909 resultados para One-way Quantum Computer


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The equivalence of the noncommutative U(N) quantum field theories related by the θ-exact Seiberg-Witten maps is, in this paper, proven to all orders in the perturbation theory with respect to the coupling constant. We show that this holds for super Yang-Mills theories with N=0, 1, 2, 4 supersymmetry. A direct check of this equivalence relation is performed by computing the one-loop quantum corrections to the quadratic part of the effective action in the noncommutative U(1) gauge theory with N=0, 1, 2, 4 supersymmetry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tese (doutorado)—Universidade de Brasília, Instituto de Psicologia, Programa de Pós-Graduação em Processos de Desenvolvimento Humano e Saúde, 2016.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Career Academy instructors’ technical literacy is vital to the academic success of students. This nonexperimental ex post facto study examined the relationships between the level of technical literacy of instructors in career academies and student academic performance. It was also undertaken to explore the relationship between the pedagogical training of instructors and the academic performance of students. Out of a heterogeneous population of 564 teachers in six targeted schools, 136 teachers (26.0 %) responded to an online survey. The survey was designed to gather demographic and teaching experience data. Each demographic item was linked by researchers to teachers’ technology use in the classroom. Student achievement was measured by student learning gains as assessed by the reading section of the FCAT from the previous to the present school year. Linear and hierarchical regressions were conducted to examine the research questions. To clarify the possibility of teacher gender and teacher race/ethnic group differences by research variable, a series of one-way ANOVAs were conducted. As revealed by the ANOVA results, there were not statistically significant group differences in any of the research variables by teacher gender or teacher race/ethnicity. Greater student learning gains were associated with greater teacher technical expertise integrating computers and technology into the classroom, even after controlling for teacher attitude towards computers. Neither teacher attitude toward technology integration nor years of experience in integrating computers into the curriculum significantly predicted student learning gains in the regression models. Implications for HRD theory, research, and practice suggest that identifying teacher levels of technical literacy may help improve student academic performance by facilitating professional development strategies and new parameters for defining highly qualified instructors with 21st century skills. District professional development programs can benefit by increasing their offerings to include more computer and information communication technology courses. Teacher preparation programs can benefit by including technical literacy as part of their curriculum. State certification requirements could be expanded to include formal surveys to assess teacher use of technology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This panel will discuss key aspects of knowledge management (KM) education in response to challenges posed by the necessity to improve KM as a discipline and an established professional field. Through panelists' thought-provoking presentations and interactions with the audience, the discussion will address KM education from the starting why, what, who, where and when perspectives to the end result and understanding of how to approach KM education in the future.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study of ultra-cold atomic gases is one of the most active field in contemporary physics. The main motivation for the interest in this field consists in the possibility to use ultracold gases to simulate in a controlled way quantum many-body systems of relevance to other fields of physics, or to create novel quantum systems with unusual physical properties. An example of the latter are Bose-Fermi mixtures with a tunable pairing interaction between bosons and fermions. In this work, we study with many-body diagrammatic methods the properties of this kind of mixture in two spatial dimensions, extending previous work for three dimensional Bose-Fermi mixtures. At zero temperature, we focus specifically on the competition between boson condensation and the pairing of bosons and fermions into molecules. By a numerical solution of the main equations resulting by our many-body diagrammatic formalism, we calculate and present results for several thermodynamic quantities of interest. Differences and similarities between the two-dimensional and three-dimensional cases are pointed out. Finally, our new results are applied to discuss a recent proposal for creating a p-wave superfluid in Bose-Fermi mixtures with the fermionic molecules which form for sufficiently strong Bose-Fermi attraction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract The aim of this study was to evaluate three transfer techniques used to obtain working casts of implant-supported prostheses through the marginal misfit and strain induced to metallic framework. Thirty working casts were obtained from a metallic master cast, each one containing two implant analogues simulating a clinical situation of three-unit implant-supported fixed prostheses, according to the following transfer impression techniques: Group A, squared transfers splinted with dental floss and acrylic resin, sectioned and re-splinted; Group B, squared transfers splinted with dental floss and bis-acrylic resin; and Group N, squared transfers not splinted. A metallic framework was made for marginal misfit and strain measurements from the metallic master cast. The misfit between metallic framework and the working casts was evaluated with an optical microscope following the single-screw test protocol. In the same conditions, the strain was evaluated using strain gauges placed on the metallic framework. The data was submitted to one-way ANOVA followed by the Tukey's test (α=5%). For both marginal misfit and strain, there were statistically significant differences between Groups A and N (p<0.01) and Groups B and N (p<0.01), with greater values for the Group N. According to the Pearson's test, there was a positive correlation between the variables misfit and strain (r=0.5642). The results of this study showed that the impression techniques with splinted transfers promoted better accuracy than non-splinted one, regardless of the splinting material utilized.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A proper cast is essential for a successful rehabilitation with implant prostheses, in order to produce better structures and induce less strain on the implants. The aim of this study was to evaluate the precision of four different mold filling techniques and verify an accurate methodology to evaluate these techniques. A total of 40 casts were obtained from a metallic matrix simulating three unit implant-retained prostheses. The molds were filled using four different techniques in four groups (n = 10): Group 1 - Single-portion filling technique; Group 2 - Two-step filling technique; Group 3 - Latex cylinder technique; Group 4 - Joining the implant analogs previously to the mold filling. A titanium framework was obtained and used as a reference to evaluate the marginal misfit and tension forces in each cast. Vertical misfit was measured with an optical microscope with an increase of 120 times following the single-screw test protocol. Strain was quantified using strain gauges. Data were analyzed using one-way ANOVA (Tukey's test) (α =0.05). The correlation between strain and vertical misfit was evaluated by Pearson test. The misfit values did not present statistical difference (P = 0.979), while the strain results showed statistical difference between Groups 3 and 4 (P = 0.027). The splinting technique was considered to be as efficient as the conventional technique. The strain gauge methodology was accurate for strain measurements and cast distortion evaluation. There was no correlation between strain and marginal misfit.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the degree of conversion (DC) and the cytotoxicity of photo-cured experimental resin composites containing 4-(N,N-dimethylamino)phenethyl alcohol (DMPOH) combined to the camphorquinone (CQ) compared with ethylamine benzoate (EDAB). The resin composites were mechanically blended using 35 wt% of an organic matrix and 65 wt% of filler loading. To this matrix was added 0.2 wt% of CQ and 0.2 wt% of one of the reducing agents tested. 5x1 mm samples (n=5) were previously submitted to DC measurement and then pre-immersed in complete culture medium without 10% (v/v) bovine serum for 1 h or 24 h at 37 °C in a humidifier incubator with 5% CO2 and 95% humidity to evaluate the cytotoxic effects of experimental resin composites using the MTT assay on immortalized human keratinocytes cells. As a result of absence of normal distribution, the statistical analysis was performed using the nonparametric Kruskal-Wallis to evaluate the cytotoxicity and one-way analysis of variance to evaluate the DC. For multiple comparisons, cytotoxicity statistical analyses were submitted to Student-Newman-Keuls and DC analysis to Tukey's HSD post-hoc test (=0.05). No significant differences were found between the DC of DMPOH (49.9%) and EDAB (50.7%). 1 h outcomes showed no significant difference of the cell viability between EDAB (99.26%), DMPOH (94.85%) and the control group (100%). After 24 h no significant difference were found between EDAB (48.44%) and DMPOH (38.06%), but significant difference was found compared with the control group (p>0.05). DMPOH presented similar DC and cytotoxicity compared with EDAB when associated with CQ.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article aimed at comparing the accuracy of linear measurement tools of different commercial software packages. Eight fully edentulous dry mandibles were selected for this study. Incisor, canine, premolar, first molar and second molar regions were selected. Cone beam computed tomography (CBCT) images were obtained with i-CAT Next Generation. Linear bone measurements were performed by one observer on the cross-sectional images using three different software packages: XoranCat®, OnDemand3D® and KDIS3D®, all able to assess DICOM images. In addition, 25% of the sample was reevaluated for the purpose of reproducibility. The mandibles were sectioned to obtain the gold standard for each region. Intraclass coefficients (ICC) were calculated to examine the agreement between the two periods of evaluation; the one-way analysis of variance performed with the post-hoc Dunnett test was used to compare each of the software-derived measurements with the gold standard. The ICC values were excellent for all software packages. The least difference between the software-derived measurements and the gold standard was obtained with the OnDemand3D and KDIS3D (-0.11 and -0.14 mm, respectively), and the greatest, with the XoranCAT (+0.25 mm). However, there was no statistical significant difference between the measurements obtained with the different software packages and the gold standard (p> 0.05). In conclusion, linear bone measurements were not influenced by the software package used to reconstruct the image from CBCT DICOM data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To adapted the critical velocity (CV), RAST test and lactate minimum (LM) to evaluation of female basketball players. METHODS: Twelve well-trained female basketball players (19 ± 1yrs) were submitted to four intensities running (10 - 14 km/h) at shuttle exercise until exhaustion, applied on alternate days. The linear model 'velocity vs. 1/tlim' was adopted to determine the aerobic (CV) and anaerobic (CCA) parameters. The lactate minimum test consisted of two phases: 1) hiperlactatemia induction using the RAST test and 2) incremental test composed by five shuttle run (20-m) at 7, 8, 9, 10, and 12 km/h. Blood samples were collected at the end of each stage. RESULTS: The velocity (vLM) and blood lactate concentration at LM were obtained by two polynomial adjustments: lactate vs. intensity (LM1) and lactate vs. time (LM2). ANOVA one-way, Student t-test and Pearson correlation were used for statistical analysis. The CV was obtained at 10.3 ± 0.2 km/h and the CCA estimated at 73.0 ± 3.4 m. The RAST was capable to induce the hiperlactatemia and to determine the Pmax (3.6 ± 0.2 W/kg), Pmed (2.8 ± 0.1 W/kg), Pmin (2.3 ± 0.1 W/kg) and FI (30 ± 3%). The vLM1 and vLM2 were obtained, respectively, at 9.47 ±0.13 km/h and 9.8 ± 0.13 km/h, and CV was higher than vLM1. CONCLUSION: The results suggest that the non-invasive model can be used to determine the aerobic and anaerobic parameters. Furthermore, the LM test adapted to basketball using RAST and progressive phase was effective to evaluate female athletes considering the specificity of modality, with high success rates observed in polynomial adjustment 'lactate vs. time' (LM2).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física