849 resultados para Performance evaluation of business incubators


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The mixing performance of three passive milli-scale reactors with different geometries was investigated at different Reynolds numbers. The effects of design and operating characteristics such as mixing channel shape and volume flow rate were investigated. The main objective of this work was to demonstrate a process design method that uses on Computational Fluid Dynamics (CFD) for modeling and Additive Manufacturing (AM) technology for manufacture. The reactors were designed and simulated using SolidWorks and Fluent 15.0 software, respectively. Manufacturing of the devices was performed with an EOS M-series AM system. Step response experiments with distilled Millipore water and sodium hydroxide solution provided time-dependent concentration profiles. Villermaux-Dushman reaction experiments were also conducted for additional verification of CFD results and for mixing efficiency evaluation of the different geometries. Time-dependent concentration data and reaction evaluation showed that the performance of the AM-manufactured reactors matched the CFD results reasonably well. The proposed design method allows the implementation of new and innovative solutions, especially in the process design phase, for industrial scale reactor technologies. In addition, rapid implementation is another advantage due to the virtual flow design and due to the fast manufacturing which uses the same geometric file formats.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Malicious users try to compromise systems using new techniques. One of the recent techniques used by the attacker is to perform complex distributed attacks such as denial of service and to obtain sensitive data such as password information. These compromised machines are said to be infected with malicious software termed a “bot”. In this paper, we investigate the correlation of behavioural attributes such as keylogging and packet flooding behaviour to detect the existence of a single bot on a compromised machine by applying (1) Spearman’s rank correlation (SRC) algorithm and (2) the Dendritic Cell Algorithm (DCA). We also compare the output results generated from these two methods to the detection of a single bot. The results show that the DCA has a better performance in detecting malicious activities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The functional and structural performance of a 5 cm synthetic small diameter vascular graft (SDVG) produced by the copolymerization of polyvinyl alcohol hydrogel with low molecular weight dextran (PVA/Dx graft) associated to mesenchymal stem cells (MSCs)-based therapies and anticoagulant treatment with heparin, clopidogrel and warfarin was tested using the ovine model during the healing period of 24 weeks. The results were compared to the ones obtained with standard expanded polyetetrafluoroethylene grafts (ePTFE graft). Blood flow, vessel and graft diameter measurements, graft appearance and patency rate (PR), thrombus, stenosis and collateral vessel formation were evaluated by B-mode ultrasound, audio and color flow Doppler. Graft and regenerated vessels morphologic evaluation was performed by scanning electronic microscopy (SEM), histopathological and immunohistochemical analysis. All PVA/Dx grafts could maintain a similar or higher PR and systolic / diastolic laminar blood flow velocities were similar to ePTFE grafts. CD14 (macrophages) and α-actin (smooth muscle) staining presented similar results in PVA/Dx/MSCs and ePTFE graft groups. Fibrosis layer was lower and endothelial cells were only detected at graft-artery transitions where it was added the MSCs. In conclusion, PVA/Dx graft can be an excellent scaffold candidate for vascular reconstruction, including clinic mechanically challenging applications, such as SDVGs, especially when associated to MSCs-based therapies to promote higher endothelialization and lower fibrosis of the vascular prosthesis, but also higher PR values.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O texto traz uma reflexão sobre o papel das incubadoras de empresas no apoio a práticas ambientais por micro e pequenas empresas. Reconhecendo as debilidades estruturais das empresas de pequeno porte e as dificuldades para a realização de investimentos ambientais, defende o uso de incubadoras como instrumento de política pública para estimular investimentos ambientais. Identifica um número restrito de incubadoras de tecnologias ambientais, em plano internacional. Relata os resultados de uma pesquisa que avaliou a aplicabilidade de um indicador para apurar o desempenho ambiental de incubadoras. Destacaram-se dois resultados: a) a baixa importância atribuída, pelas incubadoras (e pelas empresas abrigadas) ao desempenho ambiental; e b) a ausência de estímulos, pelas incubadoras, aos investimentos ambientais. Desse último resultado deriva importante conclusão: a de que, uma vez apurados os padrões insatisfatórios de desempenho ambiental, de incubadoras e empresas assistidas, ficariam criadas as condições para a formulação e a implementação de medidas indutoras de novas posturas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This project is focused on exchanging knowledge between ABS, UKBI and managers of business incubators in the UK. The project relates to exploitation of extant knowledge-base on assessing and improving business incubation management practice and performance and builds on two earlier studies. It addresses a pressing need for assessing and benchmarking business incubation input, process and outcome performance and highlighting best practice. The overarching aim of this project was to obtain proof-of-concept for a business incubation performance assessment and benchmarking online tool, fine-tune it and put it in use by nurturing a community of business incubation management practice, aligned by the resultant tool. The purpose was to offer an appropriate set of measures, in areas identified by relevant research on business incubation performance management and impact as critical, against which: 1.The input and process performance of business incubation management practice can be assessed and benchmarked within the auspices of a community of incubator managers concerned with best practice 2.The outcome performance and impact of business incubators can be assessed longitudinally. As such, the developed online assessment framework is geared towards the needs of researchers, policy makers and practitioners concerned with business incubation performance, added value and impact.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main aim of this research is to demonstrate strategic supplier performance evaluation of a UK-based manufacturing organisation using an integrated analytical framework. Developing long term relationship with strategic suppliers is common in today's industry. However, monitoring suppliers' performance all through the contractual period is important in order to ensure overall supply chain performance. Therefore, client organisations need to measure suppliers' performance dynamically and inform them on improvement measures. Although there are many studies introducing innovative supplier performance evaluation frameworks and empirical researches on identifying criteria for supplier evaluation, little has been reported on detailed application of strategic supplier performance evaluation and its implication on overall performance of organisation. Additionally, majority of the prior studies emphasise on lagging factors (quality, delivery schedule and value/cost) for supplier selection and evaluation. This research proposes both leading (organisational practices, risk management, environmental and social practices) and lagging factors for supplier evaluation and demonstrates a systematic method for identifying those factors with the involvement of relevant stakeholders and process mapping. The contribution of this article is a real-life case-based action research utilising an integrated analytical model that combines quality function deployment and the analytic hierarchy process method for suppliers' performance evaluation. The effectiveness of the method has been demonstrated through number of validations (e.g. focus group, business results, and statistical analysis). Additionally, the study reveals that enhanced supplier performance results positive impact on operational and business performance of client organisation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This report fully summarises a project designed to enhance commercial real estate performance within both operational and investment contexts through the development of a model aimed at supporting improved decision-making. The model is based on a risk adjusted discounted cash flow, providing a valuable toolkit for building managers, owners, and potential investors for evaluating individual building performance in terms of financial, social and environmental criteria over the complete life-cycle of the asset. The ‘triple bottom line’ approach to the evaluation of commercial property has much significance for the administrators of public property portfolios in particular. It also has applications more generally for the wider real estate industry given that the advent of ‘green’ construction requires new methods for evaluating both new and existing building stocks. The research is unique in that it focuses on the accuracy of the input variables required for the model. These key variables were largely determined by market-based research and an extensive literature review, and have been fine-tuned with extensive testing. In essence, the project has considered probability-based risk analysis techniques that required market-based assessment. The projections listed in the partner engineers’ building audit reports of the four case study buildings were fed into the property evaluation model developed by the research team. The results are strongly consistent with previously existing, less robust evaluation techniques. And importantly, this model pioneers an approach for taking full account of the triple bottom line, establishing a benchmark for related research to follow. The project’s industry partners expressed a high degree of satisfaction with the project outcomes at a recent demonstration seminar. The project in its existing form has not been geared towards commercial applications but it is anticipated that QDPW and other industry partners will benefit greatly by using this tool for the performance evaluation of property assets. The project met the objectives of the original proposal as well as all the specified milestones. The project has been completed within budget and on time. This research project has achieved the objective by establishing research foci on the model structure, the key input variable identification, the drivers of the relevant property markets, the determinants of the key variables (Research Engine no.1), the examination of risk measurement, the incorporation of risk simulation exercises (Research Engine no.2), the importance of both environmental and social factors and, finally the impact of the triple bottom line measures on the asset (Research Engine no. 3).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multiple reaction monitoring (MRM) mass spectrometry coupled with stable isotope dilution (SID) and liquid chromatography (LC) is increasingly used in biological and clinical studies for precise and reproducible quantification of peptides and proteins in complex sample matrices. Robust LC-SID-MRM-MS-based assays that can be replicated across laboratories and ultimately in clinical laboratory settings require standardized protocols to demonstrate that the analysis platforms are performing adequately. We developed a system suitability protocol (SSP), which employs a predigested mixture of six proteins, to facilitate performance evaluation of LC-SID-MRM-MS instrument platforms, configured with nanoflow-LC systems interfaced to triple quadrupole mass spectrometers. The SSP was designed for use with low multiplex analyses as well as high multiplex approaches when software-driven scheduling of data acquisition is required. Performance was assessed by monitoring of a range of chromatographic and mass spectrometric metrics including peak width, chromatographic resolution, peak capacity, and the variability in peak area and analyte retention time (RT) stability. The SSP, which was evaluated in 11 laboratories on a total of 15 different instruments, enabled early diagnoses of LC and MS anomalies that indicated suboptimal LC-MRM-MS performance. The observed range in variation of each of the metrics scrutinized serves to define the criteria for optimized LC-SID-MRM-MS platforms for routine use, with pass/fail criteria for system suitability performance measures defined as peak area coefficient of variation <0.15, peak width coefficient of variation <0.15, standard deviation of RT <0.15 min (9 s), and the RT drift <0.5min (30 s). The deleterious effect of a marginally performing LC-SID-MRM-MS system on the limit of quantification (LOQ) in targeted quantitative assays illustrates the use and need for a SSP to establish robust and reliable system performance. Use of a SSP helps to ensure that analyte quantification measurements can be replicated with good precision within and across multiple laboratories and should facilitate more widespread use of MRM-MS technology by the basic biomedical and clinical laboratory research communities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This research aimed to develop a framework for performance evaluation of public hospitals in Vietnam that is culturally, socially, and politically appropriate. The research included both qualitative and quantitative methods and identified and validated novel instruments to measure patient satisfaction and job satisfaction of hospital staff and to determine a set of hospital indicators that reflect the quality of hospital performance. New models for understanding the determinants of patient and staff satisfaction were developed along with a new performance indicator framework for hospital performance. These instruments will now be applied to the evaluation of hospital services in Khanh Hoa Province, permitting longer term evaluation of their effectiveness in changing system wide performance and satisfaction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The government of the UK has set an ambitious target that all newly built homes be carbon neutral by 2016 and to achieving an overall 80% carbon emission by 2050. Carbon Trust in 2009 published a research revealing that non-domestic buildings accounted for 18% of the emissions in the UK. They argued that to achieve the targets of low carbon emission there is need for better building stock that are better used. The evaluation of the performance of buildings is therefore critical if the understanding of how they are used is to be known. This paper is a brief building performance evaluation of the newly build library at Queens University Belfast carried out during the summer of 2010. It employed the Post-Occupancy Evaluation (POE) methodology to assess its performance. The results reveal that despite the intelligent technologies in the building there was a mismatch between the measured data and the perception of users of its performance. The study suggests the need for further study for reasons of dichotomy of the data. Keywords: building performance evaluation, carbon reduction strategies, passive environmental design techniques, active renewable energy technologies, Northern Ireland

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For Variable Stiffness (VS) composites with steered curvilinear tow paths, the fiber orientation angle varies continuously throughout the laminate, and is not required to be straight, parallel and uniform within each ply as in conventional composite laminates. Hence, the thermal properties (conduction), as well as the structural stiffness and strength, vary as functions of location in the laminate, and the associated composite structure is often called a “variable stiffness” composite structure. The steered fibers lead not only to the alteration of mechanical load paths, but also to the alteration of thermal paths that may
result in favorable temperature distributions within the laminate and improve the laminate performance. Evaluation of VS laminate performance under thermal loading is the focus of this chapter. Thermal performance evaluations require experimental and numerical analysis of VS laminates under different processing and loading conditions. One of the advantages of using composite materials in many applications is the tailoring capability of the laminate,
not only during the design phase but also for manufacturing. Heat transfer through variable conduction and chemical reaction (degree of cure) occurring during manufacturing (curing) plays an important role in the final thermal and mechanical performance, and shape of composite structures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Photovoltaic Thermal/Hybrid collectors are an emerging technology that combines PV and solar thermal collectors by producing heat and electricity simultaneously. In this paper, the electrical performance evaluation of a low concentrating PVT collector was done through two testing parts: power comparison and performance ratio testing. For the performance ratio testing, it is required to identify and measure the factors affecting the performance ratio on a low concentrating PVT collector. Factors such as PV cell configuration, collector acceptance angle, flow rate, tracking the sun, temperature dependence and diffuse to irradiance ratio. Solarus low concentrating PVT collector V12 was tested at Dalarna University in Sweden using the electrical equipment at the solar laboratory. The PV testing has showed differences between the two receivers. Back2 was producing 1.8 energy output more than Back1 throughout the day. Front1 and Front2 were almost the same output performance. Performance tests showed that the cell configuration for Receiver2 with cells grouping (6- 32-32-6) has proved to have a better performance ratio when to it comes to minimizing the shading effect leading to more output power throughout the day because of lowering the mismatch losses. Different factors were measured and presented in this thesis in chapter 5. With the current design, it has been obtained a peak power at STC of 107W per receiver. The solar cells have an electrical efficiency of approximately 19% while the maximum measured electrical efficiency for the collector was approximately 18 % per active cell area, in addition to a temperature coefficient of -0.53%/ ˚C. Finally a recommendation was done to help Solarus AB to know how much the electrical performance is affected during variable ambient condition and be able to use the results for analyzing and introducing new modification if needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This experiment aimed at evaluating the effects of the interactions between aflatoxin (500 or 250 ppb) and ochratoxin (500 or 250 ppb), and the possible benefits of adding yeast cell wall to prevent the effects of these mycotoxins in broiler chickens. Relative organ weight gain and live performance were evaluated at 21 and 42 days of age. Results indicated that at the levels of mycotoxins included in the experimental diets, ochratoxin reduced feed intake and body weight gain, and aflatoxin only affect feed intake of 21-day-old birds. No interaction was observed between aflatoxin and ochratoxin at the levels used in experimental study. Yeast cell wall did not significantly reduced the deleterious effects of ochratoxins. No significant differences were observed in relative organ weight gain. Yeast cell wall improved feed conversion ratio when birds were fed either contaminated or non-contaminated feeds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper assesses the importance of fund flows in the performance evaluation of Australian international equity funds. Two concepts of fund flows are considered in the context of a conditional asset pricing model. The first measure is net fund flow relative to fund size and the second is net fund flow relative to sector flows. We find that incorporating a fund flow measure relative to the sector flow results in a reduction of measured perverse market timing. The results indicate that, at the individual fund level, cash flows are relevant in assessing management outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis investigates the coefficient of performance (COP) of a hybrid liquid desiccant solar cooling system. This hybrid cooling system includes three sections: 1) conventional air-conditioning section; 2) liquid desiccant dehumidification section and 3) air mixture section. The air handling unit (AHU) with mixture variable air volume design is included in the hybrid cooling system to control humidity. In the combined system, the air is first dehumidified in the dehumidifier and then mixed with ambient air by AHU before entering the evaporator. Experiments using lithium chloride as the liquid desiccant have been carried out for the performance evaluation of the dehumidifier and regenerator. Based on the air mixture (AHU) design, the electrical coefficient of performance (ECOP), thermal coefficient of performance (TCOP) and whole system coefficient of performance (COPsys) models used in the hybrid liquid desiccant solar cooing system were developed to evaluate this system performance. These mathematical models can be used to describe the coefficient of performance trend under different ambient conditions, while also providing a convenient comparison with conventional air conditioning systems. These models provide good explanations about the relationship between the performance predictions of models and ambient air parameters. The simulation results have revealed the coefficient of performance in hybrid liquid desiccant solar cooling systems substantially depends on ambient air and dehumidifier parameters. Also, the liquid desiccant experiments prove that the latent component of the total cooling load requirements can be easily fulfilled by using the liquid desiccant dehumidifier. While cooling requirements can be met, the liquid desiccant system is however still subject to the hysteresis problems.