855 resultados para Measurement in Bacteriology
Resumo:
A new method based on analysis of a single diffraction pattern is proposed to measure deflections in micro-cantilever (MC) based sensor probes, achieving typical deflection resolutions of 1nm and surface stress changes of 50 mu N/m. The proposed method employs a double MC structure where the deflection of one of the micro-cantilevers relative to the other due to surface stress changes results in a linear shift of intensity maxima of the Fraunhofer diffraction pattern of the transilluminated MC. Measurement of such shifts in the intensity maxima of a particular order along the length of the structure can be done to an accuracy of 0.01mm leading to the proposed sensitivity of deflection measurement in a typical microcantilever. This method can overcome the fundamental measurement sensitivity limit set by diffraction and pointing stability of laser beam in the widely used Optical Beam Deflection method (OBDM).
Resumo:
We consider the issue of the top quark Yukawa coupling measurement in a model-independent and general case with the inclusion of CP violation in the coupling. Arguably the best process to study this coupling is the associated production of the Higgs boson along with a t (t) over bar pair in a machine like the International Linear Collider (ILC). While detailed analyses of the sensitivity of the measurement-assuming a Standard Model (SM)-like coupling is available in the context of the ILC-conclude that the coupling could be pinned down to about a 10% level with modest luminosity, our investigations show that the scenario could be different in the case of a more general coupling. The modified Lorentz structure resulting in a changed functional dependence of the cross section on the coupling, along with the difference in the cross section itself leads to considerable deviation in the sensitivity. Our studies of the ILC with center-of-mass energies of 500 GeV, 800 GeV, and 1000 GeV show that moderate CP mixing in the Higgs sector could change the sensitivity to about 20%, while it could be worsened to 75% in cases which could accommodate more dramatic changes in the coupling. Detailed considerations of the decay distributions point to a need for a relook at the analysis strategy followed for the case of the SM, such as for a model-independent analysis of the top quark Yukawa coupling measurement. This study strongly suggests that a joint analysis of the CP properties and the Yukawa coupling measurement would be the way forward at the ILC and that caution must be exercised in the measurement of the Yukawa couplings and the conclusions drawn from it.
Resumo:
Quantum point contact (QPC), one of the typical mesoscopic transport devices, has been suggested to be an efficient detector for quantum measurement. In the context of two-state charge qubit, our previous studies showed that the QPC's measurement back-action cannot be described by the conventional Lindblad quantum master equation. In this work, we study the measurement problem of a multistate system, say, an electron in disordered potential, subject to the quantum measurement of the mesoscopic detector QPC. The effect of measurement back-action and the detector's readout current are analyzed, where particular attention is focused on some new features and the underlying physics associated with the measurement-induced delocalization versus the measurement voltages.
Resumo:
PURPOSE: To study the accuracy and acceptability of intraocular pressure (IOP) measurement by the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer in children. METHODS: Fifty children (5 to 14 years old) participated in this prospective comparative study. IOP was measured with the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer by three different examiners who were masked to the results. The children were also asked to grade the degree of discomfort from 0 to 5 (0 = no discomfort; 5 = most discomfort). RESULTS: The mean IOPs measured by the Goldmann tonometer, pressure phosphene tonometer, and non-contact tonometer were 15.9 mm Hg (standard deviation [SD]: = 5.5 mm Hg; range: 10 to 36 mm Hg), 16.0 mm Hg (SD: 2.9 mm Hg; range: 12 to 25 mm Hg), and 15.7 mm Hg (SD = 5.1 mm Hg; range: 8 to 32 mm Hg), respectively (P = .722). The mean difference between pressure phosphene tonometer and Goldmann tonometer readings was 2.9 mm Hg and that between non-contact tonometer and Goldmann tonometer readings was 2.1 mm Hg. The 95% confidence interval of the mean difference between pressure phosphene tonometer and Goldmann tonometer readings was -1.07 and 1.19, and that between non-contact tonometer and Goldmann tonometer readings was -1.07 and 0.53. The mean discomfort ratings for the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer were 0.6, 2.0, and 2.3, respectively (P < .001). CONCLUSION: Although the pressure phosphene tonometer was less accurate than the non-contact tonometer compared with Goldmann tonometer, it gave a reasonably close estimate and had a high specificity of raised IOP. In addition, measurement by the pressure phosphene tonometer is most acceptable to children. The pressure phosphene tonometer can be considered as an alternative method of IOP measurement in children.
Resumo:
A measurement of the top quark mass using events with one charged lepton, missing transverse energy, and jets in the final state, collected by the D0 detector from p (p) over bar collisions at root s=1.96 TeV at the Fermilab Tevatron collider, is presented. A constrained fit is used to fully reconstruct the kinematics of the events. For every event a top quark mass likelihood is calculated taking into account all possible jet assignments and the probability that an event is signal or background. Lifetime-based identification of b jets is employed to enhance the separation between t (t) over bar signal and background from other physics processes and to improve the assignment of the observed jets to the quarks in the t (1) over bar hypothesis. We extract a multiplicative jet energy scale (JES) factor in situ, greatly reducing the systematic effect related to the jet energy measurement. In a data sample with an integrated luminosity of 425 pb(-1), we observe 230 candidate events, with an estimated background of 123 events, and measure m(t)=173.7 +/- 4.4(stat+JES)(-2.0)(+2.1)(syst) GeV. This result represents the first application of the ideogram technique to the measurement of the top quark mass in lepton+jets events.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The t (t) over bar production cross section and top quark mass are measured in proton-proton collisions at root s = 7 TeV in a data sample corresponding to an integrated luminosity of 36 pb(-1) collected by the CMS experiment. The measurements are performed in events with two leptons (electrons or muons) in the final state. Results of the cross section measurement in events with and without b-quark identification are obtained and combined. The measured value is sigma(tt) - 168 +/- 18 (stat:) +/- 14 (syst:) +/- 7 (lumi:) pb, consistent with predictions from the standard model. The top quark mass m(top) is reconstructed with two different methods, a full kinematic analysis and a matrix weighting technique. The combination yields a measurement of m(top) = 175.5 +/- 4.6 (stat:) +/- 4: 6 (syst:) GeV/c(2).
Resumo:
Introduction .-- I. Inclusion of international guidelines in disability measurement processes in Latin American and Caribbean countries .-- II. State of the art in disability measurement in the region’s countries .-- III. Main difficulties facing countries in terms of collecting information .-- Conclusions.
Resumo:
1. The member and associate member countries of the Economic Commission for Latin America and the Caribbean/Caribbean Development and Cooperation Committee (ECLAC/CDCC) have committed to pursuing and achieving the Millennium Development Goals, a common set of goals and targets to bring all people up to minimum acceptable standards of human development by 2015. 2. However, in spite of various capacity-building initiatives, Caribbean countries continued to experience difficulties in addressing additional demands of monitoring and measuring progress created by the Millennium Development Goals and other Internationally Agreed Development Goals. Therefore, it was necessary to implement activities to ensure the further building/strengthening of institutional capabilities for generating reliable social, economic and environmental statistics among Caribbean States. 3. The ECLAC project entitled “Strengthening the Capacity of National Statistical Offices in the Caribbean Small Island Developing States to fulfil the Millennium Development Goals and other Internationally Agreed Development Goals” sought to build and strengthen institutional capabilities for generating and compiling reliable social, economic and environmental statistics in the Caribbean subregion, through the provision of technical support, as well as the conduct of training workshops for statisticians and policymakers. 4. Within the objectives of that project, ECLAC Subregional Headquarters for the Caribbean convened a regional training workshop on the measurement of poverty in the Caribbean in Port of Spain, to build the capacity of government officials and other relevant stakeholders. 5. The overall objective of the workshop was to develop and strengthen the national technical capacity of public officials in data processing, systematization and dissemination of poverty indicators and measurement in the Caribbean subregion. The workshop further sought to review and discuss the current approaches to poverty measurement and monitoring in an effort to identify methods to ensure that monitoring and reporting of the Millennium Development Goals were conducted according to internationally agreed upon methodologies. Furthermore, the workshop also intended to review different methods of poverty measurements, including the multidimensional methodology for the measurement of poverty. 6. Participants were introduced to different methods of poverty measurements and other aggregation proposals which would enable countries to better measure progress towards Goal 1 on poverty, report on it and apply evidence-based approaches to national policymaking and planning.
Resumo:
The scope of this study was to estimate calibrated values for dietary data obtained by the Food Frequency Questionnaire for Adolescents (FFQA) and illustrate the effect of this approach on food consumption data. The adolescents were assessed on two occasions, with an average interval of twelve months. In 2004, 393 adolescents participated, and 289 were then reassessed in 2005. Dietary data obtained by the FFQA were calibrated using the regression coefficients estimated from the average of two 24-hour recalls (24HR) of the subsample. The calibrated values were similar to the the 24HR reference measurement in the subsample. In 2004 and 2005 a significant difference was observed between the average consumption levels of the FFQA before and after calibration for all nutrients. With the use of calibrated data the proportion of schoolchildren who had fiber intake below the recommended level increased. Therefore, it is seen that calibrated data can be used to obtain adjusted associations due to reclassification of subjects within the predetermined categories.
Resumo:
DCE-MRI is an important technique in the study of small animal cancer models because its sensitivity to vascular changes opens the possibility of quantitative assessment of early therapeutic response. However, extraction of physiologically descriptive parameters from DCE-MRI data relies upon measurement of the vascular input function (VIF), which represents the contrast agent concentration time course in the blood plasma. This is difficult in small animal models due to artifacts associated with partial volume, inflow enhancement, and the limited temporal resolution achievable with MR imaging. In this work, the development of a suite of techniques for high temporal resolution, artifact resistant measurement of the VIF in mice is described. One obstacle in VIF measurement is inflow enhancement, which decreases the sensitivity of the MR signal to the presence of contrast agent. Because the traditional techniques used to suppress inflow enhancement degrade the achievable spatiotemporal resolution of the pulse sequence, improvements can be achieved by reducing the time required for the suppression. Thus, a novel RF pulse which provides spatial presaturation contemporaneously with the RF excitation was implemented and evaluated. This maximizes the achievable temporal resolution by removing the additional RF and gradient pulses typically required for suppression of inflow enhancement. A second challenge is achieving the temporal resolution required for accurate characterization of the VIF, which exceeds what can be achieved with conventional imaging techniques while maintaining adequate spatial resolution and tumor coverage. Thus, an anatomically constrained reconstruction strategy was developed that allows for sampling of the VIF at extremely high acceleration factors, permitting capture of the initial pass of the contrast agent in mice. Simulation, phantom, and in vivo validation of all components were performed. Finally, the two components were used to perform VIF measurement in the murine heart. An in vivo study of the VIF reproducibility was performed, and an improvement in the measured injection-to-injection variation was observed. This will lead to improvements in the reliability of quantitative DCE-MRI measurements and increase their sensitivity.
Resumo:
Radiocarbon offers a unique possibility for unambiguous source apportionment of carbonaceous particles due to a direct distinction of non-fossil and fossil carbon. In this work, particulate matter of different size fractions was collected at 4 sites in Switzerland to examine whether fine and coarse carbonaceous particles exhibit different fossil and contemporary sources. Elemental carbon (EC) and organic carbon (OC) as well as water-soluble OC (WSOC) and water-insoluble OC (WINSOC) were separated and determined for subsequent 14C measurement. In general, both fossil and non-fossil fractions in OC and EC were found more abundant in the fine than in the coarse mode. However, a substantial fraction (~20 ± 5%) of fossil EC was found in coarse particles, which could be attributed to traffic-induced non-exhaust emissions. The contribution of biomass burning to coarse-mode EC in winter was relatively high, which is likely associated to the coating of EC with organic and/or inorganic substances emitted from intensive wood burning. Further, fossil OC (i.e. from vehicle emissions) was found to be smaller than non-fossil OC due to the presence of primary biogenic OC and/or growing in size of wood-burning OC particles during aging processes. 14C content in WSOC indicated that the second organic carbon rather stems from non-fossil precursors for all samples. Interestingly, both fossil and non-fossil WINSOC concentrations were found to be higher in fine particles than in coarse particles in winter, which is likely due to primary wood burning emissions and/or secondary formation of WINSOC.
Resumo:
INTRODUCTION Monitoring breathing pattern is especially relevant in infants with lung disease. Recently, a vest-based inductive plethysmograph system (FloRight®) has been developed for tidal breathing measurement in infants. We investigated the accuracy of tidal breathing flow volume loop (TBFVL) measurements in healthy term-born infants and infants with lung disease by the vest-based system in comparison to an ultrasonic flowmeter (USFM) with a face mask. We also investigated whether the system discriminates between healthy infants and those with lung disease. METHODS Floright® measures changes in thoracoabdominal volume during tidal breathing through magnetic field changes generated by current-carrying conductor coils in an elastic vest. Simultaneous TBFVL measurements by the vest-based system and the USFM were performed at 44 weeks corrected postmenstrual age during quiet unsedated sleep. TBFVL parameters derived by both techniques and within both groups were compared. RESULTS We included 19 healthy infants and 18 infants with lung disease. Tidal volume per body weight derived by the vest-based system was significantly lower with a mean difference (95% CI) of -1.33 ml/kg (-1.73; -0.92), P < 0.001. Respiratory rate and ratio of time to peak tidal expiratory flow over total expiratory time (tPTEF/tE) did not differ between the two techniques. Both systems were able to discriminate between healthy infants and those with lung disease using tPTEF/tE. CONCLUSION FloRight® accurately measures time indices and may discriminate between healthy infants and those with lung disease, but demonstrates differences in tidal volume measurements. It may be better suited to monitor breathing pattern than for TBFVL measurements.
Resumo:
OBJECTIVE: This paper describes the Australian experience to date with a national 'roll out' of routine outcome measurement in public sector mental health services. METHODS: Consultations were held with 123 stakeholders representing a range of roles. RESULTS: Australia has made an impressive start to nationally implementing routine outcome measurement in mental health services, although it still has a long way to go. All States/Territories have established data collection systems, although some are more streamlined than others. Significant numbers of clinicians and managers have been trained in the use of routine outcome measures, and thought is now being given to ongoing training strategies. Outcome measurement is now occurring 'on the ground'; all States/Territories will be reporting data for 2003-04, and a number have been doing so for several years. Having said this, there is considerable variability regarding data coverage, completeness and compliance. Some States/Territories have gone to considerable lengths to 'embed' outcome measurement in day-to-day practice. To date, reporting of outcome data has largely been limited to reports profiling individual consumers and/or aggregate reports that focus on compliance and data quality issues, although a few States/Territories have begun to turn their attention to producing aggregate reports of consumers by clinician, team or service. CONCLUSION: Routine outcome measurement is possible if it is supported by a co-ordinated, strategic approach and strong leadership, and there is commitment from clinicians and managers. The Australian experience can provide lessons for other countries.