987 resultados para Legislative power.
Resumo:
World economies increasingly demand reliable and economical power supply and distribution. To achieve this aim the majority of power systems are becoming interconnected, with several power utilities supplying the one large network. One problem that occurs in a large interconnected power system is the regular occurrence of system disturbances which can result in the creation of intra-area oscillating modes. These modes can be regarded as the transient responses of the power system to excitation, which are generally characterised as decaying sinusoids. For a power system operating ideally these transient responses would ideally would have a “ring-down” time of 10-15 seconds. Sometimes equipment failures disturb the ideal operation of power systems and oscillating modes with ring-down times greater than 15 seconds arise. The larger settling times associated with such “poorly damped” modes cause substantial power flows between generation nodes, resulting in significant physical stresses on the power distribution system. If these modes are not just poorly damped but “negatively damped”, catastrophic failures of the system can occur. To ensure system stability and security of large power systems, the potentially dangerous oscillating modes generated from disturbances (such as equipment failure) must be quickly identified. The power utility must then apply appropriate damping control strategies. In power system monitoring there exist two facets of critical interest. The first is the estimation of modal parameters for a power system in normal, stable, operation. The second is the rapid detection of any substantial changes to this normal, stable operation (because of equipment breakdown for example). Most work to date has concentrated on the first of these two facets, i.e. on modal parameter estimation. Numerous modal parameter estimation techniques have been proposed and implemented, but all have limitations [1-13]. One of the key limitations of all existing parameter estimation methods is the fact that they require very long data records to provide accurate parameter estimates. This is a particularly significant problem after a sudden detrimental change in damping. One simply cannot afford to wait long enough to collect the large amounts of data required for existing parameter estimators. Motivated by this gap in the current body of knowledge and practice, the research reported in this thesis focuses heavily on rapid detection of changes (i.e. on the second facet mentioned above). This thesis reports on a number of new algorithms which can rapidly flag whether or not there has been a detrimental change to a stable operating system. It will be seen that the new algorithms enable sudden modal changes to be detected within quite short time frames (typically about 1 minute), using data from power systems in normal operation. The new methods reported in this thesis are summarised below. The Energy Based Detector (EBD): The rationale for this method is that the modal disturbance energy is greater for lightly damped modes than it is for heavily damped modes (because the latter decay more rapidly). Sudden changes in modal energy, then, imply sudden changes in modal damping. Because the method relies on data from power systems in normal operation, the modal disturbances are random. Accordingly, the disturbance energy is modelled as a random process (with the parameters of the model being determined from the power system under consideration). A threshold is then set based on the statistical model. The energy method is very simple to implement and is computationally efficient. It is, however, only able to determine whether or not a sudden modal deterioration has occurred; it cannot identify which mode has deteriorated. For this reason the method is particularly well suited to smaller interconnected power systems that involve only a single mode. Optimal Individual Mode Detector (OIMD): As discussed in the previous paragraph, the energy detector can only determine whether or not a change has occurred; it cannot flag which mode is responsible for the deterioration. The OIMD seeks to address this shortcoming. It uses optimal detection theory to test for sudden changes in individual modes. In practice, one can have an OIMD operating for all modes within a system, so that changes in any of the modes can be detected. Like the energy detector, the OIMD is based on a statistical model and a subsequently derived threshold test. The Kalman Innovation Detector (KID): This detector is an alternative to the OIMD. Unlike the OIMD, however, it does not explicitly monitor individual modes. Rather it relies on a key property of a Kalman filter, namely that the Kalman innovation (the difference between the estimated and observed outputs) is white as long as the Kalman filter model is valid. A Kalman filter model is set to represent a particular power system. If some event in the power system (such as equipment failure) causes a sudden change to the power system, the Kalman model will no longer be valid and the innovation will no longer be white. Furthermore, if there is a detrimental system change, the innovation spectrum will display strong peaks in the spectrum at frequency locations associated with changes. Hence the innovation spectrum can be monitored to both set-off an “alarm” when a change occurs and to identify which modal frequency has given rise to the change. The threshold for alarming is based on the simple Chi-Squared PDF for a normalised white noise spectrum [14, 15]. While the method can identify the mode which has deteriorated, it does not necessarily indicate whether there has been a frequency or damping change. The PPM discussed next can monitor frequency changes and so can provide some discrimination in this regard. The Polynomial Phase Method (PPM): In [16] the cubic phase (CP) function was introduced as a tool for revealing frequency related spectral changes. This thesis extends the cubic phase function to a generalised class of polynomial phase functions which can reveal frequency related spectral changes in power systems. A statistical analysis of the technique is performed. When applied to power system analysis, the PPM can provide knowledge of sudden shifts in frequency through both the new frequency estimate and the polynomial phase coefficient information. This knowledge can be then cross-referenced with other detection methods to provide improved detection benchmarks.
Resumo:
This research used the Queensland Police Service, Australia, as a major case study. Information on principles, techniques and processes used, and the reason for the recording, storing and release of audit information for evidentiary purposes is reported. It is shown that Law Enforcement Agencies have a two-fold interest in, and legal obligation pertaining to, audit trails. The first interest relates to the situation where audit trails are actually used by criminals in the commission of crime and the second to where audit trails are generated by the information systems used by the police themselves in support of the recording and investigation of crime. Eleven court cases involving Queensland Police Service audit trails used in evidence in Queensland courts were selected for further analysis. It is shown that, of the cases studied, none of the evidence presented was rejected or seriously challenged from a technical perspective. These results were further analysed and related to normal requirements for trusted maintenance of audit trail information in sensitive environments with discussion on the ability and/or willingness of courts to fully challenge, assess or value audit evidence presented. Managerial and technical frameworks for firstly what is considered as an environment where a computer system may be considered to be operating “properly” and, secondly, what aspects of education, training, qualifications, expertise and the like may be considered as appropriate for persons responsible within that environment, are both proposed. Analysis was undertaken to determine if audit and control of information in a high security environment, such as law enforcement, could be judged as having improved, or not, in the transition from manual to electronic processes. Information collection, control of processing and audit in manual processes used by the Queensland Police Service, Australia, in the period 1940 to 1980 was assessed against current electronic systems essentially introduced to policing in the decades of the 1980s and 1990s. Results show that electronic systems do provide for faster communications with centrally controlled and updated information readily available for use by large numbers of users who are connected across significant geographical locations. However, it is clearly evident that the price paid for this is a lack of ability and/or reluctance to provide improved audit and control processes. To compare the information systems audit and control arrangements of the Queensland Police Service with other government departments or agencies, an Australia wide survey was conducted. Results of the survey were contrasted with the particular results of a survey, conducted by the Australian Commonwealth Privacy Commission four years previous, to this survey which showed that security in relation to the recording of activity against access to information held on Australian government computer systems has been poor and a cause for concern. However, within this four year period there is evidence to suggest that government organisations are increasingly more inclined to generate audit trails. An attack on the overall security of audit trails in computer operating systems was initiated to further investigate findings reported in relation to the government systems survey. The survey showed that information systems audit trails in Microsoft Corporation's “Windows” operating system environments are relied on quite heavily. An audit of the security for audit trails generated, stored and managed in the Microsoft “Windows 2000” operating system environment was undertaken and compared and contrasted with similar such audit trail schemes in the “UNIX” and “Linux” operating systems. Strength of passwords and exploitation of any security problems in access control were targeted using software tools that are freely available in the public domain. Results showed that such security for the “Windows 2000” system is seriously flawed and the integrity of audit trails stored within these environments cannot be relied upon. An attempt to produce a framework and set of guidelines for use by expert witnesses in the information technology (IT) profession is proposed. This is achieved by examining the current rules and guidelines related to the provision of expert evidence in a court environment, by analysing the rationale for the separation of distinct disciplines and corresponding bodies of knowledge used by the Medical Profession and Forensic Science and then by analysing the bodies of knowledge within the discipline of IT itself. It is demonstrated that the accepted processes and procedures relevant to expert witnessing in a court environment are transferable to the IT sector. However, unlike some discipline areas, this analysis has clearly identified two distinct aspects of the matter which appear particularly relevant to IT. These two areas are; expertise gained through the application of IT to information needs in a particular public or private enterprise; and expertise gained through accepted and verifiable education, training and experience in fundamental IT products and system.