hepatic venous pressure gradient (HVPG), iodine wedged retrograde portography can be easily obtained. However, it rarely allows correct visualisation of the portal vein. Recently, CO2 has been suggested to allow better angiographic demonstration of the portal vein than iodine. In this study we investigated the efficacy of CO2 compared with iodinated contrast medium for portal vein imaging and its role in the evaluation of portal hypertension in a series of 100 patients undergoing hepatic vein catheterisation, 71 of whom had liver cirrhosis. RESULTS In the overall series, CO2 venography was markedly superior to iodine, allowing correct visualisation of the different segments of the portal venous system. In addition, CO2, but not iodine, visualised portal-systemic collaterals in 34 patients. In cirrhosis, non-visualisation of the portal vein on CO2 venography occurred in 11 cases; four had portal vein thrombosis and five had communications between different hepatic veins. Among non-cirrhotics, lack of portal vein visualisation had a 90% sensitivity, 88% specificity, 94% negative predictive value, and 83% positive predictive value in the diagnosis of pre-sinusoidal portal hypertension. CONCLUSIONS Visualisation of the venous portal system by CO2 venography is markedly superior to iodine. The use of CO2 wedged portography is a useful and safe complementary procedure during hepatic vein catheterisation which may help to detect portal thrombosis. Also, lack of demonstration of the portal vein in non-cirrhotic patients strongly suggests the presence of pre-sinusoidal portal hypertension.
Resumo:
Background: In cirrhosis, repeated flares of portal pressure and collateral blood flow provoked by postprandial hyperaemia may contribute to variceal dilation and rupture. Aim: To examine the effect of the extent of the collateral circulation on the postprandial increase in portal pressure observed in cirrhosis. Patients and methods: The hepatic venous pressure gradient (HVPG), hepatic blood flow and azygos blood flow were measured in 64 patients with cirrhosis before and after a standard liquid meal. Results: Peak increases in HVPG (median+14.9%), hepatic blood flow (median+25.4%), and azygos blood flow (median+32.2%) occurred at 30 min after the meal. Compared with patients with marked postprandial increase in HVPG (above the median, n¿=¿32), those showing mild (<15%, n¿=¿32) increase in HVPG had a higher baseline azygos flow (p<0.01) and underwent a greater postprandial increase in azygos flow (p<0.02). Hepatic blood flow increased similarly in both groups. Postprandial increases in HVPG were inversely correlated (p<0.001) with both baseline azygos flow (r¿=¿¿0.69) and its postprandial increase (r¿=¿¿0.72). Food intake increased nitric oxide products in the azygos (p<0.01), but not in the hepatic vein. Large varices (p<0.01) and previous variceal bleeding (p<0.001) were more frequent in patients with mild increase in HVPG. Conclusions: Postprandial hyperaemia simultaneously increases HVPG and collateral flow. The extent of the collateral circulation determines the HVPG response to food intake. Patients with extensive collateralisation show less pronounced postprandial increases in HVPG, but associated with marked flares in collateral flow. Collateral vessels preserve their ability to dilate in response to increased blood flow.
Resumo:
PURPOSE: To retrospectively assess the frequency of adverse events related to percutaneous preoperative portal vein embolization (PPVE). MATERIALS AND METHODS: Institutional review board did not require its approval or patient informed consent for this study. The adverse events that occurred during PPVE or until planned hepatic surgery was performed or cancelled were retrospectively obtained from clinical, imaging, and laboratory data files in 188 patients (109 male and 79 female patients; mean age, 60 years; range, 16-78 years). Liver resection was planned for metastases (n = 137), hepatocarcinoma (n = 31), cholangiocarcinoma (n = 15), fibrolamellar hepatoma (n = 1), and benign disease (n = 4). PPVE was performed with a single-lumen 5-F catheter and a contralateral approach with n-butyl cyanoacrylate mixed with iodized oil as the main embolic agent. The rate of complications in patients with cirrhosis was compared with that in patients without cirrhosis by using the chi(2) test. RESULTS: Adverse events occurred in 24 (12.8%) of 188 patients, including 12 complications and 12 incidental imaging findings. Complications included thrombosis of the portal vein feeding the future remnant liver (n = 1); migration of emboli in the portal vein feeding the future remnant liver, which necessitated angioplasty (n = 2); hemoperitoneum (n = 1); rupture of a metastasis in the gallbladder (n = 1); transitory hemobilia (n = 1); and transient liver failure (n = 6). Incidental findings were migration of small emboli in nontargeted portal branches (n = 10) and subcapsular hematoma (n = 2). Among the 187 patients in whom PPVE was technically successful, there was a significant difference (P < .001) between the occurrence of liver failure after PPVE in patients with cirrhosis (five of 30) and those without (one of 157). Sixteen liver resections were cancelled due to cancer progression (n = 12), insufficient hypertrophy of the nonembolized liver (n = 3), and complete portal thrombosis (n = 1). CONCLUSION: PPVE is a safe adjuvant technique for hypertrophy of the initially insufficient liver reserve. Post-PPVE transient liver failure is more common in patients with cirrhosis than in those without cirrhosis.
Resumo:
This article evaluates the results of portal vein (PV) stent placement in patients with malignant extrinsic lesions stenosing or obstructing the PV and causing symptomatic PV hypertension (PVHT). Fourteen patients with bile duct cancer (n = 7), pancreatic adenocarcinoma (n = 4), or another cancer (n = 3) underwent percutaneous transhepatic portal venous stent placement because of gastroesophageal or jejunal varices (n = 9), ascites (n = 7), and/or thrombocytopenia (n = 2). Concurrent tumoral obstruction of the main bile duct was treated via the transhepatic route in the same session in four patients. Changes in portal venous pressure, complications, stent patency, and survival were evaluated. Mean +/- standard deviation (SD) gradient of portal venous pressure decreased significantly immediately after stent placement from 11.2 mmHg +/- 4.6 to 1.1 mmHg +/- 1.0 (P < 0.00001). Three patients had minor complications, and one developed a liver abscess. During a mean +/- SD follow-up of 134.4 +/- 123.3 days, portal stents remained patent in 11 patients (78.6%); stent occlusion occurred in 3 patients, 2 of whom had undergone previous major hepatectomy. After stent placement, PVHT symptoms were relieved in four (57.1%) of seven patients who died (mean survival, 97 +/- 71.2 days), and relieved in six (85.7%) of seven patients still alive at the end of follow-up (mean follow-up, 171.7 +/- 153.5 days). Stent placement in the PV is feasible and relatively safe. It helped to relieve PVHT symptoms in a single session.
Resumo:
A premissa central deste artigo - parte de uma pesquisa de mestrado - é que, sendo a Internet um poderoso instrumento tecnológico para a disseminação e o acesso às informações, os governos a têm utilizado como uma forma de aproximação dos cidadãos. Buscando avaliar seu alcance efetivo, avalia-se o Portal de serviços e informações do governo brasileiro com base na metodologia de Vilella (2003), que envolve 73 critérios, agrupados em 14 parâmetros distribuídos em três dimensões: conteúdo, usabilidade e funcionalidade do portal. Como ferramenta de análise foram utilizados três tipos de software, durante período de tempo predeterminado, atribuindo-se notas a cada dimensão para avaliar seu grau de aprovação. Os resultados apontaram os pontos fortes e fracos do Portal; as notas baixas atribuídas à forma de apresentação do conteúdo, atualização e manutenção do conteúdo; equilíbrio nas notas referentes à usabilidade, ressaltando-se, porém, nesse caso, as dificuldades no acesso para pessoas portadoras de necessidades especiais.
Resumo:
Este trabalho analisa o conjunto de periódicos eletrônicos de administração disponíveis no Portal Capes, do ponto de vista dos interesses dos usuários de uma biblioteca universitária especializada no assunto. Empregou-se como método a análise das citações dos periódicos utilizados nas teses de doutorado defendidas no Programa de Pós-Graduação em Administração da Escola de Administração da Universidade Federal do Rio Grande do Sul no período 1999-2007. Observou-se que 25% dos periódicos citados nas teses não estão disponíveis no Portal e que os periódicos disponíveis apresentam limitações quanto à integralidade da coleção.