257 resultados para OPACITY


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the advent of high frequency transducers, the use of ocular ultrasound has become widely used because it provides definitions of major ocular structures. This diagnostic tool is useful in the evaluation of ophthalmic injuries, and also used for qualitative and quantitative evaluation of intraocular and orbital lesions. It is a noninvasive, safe and fast, easy to use and can be performed in an awake animal. The ocular ultrasonography is indicated in cases of ocular opacity, when the ophthalmic examination cannot be done, and in eyes with ocular trauma or suspected orbital disease. Ultrasound biomicroscopy (UBM) is a diagnostic tool with high cost and sedation or general anesthesia is necessary, but has the advantage of evaluating structures poorly defined or visualized in the anterior segment of the eye. Therefore, this paper aims to show the importance of ocular ultrasonography and UBM to veterinary practitioners, and to demonstrate its advantages and indications in ophthalmic routine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aims, by a literature review, to evaluate the effects of the phacoemulsification surgery into the endothelial cells of the cornea, especially on dogs. The phacoemulsification is a surgical technique of cataract surgery, and presents a series of factors pre, trans and post operation that can affect the cornea endothelium. Knowing that the cornea transparency is essential to the preservation of the visual acuity, and that the endothelium cells do not demonstrate an adequate regeneration, it is important to the surgeon to be aware of these factors in order to avoid or to minimize them. Among then can be mentioned: previous diseases, surgical and chemical trauma, intra-ocular lens, uveitis etc. As consequence, a reduction on the number of endothelium cells and edema can be observed, which can lead to a loss of vision by definitive cornea opacity or to late visual recuperation

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cataract is the leading cause of blindness in dogs. It is defined as an opacity in the lens and is independent of resulting visual deficit. Although there are a growing number of studies related to drug therapy of cataract, the treatment is still considered exclusively surgical. Among the techniques used to remove cataract, phacoemulsification is the best performer. Anesthesia in intraocular surgery has several peculiarities, which are essential to successfully conduct phacoemulsification in dogs. In these patients, a safe and effective anesthesia requires the maintenance of intraocular pressure close to normal, preventing the activation of the oculo-cardiac reflex and complete immobilization of the eye. The appropriate conditions for such surgical procedures can be established through the use of drugs from different pharmacological groups for premedication, induction and maintenance of anesthesia, making a balanced anesthesia. This work was compiled from a careful review of the literature on anesthesia in cataract surgery. Considerations on the pre-medication, induction and maintenance of anesthesia are discussed, aiming to contribute to the phacoemulsification becomes more safe and suitable for the anesthesiologist and the surgeon as well as comfortable for dogs undergoing surgery

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper aims at examining the hypothesis that the choice among the different strategies of relativization available in the Portuguese grammar is motivated by a lesser or greater degree of transparency between form and meaning, which implies, correlatively, lesser or greater degree of ease in cognitive processing. In addition, the lesser or greater degree of transparency allows to postulate a hierarchical ordering for the strategies in correspondence to a greater or a lesser degree of ease in cognitive processing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Ciência do Solo) - FCAV

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article aims to investigate the configuration on the new scenario, during the Early German Romanticism, which led to dismantle the philosophical discourse as the expression of a safe and fixed content, free from the ambiguity of figural language. Our main argument is that already Schelling’s concept of symbol brings up the question about the opacity of the text. By analyzing to what extent this problematization around the language lingers on in the contemporariness, we refer to Derrida’s thought which points out to the illusion embedded in the pretension to conceive a clear and unambiguous language, creating therefore a new ground between art and philosophy since the text itself as a neutral and closed subject will be questioned now.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ocular surface diseases are often diagnosed in brachycephalic dogs. The ophthalmic parameters of the Shih Tzu dogs are evaluated in this study since this breed is among the most commonly affected by these diseases. In this study, ophthalmic parameters of this breed were partly studied under physical restraint. Schirmer tear test, breakup time test, aesthesiometry, biomicroscopy, non-contact specular microscopy, laser flaremetry, applanation tonometry, ultrasonography and ophthalmoscopy were carried in 48 eyes of 24 male and female dogs, aged from two to four years, weighing between 5 and 10kg. All dogs were from a breeding kennel. Descriptive statistics were applied to the data. Mean and standard error for Schirmer tear test was 26.145±0.803mm min-1; breakup time test, 13.668±0.538s; and aesthesiometry, 2.395±0.071cm. The biomicroscopy evaluation showed that 70.83% of the eyes had medial entropion; 42% caruncular trichiasis; 33% distichiasis, 27% mild paracentral corneal opacity; and 13% corneal melanosis. Mean and standard error for endothelial cell density was 2221.591±20.161cells mm-2; endothelial cell hexagonality, 63.770±1.805%; endothelial cell area, 451.895±4.179mm2; central corneal thickness, 0.490±0.007 mm; laser flaremetry, 1.720±0.216PC ms-1; applanation tonometry, 16.118±0.460mmHg; axial length, 20.255±0.134mm; lens thickness, 6.624±0.031mm; anterior chamber, 4.064±0.109mm; and vitreous chamber, 9.565±0.054mm. Ophthalmoscopy findings were not different from previous reports for other breeds. The results showed that the ophthalmic Shih Tzu parameters did not differ from other breeds according to data in the literature, except for the breakup time and Cochet-Bonnet aesthesiometry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A wavelength-routed optical network consists of multi-wavelength crossconnect switches (XCSs) which are interconnected by optical fibers. Some (or all) crossconnects, referred to as nodes in this paper, are also attached to access stations where data from several end-users could be multiplexed onto a single wavelength division multiplexed (WDM) channel. An access station provides optical-to-electronic (O/E) conversion and wice wersa to interface the optical network with conventional electronic equipment. The access station, at an intermediate node, may also be used (as in this study) for signal regenerution on a lightpath. A new call is admitted into the network if a lightpath (a set of free wavelengths along a given route from source to destination) can be established between the call’s source and destination stations. Depending on the number of all-optical fragments in a single lightpath, three different approaches may be employed to operate such a network. These approaches are: transparency, opacity, and translucency (to be explained below). Our study concentrates on evaluating the relative merits of these three approaches in a sample network environment.