972 resultados para Mobile measurement reports


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A target irradiated with a high power laser pulse, blows off a large amount of charge and as a consequence the target itself becomes a generator of electromagnetic pulses (EMP) owing to high return current flowing to the ground through the target holder. The first measurement of the magnetic field induced by the neutralizing current reaching a value of a few kA was performed with the use of an inductive target probe at the PALS Laser Facility (Cikhardt et al. Rev. Sci. Instrum. 85 (2014) 103507). A full description of EMP generation should contain information on the spatial distribution and temporal variation of the electromagnetic field inside and outside of the interaction chamber. For this reason, we consider the interaction chamber as a resonant cavity in which different modes of EMP oscillate for hundreds of nanoseconds, until the EMP is transmitted outside through the glass windows and EM waves are attenuated. Since the experimental determination of the electromagnetic field distribution is limited by the number of employed antennas, a mapping of the electromagnetic field has to be integrated with numerical simulations. Thus, this work reports on a detailed numerical mapping of the electromagnetic field inside the interaction chamber at the PALS Laser Facility (covering a frequency spectrum from 100 MHz to 3 GHz) using the commercial code COMSOL Multiphysics 5.2. Moreover we carried out a comparison of the EMP generated in the parallelepiped-like interaction chamber used in the Vulcan Petawatt Laser Facility at the Rutherford Appleton Laboratory, against that produced in the spherical interaction chamber of PALS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article reports the findings from the first UK study to examine the use of mobile phones by looked after children. Contact with family and friends is important, but it has sometimes to be carefully managed to avoid unintended consequences such as placement instability. The study examined the ways in which mobile phone technology impacts on contact, drawing on the experiences of children and young people in foster-care and residential care, and of policy makers, social workers, foster parents and residential care staff. No guidance was available that addressed the issue of mobile phone contact arrangements for looked after children and young people. Three years on from the start of the study, this remains the case in the area where the study was conducted, resulting in variation in the way mobile phone use for contact is managed; the issue appears only to be specifically addressed when identified as a problem. The position of mobile phone facilitated contact as a recognised form of contact requires review. The evidence suggests it should routinely form part of children’s care plans, and that residential staff and foster parents need to be adequately prepared and supported for the dynamics of mobile phone facilitated contact.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This report is the sixth in a series of annual reports which use National Child Measurement Programme (NCMP) data to examine changes in children’s body mass index (BMI) that have taken place since 2006/07. It explores trends in obesity, overweight, excess weight and underweight prevalence, as well as changes in mean BMI over time. Trends within different socioeconomic and ethnic groups are also examined to determine whether existing health inequalities are widening or becoming smaller.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Quantum sensors based on coherent matter-waves are precise measurement devices whose ultimate accuracy is achieved with Bose-Einstein condensates (BECs) in extended free fall. This is ideally realized in microgravity environments such as drop towers, ballistic rockets and space platforms. However, the transition from lab-based BEC machines to robust and mobile sources with comparable performance is a challenging endeavor. Here we report on the realization of a miniaturized setup, generating a flux of 4x10(5) quantum degenerate Rb-87 atoms every 1.6 s. Ensembles of 1 x 10(5) atoms can be produced at a 1 Hz rate. This is achieved by loading a cold atomic beam directly into a multi-layer atom chip that is designed for efficient transfer from laser-cooled to magnetically trapped clouds. The attained flux of degenerate atoms is on par with current lab-based BEC experiments while offering significantly higher repetition rates. Additionally, the flux is approaching those of current interferometers employing Raman-type velocity selection of laser-cooled atoms. The compact and robust design allows for mobile operation in a variety of demanding environments and paves the way for transportable high-precision quantum sensors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis reports on the development of quantitative measurement using micromachined scanning thermal microscopy (SThM) probes. These thermal probes employ a resistive element at their end, which can be used in passive or active modes. With the help of a review of SThM, the current issues and potentials associated with this technique are revealed. As a consequence of this understanding, several experimental and theoretical methods are discussed, which expand our understanding of these probes. The whole thesis can be summarized into three parts, one focusing on the thermal probe, one on probe-sample thermal interactions, and the third on heat transfer within the sample. In the first part, a series of experiments are demonstrated, aimed at characterizing the probe in its electrical and thermal properties, benefiting advanced probe design, and laying a fundamental base for quantifying the temperature of the probe. The second part focuses on two artifacts observed during the thermal scans – one induced by topography and the other by air conduction. Correspondingly, two devices, probing these artifacts, are developed. A topography-free sample, utilizing a pattern transfer technique, minimises topography-related artifacts that limited the reliability of SThM data; a controlled temperature ‘Johnson noise device’, with multiple-heater design, offers a uniform, accurate, temperature distribution. Analyzing results of scan from these samples provides data for studying the thermal interactions within the probe and the tip-sample interface. In the final part, the observation is presented that quantification of measurements depends not only on an accurate measurement tool, but also on a deep understanding of the heat transfer within the sample resulting from the nanoscopic contact. It is believed that work in this thesis contributes to SThM gaining wider application in the scientific community.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent advances in mobile phone cameras have poised them to take over compact hand-held cameras as the consumer’s preferred camera option. Along with advances in the number of pixels, motion blur removal, face-tracking, and noise reduction algorithms have significant roles in the internal processing of the devices. An undesired effect of severe noise reduction is the loss of texture (i.e. low-contrast fine details) of the original scene. Current established methods for resolution measurement fail to accurately portray the texture loss incurred in a camera system. The development of an accurate objective method to identify the texture preservation or texture reproduction capability of a camera device is important in this regard. The ‘Dead Leaves’ target has been used extensively as a method to measure the modulation transfer function (MTF) of cameras that employ highly non-linear noise-reduction methods. This stochastic model consists of a series of overlapping circles with radii r distributed as r−3, and having uniformly distributed gray level, which gives an accurate model of occlusion in a natural setting and hence mimics a natural scene. This target can be used to model the texture transfer through a camera system when a natural scene is captured. In the first part of our study we identify various factors that affect the MTF measured using the ‘Dead Leaves’ chart. These include variations in illumination, distance, exposure time and ISO sensitivity among others. We discuss the main differences of this method with the existing resolution measurement techniques and identify the advantages. In the second part of this study, we propose an improvement to the current texture MTF measurement algorithm. High frequency residual noise in the processed image contains the same frequency content as fine texture detail, and is sometimes reported as such, thereby leading to inaccurate results. A wavelet thresholding based denoising technique is utilized for modeling the noise present in the final captured image. This updated noise model is then used for calculating an accurate texture MTF. We present comparative results for both algorithms under various image capture conditions.