932 resultados para MEASURE


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A technique to measure wall flow variation in Diesel Particle Filters (DPFs) is described. In a recent paper, it was shown how the flow distribution in DPFs could be measured in a non-destructive manner. This involved measuring the progressive dilution of a tracer gas introduced at the "outlet" channel upstream end. In the present paper, a significant further improvement to this technique is described, in which only a single probe is required, rather than the two of the previous technique. The single, traversable, probe consists of a controllable flow sink, and slightly downstream, a tracer gas supply. By controlling the sink flow rate such that a very small concentration of tracer gas is aspirated into it, the total flow up to that location in the channel is determined. Typical results showing the axial variation in the wall flow for known wall blockage cases are presented. It is suggested that this technique could be used to interpret the soot loading in the filter channels in a non-intrusive way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An attitude scale was constructed to measure the attitude of fisherwomen towards improved fish processing methods. To construct the attitude scale, 'scale' and ‘Q’ values (the interquartile ranges) were calculated for 31 statements selected, based on the opinion of 34 judges. Based on the 'scale' and ‘Q’ values 16 statements were selected with eight favorable statements and eight unfavorable statements. The weightages given were 3, 2 and 1 for favorable statements and 1, 2 and 3 for unfavorable statements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Humans appear to be sensitive to relative small changes in their surroundings. These changes are often initially perceived as irrelevant, but they can cause significant changes in behavior. However, how exactly people's behavior changes is often hard to quantify. A reliable and valid tool is needed in order to address such a question, ideally measuring an important point of interaction, such as the hand. Wearable-body-sensor systems can be used to obtain valuable, behavioral information. These systems are particularly useful for assessing functional interactions that occur between the endpoints of the upper limbs and our surroundings. A new method is explored that consists of computing hand position using a wearable sensor system and validating it against a gold standard reference measurement (optical tracking device). Initial outcomes related well to the gold standard measurements (r = 0.81) showing an acceptable average root mean square error of 0.09 meters. Subsequently, the use of this approach was further investigated by measuring differences in motor behavior, in response to a changing environment. Three subjects were asked to perform a water pouring task with three slightly different containers. Wavelet analysis was introduced to assess how motor consistency was affected by these small environmental changes. Results showed that the behavioral motor adjustments to a variable environment could be assessed by applying wavelet coherence techniques. Applying these procedures in everyday life, combined with correct research methodologies, can assist in quantifying how environmental changes can cause alterations in our motor behavior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new scheme for the code of chemical environments of compounds is described in this paper, and three molecular similarity methods have been used to select nearest neighbors from four different types of probe compounds. One of the methods is based on the C-13 NMR spectra. The second method is based on the code of chemical environments and molecular topological index A(x). The third approach, i.e. the Tanimoto coefficient, is also based on the code of chemical environments, but not to use the topological index. Five nearest neighbors for each probe compound using these three molecular similarity methods were determined and taken from the database of 7309 structures. The results indicate that the scheme of the chemical environment code and the method for similarity measure of intermolecules suggested in this study are reasonable. (C) 1998 Published by Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The redlip mullet, Liza haematocheila, is a common species in polyculture as a scavenger in China. Feeding on detritus, redlip mullet transports nutrients from sediments up into the water column and converts them into forms that can be utilized by phytoplankton and affects the relative abundance of detritus and dissolved inorganic nutrients to phytoplankton, zooplankton and other fishes. We used nitrogen and carbon as the indicators in this study to measure the scavenging ability, which means intake of nitrogen or carbon by redlip mullet, and the loss of nutrients. Temperature and body weight significantly affected growth nitrogen, faecal nitrogen and faecal carbon. At a certain temperature, the proportion of growth nitrogen or growth carbon increased while the proportion of excretion nitrogen or respiration carbon decreased with increasing body weight.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O pôrometro de pós-colheita é um instrumento para medir transpiração, resistência difusiva e déficit de pressão de vapor por manometria a volume constante e por volumetria a pressão constante. É constituído de uma câmara de transpiração com fechamento hermético contendo um suporte de amostras sobre um ventilador e externamente um manômetro de coluna de água com pipeta graduada móvel. Sob temperatura constante, o déficit de pressão de vapor (.P), e o volume de vapor de água (.V) foram proporcionais aos volumes de água vaporizados. Com o uso de um excesso de água este aumento da pressão de vapor iguala-se, em módulo, ao déficit de pressão de vapor do ar na câmara de transpiração. Para amostras do ar atmosférico no laboratório, o déficit de pressão de vapor foi calculado a partir das temperaturas de bulbo seco e úmido em um psicrômetro ventilado e por manometria. A correlação entre estes dois métodos foi de 0,976. A acurácia das medidas de transpiração é tal que o produto do volume morto da câmara (V) pela declividade (.P/ .V) determinada pelo vapor de água liberado no processo iguala-se à pressão barométrica, com erro inferior a 1%. Um exemplo experimental do uso do porômetro de pós-colheita em cenoura é apresentado juntamente e os detalhes para obter a resistência difusiva e espessura da camada laminar. O porômetro de pós-colheita é um porômetro de difusão simples, robusto, que poderá ser usado em estudos de efeito de cêras, na seleção de cultivares e em variados outros estudos de fisiologia de pós-colheita.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Breast region measurements are important for research, but they may also become significant in the legal field as a quantitative tool for preoperative and postoperative evaluation. Direct anthropometric measurements can be taken in clinical practice. the aim of this study was to compare direct breast anthropometric measurements taken with a tape measure and a compass.Forty women, aged 18-60 years, were evaluated. They had 14 anatomical landmarks marked on the breast region and arms. the union of these points formed eight linear segments and one angle for each side of the body. the volunteers were evaluated by direct anthropometry in a standardized way, using a tape measure and a compass.Differences were found between the tape measure and the compass measurements for all segments analyzed (p > 0.05).Measurements obtained by tape measure and compass are not identical. Therefore, once the measurement tool is chosen, it should be used for the pre- and postoperative measurements in a standardized way.This journal requires that authors assign a level of evidence to each article. for a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.