944 resultados para MICROFLUIDIC CHIPS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the development of a microfluidic methodology, using RNA extraction and reverse transcription PCR, for investigating expression levels of cytochrome P450 genes. Cytochrome P450 enzymes are involved in the metabolism of xenobiotics, including many commonly prescribed drugs, therefore information on their expression is useful in both pharmaceutical and clinical settings. RNA extraction, from rat liver tissue or primary rat hepatocytes, was performed using a silica-based solid-phase extraction technique. Following elution of the purified RNA, amplification of target sequences for the housekeeping gene, glyceraldehyde-3-phosphate dehydrogenase (GAPDH) and the cytochrome P450 gene CYP1A2, was carried out using a one-step reverse transcription PCR. Once the microfluidic methodology had been optimized, analysis of control and 3-methylcholanthrene-induced primary rat hepatocytes were used to evaluate the system. As expected, GAPDH was consistently expressed, whereas CYP1A2 levels were found to be raised in the drug-treated samples. The proposed system offers an initial platform for development of both rapid throughput analyzers for pharmaceutical drug screening and point-of-care diagnostic tests to aid provision of drug regimens, which can be tailor-made to the individual patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whilst a multitude of techniques have been employed to study the biology of tumour tissue and its response to chemotherapeutic reagents, most current methodologies do not capture the sophistication of the in vivo environment. Microfluidics however offers the ability to maintain and interrogate primary tissue samples in an environment with biomimetic flow characteristics. In this study head and neck squamous cell carcinoma (HNSCC) tumour biopsies have been used to investigate the performance of a microfluidic device for generating clinically-useful information. The response of fresh and cryogenically-frozen primary HNSCC or metastatic lymph node samples to chemotherapy drugs (cisplatin, 5-flurouracil or docetaxel), alone and in combination, were monitored for both proliferation (water-soluble tetrazolium salt metabolism) and cell death biomarker release (lactate dehydrogenase, LDH) “off-chip”. The frozen tissue showed no significant difference in terms of either proliferation or LDH release in comparison with the matched fresh samples. Administration of all drugs caused cell death, in a dose-response manner, with the combination showing the greatest amount of cytotoxicity particularly at days 8 and 9; correlating well with published clinical data. The system described here offers an innovative method for studying the tumour microenvironment in vitro and, through incorporation of relevant analytical modules, provides the basis of a pre-clinical device that can be used to define personalised treatment regimens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tumors are heterogeneous masses of cells characterized pathologically by their size and spread. Their chaotic biology makes treatment of malignancies hard to generalize. We present a robust and reproducible glass microfluidic system, for the maintenance and “interrogation” of head and neck squamous cell carcinoma (HNSCC) tumor biopsies, which enables continuous media perfusion and waste removal, recreating in vivo laminar flow and diffusion-driven conditions. Primary HNSCC or metastatic lymph samples were subsequently treated with 5-fluorouracil and cisplatin, alone and in combination, and were monitored for viability and apoptotic biomarker release ‘off-chip’ over 7 days. The concentration of lactate dehydrogenase was initially high but rapidly dropped to minimally detectable levels in all tumor samples; conversely, effluent concentration of WST-1 (cell proliferation) increased over 7 days: both factors demonstrating cell viability. Addition of cell lysis reagent resulted in increased cell death and reduction in cell proliferation. An apoptotic biomarker, cytochrome c, was analyzed and all the treated samples showed higher levels than the control, with the combination therapy showing the greatest effect. Hematoxylin- and Eosin-stained sections from the biopsy, before and after maintenance, demonstrated the preservation of tissue architecture. This device offers a novel method of studying the tumor environment, and offers a pre-clinical model for creating personalized treatment regimens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An integrated system employing anion exchange for the extraction of DNA from biological samples prior to polymerase chain reaction DNA amplification has been developed, based on microfluidic methodology utilising electrokinetic pumping. In this system, the biological samples were added directly to chitosan-coated silica beads to facilitate DNA immobilisation. The purified, pre-concentrated DNA was then eluted using a combination of electro-osmotic flow enhanced with electrophoretic mobility, which enable DNA to be transported by both mechanisms into the DNA amplification chamber. Through optimisation of the DNA elution conditions, average DNA extraction efficiencies of 69.1% were achievable. Subsequent DNA amplification performed on the microfluidic system demonstrated not only the ability to use electrokinetic movement to integrate the two processes on a single device, but also that the quality and quantity of DNA eluted was suitable for downstream analysis. This work offers an attractive real-world to chip interface and a route to simpler Lab-on-a-Chip technology which eliminates the need for moving parts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Urine is a preferred specimen for nucleic acid-based detection of sexually transmitted infections (STIs) but represents a challenge for microfluidic devices due to low analyte concentrations. We present an extraction methodology enabling rapid on-chip nucleic acid purification directly from clinically relevant sample volumes up to 1 ml and subsequent PCR amplification detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

 Cardiovascular diseases are the most prevalent medical conditions affecting the modern world, reducing the quality of life for those affected and causing an ever increasing burden on clinical resources. Cardiac biomarkers are crucial in the diagnosis and management of patient outcomes. In that respect, such proteins are desirable to be measured at the point of care, overcoming the shortcomings of current instrumentation. We present a CO2 laser engraving technique for the rapid prototyping of a polymeric autonomous capillary system with embedded on-chip planar lenses and biosensing elements, the first step towards a fully miniaturised and integrated cardiac biosensing platform. The system has been applied to the detection of cardiac Troponin I, the gold standard biomarker for the diagnosis of acute myocardial infarction. The devised lab-on-a-chip device was demonstrated to have 24 pg/ml limit of detection, which is well within the minimum threshold for clinically applicable concentrations. Assays were completed within approximately 7–9 min. Initial results suggest that, given the portability, low power consumption and high sensitivity of the device, this technology could be developed further into point of care instrumentation useful in the diagnosis of various forms of cardiovascular diseases. 2014 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Valves are one of the key components in microfluidic devices to control the fluid flow. In this paper we introduce a novel manual pin-valve which can operate in both analogue (partially close) and digital (on/off) states. We also demonstrate implementation of this pin-valve in a hydrodynamic flow focusing (HFF) device. © The Royal Society of Chemistry 2014.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A microchip pressure-driven liquid chromatographic system with a packed column has been designed and fabricated by using poly(dimethylsiloxane) (PDMS). The liquid chromatographic column was packed with mesoporous silica beads of Ia3d space group. Separation of dyes and biopolymers was carried out to verify the performance of the chip. A mixture of dyes (fluorescein and rhodamine B) and a biopolymer mixture (10 kDa Dextran and 66 kDa BSA) were separated and the fluorescence technique was employed to detect the movement of the molecules. Fluorescein molecule was a nonretained species and rhodamine B was attached onto silica surface when dye mixture in deionized water was injected into the microchannel. The retention times for dextran molecule and BSA molecule in biopolymer separation experiment were 45 s and 120 s, respectively. Retention factor was estimated to be 3.3 for dextran and 10.4 for BSA. The selectivity was 3.2 and resolution was 10.7. Good separation of dyes and biopolymers was achieved and the chip design was verified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biomarkers have been described as characteristics, most often molecular, that provide information about biological states, whether normal, pathological, or therapeutically modified. They hold great potential to assist diagnosis and prognosis, monitor disease, and assess therapeutic effectiveness. While a few biomarkers are routinely utilised clinically, these only reflect a very small percentage of all biomarkers discovered. Numerous factors contribute to the slow uptake of these new biomarkers, with challenges faced throughout the biomarker development pipeline. Microfluidics offers two important opportunities to the field of biomarkers: firstly, it can address some of these developmental obstacles, and secondly, it can provide the precise and complex platform required to bridge the gap between biomarker research and the biomarker-based analytical device market. Indeed, adoption of microfluidics has provided a new avenue for advancement, promoting clinical utilisation of both biomarkers and their analytical platforms. This review will discuss biomarkers and outline microfluidic platforms developed for biomarker analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intercellular signalling has been identified as a highly complex process, responsible for orchestrating many physiological functions. While conventional methods of investigation have been useful, their limitations are impeding further development. Microfluidics offers an opportunity to overcome some of these limitations. Most notably, microfluidic systems can emulate the in-vivo environments. Further, they enable exceptionally precise control of the microenvironment, allowing complex mechanisms to be selectively isolated and studied in detail. There has thus been a growing adoption of microfluidic platforms for investigation of cell signalling mechanisms. This review provides an overview of the different signalling mechanisms and discusses the methods used to study them, with a focus on the microfluidic devices developed for this purpose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A microfabricated poly(dimethylsiloxane) (PDMS) chip containing channel filled with polymer monolith has been developed for on-chip biomolecule separation. Methacrylate monolithic polymers were prepared by photo-initiated polymerization within the channel to serve as a continuous stationary phase. The monolithic polymer was functionalized with a weak anion-exchange ligand, and key parameters affecting the binding characteristics of the system were investigated. The total binding capacity was unaffected by the flow rate of the mobile phase but varied significantly with changes in ionic strength and pH of the binding buffer. The binding capacity decreased with increasing buffer ionic strength, and this is due to the limited available binding sites for protein adsorption resulting from cationic shielding effect. Similarly, the binding capacity decreased with decreasing buffer pH towards the isoelectric point of the protein. A protein mixture, BSA and ovalbumin, was used to illustrate the capacity of the methacrylate-based microfluidic chip for rapid biomolecule separation.