946 resultados para Poly(vinyl Alcohol) Hydrogel


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new biomimetic sensor for leucomalachite green host-guest interactions and potentiometric transduction is presented. The artificial host was imprinted in methacrylic acid or acrylamido-2-methyl-1-propanesulfonic acid-based polymers. Molecularly imprinted particles were dispersed in 2-nitrophenyloctyl ether and trapped in poly(vinyl chloride). The potentiometric sensors exhibited a near-Nernstian response in steady state evaluations, with slopes and detection limits ranging from 45.8 to 81.2 mV and 0.28 to 1.01 , respectively. They were independent from the pH of test solutions within 3 to 5. Good selectivity was observed towards drugs that may contaminate water near fish cultures, such as oxycycline, doxycycline, enrofloxacin, trimethoprim, creatinine, chloramphenicol, and dopamine. The sensors were successfully applied to field monitoring of leucomalachite green in river samples. The method offered the advantages of simplicity, accuracy, applicability to colored and turbid samples, and automation feasibility.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new man-tailored biomimetic sensor for Chlorpromazine host-guest interactions and potentiometric transduction is presented. The artificial host was imprinted within methacrylic acid, 2-vinyl pyridine and 2-acrylamido-2-methyl-1-propanesulfonic acid based polymers. Molecularly imprinted particles were dispersed in 2-nitrophenyloctyl ether and entrapped in a poly(vinyl chloride) matrix. Slopes and detection limits ranged 51–67 mV/decade and 0.46–3.9 μg/mL, respectively, in steady state conditions. Sensors were independent from the pH of test solutions within 2.0–5.5. Good selectivity was observed towards oxytetracycline, doxytetracycline, ciprofloxacin, enrofloxacin, nalidixic acid, sulfadiazine, trimethoprim, glycine, hydroxylamine, cysteine and creatinine. Analytical features in flowing media were evaluated on a double-channel manifold, with a carrier solution of 5.0 × 10−2 mol/L phosphate buffer. Near-Nernstian response was observed over the concentration range 1.0 × 10−4 to 1.0 × 10−2 mol/L. Average slopes were about 48 mV/decade. The sensors were successfully applied to field monitoring of CPZ in fish samples, offering the advantages of simplicity, accuracy, automation feasibility and applicability to complex samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A 3D-mirror synthetic receptor for ciprofloxacin host–guest interactions and potentiometric transduction is presented. The host cavity was shaped on a polymeric surface assembled with methacrylic acid or 2-vinyl pyridine monomers by radical polymerization. Molecularly imprinted particles were dispersed in 2-nitrophenyl octyl ether and entrapped in a poly(vinyl chloride) matrix. The sensors exhibited a near-Nernstian response in steady state evaluations. Slopes and detection limits ranged from 26.8 to 50.0 mV decade−1 and 1.0 × 10−5 to 2.7 × 10−5 mol L−1, respectively. Good selectivity was observed for trimethoprim, enrofloxacin, tetracycline, cysteine, galactose, hydroxylamine, creatinine, ammonium chloride, sucrose, glucose, sulphamerazine and sulfadiazine. The sensors were successfully applied to the determination of ciprofloxacin concentrations in fish and in pharmaceuticals. The method presented offered the advantages of simplicity, accuracy, applicability to colored and turbid samples and automation feasibility, as well as confirming the use of molecularly imprinted polymers as ionophores for organic ion recognition in potentiometric transduction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A biomimetic sensor for norfloxacin is presented that is based on host-guest interactions and potentiometric transduction. The artificial host was imprinted into polymers made from methacrylic acid and/or 2-vinyl pyridine. The resulting particles were entrapped in a plasticized poly(vinyl chloride) (PVC) matrix. The sensors exhibit near-Nernstian response in steady state evaluations, and detection limits range from 0.40 to 1.0 μg mL−1, respectively, and are independent of pH values at between 2 and 6, and 8 and 11, respectively. Good selectivity was observed over several potential interferents. In flowing media, the sensors exhibit fast response, a sensitivity of 68.2 mV per decade, a linear range from 79 μM to 2.5 mM, a detection limit of 20 μg mL−1, and a stable baseline. The sensors were successfully applied to field monitoring of norfloxacin in fish samples, biological samples, and pharmaceutical products.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Enrofloxacin (ENR) is an antimicrobial used both in humans and in food producing species. Its control is required in farmed species and their surroundings in order to reduce the prevalence of antibiotic resistant bacteria. Thus, a new biomimetic sensor enrofloxacin is presented. An artificial host was imprinted in specific polymers. These were dispersed in 2-nitrophenyloctyl ether and entrapped in a poly(vinyl chloride) matrix. The potentiometric sensors exhibited a near-Nernstian response. Slopes expressing mV/Δlog([ENR]/M) varied within 48–63. The detection limits ranged from 0.28 to 1.01 µg mL−1. Sensors were independent from the pH of test solutions within 4–7. Good selectivity was observed toward potassium, calcium, barium, magnesium, glycine, ascorbic acid, creatinine, norfloxacin, ciprofloxacin, and tetracycline. In flowing media, the biomimetic sensors presented good reproducibility (RSD of ± 0.7%), fast response, good sensitivity (47 mV/Δlog([ENR]/M), wide linear range (1.0 × 10−5–1.0 × 10−3 M), low detection limit (0.9 µg mL−1), and a stable baseline for a 5 × 10−2 M acetate buffer (pH 4.7) carrier. The sensors were used to analyze fish samples. The method offered the advantages of simplicity, accuracy, and automation feasibility. The sensing membrane may contribute to the development of small devices allowing in vivo measurements of enrofloxacin or parent-drugs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The indiscriminate use of antibiotics in food-producing animals has received increasing attention as a contributory factor in the international emergence of antibiotic-resistant bacteria (Woodward in Pesticide, veterinary and other residues in food, CRC Press, Boca Raton, 2004). Numerous analytical methods for quantifying antibacterial residues in edible animal products have been developed over years (Woodward in Pesticide, veterinary and other residues in food, CRC Press, Boca Raton, 2004; Botsoglou and Fletouris in Handbook of food analysis, residues and other food component analysis, Marcel Dekker, Ghent, 2004). Being Amoxicillin (AMOX) one of those critical veterinary drugs, efforts have been made to develop simple and expeditious methods for its control in food samples. In literature, only one AMOX-selective electrode has been reported so far. In that work, phosphotungstate:amoxycillinium ion exchanger was used as electroactive material (Shoukry et al. in Electroanalysis 6:914–917, 1994). Designing new materials based on molecularly imprinted polymers (MIPs) which are complementary to the size and charge of AMOX could lead to very selective interactions, thus enhancing the selectivity of the sensing unit. AMOX-selective electrodes used imprinted polymers as electroactive materials having AMOX as target molecule to design a biomimetic imprinted cavity. Poly(vinyl chloride), sensors of methacrylic acid displayed Nernstian slopes (60.7 mV/decade) and low detection limits (2.9 × 10−5 mol/L). The potentiometric responses were not affected by pH within 4–5 and showed good selectivity. The electrodes were applied successfully to the analysis of real samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents the development of a low cost sensor device for the diagnosis of breast cancer in point-of-care, made with new synthetic biomimetic materials inside plasticized poly(vinyl chloride), PVC, membranes, for subsequent potentiometric detection. This concept was applied to target a conventional biomarker in breast cancer: Breast Cancer Antigen (CA15-3). The new biomimetic material was obtained by molecularly-imprinted technology. In this, a plastic antibody was obtained by polymerizing around the biomarker that acted as an obstacle to the growth of the polymeric matrix. The imprinted polymer was specifically synthetized by electropolymerization on an FTO conductive glass, by using cyclic voltammetry, including 40 cycles within -0.2 and 1.0 V. The reaction used for the polymerization included monomer (pyrrol, 5.0×10-3 mol/L) and protein (CA15-3, 100U/mL), all prepared in phosphate buffer saline (PBS), with a pH of 7.2 and 1% of ethylene glycol. The biomarker was removed from the imprinted sites by proteolytic action of proteinase K. The biomimetic material was employed in the construction of potentiometric sensors and tested with regard to its affinity and selectivity for binding CA15-3, by checking the analytical performance of the obtained electrodes. For this purpose, the biomimetic material was dispersed in plasticized PVC membranes, including or not a lipophilic ionic additive, and applied on a solid conductive support of graphite. The analytical behaviour was evaluated in buffer and in synthetic serum, with regard to linear range, limit of detection, repeatability, and reproducibility. This antibody-like material was tested in synthetic serum, and good results were obtained. The best devices were able to detect 5 times less CA15-3 than that required in clinical use. Selectivity assays were also performed, showing that the various serum components did not interfere with this biomarker. Overall, the potentiometric-based methods showed several advantages compared to other methods reported in the literature. The analytical process was simple, providing fast responses for a reduced amount of analyte, with low cost and feasible miniaturization. It also allowed the detection of a wide range of concentrations, diminishing the required efforts in previous sample pre-treating stages.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertation toobtaina Master of Science degree in Bioorganics

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the preliminary findings of pH and colour measurements carried out on artworks on paperand on wood that had been treated with a poly(vinyl acetate) (PVAC) based adhesive in the 1980s. In both cases, areas treated with PVAC proved to be less acidic than untreated areas. Contrary to expectations, the conservation treatments have not, as yet, increased acidity levels in the objects under study. Colour measurements of the works on paper showed that those that had been backed with a cotton fabric using a mixture of methylcellulose and PVAC were less yellow than those from the same print run that had not been backed. This finding suggests that the backing somehow prevented the natural degradation of the support. In view of these preliminary results, further research is clearly needed. This study forms part of a broader ongoing project to assess the role of PVAC in the conservation of a range of cultural assets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the preliminary findings of pH and colour measurements carried out on artworks on paperand on wood that had been treated with a poly(vinyl acetate) (PVAC) based adhesive in the 1980s. In both cases, areas treated with PVAC proved to be less acidic than untreated areas. Contrary to expectations, the conservation treatments have not, as yet, increased acidity levels in the objects under study. Colour measurements of the works on paper showed that those that had been backed with a cotton fabric using a mixture of methylcellulose and PVAC were less yellow than those from the same print run that had not been backed. This finding suggests that the backing somehow prevented the natural degradation of the support. In view of these preliminary results, further research is clearly needed. This study forms part of a broader ongoing project to assess the role of PVAC in the conservation of a range of cultural assets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the preliminary findings of pH and colour measurements carried out on artworks on paperand on wood that had been treated with a poly(vinyl acetate) (PVAC) based adhesive in the 1980s. In both cases, areas treated with PVAC proved to be less acidic than untreated areas. Contrary to expectations, the conservation treatments have not, as yet, increased acidity levels in the objects under study. Colour measurements of the works on paper showed that those that had been backed with a cotton fabric using a mixture of methylcellulose and PVAC were less yellow than those from the same print run that had not been backed. This finding suggests that the backing somehow prevented the natural degradation of the support. In view of these preliminary results, further research is clearly needed. This study forms part of a broader ongoing project to assess the role of PVAC in the conservation of a range of cultural assets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the preliminary findings of pH and colour measurements carried out on artworks on paperand on wood that had been treated with a poly(vinyl acetate) (PVAC) based adhesive in the 1980s. In both cases, areas treated with PVAC proved to be less acidic than untreated areas. Contrary to expectations, the conservation treatments have not, as yet, increased acidity levels in the objects under study. Colour measurements of the works on paper showed that those that had been backed with a cotton fabric using a mixture of methylcellulose and PVAC were less yellow than those from the same print run that had not been backed. This finding suggests that the backing somehow prevented the natural degradation of the support. In view of these preliminary results, further research is clearly needed. This study forms part of a broader ongoing project to assess the role of PVAC in the conservation of a range of cultural assets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High barrier materiaaleilla pyritään pidentämään pakattujen elintarvikkeiden hyllyikää. Barrierin tärkein tehtävä on elintarvikkeen suojaaminen hapelta ja kosteudelta. Alumiinin käyttöä barriermateriaalina pyritään vähentämään korvaamalla alumiini polymeereillä, jotka täyttävät elintarvikkeiden asettamat korkeat säilyvyysvaatimukset. Etyylivinyylialkoholin (EVOH) hapenläpäisevyys on kuivissa olosuhteissa alhaisin kaupallisista muovilaaduista. EVOH tarjoaa myös erinomaisen suojan muita kaasuja, rasvoja, hajuja ja aromeja vastaan ja sitä on helppo prosessoida. Polyamideilla on erinomainen kaasutiiveys sekä hyvä lujuus ja sitkeys. Eri muovilaatuja sekoittamalla voidaan vähentää hapenläpäisyä ja parantaa prosessointia. Polyolefiineja käytetään yleisesti päällystysmateriaaleina, koska ne suojaavat tuotetta erinomaisesti kosteudelta. Hapenläpäisyllä tarkoitetaan hapen kulkeutumista materiaalin läpi joko permeaation kautta tai reikien ja vuotojen läpi. Kaasun permeoitumiseen materiaalin läpi vaikuttavat materiaalin vapaa tilavuus, kiteisyysaste, orientaatio, substituointi, suhteellinen kosteus, lämpötila, barrierkerroksen paksuus, paine-ero ja permeoituvan molekyylin ominaisuudet. Kokeellisessa osassa analysoitiin ja vertailtiin kartonkipohjaisia mehutölkkejä, joissa käytettävät high barrier materiaalit olivat EVOH ja PA. Kartonkipohjaisia alumiinitölkkejä käytettiin referenssinä. Pakkausten hapenläpäisevyysmittauksissa saatiin samasta näytteestä toistettavia tuloksia, vaikka vuotomittauksissa saadut tulokset eivät olleet vertailukelpoisia hapenläpäisytulosten kanssa. Tölkkien valmistus vaikutti oleellisesti pakkausten tiiveysominaisuuksiin. Hapenläpäisy vuotojen ja reikien läpi oli merkittävämpää kuin hapenläpäisy materiaalin läpi. Pakkausten tiiveysominaisuuksia analysoitiin mittaamalla appelsiinimehun askorbiini-happopitoisuus. Askorbiinihapon hajoaminen mitattiin koetölkkeihin pakatusta appelsiinimehusta, ja lämpötilan, valon ja hapen vaikutusta askorbiinihapon hajoamiseen tutkittiin 12 viikon ajan. Lämpötilalla oli suurin vaikutus askorbiinihapon hajoamiseen huolimatta käytetystä pakkausmateriaalista.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work we take advantage of the polyelectrolyte character of some Brazilian native gums to fabricate electrically conductive, nanostructured films. The gums Sterculia urens, (caraia), Sterculia striata (chicha) or Anadenanthera macrocarpa Benth were assembled in conjunction with poly(o-methoxyaniline) (POMA) in the form of layered nanostructured films using the layer-by-layer (LbL) technique. All the LbL films displayed a well-defined electroactivity, as confirmed via cyclic voltammetry. In comparison to POMA LbL films fabricated with conventional polyelectrolytes (viz. poly(vinyl sulfonic acid)-PVS), the presence of the gums in the LbL films increased remarkably the electrochemical stability of the films.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Potentiometric sensors are very attractive tools for chemical analysis because of their simplicity, low power consumption and low cost. They are extensively used in clinical diagnostics and in environmental monitoring. Modern applications of both fields require improvements in the conventional construction and in the performance of the potentiometric sensors, as the trends are towards portable, on-site diagnostics and autonomous sensing in remote locations. The aim of this PhD work was to improve some of the sensor properties that currently hamper the implementation of the potentiometric sensors in modern applications. The first part of the work was concentrated on the development of a solid-state reference electrode (RE) compatible with already existing solid-contact ion-selective electrodes (ISE), both of which are needed for all-solid-state potentiometric sensing systems. A poly(vinyl chloride) membrane doped with a moderately lipophilic salt, tetrabutylammonium-tetrabutylborate (TBA-TBB), was found to show a satisfactory stability of potential in sample solutions with different concentrations. Its response time was nevertheless slow, as it required several minutes to reach the equilibrium. The TBA-TBB membrane RE worked well together with solid-state ISEs in several different situations and on different substrates enabling a miniature design. Solid contacts (SC) that mediate the ion-to-electron transduction are crucial components of well-functioning potentiometric sensors. This transduction process converting the ionic conduction of an ion-selective membrane to the electronic conduction in the circuit was studied with the help of electrochemical impedance spectroscopy (EIS). The solid contacts studied were (i) the conducting polymer (CP) poly(3,4-ethylienedioxythiophene) (PEDOT) and (ii) a carbon cloth having a high surface area. The PEDOT films were doped with a large immobile anion poly(styrene sulfonate) (PSS-) or with a small mobile anion Cl-. As could be expected, the studied PEDOT solid-contact mediated the ion-toelectron transduction more efficiently than the bare glassy carbon substrate, onto which they were electropolymerized, while the impedance of the PEDOT films depended on the mobility of the doping ion and on the ions in the electrolyte. The carbon cloth was found to be an even more effective ion-to-electron transducer than the PEDOT films and it also proved to work as a combined electrical conductor and solid contact when covered with an ion-selective membrane or with a TBA-TBB-based reference membrane. The last part of the work was focused on improving the reproducibility and the potential stability of the SC-ISEs, a problem that culminates to the stability of the standard potential E°. It was proven that the E° of a SC-ISE with a conducting polymer as a solid contact could be adjusted by reducing or oxidizing the CP solid contact by applying current pulses or a potential to it, as the redox state of the CP solid-contact influences the overall potential of the ISE. The slope and thus the analytical performance of the SC-ISEs were retained despite the adjustment of the E°. The shortcircuiting of the SC-ISE with a conventional large-capacitance RE was found to be a feasible instrument-free method to control the E°. With this method, the driving force for the oxidation/reduction of the CP was the potential difference between the RE and the SC-ISE, and the position of the adjusted potential could be controlled by choosing a suitable concentration for the short-circuiting electrolyte. The piece-to-piece reproducibility of the adjusted potential was promising, and the day-today reproducibility for a specific sensor was excellent. The instrumentfree approach to control the E° is very attractive considering practical applications.