997 resultados para Laser-Frequency Modulation
Resumo:
In this work, Ba0.8Sr0.2TiO3 (BST)/ITO structures were grown on glass substrate and laser assisted annealing (LAA) was performed to promote the crystallization of BST. Atomic force microscopy and X-ray diffraction studies confirm the crack free and polycrystalline perovskite phase of BST. White light controlled resistive switching (RS) effect in Au/BST/ITO device is investigated. The device displays the electroforming-free bipolar RS characteristics and are explained by the modulationof the width and height of barrier at the BST/ITO interface via ferroelectric polarization. Moreover, the RS effect is signifi- cantly improved under white light illumination compared to that in the dark. The enhanced RS and photovoltaic effects are explained by considering depolarization field and charge distribution at the interface. The devices exhibit stable retention characteristics with low currents (mA), which make them attractive for non volatile memory devices.
Resumo:
OBJECTIVE: To analyze the heart rate variability in patients with mild to moderate systemic arterial hypertension. METHODS: Thirty-two healthy (group I) and 70 systemic arterial hypertensive (group II) individuals, divided according to age (40 to 59 and 60 to 80 years old, respectively) and with a similar distribution by sex were studied. Thirty-one had left ventricular hypertrophy (LVH), 22 were overweight, and 16 had Type II diabetes mellitus. Smoking, alcohol ingestion, and sedentary habits were the same between groups. Variability in heart rate was analyzed in the time domain, using standard deviations of normal RR intervals (SDNN) and the differences between maximal brady- and tachycardia (D-BTmax) during sustained inspiration. Analysis of the frequency band of the power spectrum between 0.05 and 0.40 Hz at rest and during controlled respiration was chosen for analysis of the frequency domain. RESULTS: In both time and frequency domains, variables were lower in group II than in group I. Within groups, statistically significant variables were only found for individuals in the 40 to 59 year old group. The presence of LVH, overweight, or diabetes mellitus did not influence the variability in heart rate to a significant extent. CONCLUSION: Variability in heart rate was a valuable instrument for analyzing autonomic modulation of the heart in arterial hypertension. The autonomic system undergoes significant losses in cardio-modulatory capacity, more evident in subjects between 40 and 59 years old. In those over 60 years old, reduced variability in heart rate imposed by aging was not significantly influenced by the presence of systemic arterial hypertension.
Resumo:
Systemic arterial hypertension (SAH) is considered to be the greatest risk factor for the development of neuro-cardiovascular pathologies, thus constituting a severe Public Health issue in the world. The Low-Level Laser Therapy (LLLT), or laser therapy, activates components of the cellular structure, therefore converting luminous energy into photochemical energy and leading to biophysical and biochemical reactions in the mitochondrial respiratory chain. The LLLT promotes cellular and tissue photobiomodulation by means of changes in metabolism, leading to molecular, cellular and systemic changes. The objective of this study was to analyze the action of low-level laser in the hemodynamic modulation of spontaneously hypertensive rats, in the long term. Animals (n = 16) were randomly divided into the Laser Group (n = 8), which received three weekly LLLT irradiations for seven weeks, and into the Sham Group (n = 8), which received three weekly simulations of laser for seven weeks, accounting for 21 applications in each group. After seven weeks, animals were cannulated by the implantation of a catheter in the left carotid artery. On the following day, the systemic arterial pressure was recorded. The Laser Group showed reduced levels of mean blood pressure, with statistically significant reduction (169 ± 4 mmHg* vs. 182 ± 4 mmHg from the Sham Group) and reduced levels of diastolic pressure (143 ± 4 mmHg* vs. 157 ± 3 mmHg from the Sham Group), revealing a 13 and 14 mmHg decrease, respectively. Besides, there was a concomitant important decline in heart rate (312 ± 14 bpm vs. 361 ± 13 bpm from the Sham Group). Therefore, laser therapy was able to produce hemodynamic changes, thus reducing pressure levels in spontaneously hypertensive rats.
Resumo:
Abstract Background: Smoking consumption alters cardiac autonomic function. Objective: Assess the influence of the intensity of smoking and the nicotine dependence degree in cardiac autonomic modulation evaluated through index of heart rate variability (HRV). Methods: 83 smokers, of both genders, between 50 and 70 years of age and with normal lung function were divided according to the intensity of smoking consumption (moderate and severe) and the nicotine dependency degree (mild, moderate and severe). The indexes of HRV were analyzed in rest condition, in linear methods in the time domain (TD), the frequency domain (FD) and through the Poincaré plot. For the comparison of smoking consumption, unpaired t test or Mann-Whitney was employed. For the analysis between the nicotine dependency degrees, we used the One-way ANOVA test, followed by Tukey's post test or Kruskal-Wallis followed by Dunn's test. The significance level was p < 0,05. Results: Differences were only found when compared to the different intensities of smoking consumption in the indexes in the FD. LFun (62.89 ± 15.24 vs 75.45 ± 10.28), which corresponds to low frequency spectrum component in normalized units; HFun (37.11 ± 15.24 vs 24.55 ± 10.28), which corresponds to high frequency spectrum component in normalized units and in the LF/HF ratio (2.21 ± 1.47 vs 4.07 ± 2.94). However, in the evaluation of nicotine dependency, significant differences were not observed (p > 0.05). Conclusion: Only the intensity of smoking consumption had an influence over the cardiac autonomic modulation of the assessed tobacco smokers. Tobacco smokers with severe intensity of smoking consumption presented a lower autonomic modulation than those with moderate intensity.
Resumo:
Abnormalities in the topology of brain networks may be an important feature and etiological factor for psychogenic non-epileptic seizures (PNES). To explore this possibility, we applied a graph theoretical approach to functional networks based on resting state EEGs from 13 PNES patients and 13 age- and gender-matched controls. The networks were extracted from Laplacian-transformed time-series by a cross-correlation method. PNES patients showed close to normal local and global connectivity and small-world structure, estimated with clustering coefficient, modularity, global efficiency, and small-worldness (SW) metrics, respectively. Yet the number of PNES attacks per month correlated with a weakness of local connectedness and a skewed balance between local and global connectedness quantified with SW, all in EEG alpha band. In beta band, patients demonstrated above-normal resiliency, measured with assortativity coefficient, which also correlated with the frequency of PNES attacks. This interictal EEG phenotype may help improve differentiation between PNES and epilepsy. The results also suggest that local connectivity could be a target for therapeutic interventions in PNES. Selective modulation (strengthening) of local connectivity might improve the skewed balance between local and global connectivity and so prevent PNES events.
Resumo:
Direct electrical stimulation of the colon offers a promising approach for the induction of propulsive colonic contractions by using an implantable device. The objective of this study was to assess the feasibility to induce colonic contractions using a commercially available battery-operated stimulator (maximum pulse width of 1 ms and maximum amplitude of 10 V). Three pairs of pacing electrodes were inserted into the cecal seromuscular layer of anesthetized pigs. During a first set of in vivo experiments conducted on six animals, a pacing protocol leading to cecum contractions was determined: stimulation bursts with 1 ms pulse width, 10 V amplitude (7-15 mA), 120 Hz frequency, and 30-s burst duration, repeated every 2-5 min. In a second testing phase, an evaluation of the pacing protocol was performed in four animals (120 stimulation bursts in total). By using the battery-operated stimulator, contractions of the cecum and movement of contents could be induced in 92% of all stimulations. A cecal shortening of about 30% and an average intraluminal pressure increase of 10.0 +/- 6.0 mmHg were observed.
Resumo:
La trachée et les bronches proximales sont de fins conduits subtils, ingénieusement structurés par une partie cartilagineuse antérieure résistante aux variations de pression et une partie membraneuse postérieure souple. Par leurs faibles volumes (espace mort) ils délivrent un grand pourcentage de l'air inspiré aux voies distales, puis au parenchyme pulmonaire, permettant les échanges de gaz. Cette belle harmonie respiratoire peut être rapidement mise à mal dès qu'un processus atteint ces voies respiratoires proximales, soit en les comprimant, processus sténosant, soit en affaiblissant leur structure, trachéo-bronchomalacie, soit en ouvrant leur paroi sur les structures médiastinales, fistule trachéo/broncho-médiastinales, pleurales ou autres. Le pronostic vital est alors rapidement engagé au vu de l'absolue nécessité du bon fonctionnement de ces fins conduits, une petite diminution du calibre de leurs fines lumières provoquant une baisse importante de leurs surfaces. Dans ces situations à haut potentiel de complication majeure les interventions endoscopiques pour restaurer l'intégrité de ces conduits sont alors fort risquées, et il est primordial de pouvoir les effectuer dans un cadre sécurisé au maximum. La réalisation de ces gestes par la technique décrite dans notre article « Use of combined suspension laryngoscopy, flexible bronchoscopy and high frequency jet ventilation forY-shaped airway stents delivery" permet la sécurité nécessaire à ces situations instable, en effet -la laryngoscopie en suspension expose les voies proximales en offrant un accès le plus large possible à l'arbre trachéobronchique ce qui permet l insertion de multiples instruments parfois volumineux, -la Jet ventilation assure une oxygénation et une ventilation adéquate par un fin cathéter placé soit dans le poumon sain, soit en distalité de la lésion -la bronchoscopie souple, passant au travers d'endroits exigus et courbes permet le déploiement sous vision direct, au millimètre près, de divers dispositifs. Cette association remplace avantageusement la technique traditionnelle qui insère les stents à l'aveugle, et en apnée, ce qui représente de haut risque de mauvais positionnement des stents avec des conséquences immédiates sur l'oxygénation et la ventilation souvent déjà bien altérées. Perspective et conclusion : cette technique est utile pour l'insertion des stents en Y, centraux, comme décrit dans notre article, et les indications peuvent être étendues aux stents distaux pour lesquels l'accès n'est parfois pas aisé avec le bronchoscope rigide, et pour d'autres interventions endoscopiques, laser, cryothérapie, radiofréquence ou l'insertion de nouveaux dispositifs.
Resumo:
Extensive theoretical and experimental work on the neuronal correlates of visual attention raises two hypotheses about the underlying mechanisms. The first hypothesis, named biased competition, originates from experimental single-cell recordings that have shown that attention upmodulates the firing rates of the neurons encoding the attended features and downregulates the firing rates of the neurons encoding the unattended features. Furthermore, attentional modulation of firing rates increases along the visual pathway. The other, newer hypothesis assigns synchronization a crucial role in the attentional process. It stems from experiments that have shown that attention modulates gamma-frequency synchronization. In this paper, we study the coexistence of the two phenomena using a theoretical framework. We find that the two effects can vary independently of each other and across layers. Therefore, the two phenomena are not concomitant. However, we show that there is an advantage in the processing of information if rate modulation is accompanied by gamma modulation, namely that reaction times are shorter, implying behavioral relevance for gamma synchronization.
Resumo:
To determine whether skin blood flow is local or takes part in general regulatory mechanisms, we recorded laser-Doppler flowmetry (LDF; left and right index fingers), blood pressure, muscle sympathetic nerve activity (MSNA), R-R interval, and respiration in 10 healthy volunteers and 3 subjects after sympathectomy. We evaluated 1) the synchronism of LDF fluctuations in two index fingers, 2) the relationship with autonomically mediated fluctuations in other signals, and 3) the LDF ability to respond to arterial baroreflex stimulation (by neck suction at frequencies from 0.02 to 0.20 Hz), using spectral analysis (autoregressive uni- and bivariate, time-variant algorithms). Synchronous LDF fluctuations were observed in the index fingers of healthy subjects but not in sympathectomized patients. LDF fluctuations were coherent with those obtained for blood pressure, MSNA, and R-R interval. LDF fluctuations were leading blood pressure in the low-frequency (LF; 0.1 Hz) band and lagging in the respiratory, high-frequency (HF; approximately 0.25 Hz) band, suggesting passive "downstream" transmission only for HF and "upstream" transmission for LF from the microvessels. LDF fluctuations were responsive to sinusoidal neck suction up to 0.1 Hz, indicating response to sympathetic modulation. Skin blood flow thus reflects modifications determined by autonomic activity, detectable by frequency analysis of spontaneous fluctuations.
Resumo:
The frequency dynamics of gain-switched singlemode semiconductor lasers subject to optical injection is investigated. The requirements for low time jitter and reduced frequency chirp operation are studied as a function of the frequency mismatch between the master and slave lasers. Suppression of the power overshoot, typical during gain-switched operation, can be achieved for selected frequency detunings.
Resumo:
We investigate within mean-field theory the influence of a one-dimensional optical lattice and of trapped degenerate fermions on the critical rotational frequency for vortex line creation in a Bose-Einstein condensate. We consider laser intensities of the lattice such that quantum coherence across the condensate is ensured. We find a sizable decrease of the thermodynamic critical frequency for vortex nucleation with increasing applied laser strength and suggest suitable parameters for experimental observation. Since 87Rb-40K mixtures may undergo collapse, we analyze the related question of how the optical lattice affects the mechanical stability of the system.
Resumo:
To determine self‐consistently the time evolution of particle size and their number density in situ multi‐angle polarization‐sensitive laser light scattering was used. Cross‐polarization intensities (incident and scattered light intensities with opposite polarization) measured at 135° and ex situ transmission electronic microscopy analysis demonstrate the existence of nonspherical agglomerates during the early phase of agglomeration. Later in the particle time development both techniques reveal spherical particles again. The presence of strong cross‐polarization intensities is accompanied by low‐frequency instabilities detected on the scattered light intensities and plasma emission. It is found that the particle radius and particle number density during the agglomeration phase can be well described by the Brownian free molecule coagulation model. Application of this neutral particle coagulation model is justified by calculation of the particle charge whereby it is shown that particles of a few tens of nanometer can be considered as neutral under our experimental conditions. The measured particle dispersion can be well described by a Brownian free molecule coagulation model including a log‐normal particle size distribution.
Resumo:
BACKGROUND/AIMS: Endocrine features of polycystic ovary syndrome (PCOS) include altered ovarian steroidogenesis, hyperinsulinemia and abnormal luteinizing hormone (LH) secretion. This study was undertaken to further evaluate the role of insulin to modulate LH secretion in lean PCOS patients with normal insulin sensitivity and normal volunteers. METHODS: The study was performed in five nonobese patients diagnosed with PCOS on the basis of amenorrhea and a polycystic morphology at ovarian ultrasound, and 5 normal controls in early to mid-follicular phase and matched for weight and age. All subjects were phenotyped, and then admitted for 12 h of frequent (q 10') blood sampling on two separate occasions, once for a baseline study and the other time for a hyperinsulinemic and euglycemic clamp study. LH was measured in samples obtained throughout each admission in order to perform LH pulse analysis. RESULTS: Baseline LH secretion in PCOS subjects was significantly different from controls: they had higher LH levels, higher LH/FSH ratios as well as a faster LH pulse frequency than normal women. Insulin administration did not affect the pattern of LH secretion of PCOS patients, whereas it significantly increased the LH pulse frequency while decreasing the LH interpulse intervals in the controls. CONCLUSIONS: These data confirm that an abnormal pattern of LH secretion characteristic of PCOS can be observed in lean patients, and appears independent of peripheral insulin levels. Furthermore, our results in lean controls provide the first direct evidence that peripheral insulin can modulate the activity of hypothalamic gonadotropin-releasing hormone (GnRH) neurons in the human.
Resumo:
RESUME Les membranes néovasculaires (MNV) compliquent diverses pathologies ophtalmiques. Elles sont à l'origine d'une importante baisse de l'acuité visuelle lorsque elles se situent à proximité de la fovéa. A l'heure actuelle, peu de données relatives à leur association aux pathologies inflammatoires de l'oeil (uvéites) existent. Dans ce travail, la fréquence de MNV a été évaluée parmi 643 patients avec uvéite. Leur impact sur l'acuité visuelle ainsi que le pronostic en fonction des différents traitements effectués ont été étudiés. Les dossiers des 643 patients souffrant d'uvéite ont été étudiés. Les patients présentant une MNV ont été classés en trois groupes en fonction de l'importance de l'inflammation intraoculaire: élevée (2+ cellules dans le vitré), moyenne (1/2+ à 1+ cellules dans le vitré) ou absente (0 cellules dans le vitré). L'évolution de l'acuité visuelle fut considérée comme favorable (+VA: maintient de l'acuité visuelle ou gain d'une ou plusieurs lignes de Snellen) ou défavorable (-VA: perte d'une ou plusieurs lignes Snellen). Chez 9 patients, le traitement instauré a consisté, initialement, en l'administration orale de corticostéroïdes (CST) à haute dose qui, dans le cas d'évolution favorable (-FVA ou régression angiographique de la MNV), était arrêtée en doses dégressives. Dans les évolutions défavorables (-VA ou progression angiographique de la MNV), les CST étaient maintenus à dose moyenne en complémentation d'un traitement par thérapie laser (photothérapie dynamique (PDT), thermothérapie transpupillaire (TTT) ou laser Argon). Ce protocole thérapeutique ne fut appliqué chez trois patients en raison de la non disponibilité de PDT ou d'un diagnostic manqué d'uvéite. Douze patients sur 643 avec uvéite ont présenté une MNV. L'impact visuel moyen était de 4.5 lignes de Snellen et le temps moyen de suivi était de 19.5 mois. Deux patients avec inflammation intraoculaire élevée ont évolué favorablement sous CST seuls. Huit patients avec inflammation intraoculaire moyenne ont évolué favorablement sous CST seuls chez trois patients, alors que quatre patients ont nécessité une thérapie laser additionnelle. Le dernier patient ne fut traité que par thérapie laser sans CST (diagnostic manqué d'uvéite). Deux patients sans inflammation intraoculaire ont eu un pronostic défavorable sous CST seuls (pas d'autre alternative thérapeutique). Notre étude a démontré que les MNV sont une complication rare de l'uvéite qui, après traitement adéquat, ont un pronostic visuel relativement favorable. Bien que les CST semblent être la première modalité thérapeutique, les traitements laser devraient être adoptés tôt dans les situations d'inflammation intraoculaire moyenne ou absente.
Resumo:
The purpose of this study was to evaluate the intraocular pressure (IOP)-lowering effect of modified goniopuncture with the 532-nm Nd : YAG selective laser trabeculoplasty (SLT) laser on eyes after deep sclerectomy with collagen implant (DSCI). This was an interventional cased series. The effects of modified goniopuncture on eyes with insufficient IOP-lowering after DSCI were observed. Goniopuncture was performed using a Q-switched, frequency-doubled 532-nm Nd : YAG laser (SLT-goniopuncture, SLT-G). Outcome measures were amount of IOP-lowering and rapidity of decrease after laser intervention. In all, 10 eyes of 10 patients with a mean age of 71.0±7.7 (SD) years were treated with SLT-G. The mean time of SLT-G after DSCI procedure was 7.1±10.9 months. SLT-G decreased IOP from an average of 16.1±3.4 mm Hg to 14.2±2.8 mm Hg (after 15 min), 13.6±3.9 mm Hg (at 1 day), 12.5±4.1 mm Hg (at 1 month), and 12.6±2.5 (at 6 months) (P<0.0125). There were no complications related to the intervention. Patients in this series achieved an average 22.5% of IOP reduction after SLT-G. The use of the SLT laser appears to be an effective and safe alternative to the traditional Nd : YAG laser for goniopuncture in eyes after DSCI, with potential advantages related to non-perforation of trabeculo-descemet's membrane (TDM).