984 resultados para Lung volume measurement
Prediction of survival in ischemic cardiomyopathy: measurement of ventricular volume or dysynchrony?
Resumo:
This paper determines the capability of two photogrammetric systems in terms of their measurement uncertainty in an industrial context. The first system – V-STARS inca3 from Geodetic Systems Inc. – is a commercially available measurement solution. The second system comprises an off-the-shelf Nikon D700 digital camera fitted with a 28 mm Nikkor lens and the research-based Vision Measurement Software (VMS). The uncertainty estimate of these two systems is determined with reference to a calibrated constellation of points determined by a Leica AT401 laser tracker. The calibrated points have an average associated standard uncertainty of 12·4 μm, spanning a maximum distance of approximately 14·5 m. Subsequently, the two systems’ uncertainty was determined. V-STARS inca3 had an estimated standard uncertainty of 43·1 μm, thus outperforming its manufacturer's specification; the D700/VMS combination achieved a standard uncertainty of 187 μm.
Resumo:
BACKGROUND AND PURPOSE: To assess the impact of a standardized delineation protocol and training interventions on PET/CT-based target volume delineation (TVD) in NSCLC in a multicenter setting.
MATERIAL AND METHODS: Over a one-year period, 11 pairs, comprised each of a radiation oncologist and nuclear medicine physician with limited experience in PET/CT-based TVD for NSCLC from nine different countries took part in a training program through an International Atomic Energy Agency (IAEA) study (NCT02247713). Teams delineated gross tumor volume of the primary tumor, during and after training interventions, according to a provided delineation protocol. In-house developed software recorded the performed delineations, to allow visual inspection of strategies and to assess delineation accuracy.
RESULTS: Following the first training, overall concordance indices for 3 repetitive cases increased from 0.57±0.07 to 0.66±0.07. The overall mean surface distance between observer and expert contours decreased from -0.40±0.03 cm to -0.01±0.33 cm. After further training overall concordance indices for another 3 repetitive cases further increased from 0.64±0.06 to 0.80±0.05 (p=0.01). Mean surface distances decreased from -0.34±0.16 cm to -0.05±0.20 cm (p=0.01).
CONCLUSION: Multiple training interventions improve PET/CT-based TVD delineation accuracy in NSCLC and reduces interobserver variation.
Resumo:
Hypertensive patients exhibit higher cardiovascular risk and reduced lung function compared with the general population. Whether this association stems from the coexistence of two highly prevalent diseases or from direct or indirect links of pathophysiological mechanisms is presently unclear. This study investigated the association between lung function and carotid features in non-smoking hypertensive subjects with supposed normal lung function. Hypertensive patients (n = 67) were cross-sectionally evaluated by clinical, hemodynamic, laboratory, and carotid ultrasound analysis. Forced vital capacity, forced expired volume in 1 second and in 6 seconds, and lung age were estimated by spirometry. Subjects with ventilatory abnormalities according to current guidelines were excluded. Regression analysis adjusted for age and prior smoking history showed that lung age and the percentage of predicted spirometric parameters associated with common carotid intima-media thickness, diameter, and stiffness. Further analyses, adjusted for additional potential confounders, revealed that lung age was the spirometric parameter exhibiting the most significant regression coefficients with carotid features. Conversely, plasma C-reactive protein and matrix-metalloproteinases-2/9 levels did not influence this relationship. The present findings point toward lung age as a potential marker of vascular remodeling and indicate that lung and vascular remodeling might share common pathophysiological mechanisms in hypertensive subjects.
Resumo:
This study tested whether myocardial extracellular volume (ECV) is increased in patients with hypertension and atrial fibrillation (AF) undergoing pulmonary vein isolation and whether there is an association between ECV and post-procedural recurrence of AF. Hypertension is associated with myocardial fibrosis, an increase in ECV, and AF. Data linking these findings are limited. T1 measurements pre-contrast and post-contrast in a cardiac magnetic resonance (CMR) study provide a method for quantification of ECV. Consecutive patients with hypertension and recurrent AF referred for pulmonary vein isolation underwent a contrast CMR study with measurement of ECV and were followed up prospectively for a median of 18 months. The endpoint of interest was late recurrence of AF. Patients had elevated left ventricular (LV) volumes, LV mass, left atrial volumes, and increased ECV (patients with AF, 0.34 ± 0.03; healthy control patients, 0.29 ± 0.03; p < 0.001). There were positive associations between ECV and left atrial volume (r = 0.46, p < 0.01) and LV mass and a negative association between ECV and diastolic function (early mitral annular relaxation [E'], r = -0.55, p < 0.001). In the best overall multivariable model, ECV was the strongest predictor of the primary outcome of recurrent AF (hazard ratio: 1.29; 95% confidence interval: 1.15 to 1.44; p < 0.0001) and the secondary composite outcome of recurrent AF, heart failure admission, and death (hazard ratio: 1.35; 95% confidence interval: 1.21 to 1.51; p < 0.0001). Each 10% increase in ECV was associated with a 29% increased risk of recurrent AF. In patients with AF and hypertension, expansion of ECV is associated with diastolic function and left atrial remodeling and is a strong independent predictor of recurrent AF post-pulmonary vein isolation.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Background: There are several studies in the literature depicting measurement error in gene expression data and also, several others about regulatory network models. However, only a little fraction describes a combination of measurement error in mathematical regulatory networks and shows how to identify these networks under different rates of noise. Results: This article investigates the effects of measurement error on the estimation of the parameters in regulatory networks. Simulation studies indicate that, in both time series (dependent) and non-time series (independent) data, the measurement error strongly affects the estimated parameters of the regulatory network models, biasing them as predicted by the theory. Moreover, when testing the parameters of the regulatory network models, p-values computed by ignoring the measurement error are not reliable, since the rate of false positives are not controlled under the null hypothesis. In order to overcome these problems, we present an improved version of the Ordinary Least Square estimator in independent (regression models) and dependent (autoregressive models) data when the variables are subject to noises. Moreover, measurement error estimation procedures for microarrays are also described. Simulation results also show that both corrected methods perform better than the standard ones (i.e., ignoring measurement error). The proposed methodologies are illustrated using microarray data from lung cancer patients and mouse liver time series data. Conclusions: Measurement error dangerously affects the identification of regulatory network models, thus, they must be reduced or taken into account in order to avoid erroneous conclusions. This could be one of the reasons for high biological false positive rates identified in actual regulatory network models.
Resumo:
The water diffusion attributable to concentration gradients is among the main mechanisms of water transport into the asphalt mixture. The transport of small molecules through polymeric materials is a very complex process, and no single model provides a complete explanation because of the small molecule`s complex internal structure. The objective of this study was to experimentally determine the diffusion of water in different fine aggregate mixtures (FAM) using simple gravimetric sorption measurements. For the purposes of measuring the diffusivity of water, FAMs were regarded as a representative homogenous volume of the hot-mix asphalt (HMA). Fick`s second law is generally used to model diffusion driven by concentration gradients in different materials. The concept of the dual mode diffusion was investigated for FAM cylindrical samples. Although FAM samples have three components (asphalt binder, aggregates, and air voids), the dual mode was an attempt to represent the diffusion process by only two stages that occur simultaneously: (1) the water molecules are completely mobile, and (2) the water molecules are partially mobile. The combination of three asphalt binders and two aggregates selected from the Strategic Highway Research Program`s (SHRP) Materials Reference Library (MRL) were evaluated at room temperature [23.9 degrees C (75 degrees F)] and at 37.8 degrees C (100 degrees F). The results show that moisture uptake and diffusivity of water through FAM is dependent on the type of aggregate and asphalt binder. At room temperature, the rank order of diffusivity and moisture uptake for the three binders was the same regardless of the type of aggregate. However, this rank order changed at higher temperatures, suggesting that at elevated temperatures different binders may be undergoing a different level of change in the free volume. DOI: 10.1061/(ASCE)MT.1943-5533.0000190. (C) 2011 American Society of Civil Engineers.
Resumo:
This work discusses a 4D lung reconstruction method from unsynchronized MR sequential images. The lung, differently from the heart, does not have its own muscles, turning impossible to see its real movements. The visualization of the lung in motion is an actual topic of research in medicine. CT (Computerized Tomography) can obtain spatio-temporal images of the heart by synchronizing with electrocardiographic waves. The FOV of the heart is small when compared to the lung`s FOV. The lung`s movement is not periodic and is susceptible to variations in the degree of respiration. Compared to CT, MR (Magnetic Resonance) imaging involves longer acquisition times and it is not possible to obtain instantaneous 3D images of the lung. For each slice, only one temporal sequence of 2D images can be obtained. However, methods using MR are preferable because they do not involve radiation. In this paper, based on unsynchronized MR images of the lung an animated B-Repsolid model of the lung is created. The 3D animation represents the lung`s motion associated to one selected sequence of MR images. The proposed method can be divided in two parts. First, the lung`s silhouettes moving in time are extracted by detecting the presence of a respiratory pattern on 2D spatio-temporal MR images. This approach enables us to determine the lung`s silhouette for every frame, even on frames with obscure edges. The sequence of extracted lung`s silhouettes are unsynchronized sagittal and coronal silhouettes. Using our algorithm it is possible to reconstruct a 3D lung starting from a silhouette of any type (coronal or sagittal) selected from any instant in time. A wire-frame model of the lung is created by composing coronal and sagittal planar silhouettes representing cross-sections. The silhouette composition is severely underconstrained. Many wire-frame models can be created from the observed sequences of silhouettes in time. Finally, a B-Rep solid model is created using a meshing algorithm. Using the B-Rep solid model the volume in time for the right and left lungs were calculated. It was possible to recognize several characteristics of the 3D real right and left lungs in the shaded model. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Obstruction of the fetal trachea is a potent stimulus for fetal lung growth and may have therapeutic potential in human fetuses with lung hypoplasia. However, the effects of increased lung expansion on lung development near midgestation, which is the preferred timing for fetal intervention, have not been well studied. Our aim was to determine the effects of increased lung expansion on lung development at 75-90 d of gestation in fetal sheep. In three groups of fetuses (n = 4 for each), the trachea was occluded for either 10 [10-d tracheal occlusion (TO) group] or 15 d (15-d TO group) or left intact (control fetuses). TO for both 10 and 15 d caused fetal hydrops, resulting in significantly increased fetal body weights. Both periods of TO significantly increased total lung DNA contents from 99.8 +/- 10.1 to 246.0 +/- 5.3 and 246.9 +/- 48.7 mg in 10- and 15-d TO fetuses, respectively. TO for 10 and 15 d also increased airspace diameter, although the percentage of lung occupied by airspace was not increased in 10-d TO fetuses due to large increases in interairway distances; this resulted from a large increase in mesenchymal tissue. The interairway distances at 15 d of TO were reduced compared with the 10-d value but were still similar to 30% larger than control values. We conclude that TO at
Resumo:
I noted with interest the article by Drs Perrin and Guex, entitled &dquo;Edema and leg volume: Methods of assessment,&dquo; published in Angiology 51:9-12, 2000. This was a timely and comprehensive review of the various methods in clinical use for the assessment of peripheral edema, notably in the leg. I would like to take this opportunity to alert readers to a further technique useful for this purpose, namely, bioelectrical impedance analysis. An early reportl described its use for the measurement of edema in the leg, but other than its successful use for the assessment of edema in the arm following masteCtoMy,2,1 the potential of the method remains to be fully realized. This is unfortunate since the method directly and quantifiably measures edema.
Resumo:
Background: Over-ventilation causing low arterial carbon dioxide levels (PaCO2) has been associated with the development of neonatal chronic lung disease and adverse outcomes. This may occur very soon after birth. Aim: To investigate the effect on PaCO2 and oxygenation of very premature lambs resuscitated with different tidal volumes and PEEP. Methods: Anaesthetised lambs delivered at 126 days gestation were randomised to 15 min resuscitation with 3 regimes: (1) Laerdal resuscitation bag (B) with 100% oxygen and no PEEP, (2) fixed tidal volume (VT) of 5 mL/kg, or (3) VT of 10 mL/kg, both delivered with a Babylog 8000 ventilator in volume guarantee mode with 8 cm H2O PEEP and variable FiO2. Frequent blood gases were measured and VT, mean airway pressure (Paw), minute volume (MV), ventilation rate (VR), respiratory system compliance (Crs) and alveolar/arterial oxygen difference (AaDO2) were recorded. Results: Twenty lambs were studied. B (1) was associated with more variable VT and peak inspiratory pressures (PIP) compared to fixed tidal volumes (2 and 3). The lambs ventilated with 10 mL/kg were over-ventilated, those ventilated with 5 mL/kg were slightly under-ventilated. Those ventilated with the Laerdal bag had a mean VT of 7.5 mL/kg and were normocarbic. The different tidal volumes had little effect on oxygenation. PEEP improved oxygenation. The table shows the values at 15 minutes expressed as mean and SEM. TABLE. No caption av... TABLE. No caption av... Image Tools Conclusion: Very premature lambs can be effectively resuscitated from birth using volume guarantee ventilation. Within minutes of birth different tidal volumes had a large effect on PaCO2 and no effect on oxygenation. Studies are needed to determine the appropriate tidal volume for resuscitating very premature infants to maintain acceptable levels of PaCO2. © International Pediatrics Research Foundation, Inc. 2004. All Rights Reserved.
Resumo:
The effects of prolonged recruitment manoeuvre (PRM) were compared with sustained inflation (SI) in paraquat-induced mild acute lung injury (ALI) in rats. Twenty-four hours after ALI induction, rats were anesthetized and mechanically ventilated with VT = 6 ml/kg and positive end-expiratory pressure (PEEP) = 5 cmH(2)O for 1 h. SI was performed with an instantaneous pressure increase of 40 cmH(2)O that was sustained for 40 s, while PRM was done by a step-wise increase in positive inspiratory pressure (PIP) of 15-20-25 cmH(2)O above a PEEP of 15 cm H(2)O (maximal PIP = 40 cmH(2)O), with interposed periods of PIP = 10 cmH(2)O above a PEEP = 15 cmH(2)O. Lung static elastance and the amount of alveolar collapse were more reduced with PRM than SI, yielding improved oxygenation. Additionally, tumour necrosis factor-alpha, interleukin-6, interferon-gamma, and type III procollagen mRNA expressions in lung tissue and lung epithelial cell apoptosis decreased more in PRM. In conclusion, PRM improved lung function, with less damage to alveolar epithelium, resulting in reduced pulmonary injury. (C) 2009 Elsevier BLV. All rights reserved.
Resumo:
Purpose: Many methods exist in the literature for identifying PEEP to set in ARDS patients following a lung recruitment maneuver (RM). We compared ten published parameters for setting PEEP following a RM. Methods: Lung injury was induced by bilateral lung lavage in 14 female Dorset sheep, yielding a PaO(2) 100-150 mmHg at F(I)O(2) 1.0 and PEEP 5 cmH(2)O. A quasi-static P-V curve was then performed using the supersyringe method; PEEP was set to 20 cmH(2)O and a RM performed with pressure control ventilation (inspiratory pressure set to 40-50 cmH(2)O), until PaO(2) + PaCO(2) > 400 mmHg. Following the RM, a decremental PEEP trial was performed. The PEEP was decreased in 1 cmH(2)O steps every 5 min until 15 cmH(2)O was reached. Parameters measured during the decremental PEEP trial were compared with parameters obtained from the P-V curve. Results: For setting PEEP, maximum dynamic tidal respiratory compliance, maximum PaO(2), maximum PaO(2) + PaCO(2), and minimum shunt calculated during the decremental PEEP trial, and the lower Pflex and point of maximal compliance increase on the inflation limb of the P-V curve (Pmci,i) were statistically indistinguishable. The PEEP value obtained using the deflation upper Pflex and the point of maximal compliance decrease on the deflation limb were significantly higher, and the true inflection point on the inflation limb and minimum PaCO(2) were significantly lower than the other variables. Conclusion: In this animal model of ARDS, dynamic tidal respiratory compliance, maximum PaO(2), maximum PaO(2) + PaCO(2), minimum shunt, inflation lower Pflex and Pmci,i yield similar values for PEEP following a recruitment maneuver.