907 resultados para Lingual wire


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Airway access is needed for a number of experimental animal models, and the majority of animal research is based on mouse models. Anatomical conditions in mice are small, and the narrow glottic opening allows intubation only with a subtle technique. We therefore developed a microscopic endotracheal intubation method with a wire guide technique in mice anaesthetized with halothane in oxygen. The mouse is hung perpendicularly with its incisors on a thread fixed on a vertical plate. The tongue is placed with a pair of forceps between the left hand's thumb and forefinger and slightly pulled, while the neck and thorax are positioned using the third and fourth fingers. By doing so, the neck can be slightly stretched, which allows optimal visualization of the larynx and the vocal cords. To ensure a safe intubation, a fine wire guide is placed under vision between the vocal cords and advanced about 5 mm into the trachea. An intravenous 22G x 1 in. plastic or Teflon catheter is guided over this wire. In a series of 41 mice, between 21 and 38 g, the success rate for the first intubation attempt was >95%. Certainty of the judgement procedure was 100% and success rate was higher using the described method when compared with a transillumination method in a further series. The technique is safe, less invasive than tracheostomy and suitable for controlled ventilation and pulmonary substance application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION The objective of this trial was to compare the survival rates of mandibular lingual retainers bonded with either chemically cured or light-cured adhesive after orthodontic treatment. METHODS Patients having undergone orthodontic treatment at a private orthodontic office were randomly allocated to fixed retainers placed with chemically cured composite or light-cured composite. Eligibility criteria included no active caries, restorations, or fractures on the mandibular anterior teeth, and adequate oral hygiene. The main outcome was any type of first-time lingual retainer breakage; pattern of failure (adapted adhesive remnant index scores) was a secondary outcome. Randomization was accomplished with random permuted blocks of 20 patients with allocation concealed in sequentially numbered, opaque, sealed envelopes. Blinding was applicable for outcome assessment only. Patients were reviewed at 1, 3, and 6 months and then every 6 months after placement of the retainer until completion of the study. Data were analyzed using survival analysis including Cox regression; sensitivity analysis was carried out after data imputation for subjects lost to follow-up. RESULTS Two hundred twenty patients (median age, 16 years; interquartile range, 2; range, 12-47 years) were randomized in a 1:1 ratio to either chemical or light curing. Baseline characteristics were similar between groups, the median follow-up period was 2.19 years (range, 0.003-3.64 years), and 16 patients were lost to follow-up. At a minimum follow-up of 2 years, 47 of 110 (42.7%) and 55 of 110 (50.0%) retainers had some type of failure with chemically cured and light-cured adhesive, respectively (log-rank test, P = 0.35). Data were analyzed on an intention-to-treat basis, and the hazard ratio (HR) was 1.15 (95% confidence interval [CI], 0.88-1.70; P = 0.47). There was weak evidence that age is a significant predictor for lingual retainer failures (HR, 0.96; 95% CI, 0.93-1.00; P = 0.08). Adhesive remnant index scoring was possible for only 66 of the 102 (64.7%) failures and did not differ between composites (Fisher exact test, P = 0.16). No serious harm was observed other than gingivitis associated with plaque accumulation. CONCLUSIONS The results of this study indicated no evidence that survival of mandibular lingual retainers differs between chemically and light-cured adhesives. The overall failure rate was 46.4%; however, this included any type of failure, which may have exaggerated the overall failure rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the prevalence of tooth wear on buccal/facial and lingual/palatal tooth surfaces and identify related risk factors in a sample of young European adults, aged 18-35 years. Calibrated and trained examiners measured tooth wear, using the basic erosive wear examination (BEWE) on in 3187 patients in seven European countries and assessed the impact of risk factors with a previously validated questionnaire. Each individual was characterized by the highest BEWE score recorded for any scoreable surface. Bivariate analyses examined the proportion of participants who scored 2 or 3 in relation to a range of demographic, dietary and oral care variables. The highest tooth wear BEWE score was 0 for 1368 patients (42.9%), 1 for 883 (27.7%), 2 for 831 (26.1%) and 3 for 105 (3.3%). There were large differences between different countries with the highest levels of tooth wear observed in the UK. Important risk factors for tooth wear included heartburn or acid reflux, repeated vomiting, residence in rural areas, electric tooth brushing and snoring. We found no evidence that waiting after breakfast before tooth brushing has any effect on the degree of tooth wear (p=0.088). Fresh fruit and juice intake was positively associated with tooth wear. In this adult sample 29% had signs of tooth wear making it a common presenting feature in European adults.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le collage d’un fil torsadé souple sur les faces linguales des six dents antérieures mandibulaires est une modalité de contention couramment utilisée. Les complications sont rares mais peuvent être assez sérieuses pour provoquer des dégâts biologiques. Cet article présente une complication sérieuse d’un fil de contention torsadé souple, collé en lingual. Quatre ans après son traitement orthodontique, un homme de 20 ans a consulté pour la rupture d’un fil de contention torsadé souple. L’examen clinique a montré un torque radiculo-vestibulaire d’environ 35° d’une dent. Une image en tomographie volumique à faisceau conique (Cone-Beam Computed Tomography ou CBCT) a montré que la racine et l’apex de la dent étaient presque totalement hors de l’os du côté vestibulaire. Étonnamment, la vitalité de la dent était préservée. La dent a été ramenée presque jusqu’à sa position initiale; cliniquement, seule une récession gingivale a persisté. Les orthodontistes et les dentistes devraient être conscients des complications possibles des contentions collées. Les patients devraient être clairement informés de la manière dont les problèmes peuvent être détectés à un stade précoce.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To investigate the composition and the microstructural and mechanical characterization of three different types of lingual brackets. MATERIALS AND METHODS Incognito™ (3M Unitek), In-Ovation L (DENTSPLY GAC) and STb™ (Light Lingual System, ORMCO) lingual brackets were studied under the scanning electron microscope employing backscattered electron imaging and their elemental composition was analysed by energy-dispersive X-ray microanalysis. Additionally, Vickers hardness was assessed using a universal hardness-testing machine, and the indentation modulus was measured according to instrumented indentation test. Two-way analysis of variance was conducted employing bracket type and location (base and wing) as discriminating variable. Significant differences among groups were allocated by post hoc Student-Newman-Keuls multiple comparison analysis at 95% level of significance. RESULTS Three different phases were identified for Incognito and In-Ovation L bracket based on mean atomic number contrast. On the contrary, STb did not show mean atomic contrast areas and thus it is recognized as a single phase. Incognito is a one-piece bracket with the same structure in wing and base regions. Incognito consists mainly of noble metals while In-Ovation L and STb show similar formulations of ferrous alloys in wing and base regions. No significant differences were found between ferrous brackets in hardness and modulus values, but there were significant differences between wing and base regions. Incognito illustrated intermediate values with significant differences from base and wing values of ferrous brackets. CONCLUSIONS/IMPLICATIONS Significant differences exist in microstructure, elemental composition, and mechanical properties among the brackets tested; these might have a series of clinical implications during mechanotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Venous angioplasty with stenting of iliac veins is an important treatment option for patients suffering from post-thrombotic syndrome due to chronic venous obstruction. Interventional treatment of a chronically occluded vena cava, however, is challenging and often associated with failure. We describe a case of a chronic total occlusion of the entire inferior vena cava that was successfully recanalized using bidirectional wire access and a balloon puncture by a re-entry catheter to establish patency of the inferior vena cava.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Submitted in partial fulfillment of the requirements for a Certificate in Orthodontics, Dept. of Orthodontics, University of Connecticut Health Center, 1986

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Wire, la serie concebida por David Simon a comienzo de la década pasada y emitida por HBO, es una de las pocas que puede presumir de ser llamada la mejor ficción creada para la televisión. Pero más allá de sus bondades artísticas, o precisamente por ellas, la mirada expansiva y total que realiza el programa sobre Baltimore, Maryland, en vísperas de nuestro siglo invita a que la utilicemos como punto de acceso para pensar el capitalismo, el crimen y la cuestión urbana en la actualidad. Pero por sobre todo, elaborar cómo estos términos interactúan en relaciones dialécticas que, en definitiva, producen la ciudad contemporánea

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Wire, la serie concebida por David Simon a comienzo de la década pasada y emitida por HBO, es una de las pocas que puede presumir de ser llamada la mejor ficción creada para la televisión. Pero más allá de sus bondades artísticas, o precisamente por ellas, la mirada expansiva y total que realiza el programa sobre Baltimore, Maryland, en vísperas de nuestro siglo invita a que la utilicemos como punto de acceso para pensar el capitalismo, el crimen y la cuestión urbana en la actualidad. Pero por sobre todo, elaborar cómo estos términos interactúan en relaciones dialécticas que, en definitiva, producen la ciudad contemporánea

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Wire, la serie concebida por David Simon a comienzo de la década pasada y emitida por HBO, es una de las pocas que puede presumir de ser llamada la mejor ficción creada para la televisión. Pero más allá de sus bondades artísticas, o precisamente por ellas, la mirada expansiva y total que realiza el programa sobre Baltimore, Maryland, en vísperas de nuestro siglo invita a que la utilicemos como punto de acceso para pensar el capitalismo, el crimen y la cuestión urbana en la actualidad. Pero por sobre todo, elaborar cómo estos términos interactúan en relaciones dialécticas que, en definitiva, producen la ciudad contemporánea

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Wire, la serie concebida por David Simon a comienzo de la década pasada y emitida por HBO, es una de las pocas que puede presumir de ser llamada la mejor ficción creada para la televisión. Pero más allá de sus bondades artísticas, o precisamente por ellas, la mirada expansiva y total que realiza el programa sobre Baltimore, Maryland, en vísperas de nuestro siglo invita a que la utilicemos como punto de acceso para pensar el capitalismo, el crimen y la cuestión urbana en la actualidad. Pero por sobre todo, elaborar cómo estos términos interactúan en relaciones dialécticas que, en definitiva, producen la ciudad contemporánea

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study is to determine the critical wear levels of the contact wire of the catenary on metropolitan lines. The study has focussed on the zones of contact wire where localised wear is produced, normally associated with the appearance of electric arcs. To this end, a finite element model has been developed to study the dynamics of pantograph-catenary interaction. The model includes a zone of localised wear and a singularity in the contact wire in order to simulate the worst case scenario from the point of view of stresses. In order to consider the different stages in the wire wear process, different depths and widths of the localised wear zone were defined. The results of the dynamic simulations performed for each stage of wear let the area of the minimum resistant section of the contact wire be determined for which stresses are greater than the allowable stress. The maximum tensile stress reached in the contact wire shows a clear sensitivity to the size of the local wear zone, defined by its width and depth. In this way, if the wear measurements taken with an overhead line recording vehicle are analysed, it will be possible to calculate the potential breakage risk of the wire. A strong dependence of the tensile forces of the contact wire has also been observed. These results will allow priorities to be set for replacing the most critical sections of wire, thereby making maintenance much more efficient. The results obtained show that the wire replacement criteria currently borne in mind have turned out to be appropriate, although in some wear scenarios these criteria could be adjusted even more, and so prolong the life cycle of the contact wire.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, the Semantic Web has experienced significant advancements in standards and techniques, as well as in the amount of semantic information available online. Nevertheless, mechanisms are still needed to automatically reconcile information when it is expressed in different natural languages on the Web of Data, in order to improve the access to semantic information across language barriers. In this context several challenges arise [1], such as: (i) ontology translation/localization, (ii) cross-lingual ontology mappings, (iii) representation of multilingual lexical information, and (iv) cross-lingual access and querying of linked data. In the following we will focus on the second challenge, which is the necessity of establishing, representing and storing cross-lingual links among semantic information on the Web. In fact, in a “truly” multilingual Semantic Web, semantic data with lexical representations in one natural language would be mapped to equivalent or related information in other languages, thus making navigation across multilingual information possible for software agents.