849 resultados para Platform of contact


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objectives: To measure tear film surface quality (TFSQ) using dynamic high-speed videokeratoscopy during short-term (8 hours) use of rigid and soft contact lenses. Methods: A group of fourteen subjects wore 3 different types of contact lenses on 3 different non-consecutive days (order randomized) in one eye only. Subjects were screened to exclude those with dry eye. The lenses included a PMMA hard, an RGP (Boston XO) and a soft silicone hydrogel lens. Three 30 second long high speed videokeratoscopy recordings were taken with contact lenses in-situ, in the morning and again after 8 hours of contact lens wear, both in normal and suppressed blinking conditions. Recordings were also made on a baseline day with no contact lens wear. Results: The presence of a contact lens in the eye had a significant effect on the mean TFSQ in both natural and suppressed blinking conditions (p=0.001 and p=0.01 respectively, repeated measures ANOVA). TFSQ was worse with all the lenses compared to no lens in the eye (in the afternoon during both normal and suppressed blinking conditions (all p<0.05). In natural blinking conditions, the mean TFSQ for the PMMA and RGP lenses was significantly worse than the baseline day (no lens) for both morning and afternoon measures (p<0.05). Conclusions: This study shows that both rigid and soft contact lenses adversely affect the TFSQ in both natural and suppressed blinking conditions. No significant differences were found between the lens types and materials. Keywords: Tear film surface quality, rigid contact lens, soft contact lens, dynamic high-speed videokeratoscopy

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A breaker restrike is an abnormal arcing phenomenon, leading to a possible breaker failure. Eventually, this failure leads to interruption of the transmission and distribution of the electricity supply system until the breaker is replaced. Before 2008, there was little evidence in the literature of monitoring techniques based on restrike measurement and interpretation produced during switching of capacitor banks and shunt reactor banks in power systems. In 2008 a non-intrusive radiometric restrike measurement method and a restrike hardware detection algorithm were developed by M.S. Ramli and B. Kasztenny. However, the limitations of the radiometric measurement method are a band limited frequency response as well as limitations in amplitude determination. Current restrike detection methods and algorithms require the use of wide bandwidth current transformers and high voltage dividers. A restrike switch model using Alternative Transient Program (ATP) and Wavelet Transforms which support diagnostics are proposed. Restrike phenomena become a new diagnostic process using measurements, ATP and Wavelet Transforms for online interrupter monitoring. This research project investigates the restrike switch model Parameter „A. dielectric voltage gradient related to a normal and slowed case of the contact opening velocity and the escalation voltages, which can be used as a diagnostic tool for a vacuum circuit-breaker (CB) at service voltages between 11 kV and 63 kV. During current interruption of an inductive load at current quenching or chopping, a transient voltage is developed across the contact gap. The dielectric strength of the gap should rise to a point to withstand this transient voltage. If it does not, the gap will flash over, resulting in a restrike. A straight line is fitted through the voltage points at flashover of the contact gap. This is the point at which the gap voltage has reached a value that exceeds the dielectric strength of the gap. This research shows that a change in opening contact velocity of the vacuum CB produces a corresponding change in the slope of the gap escalation voltage envelope. To investigate the diagnostic process, an ATP restrike switch model was modified with contact opening velocity computation for restrike waveform signature analyses along with experimental investigations. This also enhanced a mathematical CB model with the empirical dielectric model for SF6 (sulphur hexa-fluoride) CBs at service voltages above 63 kV and a generalised dielectric curve model for 12 kV CBs. A CB restrike can be predicted if there is a similar type of restrike waveform signatures for measured and simulated waveforms. The restrike switch model applications are used for: computer simulations as virtual experiments, including predicting breaker restrikes; estimating the interrupter remaining life of SF6 puffer CBs; checking system stresses; assessing point-on-wave (POW) operations; and for a restrike detection algorithm development using Wavelet Transforms. A simulated high frequency nozzle current magnitude was applied to an Equation (derived from the literature) which can calculate the life extension of the interrupter of a SF6 high voltage CB. The restrike waveform signatures for a medium and high voltage CB identify its possible failure mechanism such as delayed opening, degraded dielectric strength and improper contact travel. The simulated and measured restrike waveform signatures are analysed using Matlab software for automatic detection. Experimental investigation of a 12 kV vacuum CB diagnostic was carried out for the parameter determination and a passive antenna calibration was also successfully developed with applications for field implementation. The degradation features were also evaluated with a predictive interpretation technique from the experiments, and the subsequent simulation indicates that the drop in voltage related to the slow opening velocity mechanism measurement to give a degree of contact degradation. A predictive interpretation technique is a computer modeling for assessing switching device performance, which allows one to vary a single parameter at a time; this is often difficult to do experimentally because of the variable contact opening velocity. The significance of this thesis outcome is that it is a non-intrusive method developed using measurements, ATP and Wavelet Transforms to predict and interpret a breaker restrike risk. The measurements on high voltage circuit-breakers can identify degradation that can interrupt the distribution and transmission of an electricity supply system. It is hoped that the techniques for the monitoring of restrike phenomena developed by this research will form part of a diagnostic process that will be valuable for detecting breaker stresses relating to the interrupter lifetime. Suggestions for future research, including a field implementation proposal to validate the restrike switch model for ATP system studies and the hot dielectric strength curve model for SF6 CBs, are given in Appendix A.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: The aim of this cross-over study was to investigate the changes in corneal thickness, anterior and posterior corneal topography, corneal refractive power and ocular wavefront aberrations, following the short term use of rigid contact lenses. Method: Fourteen participants wore 4 different types of contact lenses (RGP lenses of 9.5 mm and 10.5 mm diameter, and for comparison a PMMA lens of 9.5 mm diameter and a soft silicone hydrogel lens) on 4 different days for a period of 8 h on each day. Measures were collected before and after contact lens wear and additionally on a baseline day. Results: Anterior corneal curvature generally showed a flattening with both of the RGP lenses and a steepening with the PMMA lens. A significant negative correlation was found between the change in corneal swelling and central and peripheral posterior corneal curvature (all p ≤ 0.001). RGP contact lenses caused a significant decrease in corneal refractive power (hyperopic shift) of approximately 0.5 D. The PMMA contact lenses caused the greatest corneal swelling in both the central (27.92 ± 15.49 μm, p < 0.001) and peripheral (17.78 ± 12.11 μm, p = 0.001) corneal regions, a significant flattening of the posterior cornea and an increase in ocular aberrations (all p ≤ 0.05). Conclusion: The corneal swelling associated with RGP lenses was relatively minor, but there was slight central corneal flattening and a clinically significant hyperopic change in corneal refractive power after the first day of lens wear. The PMMA contact lenses resulted in significant corneal swelling and reduced optical performance of the cornea.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose To determine the prevalence of papillary changes of the upper palpebral conjunctiva and folliculosis of the lower palpebral conjunctiva in Chinese children with no history of contact lens wear. Method Ninety-nine subjects (aged 6–15 years old) who were interested in a myopia control study were screened for papillary changes and folliculosis of the palpebral conjunctiva. Photodocumentation was performed under white and blue light (after the application of fluorescein) with a yellow filter and the photographs were graded by a group of practitioners according to a pre-set grading scale. Analysis was performed with the subjects divided into groups according to gender and age. Results More than 48% of the subjects had clinically significant (≥Grade 3) papillary changes in the upper palpebral conjunctiva. The prevalence of significant folliculosis in the lower lid was about 33%. The prevalence of significant papillary changes and folliculosis were similar between genders. No differences were observed between younger (age ≤ 10 years old) and older (age > 10 years old) in papillary changes but younger subjects showed a higher prevalence of folliculosis. Conclusions The prevalences of clinically significant papillary changes and folliculosis of unknown aetiology are high in Chinese children.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: Studies on the relationship between performance and design of the throwing frame have been limited and therefore require further investigation. Objectives: The specific objectives were to provide benchmark information about performance and whole body positioning of male athletes in F30s classes. Study Design: Descriptive analysis. Methods: A total of 48 attempts performed by 12 stationary discus throwers in F33 and F34 classes during seated discus throwing event of 2002 International Paralympic Committee Athletics World Championships were analysed in this study. The whole body positioning included overall throwing posture (i.e. number of points of contact between the thrower and the frame, body position, throwing orientation and throwing side) and lower limb placements (i.e. seating arrangements, points of contact on the both feet, type of attachment of both legs and feet). Results: Three (25%), five (42%), one (8%) and three (25%) athletes used from three to six points of contact, respectively. Seven (58%) and five (42%) athletes threw from a standing or a seated position, respectively. A straddle, a stool or a chair was used by six (50%), four (33%) or two (17%) throwers, respectively. Conclusions: This study provides key information for a better understanding of the interaction between throwing technique of elite seated throwers and their throwing frame.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: People often modify oral solid dosage forms when they experience difficulty swallowing them. Modifying dosage forms may cause adverse effects to the patient, and the person undertaking the modification. Pharmacists are often the first point of contact for people in the general community seeking advice regarding medications. Nurses are at the forefront of administering medications to patients and are likely to be most directly affected by a patient’s swallowing ability, while general practitioners (GPs) are expected to consider swallowing abilities when prescribing medications. Objective: To compare the perspectives and experiences of GPs, pharmacists, and nurses regarding medication dosage form modification and their knowledge of medication modification. Method: Questionnaires tailored to each profession were posted to 630 GPs, and links to an online version were distributed to 2,090 pharmacists and 505 nurses. Results: When compared to pharmacists and GPs, nurses perceived that a greater proportion of the general community modified solid dosage forms. Pharmacists and GPs were most likely to consider allergies and medical history when deciding whether to prescribe or dispense a medicine, while nurses’ priorities were allergies and swallowing problems when administering medications. While nurses were more likely to ask their patients about their ability to swallow medications, most health professionals reported that patients “rarely” or “never” volunteered information about swallowing difficulties. The majority of health professionals would advise a patient to crush or split noncoated non-sustained-release tablets, and would consult colleagues or reference sources for sustained-release or coated tablets. Health professionals appeared to rely heavily upon the suffix attached to medication names (which suggest modified release properties) to identify potential problems associated with modifying medications. Conclusion: The different professional roles and responsibilities of GPs, pharmacists, and nurses are associated with different perspectives of, and experiences with, people modifying medications in the general community and knowledge about consequences of medication modification.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: To examine whether Chinese studies of child sexual abuse (CSA) in the general population show lower prevalence rates than other international studies, and whether certain features of these studies may help to account for variation in estimates. Methods: A meta-analysis and meta-regression were conducted on 27 studies found in the English and Chinese language peer reviewed journals that involved general populations of students or residents, estimated CSA prior to age 18, and specified rates for males or females individually. Results: Estimates for Chinese females were lower than the international composites. For total CSA for females, the Chinese pooled estimate was 15.3% (95% CI = 12.6–18.0) based on the meta-analysis of 24 studies, lower than the international estimate (Stoltenborgh, van IJzendoorn, Euser, & Bakermans-Kranenburg, 2011) but not significantly. For contact CSA for females, the pooled estimate was 9.5% (95% CI = 7.5–11.5), based on 16 studies, significantly lower than the international prevalence. For penetrative CSA for females, the pooled estimate was 1% (95% CI = 0.7–1.3), based on 15 studies, significantly lower than the international estimate of 15.1%. Chinese men reported significantly less penetrative CSA but significantly more total CSA than international estimates; while contact CSA reported by Chinese and international males appeared to be roughly equivalent. Chinese CSA prevalence estimates were lower in studies from urban areas and non-mainland areas (Hong Kong and Taiwan), and in surveys with larger and probability samples, multiple sites, face-to-face interview method and when using less widely used instruments. Conclusions: The findings to date justify further research into possible cultural and sociological reasons for lower risk of contact and penetrative sexual abuse of girls and less penetrative abuse of boys in China. Future research should examine sociological explanations, including patterns of supervision, sexual socialization and attitudes related to male sexual prowess. Practice implications: The findings suggest that future general population studies in China should use well validated instruments, avoid face-to-face interview formats and be careful to maintain methodological standards when sampling large populations over multiple sites.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

China's National Health and Family Planning Commission announced 3 deaths caused by avian-origin influenza A(H7N9) virus in March, which was the first time that the H7N9 strain has been found in humans [1]. This is of major public health significance and raises urgent questions and global concerns [2, 3]. To explore epidemic characteristics of human infections with H7N9 virus, data on individual cases from 19 February 2013 (onset date of first case) to 14 April 2013 were collected from the China Information System for Disease Control and Prevention, which included information about sex; age; occupation; residential address; and day of symptom onset, diagnosis, and outcome for each case. The definition of an unconfirmed probable H7N9 case is a patient with epidemiologic evidence of contact

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Moderator Opening The early focus of contact lens wear and ocular health was on oxygen delivery. However, as we learn more about how the eye works, and investigate how the contact lens interacts with the cornea, the role of the tear film has risen in prominence. A healthy tear film is critical for normal ocular homeostasis, and abnormalities of the tear film are the primary cause of dry eye. In order to improve patient eye health and comfort during lens wear, we need to further elucidate the relationship among contact lenses, contact lens solutions, the tear film, and the corneal epithelium, and find ways to maintain homeostasis of the ocular surface. In this section, we review the latest data and opinions on this complex relationship between contact lenses and lens care solutions

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Eye care practitioners (ECPs) would tend to agree that wearing contact lenses increases the risk for infection, but millions of patients are still fitted with lenses every year because ECPs feel that the risk is manageable and that their patients' eye health can be protected. The Fusarium and Acanthamoeba keratitis outbreaks of years past were a wake-up call to manufacturers, ECPs, and regulatory agencies that risk cannot be managed without diligence, and that the complex relationship between contact lens materials, contact lens solutions, and compliance needs to be better understood in order to optimize the efficacy of contact lens care and improve care guidelines.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In vivo confocal microscopy (IVCM) is an emerging technology that provides minimally invasive, high resolution, steady-state assessment of the ocular surface at the cellular level. Several challenges still remain but, at present, IVCM may be considered a promising technique for clinical diagnosis and management. This mini-review summarizes some key findings in IVCM of the ocular surface, focusing on recent and promising attempts to move “from bench to bedside”. IVCM allows prompt diagnosis, disease course follow-up, and management of potentially blinding atypical forms of infectious processes, such as acanthamoeba and fungal keratitis. This technology has improved our knowledge of corneal alterations and some of the processes that affect the visual outcome after lamellar keratoplasty and excimer keratorefractive surgery. In dry eye disease, IVCM has provided new information on the whole-ocular surface morphofunctional unit. It has also improved understanding of pathophysiologic mechanisms and helped in the assessment of prognosis and treatment. IVCM is particularly useful in the study of corneal nerves, enabling description of the morphology, density, and disease- or surgically induced alterations of nerves, particularly the subbasal nerve plexus. In glaucoma, IVCM constitutes an important aid to evaluate filtering blebs, to better understand the conjunctival wound healing process, and to assess corneal changes induced by topical antiglaucoma medications and their preservatives. IVCM has significantly enhanced our understanding of the ocular response to contact lens wear. It has provided new perspectives at a cellular level on a wide range of contact lens complications, revealing findings that were not previously possible to image in the living human eye. The final section of this mini-review provides a focus on advances in confocal microscopy imaging. These include 2D wide-field mapping, 3D reconstruction of the cornea and automated image analysis.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Contact lenses are a successful and popular means to correct refractive error and are worn by just under 700,000 Australians1 and approximately 125 million people worldwide. The most serious complication of contact lens wear is microbial keratitis, a potentially sight-threatening corneal infection most often caused by bacteria. Gram-negative bacteria, in particular pseudomonas species, account for the majority of severe bacterial infections. Pathogens such as fungi or amoebae, which feature less often, are associated with significant morbidity. These unusual pathogens have come into the spotlight in recent times with an apparent association with specific lens cleaning solutions...

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper explores how the amalgamated wisdom of East and West can instigate a wisdombased renaissance of humanistic epistemology (Rooney & McKenna, 2005) to provide a platform of harmony in managing knowledge-worker productivity, one of the biggest management challenges of the 21st century (Drucker, 1999). The paper invites further discussions from the social and business research communities on the significance of "interpretation realism" technique in comprehending philosophies of Lao Tzu Confucius and Sun Tzu (Lao/Confucius/Sun] written in "Classical Chinese." This paper concludes with a call to build prudent, responsible practices in management which affects the daily lives of many (Rooney & McKenna, 2005) in today's knowledgebased economy. Interpretation Realism will be applied to an analysis of three Chinese classics of Lao/Confucius/Sun which have been embodied in the Chinese culture for over 2,500 years. Comprehending Lao/Confucius/Sun's philosophies is the first step towards understanding Classical Chinese culture. However, interpreting Chinese subtlety in language and the yin and yang circular synthesis in their mode of thinking is very different to understanding Western thought with its open communication and its linear, analytical pattern of Aristotelian/Platonic wisdom (Zuo, 2012). Furthermore, Eastern ways of communication are relatively indirect and mediatory in culture. Western ways of communication are relatively direct and litigious in culture (Goh, 2002). Furthermore, Lao/Confucius/Sun's philosophies are difficult to comprehend as there are four written Chinese formats and over 250 dialects: Pre-classical Chinese Classical Chinese Literary Chinese and modern Vernacular Chinese Because Classical Chinese is poetic, comprehension requires a mixed approach of interpretation realism combining logical reasoning behind "word splitting word occurrences", "empathetic metaphor" and "poetic appreciation of word.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

For the past nine years, we have described the current state of contact lens fitting worldwide in Contact Lens Spectrum. This year, we report on 24,642 lens fits in 27 markets. As in all previous years, coordinators in each market distributed up to 1,000 paper or electronic survey forms to contact lens practitioners who, in turn, collected information about their next 10 fits. Data were processed and checked in the survey administrative offices in Manchester, United Kingdom and in Waterloo, Canada.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This is the 11th annual report of contact lens prescribing trends that we have prepared for Contact Lens Spectrum. Each year, we capture current modes of contact lens practice by asking practitioners in each market (optometrists, opticians or ophthalmologists, as appropriate) to provide information about the first 10 lens fits undertaken after receiving our paper or electronic survey form. In 2011, we captured information about 22,362 fits in 29 countries.