925 resultados para NM LASER
Resumo:
The aim of this study was to investigate the immediate effects of laser therapy on neuromuscular performance in healthy subjects after a muscle fatigue. This is a clinical trial, controlled, randomized, blinded, attended by 80 volunteers of both genders, healthy, with ages between 18 to 28 years. Initially the volunteers performed an initial evaluation (EV1) using electromyography in the biceps muscle, associated with assessment in isokinetic dynamometry with 5 concentric contractions (60 °/s) for elbow flexion. The subjects were randomly allocated into 4 groups: G1 (control, n = 20), G2 (placebo, n = 20), G3 (pre-fatigue laser, n = 20), and G4 (post fatigue laser, n = 20). The muscular fatigue protocol had 30 concentric isokinetic contractions (120 °/s). We used a 808 nm laser, power of 100 mW, applied at the belly of the biceps muscle. After the speeches the volunteers performed a final evaluation (EV2). Test was applied to two-way ANOVA with post hoc Turkey, with a significance level of 5%. There was no significant difference in electromyographic evaluation. In dynamometric evaluation showed a drop in peak torque, peak torque normalized to body weight (p <0.001) and average power (p <0, 05) between the initial and final evaluations in control. Among the groups there was a significant difference between the control and the other groups in relation to peak torque (p <0.05), peak torque to body weight (p <0.001) and average power (p <0.05). Therefore, the low intensity laser therapy does not alter the immediate neuromuscular performance after fatigue
Resumo:
Photoluminescence data of Eu-doped SnO(2) xerogels are presented, yielding information on the symmetry of Eu(3+) luminescent centers, which can be related to their location in the matrix: at lattice sites, substituting to Sn(4+), or segregated at particles surface. Influence of doping concentration and/or particle size on the photoluminescence spectra obtained by energy transfer from the matrix to Eu(3+) sites is investigated. Results show that a better efficiency in the energy transfer processes is obtained for high symmetry Eu(3+) sites and low doping levels. Emission intensity from (5)D(0) -> (7)F(1) transition increases as the temperature is raised from 10 to 240 K, under excitation at 266 nm laser line, because in this transition the multiphonon emission becomes significant only above 240 K. As an extension of this result, we predict high effectiveness for room temperature operation of Eu-based optical communication devices. X-ray diffraction data show that the impurity excess inhibits particle growth, which may influence the asymmetry ratio of luminescence spectra.
Resumo:
Multicolor and white light emissions have been achieved in Yb3+, Tm3+ and Ho3+ triply doped heavy metal oxide glasses upon laser excitation at 980 nm. The red (660 nm), green (547 nm) and blue (478 nm) up conversion emissions of the rare earth (RE) ions triply doped TeO2-GeO2-Bi2O3-K2O glass (TGBK) have been investigated as a function of the RE concentration and excitation power of the 980 nm laser diode. The most appropriate combination of RE in the TGBK glass host (1.6 wt% Yb2O3, 0.6 wt% Tm2O3 and 0.1 wt% Ho2O3) has been determined with the purpose to tune the primary colors (RGB) respective emissions and generate white light emission by varying the pump power. The involved infrared to visible up conversion mechanisms mainly consist in a three-photon blue up conversion of Tm3+ ions and a two-photon green and red up conversions of Ho3+ ions. The resulting multicolor emissions have been described according to the CIE-1931 standards. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
The vibrational spectra of palladium phthalocyanine (PdPc) evaporated thin solid films are reported, including the resonance Raman scattering, surface-enhanced resonance Raman scattering (SERRS) and SERRS mapping of the film surface using micro-Raman spectroscopy with 633 nm laser radiation. SERRS of PdPc was obtained by evaporating an overlayer of Ag nanoparticles on to the PdPc film on glass. The SERRS enhancement factor is estimated as similar to10(4) with reference to PdPc evaporated films on glass. The molecular organization of the PdPc evaporated films was probed using transmission and reflection-absorption infrared spectra. It was established that a random molecular distribution found in PdPc evaporated films is independent of temperature. No evidence of thermal degradation due to thermal annealing was found in the films. Electronic absorption and emission spectra are also discussed. Copyright (C) 2002 John Wiley Sons, Ltd.
Resumo:
This work reports on the preparation, structural and luminescent studies of nanosized up-converter phosphors Y2O2S:Yb(4%), Er(0.1%) and Y2O2S:Yb(4%), Tm(0.1%),both from polymeric and basic carbonate precursors. The precursors were submitted to a sulphuration process that was previously developed for oxysulfide preparation from basic carbonate. From XRD data, all phosphors presented the oxysulfide phase and the mean crystallite size estimated from the Scherrer formula in the range of 15-20 nm. Polymeric precursor leads to the smallest crystallite size independent on the doping ion. SEM and TEM results confirmed that basic carbonate leads to spherical particles with narrow size distribution and mean diameter of 150 nm, and polymeric precursor smaller spherical particles with diameter between 20 and 40 nm. Up-conversion studies under 980 nm laser excitation showed that Er-doped phosphors present strong green emission related to H-2(11/2), S-4(3/2) --> I-4(15/2) Er transitions as well as the red ones, F-4(9/2) --> I-4(15/2). Tm-doped samples show strong blue emission assigned to (1)G(4) --> H-3(6) and also the red ones, related to (1)G(4) --> F-3(4). Therefore, the sulphuration method was successfully applied to prepare nanosized and nanostructured blue and green up-converter oxysulfide phosphors starting from basic carbonate and polymeric precursors. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
We propose a mathematical model for the movement in absorbing materials of photorefractive holograms under feedback constraints. We use this model to analyze the speed of a fringe-locked running hologram in photorefractive sillenite crystals that usually exhibit a strong absorption effect. Fringe-locked experiments permit us to compute the quantum efficiency for the photogeneration of charge carriers in photorefractive crystals if the effect of bulk absorption and the effective value of the externally applied field are adequately taken into consideration. A Bi12TiO20 sample was measured with the 532-nm laser wavelength, and a quantum efficiency of φ = 0.37 was obtained. Disregarding absorption leads to large errors in φ. © 2000 Optical Society of America.
Resumo:
Fluorescence diagnosis of malignant lesions has been showed as an attractive optical technique due especially to its real-time response and a more objective and quantitative evaluation. Even though the oral cavity allows a direct examination many lesions are diagnosed when it is already in advanced stage, compromising the patient prognosis. In this study, the fluorescence spectroscopy was used to the detection of chemically induced carcinoma at the lateral border of the tongue in a hamster model. Two excitations wavelengths in visible region were applied: 442 and 532 nm. All the spectra results were analyzed comparing with the histopathological diagnosis. The better results were achieved with the 442 nm laser excitation. The spectra from carcinoma showed new emission bands and these were used to determined different ratios for a quantitative analysis. Using the 625-645 nm fluorescence range under 442 nm excitation (A3 coefficient) the percentage of false negative was of 9.1%, however the false positive percentage was of 18.5%. The 532 nm excitation provided a better normal tissue detection compared to 442 nm excitation. The ideal clinical condition is probably the use of multiple wavelengths excitation for a broader tissue fluorescence investigation.
Resumo:
Ethanol with added water may be found during the process of assessing its physical and chemical properties. This addition can damage automotive vehicle engines and also may contribute to tax evasion. The present contribution describes a method based on a photothermal transparent transducer to determine the water content in ethanol. A chamber with a window of lithium tantalate coated with a thin layer of indium tin oxide was used, and a 1450-nm laser diode was employed as the excitation source. The results indicated a nearly linear response of the apparatus, as a function of the water content in water/ethanol solutions ranging from 0 to 100 (vol.%). The results for the dependency of the photothermal signal on the laser power and chopping frequency suggested that reliable results can be obtained using laser power and chopping rates above 100 mW and 10 Hz, respectively. The results reported here may be useful in the development of an alternative method that can provide real-time data on the water concentration in ethanol in a rapid, portable and unambiguous way, and that can be easily used in laboratory analyses or in gas stations. © 2013 Elsevier B.V.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
New Yb3+, Er3+ and Tm3+ doped fluoro-phosphate glasses belonging to the system NaPO3–YF3–BaF2–CaF2 and containing up to 10 wt% of rare-earth ion fluorides were prepared and characterized by differential scanning calorimetry, absorption spectroscopy and up-conversion emission spectroscopy under excitation with a 975 nm laser diode. Transparent and homogeneous glass-ceramics have been reproducibly obtained with a view to manage the red, green and blue emission bands and generate white light. X-ray diffraction as well as electron microscopy techniques have confirmed the formation of fluorite-type cubic nanocrystals at the beginning of the crystallization process while complex nanocrystalline phases are formed after a longer heat-treatment. The prepared glass-ceramics exhibit high optical transparency even after 170 h of thermal treatment. An improvement of up-conversion emission intensity – from 10 to 160 times larger – was measured in the glass-ceramics when compared to the parent glass, suggesting an important incorporation of the rare-earth ions into the crystalline phase(s). The involved mechanisms and lifetime were described in detail as a function of heat-treatment time. Finally, a large range of designable color rendering (from orange to turquoise through white) can be observed in these materials by controlling the laser excitation power and the crystallization rate.
Resumo:
The LA-MC-ICP-MS method applied to U-Pb in situ dating is still rapidly evolving due to improvements in both lasers and ICP-MS. To test the validity and reproducibility of the method, 5 different zircon samples, including the standard Temora-2, ranging in age between 2.2 Ga and 246 Ma, were dated using both LA-MC-ICP-MS and SHRIMP. The selected zircons were dated by SHRIMP and, after gentle polishing, the laser spot was driven to the same site or on the same zircon phase with a 213 nm laser microprobe coupled to a multi-collector mixed system. The data were collected with a routine spot size of 25 μm and, in some cases, of 15 and 40 μm. A careful cross-calibration using a diluted U-Th-Pb solution to calculate the Faraday reading to counting rate conversion factors and the highly suitable GJ-1 standard zircon for external calibrations were of paramount importance for obtaining reliable results. All age results were concordant within the experimental errors. The assigned age errors using the LA-MC-ICP-MS technique were, in most cases, higher than those obtained by SHRIMP, but if we are not faced with a high resolution stratigraphy, the laser technique has certain advantages.
Resumo:
Laboratory measurements of the rate coefficient for quenching of O3(nu2) by ground-state atomic oxygen, kO(nu2), at room temperature are presented. kO(nu2) is currently not well known and is necessary for appropriate nonlocal thermodynamic equilibrium modeling of the upper mesosphere and lower thermosphere. In this work, a 266 nm laser pulse photolyzes a small amount of O3 in a slow-flowing gas mixture of O3, Xe, and Ar. This process simultaneously produces atomic oxygen and increases the temperature of the gas mixture slightly, thereby increasing the population in the O3(nu2) state. Transient diode laser absorption spectroscopy is used to monitor the populations of the O3(nu2) and ground vibrational states as the system re-equilibrates. Relaxation rates are measured over a range of quencher concentrations to extract the rate coefficient of interest. The value of kO(nu2) was determined to be (2.2 0.5) * 10(-12) cm(3) s(-1).
Resumo:
PURPOSE The purpose of this study was to describe autofluorescence lifetime characteristics in Stargardt disease (STGD) using fluorescence lifetime imaging ophthalmoscopy (FLIO) and to investigate potential prognostic markers for disease activity and progression. METHODS Fluorescence lifetime data of 16 patients with STGD (mean age, 40 years; range, 22-56 years) and 15 age-matched controls were acquired using a fluorescence lifetime imaging ophthalmoscope based on a Heidelberg Engineering Spectralis system. Autofluorescence was excited with a 473-nm laser, and decay times were measured in a short (498-560 nm) and long (560-720 nm) spectral channel. Clinical features, autofluorescence lifetimes and intensity, and corresponding optical coherence tomography images were analyzed. One-year follow-up examination was performed in eight STGD patients. Acquired data were correlated with in vitro measured decay times of all-trans retinal and N-retinylidene-N-retinylethanolamine. RESULTS Patients with STGD displayed characteristic autofluorescence lifetimes within yellow flecks (446 ps) compared with 297 ps in unaffected areas. In 15% of the STGD eyes, some flecks showed very short fluorescence lifetimes (242 ps). Atrophic areas were characterized by long lifetimes (474 ps), with some remaining areas of normal to short lifetimes (322 ps) toward the macular center. CONCLUSIONS Patients with recent disease onset showed flecks with very short autofluorescence lifetimes, which is possible evidence of accumulation of retinoids deriving from the visual cycle. During the study period, many of these flecks changed to longer lifetimes, possibly due to accumulation of lipofuscin. Therefore, FLIO might serve as a useful tool for monitoring of disease progression. (ClinicalTrials.gov number, NCT01981148.).
Resumo:
Objetivos : Analizar la distribución de energía en un tejido cuando se emplea terapia por láser de baja potencia y estudiar las especificaciones mínimas de equipos de terapia láser para estimar la dosis. Material y métodos: Se ha empleado el método de Monte Carlo para obtener la distribución de energía absorbida por la piel para dos tipos de láser y la teoría de la difusión para estimar la longitud de penetración y el recorrido libre medio. Se ha estudiado la variación de esa distribución en función de la raza (caucásico, asiático, afroamericano) y para dos localizaciones anatómicas distintas. Se ha analizado la información facilitada por diversos fabricantes de equipos comerciales para determinar si es necesario adaptar la dosimetría recomendada. Resultados: La radiación láser infrarroja (810nm) se absorbe mayoritariamente en un espesor de piel de 1,9±0,2mm para caucásicos, entre 1,73±0,08mm (volar del antebrazo) y 1,80±0,11mm (palma) para asiáticos y entre 1,25±0,09mm (volar del antebrazo) y 1,65±0,2mm (palma) para afroamericanos. El recorrido libre medio de la luz siempre es menor que 0,69±0,09mm. Para los equipos comerciales analizados la única característica geométrica del haz láser que se menciona es la superficie que oscila entre 0,08 y 1cm2, pero no se especifica cómo es la distribución de energía, la divergencia del haz, forma de la sección transversal, etc. Conclusiones:Dependiendo del equipo de terapia por láser de baja potencia utilizado, el tipo de paciente y la zona a tratar, el clínico debe adaptar las dosis recomendadas. Abstract: Objectives: To analyze the distribution of energy deposited in a tissue when this is irradiated with a low power laser and to study the minimum characteristics that manufacturers of low power laser therapy equipments should include to estimate the dosage. Material and methods: Monte Carlo simulation was performed to determine the absorption location of the laser energy. The diffusion theory was used to estimate penetration depth and mean free path. Variation of this distribution was studied based on three different skin types (Caucasians, Asians and Afroamericans) and for two different anatomic locations: palm and volar forearm. Information given by several manufactures of low power laser therapy equipments has been analyzed. Results: Infrared (810 nm) laser radiation is mainly absorbed in a skin layer of thickness 1.9±0.2mm for Caucasians, from 1.73±0.08mm (volar forearm) to 1.80±0.11mm (palm) for Asians, and from 1.25±0.09mm (volar forearm) to 1.65±0.2mm (palm) for Afroamericans. The light mean free path is lower than 0.69±0.09mm for all cases. The laser beam characteristics (beam shape, energy distribution on a transversal section, divergence, incidence angle,etc.) are not usually specified by the manufacturers. Only beam size (ranging from 0.08 to 1cm2) is given in some cases. Discussion and conclusions: Depending on the low power laser therapy equipment, on the patient and on the anatomic area to be treated, the staff should adapt the recommended dosage for each individual case.