956 resultados para Low Speed.
Resumo:
The aim of this study was to evaluate the effects of dentin surface treatments on the tensile bond strength (TBS) of the self-etching primer Clearfil SE Bond (CSE) and the one-step self-etching One-Up Bond F (OUB). The exposed flat dentin surfaces of twenty-four sound third molars were prepared with diamond bur at high-speed, carbide bur at low-speed or wet ground with #600 grit SiC paper. The adhesive systems were applied to the dentin surfaces and light-cured according to the manufacturers' instructions. A 6-mm high composite crown was incrementally built-up and each increment was light-cured for 40 seconds. After being stored in water (37°C/24 h), the samples were serially sectioned parallel to the long axis, forming beams (n = 20) with a cross-sectional area of approximately 0.8 mm 2. The specimens were tested in a Universal Testing Machine at 0.5 mm/min. The cross-sectional area was measured and the results (MPa) were analyzed by two-way ANOVA and Tukey Test (p < 0.05). Overall, the groups treated with CSE exhibited the highest TBS for all surface treatments. Dentin surfaces prepared with carbide bur at low speed reduced TBS in the CSE group; however, OUB was not affected by surface treatments. The effect of surface abrasive methods on TBS was material-dependent.
Resumo:
Methods based on visual estimation still is the most widely used analysis of the distances that is covered by soccer players during matches, and most description available in the literature were obtained using such an approach. Recently, systems based on computer vision techniques have appeared and the very first results are available for comparisons. The aim of the present study was to analyse the distances covered by Brazilian soccer players and compare the results to the European players', both data measured by automatic tracking system. Four regular Brazilian First Division Championship matches between different teams were filmed. Applying a previously developed automatic tracking system (DVideo, Campinas, Brazil), the results of 55 outline players participated in the whole game (n = 55) are presented. The results of mean distances covered, standard deviations (s) and coefficient of variation (cv) after 90 minutes were 10,012 m, s = 1,024 m and cv = 10.2%, respectively. The results of three-way ANOVA according to playing positions, showed that the distances covered by external defender (10642 ± 663 m), central midfielders (10476 ± 702 m) and external midfielders (10598 ± 890 m) were greater than forwards (9612 ± 772 m) and forwards covered greater distances than central defenders (9029 ± 860 m). The greater distances were covered in standing, walking, or jogging, 5537 ± 263 m, followed by moderate-speed running, 1731 ± 399 m; low speed running, 1615 ± 351 m; high-speed running, 691 ± 190 m and sprinting, 437 ± 171 m. Mean distance covered in the first half was 5,173 m (s = 394 m, cv = 7.6%) highly significant greater (p < 0.001) than the mean value 4,808 m (s = 375 m, cv = 7.8%) in the second half. A minute-by-minute analysis revealed that after eight minutes of the second half, player performance has already decreased and this reduction is maintained throughout the second half. ©Journal of Sports Science and Medicine (2007).
Resumo:
The influence of the type of rotary cutting instrument on bone repair after osteotomy in swine jaw, was evaluated using digital and densitometric radiographic examinations, at controlled times. Two cross-sectional dissections were made through the base of the right jaw, one using a high speed rotary instrument and the other using low speed, both with liquid cooling. After established periods the animals were sacrificed and their jaws removed for direct and indirect digital radiographic and densitometric studies using the CROMOX, DIGORA and ODR systems. In the initial periods (7 and 28 days) the bone density was higher in osteotomy areas performed with high rotation speeds, and in the final periods (60 and 90 days) the bone density was higher in the osteotomies performed with low rotation, indicating a better final bone repair with the use of low rotation. The qualitative analysis of the repair process was made by the ODR system which obtained three-dimensional and coloured digital images, which enable the bone thickness to be measured using an aluminium wedge. This showed that by twenty-eight days the bone repair was already apparently complete. © 2010 SECOM.
Resumo:
Introduction: An appropriate selection of instruments is essential to perform a correct debonding technique, by properly removing orthodontic brackets and the remaining resin. Objective: The aim of this study was to evaluate three methods of remaining resin removal on enamel surface after bracket debonding, by means of Scanning Electron Microscopy (SEM). Methods: Eighteen bovine incisors were selected and divided into three groups (A, B and C) of six teeth each. Before bracket bonding, epoxy resin casts were obtained by impression of the teeth with addition silicon, in order to register baseline enamel characteristics and representing the control group. The methods for remaining resin removal were: Group A - gross and medium granulation Soflex discs; Group B - carbide bur in low-speed; Group C - carbide bur in high-speed. Soflex polishing system fine and ultrafine granulation discs were used for Group A, rubber tips for Groups B and C, and polishing paste for all groups. After polishing, impression of teeth were taken and casts were analyzed by means of SEM. The baseline enamel characteristics (Control Group) were compared to the final aspect of enamel to determine the method that generated less enamel abrasion. Results and Conclusion: The remaining resin removal by carbide bur in low-rotation, and enamel polished with rubber tips followed by polishing paste produced the smaller damage to the enamel.
Resumo:
Taking into account the bone repair process in pigs has shown a greater similarity among the histological variables studied compared to other biological models, the present study has as its aim to evaluate the histological bone repair process of osteotomy performed on alveolar and extra-alveolar bones, using drilling tools with liquid refrigeration. Material and method: Eighteen Large White pigs weighing between 20 and 25 Kg were divided into three groups of six animals in order to evaluate the osteotomy repairs with low and high speed in the alveolar bone and threes in the extra-alveolar area, study periods of 7, 14 and 28 days. Results: It was observed that in the alveolar bone at the postoperative times of 14 and 28 days, the best repair results were in the osteotomy performed with low speed, while in the 7 day postoperative period, the results with high speed were slightly better, in alveolar areas as well as extra-alveolar areas. There no statistically significant differences between the alveolar and extra-alveolar bone repair process. Conclusions: The repair process, by means of microscopic analysis in the alveolar and extra-alveolar areas, are similar with better results observed in osteotomies performed with low speed drills in the 14 and 28 day study periods, and at 7 days postoperative the results with high speed drills and refrigeration were slightly better. Research works using pigs as an animal model are perfectly viable. © 2011 SECOM.
Resumo:
Pós-graduação em Ciências da Motricidade - IBRC
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciências Odontológicas - FOAR
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
No presente trabalho, foram feitos experimentos com a liga de Al – 0,6%Mg - 0,8%Si não refinada, com variações no teor de cobre (0,05% e 0,3%), que objetivaram avaliar dois aspectos do comportamento da liga. O primeiro aspecto diz respeito a afinidade entre esta e o molde, no qual busca se observar o efeito das variáveis térmicas de solidificação sobre a estrutura do fundido e sua correlação com propriedades mecânicas e elétricas, o segundo aspecto está relacionado com o comportamento intrínseco da variação da composição química quando submetida a baixas velocidades e taxas de resfriamento. Para a avaliação das variáveis térmicas de solidificação (velocidades das isotermas liquidus, taxas de resfriamento) utilizouse um dispositivo de solidificação unidirecional horizontal. Os lingotes produzidos a partir da solidificação da liga passaram pelos processos mecânicos de usinagem, laminação e trefilação, examinados em diferentes posições e diâmetros, através do ensaio de tração e condutividade elétrica. Foram analisadas as fraturas em função das microcavidades e diferentes concentrações de teores de cobre constatando-se que em relação ao material deformado a frio, o LRT tem uma tendência de crescimento para a liga de maior concentração de cobre. Os valores avaliados também possibilitaram concluir que a condutividade elétrica cresce quanto maior for o diâmetro das microcavidades e menor o teor de cobre. Com o objetivo de se avaliar somente o comportamento intrínseco da variação da composição química da liga, foi utilizado um segundo dispositivo de solidificação, molde em “U”, pintado internamente com solução de caulim que atribui ao molde baixas velocidades de resfriamento. Os resultados mostram que para os dois teores de cobre há uma tendência de crescimento do LRT com o aumento da redução sofrida pelas amostras, sendo o LRT maior para a liga com maior teor de cobre. Atribuímos este comportamento ao maior teor de soluto que por sua vez apresentou melhor resposta a deformação plástica, encruando mais o material. Entretanto, a caracterização elétrica ocorre de modo inverso, a exemplo do constatado na solidificação unidirecional, onde o menor teor de cobre foi mais eficiente.
Resumo:
The aim of this study was to evaluate the influence of chlorhexidine and Er, Cr:YSGG laser irradiation on the bond strength and external adaptation in mixed healthy and caries-affected class V cavities before and after thermal cycling. Thirty-six cavity preparations were made in mixed class V buccal human molars, half of them being artificially caries-induced. Any remaining affected dentin was removed from the cavity with a round burr at low speed. The teeth were divided into six groups, according to cleaning agent for both healthy and caries-induced dentin: no treatment, chlorhexidine and erbium, chromium-doped: yttrium, scandium, gallium, garnet (Er,Cr:YSGG) laser irradiation. A Filtek P90 (3M ESPE, St Paul, MN, USA) silorane adhesive restorative system was used. The specimens were subjected to 5000 thermal cycles (5-55 degrees C 60 min). Epoxy replicas were obtained to characterize the external adaptation under scanning electron microscopy. The average percentages of non-continuous margins were 5.41% and 6.49% in enamel dentin before thermal cycling and 25% and 33.7% after thermal cycling, respectively. The caries-affected and laser irradiated cavities showed higher non-continuous margins. Thermal cycling was able to raise the percentage of non-continuous margin for all groups. Chlorhexidine did not affect the marginal adaptation results, and the Er,Cr:YSGG laser irradiation showed significantly worse results compared with the control group.