952 resultados para Mesoscopic samples


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Toxoplasmosis may be life-threatening in fetuses and in immune-deficient patients. Conventional laboratory diagnosis of toxoplasmosis is based on the presence of IgM and IgG anti-Toxoplasma gondii antibodies; however, molecular techniques have emerged as alternative tools due to their increased sensitivity. The aim of this study was to compare the performance of 4 PCR-based methods for the laboratory diagnosis of toxoplasmosis. One hundred pregnant women who seroconverted during pregnancy were included in the study. The definition of cases was based on a 12-month follow-up of the infants. Methods Amniotic fluid samples were submitted to DNA extraction and amplification by the following 4 Toxoplasma techniques performed with parasite B1 gene primers: conventional PCR, nested-PCR, multiplex-nested-PCR, and real-time PCR. Seven parameters were analyzed, sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), negative likelihood ratio (NLR) and efficiency (Ef). Results Fifty-nine of the 100 infants had toxoplasmosis; 42 (71.2%) had IgM antibodies at birth but were asymptomatic, and the remaining 17 cases had non-detectable IgM antibodies but high IgG antibody titers that were associated with retinochoroiditis in 8 (13.5%) cases, abnormal cranial ultrasound in 5 (8.5%) cases, and signs/symptoms suggestive of infection in 4 (6.8%) cases. The conventional PCR assay detected 50 cases (9 false-negatives), nested-PCR detected 58 cases (1 false-negative and 4 false-positives), multiplex-nested-PCR detected 57 cases (2 false-negatives), and real-time-PCR detected 58 cases (1 false-negative). Conclusions The real-time PCR assay was the best-performing technique based on the parameters of Se (98.3%), Sp (100%), PPV (100%), NPV (97.6%), PLR (∞), NLR (0.017), and Ef (99%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction The cryopreservation of rabies virus has been described in detail in the literature. To date, little information is available on the use of cryoprotective agents for cold preservation of this virus, and the available data focus only on short-term virus preservation. In this study, we investigated the medium-term cryopreservation of samples of rabies virus using different cryopreservation protocols. Methods The cryopreservation protocols for the rabies virus samples were performed at -20°C and were divided according to the variables of time and cryoprotectant type used. The laboratory tests (intracerebral inoculation of mice, viral titration and direct immunofluorescence) were performed at regular intervals (360 and 720 days) to assess the viability of the viral samples according to the different preservation techniques used. Results After 1 year of cryopreservation, the fluorescence intensity of intracellular corpuscles of the rabies virus and the median survival time of the mice differed between the positive controls and the treatments with the cryoprotectants. After 2 years, most of the samples subjected to the cryopreservation protocols (including the controls) did not produce fluorescence. However, the virus samples exposed to the cryoprotectant sucrose (68% solution) responded positively in the direct immunofluorescence assay and in the intracerebral inoculation of the mice. Conclusions Medium-term cryopreservation of the rabies virus inactivates the viral sample. However, the cryoprotectant agent sucrose (68%) produces a preservative effect in cryopreserved rabies virus samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Methicillin-resistant Staphylococcus aureus (MRSA) strains have been responsible for many nosocomial outbreaks. Within hospitals, colonized employees often act as reservoirs for the spread of this organism. This study collected clinical samples of 91 patients admitted to the intensive care unit (ICU), hemodialysis/nephrology service and surgical clinic, and biological samples from the nasal cavities of 120 professionals working in those environments, of a University Hospital in Recife, in the State of Pernambuco, Brazil. The main objective of this study was to determine the occurrence and dissemination of methicillin- and vancomycin-resistant Staphylococcus spp. Methods The isolates obtained were tested for susceptibility to oxacillin and vancomycin and detection of the mecA gene. In addition, the isolates were evaluated for the presence of clones by ribotyping-polymerase chain reaction (PCR). Results MRSA occurrence, as detected by the presence of the mecA gene, was more prevalent among nursing technicians; 48.1% (13/27) and 40.7% (11/27) of the isolates were from health professionals of the surgical clinic. In patients, the most frequent occurrence of mecA-positive isolates was among the samples from catheter tips (33.3%; 3/9), obtained mostly from the hemodialysis/nephrology service. Eight vancomycin-resistant strains were found among the MRSA isolates through vancomycin screening. Based on the amplification patterns, 17 ribotypes were identified, with some distributed between patients and professionals. Conclusions Despite the great diversity of clones, which makes it difficult to trace the source of the infection, knowledge of the molecular and phenotypic profiles of Staphylococcus samples can contribute towards guiding therapeutic approaches in the treatment and control of nosocomial infections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IntroductionInfections caused by methicillin-resistant Staphylococcus aureus (MRSA) have become common in hospitals and the community environment, and this wide resistance has limited patient treatment. Clindamycin (CL) represents an important alternative therapy for infections caused by S. aureus. Antimicrobial susceptibility testing using standard methods may not detect inducible CL resistance. This study was performed to detect the phenotypes of resistance to macrolides-lincosamides-streptogramin B (MLSB) antibiotics, including CL, in clinical samples of S. aureusfrom patients at a tertiary hospital in Santa Maria, State of Rio Grande do Sul, Brazil.MethodsOne hundred and forty clinical isolates were submitted to the disk diffusion induction test (D-test) with an erythromycin (ER) disk positioned at a distance of 20mm from a CL disk. The results were interpreted according to the recommendations of the Clinical and Laboratory Standards Institute (CLSI).ResultsIn this study, 29 (20.7%) of the 140 S. aureus samples were resistant to methicillin (MRSA), and 111 (79.3%) were susceptible to methicillin (MSSA). The constitutive resistance phenotype (cMLSB) was observed in 20 (14.3%) MRSA samples and in 5 (3.6%) MSSA samples, whereas the inducible resistance phenotype (iMLSB) was observed in 3 (2.1%) MRSA samples and in 8 (5.8%) MSSA samples.ConclusionsThe D-test is essential for detecting the iMLSBphenotype because the early identification of this phenotype allows clinicians to choose an appropriate treatment for patients. Furthermore, this test is simple, easy to perform and inexpensive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractINTRODUCTION:Candida parapsilosis is a common yeast species found in cases of onychomycosis and candidemia associated with infected intravascular devices. In this study, we differentiated Candida parapsilosis sensu stricto, Candida orthopsilosis , and Candida metapsilosis from a culture collection containing blood and subungual scraping samples. Furthermore, we assessed the in vitro antifungal susceptibility of these species to fluconazole, itraconazole, voriconazole, posaconazole, amphotericin B, and caspofungin.METHODS:Differentiation of C. parapsilosis complex species was performed by amplification of the secondary alcohol dehydrogenase (SADH) gene and digestion by the restriction enzyme Ban I. All isolates were evaluated for the determination of minimal inhibitory concentrations using Etest, a method for antifungal susceptibility testing.RESULTS:Among the 87 isolates, 78 (89.7%) were identified as C. parapsilosis sensu stricto , five (5.7%) were identified as C. orthopsilosis , and four (4.6%) were identified as C. metapsilosis . Analysis of antifungal susceptibility showed that C. parapsilosis sensu strictoisolates were less susceptible to amphotericin B and itraconazole. One C. parapsilosis sensu stricto isolate was resistant to amphotericin B and itraconazole. Moreover, 10.2% of C. parapsilosis sensu stricto isolates were resistant to caspofungin. Two C. parapsilosis sensu strictoisolates and one C. metapsilosis isolate were susceptible to fluconazole in a dose-dependent manner.CONCLUSIONS:We reported the first molecular identification of C. parapsilosiscomplex species in State of Goiás, Brazil. Additionally, we showed that although the three species exhibited differences in antifungal susceptibility profiles, the primary susceptibility of this species was to caspofungin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The objective was to describe the results of the injection of immotile spermatozoa with flexible tails when only immotile spermatozoa are present in the semen sample. METHODS: A retrospective study was conducted to analyze the procedure results for 10 couples who participated in our intracytoplasmic sperm injection program. The sperm tail was considered flexible when it moved up and down independently of the head movement, and it was considered inflexible when the movement occurred together (tail plus head). The fertilization and pregnancy rate were analyzed. RESULTS: The normal fertilization rate (presence of 2 pronuclei) was 30.3% (40/132), and the abnormal fertilization rate (presence of less than or more than 2 pronuclei) was 6.81% (9/132). A total of 52 embryos were obtained with 9 transfer procedures performed (pregnancy rate: 11.12%). CONCLUSIONS: The sperm tail flexibility test (STFT) is an easy and cost-effective way for selecting viable immotile spermatozoa and can be used as an alternative method for determining the viability of spermatozoa. This test seems to be a simple and risk-free method when compared to the swelling test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An ion chromatography procedure, employing an IonPac AC15 concentrator column was used to investigate on line preconcentration for the simultaneous determination of inorganic anions and organic acids in river water. Twelve organic acids and nine inorganic anions were separated without any interference from other compounds and carry-over problems between samples. The injection loop was replaced by a Dionex AC15 concentrator column. The proposed procedure employed an auto-sampler that injected 1.5 ml of sample into a KOH mobile phase, generated by an Eluent Generator, at 1.5 mL min-1, which carried the sample to the chromatographic columns (one guard column, model AG-15, and one analytical column, model AS15, with 250 x 4mm i.d.). The gradient elution concentrations consisted of a 10.0 mmol l-1 KOH solution from 0 to 6.5 min, gradually increased to 45.0 mmol l-1 KOH at 21 min., and immediatelly returned and maintained at the initial concentrations until 24 min. of total run. The compounds were eluted and transported to an electro-conductivity detection cell that was attached to an electrochemical detector. The advantage of using concentrator column was the capability of performing routine simultaneous determinations for ions from 0.01 to 1.0 mg l-1 organic acids (acetate, propionic acid, formic acid, butyric acid, glycolic acid, pyruvate, tartaric acid, phthalic acid, methanesulfonic acid, valeric acid, maleic acid, oxalic acid, chlorate and citric acid) and 0.01 to 5.0 mg l-1 inorganic anions (fluoride, chloride, nitrite, nitrate, bromide, sulfate and phosphate), without extensive sample pretreatment and with an analysis time of only 24 minutes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The chemical composition of propolis is affected by environmental factors and harvest season, making it difficult to standardize its extracts for medicinal usage. By detecting a typical chemical profile associated with propolis from a specific production region or season, certain types of propolis may be used to obtain a specific pharmacological activity. In this study, propolis from three agroecological regions (plain, plateau, and highlands) from southern Brazil, collected over the four seasons of 2010, were investigated through a novel NMR-based metabolomics data analysis workflow. Chemometrics and machine learning algorithms (PLS-DA and RF), including methods to estimate variable importance in classification, were used in this study. The machine learning and feature selection methods permitted construction of models for propolis sample classification with high accuracy (>75%, reaching 90% in the best case), better discriminating samples regarding their collection seasons comparatively to the harvest regions. PLS-DA and RF allowed the identification of biomarkers for sample discrimination, expanding the set of discriminating features and adding relevant information for the identification of the class-determining metabolites. The NMR-based metabolomics analytical platform, coupled to bioinformatic tools, allowed characterization and classification of Brazilian propolis samples regarding the metabolite signature of important compounds, i.e., chemical fingerprint, harvest seasons, and production regions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molecular monitoring of BCR/ABL transcripts by real time quantitative reverse transcription PCR (qRT-PCR) is an essential technique for clinical management of patients with BCR/ABL-positive CML and ALL. Though quantitative BCR/ABL assays are performed in hundreds of laboratories worldwide, results among these laboratories cannot be reliably compared due to heterogeneity in test methods, data analysis, reporting, and lack of quantitative standards. Recent efforts towards standardization have been limited in scope. Aliquots of RNA were sent to clinical test centers worldwide in order to evaluate methods and reporting for e1a2, b2a2, and b3a2 transcript levels using their own qRT-PCR assays. Total RNA was isolated from tissue culture cells that expressed each of the different BCR/ABL transcripts. Serial log dilutions were prepared, ranging from 100 to 10-5, in RNA isolated from HL60 cells. Laboratories performed 5 independent qRT-PCR reactions for each sample type at each dilution. In addition, 15 qRT-PCR reactions of the 10-3 b3a2 RNA dilution were run to assess reproducibility within and between laboratories. Participants were asked to run the samples following their standard protocols and to report cycle threshold (Ct), quantitative values for BCR/ABL and housekeeping genes, and ratios of BCR/ABL to housekeeping genes for each sample RNA. Thirty-seven (n=37) participants have submitted qRT-PCR results for analysis (36, 37, and 34 labs generated data for b2a2, b3a2, and e1a2, respectively). The limit of detection for this study was defined as the lowest dilution that a Ct value could be detected for all 5 replicates. For b2a2, 15, 16, 4, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. For b3a2, 20, 13, and 4 labs showed a limit of detection at the 10-5, 10-4, and 10-3 dilutions, respectively. For e1a2, 10, 21, 2, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. Log %BCR/ABL ratio values provided a method for comparing results between the different laboratories for each BCR/ABL dilution series. Linear regression analysis revealed concordance among the majority of participant data over the 10-1 to 10-4 dilutions. The overall slope values showed comparable results among the majority of b2a2 (mean=0.939; median=0.9627; range (0.399 - 1.1872)), b3a2 (mean=0.925; median=0.922; range (0.625 - 1.140)), and e1a2 (mean=0.897; median=0.909; range (0.5174 - 1.138)) laboratory results (Fig. 1-3)). Thirty-four (n=34) out of the 37 laboratories reported Ct values for all 15 replicates and only those with a complete data set were included in the inter-lab calculations. Eleven laboratories either did not report their copy number data or used other reporting units such as nanograms or cell numbers; therefore, only 26 laboratories were included in the overall analysis of copy numbers. The median copy number was 348.4, with a range from 15.6 to 547,000 copies (approximately a 4.5 log difference); the median intra-lab %CV was 19.2% with a range from 4.2% to 82.6%. While our international performance evaluation using serially diluted RNA samples has reinforced the fact that heterogeneity exists among clinical laboratories, it has also demonstrated that performance within a laboratory is overall very consistent. Accordingly, the availability of defined BCR/ABL RNAs may facilitate the validation of all phases of quantitative BCR/ABL analysis and may be extremely useful as a tool for monitoring assay performance. Ongoing analyses of these materials, along with the development of additional control materials, may solidify consensus around their application in routine laboratory testing and possible integration in worldwide efforts to standardize quantitative BCR/ABL testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential and applicability of UHPSFC-MS/MS for anti-doping screening in urine samples were tested for the first time. For this purpose, a group of 110 doping agents with diverse physicochemical properties was analyzed using two separation techniques, namely UHPLC-MS/MS and UHPSFC-MS/MS in both ESI+ and ESI- modes. The two approaches were compared in terms of selectivity, sensitivity, linearity and matrix effects. As expected, very diverse retentions and selectivities were obtained in UHPLC and UHPSFC, proving a good complementarity of these analytical strategies. In both conditions, acceptable peak shapes and MS detection capabilities were obtained within 7min analysis time, enabling the application of these two methods for screening purposes. Method sensitivity was found comparable for 46% of tested compounds, while higher sensitivity was observed for 21% of tested compounds in UHPLC-MS/MS and for 32% in UHPSFC-MS/MS. The latter demonstrated a lower susceptibility to matrix effects, which were mostly observed as signal suppression. In the case of UHPLC-MS/MS, more serious matrix effects were observed, leading typically to signal enhancement and the matrix effect was also concentration dependent, i.e., more significant matrix effects occurred at the lowest concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel approach to measure carbon dioxide (CO2) in gaseous samples, based on a precise and accurate quantification by (13)CO2 internal standard generated in situ is presented. The main goal of this study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable in the routine determination of CO2. The main drawback of the GC methods discussed in the literature for CO2 measurement is the lack of a specific internal standard necessary to perform quantification. CO2 measurement is still quantified by external calibration without taking into account analytical problems which can often occur considering gaseous samples. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in situ an internal labeled standard gas ((13)CO2) on the basis of the stoichiometric formation of CO2 by the reaction of hydrochloric acid (HCl) with sodium hydrogen carbonate (NaH(13)CO3). This method allows a precise measurement of CO2 concentration and was validated on various human postmortem gas samples in order to study its efficiency.