914 resultados para Mitral Valve


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rotary valve is a widely used mechanical device in many solids-handling industrial processes. However, it may also be responsible for most of the attrition effects occurring in a typical process. In this study, the attrition effects occurring in a rotary valve operating as a stand-alone device and as part of a pneumatic conveying system were investigated. In the former case granular attrition was carried out at three different rotary valve speeds and the experimental results obtained were found to be in good agreement with the Gwyn correlation. In the latter case three typical air flow rates were used in the pneumatic conveying system. The size distribution of the attrition product obtained at the lowest air flow rate used was not adequately described by the Gwyn correlation. The attrition process and mechanisms involved were analysed and the minimum size of the attrition product obtained from both modes of operations was found to be similar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dois casos de displasia da valva tricúspide são relatados neste trabalho. Os cães foram avaliados devido à fraqueza e presença de ascite. em ambos os casos, o exame ecocardiográfico mostrou insuficiência tricúspide e, em um deles, a inserção dos folhetos da valva tricúspide encontrava-se deslocada para baixo do ventrículo direito, caracterizando a anomalia de Ebstein. A terapia medicamentosa para insuficiência cardíaca congestiva foi iniciada, mas um dos animais veio a óbito subitamente alguns dias após o diagnóstico. O outro cão, apesar de inicialmente ter apresentado melhora significativa do quadro clínico, apresentou morte súbita. A necropsia dos animais revelou dilatação atrioventricular direita e folhetos tricúspides espessados. As características clínicas, métodos de diagnóstico e terapia medicamentosa são discutidas neste artigo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To report a case of cardiac arrhythmia related to a low dose of endovenous lanatoside C. Case report. A 23-year-old pregnant woman with mitral regurgitation complicated with preeclampsia and pulmonary edema presented 2 episodes of atrial tachycardia induced by a intravenous digitalis (2 mg, IV and 1 mg, IV, respectively). Conclusion. This case calls attention to the need for further studies analysing the security of digoxin use in preeclampsia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXTO: Válvula de uretra posterior (VUP) é uma conhecida malformação congênita urinária, geralmente diagnosticada em exames ultra-sonográficos pré-natais ou ao nascimento. Raramente, esta doença pode ser encontrada em adolescentes e em adultos. RELATO DE CASOS: Este artigo mostra dois casos de VUP, encontrados em um adolescente e em um adulto. Ambos apresentavam sinais clínicos de infecção do trato urinário e sintomas obstrutivos infravesicais. Os diagnósticos foram realizados por uretrocistografia miccional e uretrocistoscopia. Fulguração endoscópica das válvulas foi o tratamento de escolha para ambos os casos. O acompanhamento demonstrou melhora importante dos sintomas após o tratamento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper the performances of different cutting fluids and grinding wheel types were analysed in the grinding of SAE HVN-3 workpieces. The resulting residual stress, wheel wear and roughness were evaluated. The influence of the cutting fluid jet velocity v(j) was also analysed. As a conclusion, the lubrication ability seems to be the governing factor in the cutting fluid performance. The use of CBN wheels can significantly reduce the thermal damage in grinding, leading to compressive residual stresses. The CBN wheel and the cutting oil give an optimum combination for performing this grinding operation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work is to characterize a metallic slurry (Al-4.5%Cu) flow during thixoforming of an automotive valve. The necessary globular structure was obtained by first inoculating the alloy with TIBAL (5%Ti, 1%B, Al - rest) at 750.0°C, and then reheating to a state between liquidus and solidus prior to thixoforming. Two metallic slurries, with a solid phase of approximately 86.1 and 78.2 percent, were used to generate different experimental flow patterns during the thixoforming process. The flow of the material into the die was observed for total, and partial displacement (2.7, 5.4, 7.5mm) of the punch. The first displacement shows formation of the valve rod. The patterns at each step of displacement of the punch were preserved by quenching in water, thus revealing the profile of the die fill and microstructural evolution. Degeneration of the globular phase was observed along the piece thixoextruded. Thixoextrusion forces versus time curves were generated for partial and full displacement of the punch. Porosity was visible along the billet prior to thixoforming. However, some areas show that the porosity gradually decreased to zero as the thixoextrusion pressure increased. Turbulent, transient and laminar flow are analyzed in this work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a straightforward compromising method to determine the output power of all committed units during the scheduling time horizon. Unlike the conventional methods that work based on a constant pollution control cost (CPCC), this method works based on the system topology such as demand, minimum cost and minimum output emission of the system. In order to have a meaningful compromise between costs and emission in economic and emission dispatch (EED) problem, a flexible pollution control cost (FPCC) is proposed. Also a dynamic economic emission dispatch (DEED) approach is considered where the ramping constraints couple the scheduling hours; the inclusion of valve-point effect makes the DEED modeling more practical. The validity and effectiveness of the unproblematic FPCC approach is verified through an IEEE 30-bus test system with 6 unit for the 6-hour scheduling horizon. © 2013 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work is proposed the experimental study of hydrodynamic behaviour of membrane neurological valve, applied in treatment of hydrocephalus, a pathophisiology that affects both adults and children, caused due to the excess of cerebrospinal fluid in brain ventricles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Calcific aortic valve disease (CAVD) is a chronic disorder characterized by an abnormal mineralization of the leaflets, which is accelerated in bicuspid aortic valve (BAV). It is suspected that mechanical strain may promote/enhance mineralization of the aortic valve. However, the effect of mechanical strain and the involved pathways during mineralization of the aortic valve remains largely unknown. Valve interstitial cells (VICs) were isolated and studied under strain conditions. Human bicuspid aortic valves were examined as a model relevant to increase mechanical strain. Cyclic strain increased mineralization of VICs by several-fold. Scanning electron microscope (SEM) and energy dispersive X-ray (EDX) analyses revealed that mechanical strain promoted the formation of mineralized spheroid microparticles, which coalesced into larger structure at the surface of apoptotic VICs. Apoptosis and mineralization were closely associated with expression of ENPP1. Inhibition of ENPP1 greatly reduced mineralization of VIC cultures. Through several lines of evidence we showed that mechanical strain promoted the export of ENPP1-containing vesicles to the plasma membrane through a RhoA/ROCK pathway. Studies conducted in human BAV revealed the presence of spheroid mineralized structures along with the expression of ENPP1 in areas of high mechanical strain. Mechanical strain promotes the production and accumulation of spheroid mineralized microparticles by VICs, which may represent one important underlying mechanism involved in aortic valve mineralization. RhoA/ROCK-mediated export of ENPP1 to the plasma membrane promotes strain-induced mineralization of VICs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To ascertain incidence and predictors of new permanent pacemaker (PPM) following transcatheter aortic valve implantation (TAVI) with the self-expanding aortic bioprosthesis. Background: TAVI with the Medtronic Corevalve (MCV) Revalving System (Medtronic, Minneapolis, MN) has been associated with important post-procedural conduction abnormalities and frequent need for PPM. Methods: Overall, 73 consecutive patients with severe symptomatic AS underwent TAVI with the MCV at two institutions; 10 patients with previous pacemaker and 3 patients with previous aortic valve replacement were excluded for this analysis. Clinical, echocardiographic, and procedural data were collected prospectively in a dedicated database. A standard 12-lead ECG was recorded in all patients at baseline, after the procedure and predischarge. Decision to implant PPM was taken according to current guidelines. Logistic multivariable modeling was applied to identify independent predictors of PPM at discharge. Results: Patients exhibited high-risk features as evidenced by advanced age (mean = 82.1 +/- 6.2 years) and high surgical scores (logistic EuroSCORE 23.0 +/- 12.8%, STS score 9.4 +/- 6.9%). The incidence of new PPM was 28.3%. Interventricular septum thickness and logistic Euroscore were the baseline independent predictors of PPM. When procedural variables were included, the independent predictors of PPM were interventricular septum thickness (OR 0.52; 95% CI 0.320.85) and the distance between noncoronary cusp and the distal edge of the prosthesis (OR 1.37; 95% CI 1.031.83). Conclusions: Conduction abnormalities are frequently observed after TAVI with self-expandable bioprosthesis and definitive pacing is required in about a third of the patients, with a clear association with depth of implant and small interventricular septum thickness. (c) 2011 Wiley Periodicals, Inc.