918 resultados para Laser therapy of low intensity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The two-dimensional laser-plasma-interaction hydrodynamic code POLLUX has been used to simulate the ablation of a magnesium target by a 30-ns, 248-nm KrF excimer laser at low laser fluences of ≤10 J cm2. This code, originally written for much higher laser intensities, has been recently extended to include a detailed description of the equation of state in order to treat changes of phase within the target material, and also includes a Thomas Fermi description of the electrons. The simulated temporal and spatial evolution of the plasma plume in the early phase of the expansion (≤100 ns) is compared with experimental interferometric measurements of electron density. The expansion dynamics are in good agreement, although the simulated electron number density is about 2.5 times higher than the experimental values.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Assess efficacy and acceptability of reduced intensity constraint-induced movement therapy (CIMT) in children with cerebral palsy (CP).

METHODS: Single-subject research design and semi-structured interviews. Children (9-11y) with hemiplegia underwent five baseline assessments followed by two weeks CIMT. Six further assessments were performed during treatment and follow-up phases. The primary outcome was the Melbourne Assessment of Unilateral Upper Limb Function (MUUL). Quantitative data were analysed using standard single-subject methods and qualitative data by thematic analysis.

RESULTS: Four of the seven participants demonstrated statistically significant improvements in MUUL (3-11%, p < .05). Two participants achieved significant improvements in active range of motion but strength and tone remained largely unchanged. Qualitative interviews highlighted limitations of the restraint, importance of family involvement, and coordination of treatment with education.

CONCLUSIONS: Reduced intensity CIMT may be effective for some children in this population; however it is not suitable for all children with hemiplegia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A silver target kept under partial vacuum conditions was irradiated with focused nanosecond pulses at 1:06 mm from a Nd:YAG laser. The electron emission monitored with a Langmuir probe shows a clear twin-peak distribution. The first peak which is very sharp has only a small delay and it indicates prompt electron emission with energy as much as 60 5 eV. Also the prompt electron emission shows a temporal profile with a width that is same as that for the laser pulse whereas the second peak is broader, covers several microseconds, and represents the low-energy electrons (2 0:5 eV) associated with the laser-induced silver plasma as revealed by time-of-flight measurements. It has been found that prompt electrons ejected from the target collisionally excite and ionize ambient gas molecules. Clearly resolved rotational structure is observed in the emission spectra of ambient nitrogen molecules. Combined with time-resolved spectroscopy, the prompt electrons can be used as excitation sources for various collisional excitation–relaxation experiments. The electron density corresponding to the first peak is estimated to be of the order of 1017 cm?--3 and it is found that the density increases as a function of distance away from the target. Dependence of probe current on laser intensity shows plasma shielding at high laser intensities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The 'irrelevant sound effect' in short-term memory is commonly believed to entail a number of direct consequences for cognitive performance in the office and other workplaces (e.g. S. P. Banbury, S. Tremblay, W. J. Macken, & D. M. Jones, 2001). It may also help to identify what types of sound are most suitable as auditory warning signals. However, the conclusions drawn are based primarily upon evidence from a single task (serial recall) and a single population (young adults). This evidence is reconsidered from the standpoint of different worker populations confronted with common workplace tasks and auditory environments. Recommendations are put forward for factors to be considered when assessing the impact of auditory distraction in the workplace. Copyright (c) 2005 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Promising evidence has emerged of clinical gains using guided self-help cognitive-behavioural therapy (CBT) for child anxiety and by involving parents in treatment; however, the efficacy of guided parent-delivered CBT has not been systematically evaluated in UK primary and secondary settings. Aims To evaluate the efficacy of low-intensity guided parent-delivered CBT treatments for children with anxiety disorders. Method A total of 194 children presenting with a current anxiety disorder, whose primary carer did not meet criteria for a current anxiety disorder, were randomly allocated to full guided parent-delivered CBT (four face-to-face and four telephone sessions) or brief guided parent-delivered CBT (two face-to-face and two telephone sessions), or a wait-list control group (trial registration: ISRCTN92977593). Presence and severity of child primary anxiety disorder (Anxiety Disorders Interview Schedule for DSM-IV, child/parent versions), improvement in child presentation of anxiety (Clinical Global Impression-Improvement scale), and change in child anxiety symptoms (Spence Children’s Anxiety Scale, child/parent version and Child Anxiety Impact scale, parent version) were assessed at post-treatment and for those in the two active treatment groups, 6 months post-treatment. Results Full guided parent-delivered CBT produced superior diagnostic outcomes compared with wait-list at post-treatment, whereas brief guided parent-delivered CBT did not: at post-treatment, 25 (50%) of those in the full guided CBT group had recovered from their primary diagnosis, compared with 16 (25%) of those on the wait-list (relative risk (RR) 1.85, 95% CI 1.14-2.99); and in the brief guided CBT group, 18 participants (39%) had recovered from their primary diagnosis post-treatment (RR = 1.56, 95% CI 0.89-2.74). Level of therapist training and experience was unrelated to child outcome. Conclusions Full guided parent-delivered CBT is an effective and inexpensive first-line

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The high intensity diode laser has been studied in periodontics for the reduction of subgingival bacteria in non-surgical treatment. Our study evaluated the bacterial effect as well as changes in periodontal clinical parameters promoted by root scaling and planing associated with this wavelength. Twenty-seven patients randomly assigned in two groups underwent root scaling and planing on the tested sites, and only the experimental group received the diode laser irradiation. Among the clinical parameters studied, the clinical probing depth (CPD) and the clinical attachment level (CAL) resulted in significant enhancement in the control group when compared with the experimental group (P = 0.014 and P = 0.039, respectively). The results were similar for both groups regarding the plaque index (PI) and bleeding on probing (BP). No significant difference in the microbiological parameters was observed between the control and experimental groups. It was possible to conclude that the high power diode laser adjunct to the non-surgical periodontal treatment did not promote additional effects to the conventional periodontal treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dentin hipersensitivity (DH) is a relatively common clinical condition, especially in periodontal patients after treatment. In this study it was evaluated 28 teeth who presented dentin hypersensitivity. The teeth were subjected to clinical and radiographic exams and were divided into groups following the treatment and the time of examination after application proposed: GI: PO 3% (Potassium Oxalate-group control)/Baseline; GII: PO 3%/3 days after first session; GIII: PO 3%/6 days; GIV: PO 3%/30 days; GV: PO 3%/60 days; GVI: PO 3%/90 days; GVII: Laser (Low-level diode laser with 110 mW/cm(2))/Baseline; GVIII: Laser/7 days after first session; GIX: Laser/14 days; GX: Laser/30 days; GXI: Laser/60 days; and GXII: Laser/90 days. The groups I-VI, the teeth were subjected to 3 applications (GI-GIII) of desensitizing agent at regular intervals of seven days. The Groups VII-XI, each tooth was subjected to three applications (GVII GIX) in three different points (mesial, meddle and distal surfaces) with an interval of 72 h. The time of application in each point was of 33 s and the patients from both groups were followed up to 90 days. The nonparametric test Friedman (alpha = 0.05) was applied and the test of Mann Whitney (alpha = 0.05) was used to compare the time of examination between groups. The application of Laser was effective 6 days after first session and to PO was 30 days. It was observed that both treatments were effective for the reduction of dentin hypersensitivity, however the laser presented better effectiveness.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. To evaluate the effectiveness of the color change of hybrid light-emitting diode (LED) and low-intensity infrared diode laser devices for activating dental bleaching and to verify the occurrence of a color regression with time. Material and methods. A total of 180 specimens obtained from human premolars were immersed in a coffee solution for 15 days for darkening and then divided into eight experimental groups (n = 20 in each) as follows: G1, bleaching without light; G2, bleaching with halogen light; G3, bleaching with a blue LED (1000 mW/470 nm) and a laser device (120 mW/795 nm) simultaneously; G4, bleaching with an LED emitting blue light (1000 mW/470 nm); G5, bleaching with a blue LED (800 mW/470 nm) and a laser device (500 mW/830 nm) simultaneously; G6, bleaching with a blue LED device (800 mW); G7, bleaching with a green LED (600 mW/530 nm) and a laser device (120 mW/795 nm) simultaneously; and G8, bleaching with a green LED (600 mW). Three measurements were performed (at baseline and 14 days and 12 months after bleaching) using a Vita Easyshade spectrophotometer. The data were submitted to two-way ANOVA and a Tukey test. Results. All groups showed significantly higher Delta E values than Group G1, with the exception of Group G8. Variations in the Delta E values at 14 days were significant when compared with those obtained at baseline and after 12 months. Conclusions. Light activation of the bleaching gel provided faster and more intense bleaching than use of the bleaching gel without light activation. Combinations of low-intensity diode lasers are ineffective as a bleaching gel activator. Color regression was observed after 12 months of storage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)