931 resultados para Operaatio Iraqi Freedom
Conflicts of Mobility, and the Mobility of Conflict: Rightslessness, Presence, Subjectivity, Freedom
Resumo:
Since 1991, no cases of Equine Infectious Anemia (EIA) have been reported in Switzerland. Risk factors for introduction of the virus into Switzerland are still present or have even increased as frequent inapparent infections, large numbers of imported horses, (since 2003) absence of compulsory testing prior to importation, EIA cases in surrounding Europe, possible illegal importation of horses, frequent short-term stays, poor knowledge of the disease among horse owners and even veterinarians. The aim of this study was to provide evidence of freedom from EIA in imported and domestic horses in Switzerland. The serum samples from 434 horses imported since 2003 as well as from 232 domestic horses fifteen years of age or older (since older horses have naturally had a longer time of being exposed to the risk of infection) were analysed using a commercially available ELISA test. All samples were seronegative, indicating that the maximum possible prevalence that could have been missed with this sample was 0.5% (95% confidence).
Resumo:
Oxford University Press 2011, ISBN 978-0-19-958037-8
Resumo:
Purpose: The aim of this work is to evaluate the geometric accuracy of a prerelease version of a new six degrees of freedom (6DoF) couch. Additionally, a quality assurance method for 6DoF couches is proposed. Methods: The main principle of the performance tests was to request a known shift for the 6DoF couch and to compare this requested shift with the actually applied shift by independently measuring the applied shift using different methods (graph paper, laser, inclinometer, and imaging system). The performance of each of the six axes was tested separately as well as in combination with the other axes. Functional cases as well as realistic clinical cases were analyzed. The tests were performed without a couch load and with a couch load of up to 200 kg and shifts in the range between −4 and +4 cm for the translational axes and between −3° and +3° for the rotational axes were applied. The quality assurance method of the new 6DoF couch was performed using a simple cube phantom and the imaging system. Results: The deviations (mean ± one standard deviation) accumulated over all performance tests between the requested shifts and the measurements of the applied shifts were −0.01 ± 0.02, 0.01 ± 0.02, and 0.01 ± 0.02 cm for the longitudinal, lateral, and vertical axes, respectively. The corresponding values for the three rotational axes couch rotation, pitch, and roll were 0.03° ± 0.06°, −0.04° ± 0.12°, and −0.01° ± 0.08°, respectively. There was no difference found between the tests with and without a couch load of up to 200 kg. Conclusions: The new 6DoF couch is able to apply requested shifts with high accuracy. It has the potential to be used for treatment techniques with the highest demands in patient setup accuracy such as those needed in stereotactic treatments. Shifts can be applied efficiently and automatically. Daily quality assurance of the 6DoF couch can be performed in an easy and efficient way. Long-term stability has to be evaluated in further tests.
Resumo:
About 500,000 elderly people in Switzerland suffer a fall each year. Thus medical attention and help are essential for these people, who mostly live alone without a caregiver. Only 3% of people aged over 65 in Switzerland use an emergency system. Personal telehealth devices allow patients to receive enough information about the appropriate treatment, as well as followup with their doctors and reports of any emergency, in the absence of any caregiver. This increases their quality of life in a cost-effective fashion. "Limmex"-a new medical emergency watch-was launched in Switzerland in 2011 and has been a great commercial success. In this paper, we give a brief review of this watch technology, along with the results of a survey of 620 users conducted by the Department of Emergency Medicine in Bern.
Resumo:
BACKGROUND Advanced lower extremity peripheral artery disease (PAD), whether presenting as acute limb ischemia (ALI) or chronic critical limb ischemia (CLI), is associated with high rates of cardiovascular ischemic events, amputation, and death. Past research has focused on strategies of revascularization, but few data are available that prospectively evaluate the impact of key process of care factors (spanning pre-admission, acute hospitalization, and post-discharge) that might contribute to improving short and long-term health outcomes. METHODS/DESIGN The FRIENDS registry is designed to prospectively evaluate a range of patient and health system care delivery factors that might serve as future targets for efforts to improve limb and systemic outcomes for patients with ALI or CLI. This hypothesis-driven registry was designed to evaluate the contributions of: (i) pre-hospital limb ischemia symptom duration, (ii) use of leg revascularization strategies, and (iii) use of risk-reduction pharmacotherapies, as pre-specified factors that may affect amputation-free survival. Sequential patients would be included at an index "vascular specialist-defined" ALI or CLI episode, and patients excluded only for non-vascular etiologies of limb threat. Data including baseline demographics, functional status, co-morbidities, pre-hospital time segments, and use of medical therapies; hospital-based use of revascularization strategies, time segments, and pharmacotherapies; and rates of systemic ischemic events (e.g., myocardial infarction, stroke, hospitalization, and death) and limb ischemic events (e.g., hospitalization for revascularization or amputation) will be recorded during a minimum of one year follow-up. DISCUSSION The FRIENDS registry is designed to evaluate the potential impact of key factors that may contribute to adverse outcomes for patients with ALI or CLI. Definition of new "health system-based" therapeutic targets could then become the focus of future interventional clinical trials for individuals with advanced PAD.
Resumo:
We consider the Schrödinger equation for a relativistic point particle in an external one-dimensional δ-function potential. Using dimensional regularization, we investigate both bound and scattering states, and we obtain results that are consistent with the abstract mathematical theory of self-adjoint extensions of the pseudodifferential operator H=p2+m2−−−−−−−√. Interestingly, this relatively simple system is asymptotically free. In the massless limit, it undergoes dimensional transmutation and it possesses an infrared conformal fixed point. Thus it can be used to illustrate nontrivial concepts of quantum field theory in the simpler framework of relativistic quantum mechanics.
Resumo:
PURPOSE The range of patient setup errors in six dimensions detected in clinical routine for cranial as well as for extracranial treatments, were analyzed while performing linear accelerator based stereotactic treatments with frameless patient setup systems. Additionally, the need for re-verification of the patient setup for situations where couch rotations are involved was analyzed for patients treated in the cranial region. METHODS AND MATERIALS A total of 2185 initial (i.e. after pre-positioning the patient with the infrared system but before image guidance) patient setup errors (1705 in the cranial and 480 in the extracranial region) obtained by using ExacTrac (BrainLAB AG, Feldkirchen, Germany) were analyzed. Additionally, the patient setup errors as a function of the couch rotation angle were obtained by analyzing 242 setup errors in the cranial region. Before the couch was rotated, the patient setup error was corrected at couch rotation angle 0° with the aid of image guidance and the six degrees of freedom (6DoF) couch. For both situations attainment rates for two different tolerances (tolerance A: ± 0.5mm, ± 0.5°; tolerance B: ± 1.0 mm, ± 1.0°) were calculated. RESULTS The mean (± one standard deviation) initial patient setup errors for the cranial cases were -0.24 ± 1.21°, -0.23 ± 0.91° and -0.03 ± 1.07° for the pitch, roll and couch rotation axes and 0.10 ± 1.17 mm, 0.10 ± 1.62 mm and 0.11 ± 1.29 mm for the lateral, longitudinal and vertical axes, respectively. Attainment rate (all six axes simultaneously) for tolerance A was 0.6% and 13.1% for tolerance B, respectively. For the extracranial cases the corresponding values were -0.21 ± 0.95°, -0.05 ± 1.08° and -0.14 ± 1.02° for the pitch, roll and couch rotation axes and 0.15 ± 1.77 mm, 0.62 ± 1.94 mm and -0.40 ± 2.15 mm for the lateral, longitudinal and vertical axes. Attainment rate (all six axes simultaneously) for tolerance A was 0.0% and 3.1% for tolerance B, respectively. After initial setup correction and rotation of the couch to treatment position a re-correction has to be performed in 77.4% of all cases to fulfill tolerance A and in 15.6% of all cases to fulfill tolerance B. CONCLUSION The analysis of the data shows that all six axes of a 6DoF couch are used extensively for patient setup in clinical routine. In order to fulfill high patient setup accuracies (e.g. for stereotactic treatments), a 6DoF couch is recommended. Moreover, re-verification of the patient setup after rotating the couch is required in clinical routine.