965 resultados para PV inverter


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A common problem when planning large free field PV-plants is optimizing the ground occupation ratio while maintaining low shading losses. Due to the complexity of this task, several PV-plants have been built using various configurations. In order to compare the shading losses of different PV technologies and array designs, empirical performance data of five free field PV-plants operating in Germany was analyzed. The data collected comprised 140 winter days from October 2011 until March 2012. The relative shading losses were estimated by comparing the energy output of selected arrays in the front rows (shading-free) against that of shaded arrays in the back rows of the same plant. The results showed that landscape mounting with mc-Si PV-modules yielded significantly better results than portrait one. With CIGS modules, making cross-table strings using the lower modules was not beneficial as expected and had more losses than a one-string-per-table layout. Parallel substrings with CdTe showed relatively low losses. Among the two CdTe products analyzed, none showed a significantly better performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis the solar part of a large grid-connected photovoltaic system design has been done. The main purpose was to size and optimize the system and to present figures helping to evaluate the prospective project rationality, which can potentially be constructed on a contaminated area in Falun. The methodology consisted in PV market study and component selection, site analysis and defining suitable area for solar installation; and system configuration optimization based on PVsyst simulations and Levelized Cost of Energy calculations. The procedure was mainly divided on two parts, preliminary and detailed sizing. In the first part the objective was complex, which included the investigation of the most profitable component combination and system optimization due to tilt and row distance. It was done by simulating systems with different components and orientations, which were sized for the same 100kW inverter in order to make a fair comparison. For each simulated result a simplified LCOE calculation procedure was applied. The main results of this part show that with the price of 0.43 €/Wp thin-film modules were the most cost effective solution for the case with a great advantage over crystalline type in terms of financial attractiveness. From the results of the preliminary study it was possible to select the optimal system configuration, which was used in the detailed sizing as a starting point. In this part the PVsyst simulations were run, which included full scale system design considering near shadings created by factory buildings. Additionally, more complex procedure of LCOE calculation has been used here considered insurances, maintenance, time value of money and possible cost reduction due to the system size. Two system options were proposed in final results; both cover the same area of 66000 m2. The first one represents an ordinary South faced design with 1.1 MW nominal power, which was optimized for the highest performance. According to PVsyst simulations, this system should produce 1108 MWh/year with the initial investment of 835,000 € and 0.056 €/kWh LCOE. The second option has an alternative East-West orientation, which allows to cover 80% of occupied ground and consequently have 6.6 MW PV nominal power. The system produces 5388 MWh/year costs about 4500,000 € and delivers electricity with the same price of 0.056 €/kWh. Even though the EW solution has 20% lower specific energy production, it benefits mainly from lower relative costs for inverters, mounting and annual maintenance expenses. After analyzing the performance results, among the two alternatives none of the systems showed a clear superiority so there was no optimal system proposed. Both, South and East-West solutions have own advantages and disadvantages in terms of energy production profile, configuration, installation and maintenance. Furthermore, the uncertainty due to cost figures assumptions restricted the results veracity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The demand for cooling and air-conditioning of building is increasingly ever growing. This increase is mostly due to population and economic growth in developing countries, and also desire for a higher quality of thermal comfort. Increase in the use of conventional cooling systems results in larger carbon footprint and more greenhouse gases considering their higher electricity consumption, and it occasionally creates peaks in electricity demand from power supply grid. Solar energy as a renewable energy source is an alternative to drive the cooling machines since the cooling load is generally high when solar radiation is high. This thesis examines the performance of PV/T solar collector manufactured by Solarus company in a solar cooling system for an office building in Dubai, New Delhi, Los Angeles and Cape Town. The study is carried out by analyzing climate data and the requirements for thermal comfort in office buildings. Cooling systems strongly depend on weather conditions and local climate. Cooling load of buildings depend on many parameters such as ambient temperature, indoor comfort temperature, solar gain to the building and internal gains including; number of occupant and electrical devices. The simulations were carried out by selecting a suitable thermally driven chiller and modeling it with PV/T solar collector in Polysun software. Fractional primary energy saving and solar fraction were introduced as key figures of the project to evaluate the performance of cooling system. Several parametric studies and simulations were determined according to PV/T aperture area and hot water storage tank volume. The fractional primary energy saving analysis revealed that thermally driven chillers, particularly adsorption chillers are not suitable to be utilizing in small size of solar cooling systems in hot and tropic climates such as Dubai and New Delhi. Adsorption chillers require more thermal energy to meet the cooling load in hot and dry climates. The adsorption chillers operate in their full capacity and in higher coefficient of performance when they run in a moderate climate since they can properly reject the exhaust heat. The simulation results also indicated that PV/T solar collector have higher efficiency in warmer climates, however it requires a larger size of PV/T collectors to supply the thermally driven chillers for providing cooling in hot climates. Therefore using an electrical chiller as backup gives much better results in terms of primary energy savings, since PV/T electrical production also can be used for backup electrical chiller in a net metering mechanism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report contains a suggestion for a simple monitoring and evaluation guideline for PV-diesel hybrid systems. It offers system users a way to better understand if their system is operated in a way that will make it last for a long time. It also gives suggestions on how to act if there are signs of unfavourable use or failure. The application of the guide requires little technical equipment, but daily manual measurements. For the most part, it can be managed by pen and paper, by people with no earlier experience of power systems.The guide is structured and expressed in a way that targets PV-diesel hybrid system users with no, or limited, earlier experience of power engineering. It is less detailed in terms of motivations for certain choices and limitations, but rich in details concerning calculations, evaluation procedures and maintenance routines. A more scientific description of the guide can be found in a related journal article.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste trabalho foi de buscar alternativas para aumentar a eficiência do controle do cancro cítrico (Xanthomonas citri pv. citri) nos pomares do Rio Grande do Sul, avaliando o efeito de concentrações de três bactericidas cúpricos e de duas freqüências de pulverização nas fases de intensa brotação.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A detecção, a transmissão e o efeito de Xanthomonas campestris pv. campestris (Xcc) na qualidade fisiológica de sementes de brócolis (Brassica oleracea var. italica) foram avaliados, a partir de sementes obtidas de plantas (Baron, Flórida, Hana Midori Sakata, Precoce Piracicaba de Verão, Ramoso Santana e Sabre) inoculadas com a bactéria, em condições de campo. Para a detecção do patógeno nas sementes foram utilizados os meios de cultura semi-seletivos: SX ágar, NSCAA e BSCAA; a taxa de transmissão da bactéria pelas sementes às plântulas foi avaliada usando semeadura em areia e meio de cultura contido em tubo de ensaio. Para a avaliação da qualidade fisiológica de sementes foram realizados o teste padrão de germinação e os testes de vigor: envelhecimento acelerado, índice de velocidade de emergência, crescimento de plântulas e massa seca. de acordo com os resultados, o meio de cultura semi-seletivo NSCAA foi mais eficaz para detectar Xcc em sementes de brócolis; não houve diferença significativa entre os genótipos na taxa de transmissão da bactéria pelas sementes e Xcc não afetou a germinação e o vigor das sementes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this research was to evaluate nitrogen, phosforus, potassium, calcium, magnesium, and sulfur contents on shoot dry matter of bean plants cultivars IAC Carioca Arua, IAC Carioca Pyata, IAC Carioca Akyta (resistant to the bacterial wilt), IAC Carioca, and Perola (susceptible to the bacterial wilt) inoculated or not with one isolate of Curtobacterium flaccumfaciens pv. flaccumfaciens. It was observed that all cultivars infected by C. flaccumfaciens pv. flaccumfaciens showed reduction of shoot dry matter and macronutrient contents. However, resistant cultivars had a lower reduction of nitrogen, phosforus, potassium, calcium, and magnesium contents than bacterial wilt suceptible cultivars.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atualmente há uma grande preocupação em relação a substituição das fontes não renováveis pelas fontes renováveis na geração de energia elétrica. Isto ocorre devido a limitação do modelo tradicional e da crescente demanda. Com o desenvolvimento dos conversores de potência e a eficácia dos esquemas de controle, as fontes renováveis têm sido interligadas na rede elétrica, em um modelo de geração distribuída. Neste sentido, este trabalho apresenta uma estratégia de controle não convencional, com a utilização de um controlador robusto, para a interconexão de sistemas fotovoltaicos com à rede elétrica trifásica. A compensação da qualidade de energia no ponto de acoplamento comum (PAC) é realizada pela estratégia proposta. As técnicas tradicionais utilizam detecção de harmônicos, já neste trabalho o controle das correntes é feita de uma forma indireta sem a necessidade desta detecção. Na estratégia indireta é de grande importância que o controle da tensão do barramento CC seja efetuado de uma forma que não haja grandes flutuações, e que a banda passante do controlador em regime permanente seja baixa para que as correntes da rede não tenham um alto THD. Por este motivo é utilizado um controlador em modo dual DSM-PI, que durante o transitório se comporta como um controlador em modo deslizante SM-PI, e em regime se comporta como um PI convencional. A corrente é alinhada ao ângulo de fase do vetor tensão da rede elétrica, obtido a partir do uso de um PLL. Esta aproximação permite regular o fluxo de potência ativa, juntamente com a compensação dos harmônicos e também promover a correção do fator de potência no ponto de acoplamento comum. Para o controle das correntes é usado um controlador dupla sequencia, que utiliza o princípio do modelo interno. Resultados de simulação são apresentados para demonstrar a eficácia do sistema de controle proposto

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the survival of a strain of Xanthomonas axonopodis pv. phaseoli var. fuscans (Xap), resistant to streptomycin sulphate, in common bean leaflets placed on the sod surface and buried at a depth of 10 and 15 cm. Four assays were carried out from November 1998 to December 2000 in Bandeirantes (Paran, Brazil). The leaflets were collected every 15 days, crushed and the dilution-plated on a semi-selective medium. Under mild temperatures and low rainfall, Xap survived for 65 to 180 days in the leaflets on the sod surface, and for 30 to 120 days in those incorporated in the soil, regardless of the depth. When higher rainfall and temperatures occurred, the survival was from 45 to 60 days in the leaflets on the sod surface and from 30 to 45 days in those buried 10 or 15 cm deep.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Avaliou-se a ocorrência da murcha-de-curtobacterium em lavouras de feijoeiro comum em algumas localidades do Estado de Santa Catarina, nas safras 2002/03 e 2003/04, e o comportamento dos genótipos BRS Valente, Carioca, CHC 97-29, CHP 97-26, CNPF 8104, Diamante Negro, Empasc 201 - Chapecó, IAPAR 44, IPR Graúna, IPR Juriti, IPR Uirapuru, LP 9728, Pérola, SCS 202-Guará, Sel. CP 9310635, TPS Bionobre, TPS Bonito, TPS Magnífico, TPS Nobre, TPS Soberano e Xamego perante Curtobacterium flaccumfaciens pv. flaccumfaciens (Cff), em condições de casa-de-vegetação. As cultivares IAC Carioca Akytã, IAC Carioca Aruã e IAC Carioca Pyatã foram empregadas como padrões de resistência a Cff. As avaliações dos sintomas ocorreram aos 5, 10, 15, 20 e 25 dias após a inoculação (DAI) e, posteriormente, foi estimada a área abaixo da curva de progresso da murcha-de-curtobacterium (AACPMC), em cada genótipo. A doença esteve presente nos municípios de Campos Novos, Faxinal dos Guedes, Guatambu, Ipuaçu, Ponte Serrada e Tigrinhos e que, aos 10 DAI, as cultivares SCS 202 - Guará e IPR Juriti mostraram baixa severidade. Porém, aos 25 DAI, somente as cultivares padrões foram resistentes e apresentaram menor AACPMC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Observações com microscopia eletrônica de transmissão em secções ultrafinas de células de caules de feijoeiros (Phaseolus vulgaris L.), inoculados com Curtobacterium flaccumfaciens pv. flaccumfaciens (Cff), mostraram alterações nos vasos de xilema em genótipos de feijoeiros altamente resistentes, como formação de estrutura semelhante a tilose e presença de fibrilas ao redor das células bacterianas. em genótipos suscetíveis, Cff colonizou além de vasos de xilema, células parenquimáticas e metaxilema.