977 resultados para Label-free techniques
Resumo:
The impending introduction of lead-free solder in the manufacture of electrical and electronic products has presented the electronics industry with many challenges. European manufacturers must transfer from a tin-lead process to a lead-free process by July 2006 as a result of the publication of two directives from the European Parliament. Tin-lead solders have been used for mechanical and electrical connections on printed circuit boards for over fifty years and considerable process knowledge has been accumulated. Extensive literature reviews were conducted on the topic and as a result it was found there are many implications to be considered with the introduction of lead-free solder. One particular question that requires answering is; can lead-free solder be used in existing manufacturing processes? The purpose of this research is to conduct a comparative study of a tin-lead solder and a lead-free solder in two key surface mount technology (SMT) processes. The two SMT processes in question were the stencil printing process and the reflow soldering process. Unreplicated fractional factorial experimental designs were used to carry out the studies. The quality of paste deposition in terms of height and volume were the characteristics of interest in the stencil printing process. The quality of solder joints produced in the reflow soldering experiment was assessed using x-ray and cross sectional analysis. This provided qualitative data that was then uniquely scored and weighted using a method developed during the research. Nested experimental design techniques were then used to analyse the resulting quantitative data. Predictive models were developed that allowed for the optimisation of both processes. Results from both experiments show that solder joints of comparable quality to those produced using tin-lead solder can be produced using lead-free solder in current SMT processes.
Resumo:
OBJECTIVE: The optimal coronary MR angiography sequence has yet to be determined. We sought to quantitatively and qualitatively compare four coronary MR angiography sequences. SUBJECTS AND METHODS. Free-breathing coronary MR angiography was performed in 12 patients using four imaging sequences (turbo field-echo, fast spin-echo, balanced fast field-echo, and spiral turbo field-echo). Quantitative comparisons, including signal-to-noise ratio, contrast-to-noise ratio, vessel diameter, and vessel sharpness, were performed using a semiautomated analysis tool. Accuracy for detection of hemodynamically significant disease (> 50%) was assessed in comparison with radiographic coronary angiography. RESULTS: Signal-to-noise and contrast-to-noise ratios were markedly increased using the spiral (25.7 +/- 5.7 and 15.2 +/- 3.9) and balanced fast field-echo (23.5 +/- 11.7 and 14.4 +/- 8.1) sequences compared with the turbo field-echo (12.5 +/- 2.7 and 8.3 +/- 2.6) sequence (p < 0.05). Vessel diameter was smaller with the spiral sequence (2.6 +/- 0.5 mm) than with the other techniques (turbo field-echo, 3.0 +/- 0.5 mm, p = 0.6; balanced fast field-echo, 3.1 +/- 0.5 mm, p < 0.01; fast spin-echo, 3.1 +/- 0.5 mm, p < 0.01). Vessel sharpness was highest with the balanced fast field-echo sequence (61.6% +/- 8.5% compared with turbo field-echo, 44.0% +/- 6.6%; spiral, 44.7% +/- 6.5%; fast spin-echo, 18.4% +/- 6.7%; p < 0.001). The overall accuracies of the sequences were similar (range, 74% for turbo field-echo, 79% for spiral). Scanning time for the fast spin-echo sequences was longest (10.5 +/- 0.6 min), and for the spiral acquisitions was shortest (5.2 +/- 0.3 min). CONCLUSION: Advantages in signal-to-noise and contrast-to-noise ratios, vessel sharpness, and the qualitative results appear to favor spiral and balanced fast field-echo coronary MR angiography sequences, although subjective accuracy for the detection of coronary artery disease was similar to that of other sequences.
Sensitive headspace gas chromatography analysis of free and conjugated 1-methoxy-2-propanol in urine
Resumo:
Glycol ethers still continue to be a workplace hazard due to their important use on an industrial scale. Currently, chronic occupational exposures to low levels of xenobiotics become increasingly relevant. Thus, sensitive analytical methods for detecting biomarkers of exposure are of interest in the field of occupational exposure assessment. 1-Methoxy-2-propanol (1M2P) is one of the dominant glycol ethers and the unmetabolized urinary fraction has been identified to be a good biological indicator of exposure. An existing analytical method including a solid-phase extraction and derivatization before GC/FID analysis is available but presents some disadvantages. We present here an alternative method for the determination of urinary 1M2P based on the headspace gas chromatography technique. We determined the 1M2P values by the direct headspace method for 47 samples that had previously been assayed by the solid-phase extraction and derivatization gas chromatography procedure. An inter-method comparison based on a Bland-Altman analysis showed that both techniques can be used interchangeably. The alternative method showed a tenfold lower limit of detection (0.1 mg/L) as well as good accuracy and precision which were determined by several urinary 1M2P analyses carried out on a series of urine samples obtained from a human volunteer study. The within- and between-run precisions were generally about 10%, which corresponds to the usual injection variability. We observed that the differences between the results obtained with both methods are not clinically relevant in comparison to the current biological exposure index of urinary 1M2P. Accordingly, the headspace gas chromatography technique turned out to be a more sensitive, accurate, and simple method for the determination of urinary 1M2P.[Authors]
Resumo:
PURPOSE: Respiratory motion correction remains a challenge in coronary magnetic resonance imaging (MRI) and current techniques, such as navigator gating, suffer from sub-optimal scan efficiency and ease-of-use. To overcome these limitations, an image-based self-navigation technique is proposed that uses "sub-images" and compressed sensing (CS) to obtain translational motion correction in 2D. The method was preliminarily implemented as a 2D technique and tested for feasibility for targeted coronary imaging. METHODS: During a 2D segmented radial k-space data acquisition, heavily undersampled sub-images were reconstructed from the readouts collected during each cardiac cycle. These sub-images may then be used for respiratory self-navigation. Alternatively, a CS reconstruction may be used to create these sub-images, so as to partially compensate for the heavy undersampling. Both approaches were quantitatively assessed using simulations and in vivo studies, and the resulting self-navigation strategies were then compared to conventional navigator gating. RESULTS: Sub-images reconstructed using CS showed a lower artifact level than sub-images reconstructed without CS. As a result, the final image quality was significantly better when using CS-assisted self-navigation as opposed to the non-CS approach. Moreover, while both self-navigation techniques led to a 69% scan time reduction (as compared to navigator gating), there was no significant difference in image quality between the CS-assisted self-navigation technique and conventional navigator gating, despite the significant decrease in scan time. CONCLUSIONS: CS-assisted self-navigation using 2D translational motion correction demonstrated feasibility of producing coronary MRA data with image quality comparable to that obtained with conventional navigator gating, and does so without the use of additional acquisitions or motion modeling, while still allowing for 100% scan efficiency and an improved ease-of-use. In conclusion, compressed sensing may become a critical adjunct for 2D translational motion correction in free-breathing cardiac imaging with high spatial resolution. An expansion to modern 3D approaches is now warranted.
Resumo:
OBJECTIVE Increasing evidence indicates that the Fas/Fas ligand interaction is involved in atherogenesis. We sought to analyze soluble Fas (sFas) and soluble Fas ligand (sFasL) concentrations in subjects at high cardiovascular risk and their modulation by atorvastatin treatment. METHODS AND RESULTS ACTFAST was a 12-week, prospective, multicenter, open-label trial which enrolled subjects (statin-free or statin-treated at baseline) with coronary heart disease (CHD), CHD-equivalent, or 10-year CHD risk > 20%. Subjects with LDL-C between 100 to 220 mg/dL (2.6 to 5.7 mmol/L) and triglycerides < or = 600 mg/dL (6.8 mmol/L) were assigned to a starting dose of atorvastatin (10 to 80 mg/d) based on LDL-C at screening. Of the 2117 subjects enrolled in ACTFAST, AIM sub-study included the 1078 statin-free patients. At study end, 85% of these subjects reached LDL-C target. Mean sFas levels were increased and sFasL were reduced in subjects at high cardiovascular risk compared with healthy subjects. Atorvastatin reduced sFas in the whole population as well as in patients with metabolic syndrome or diabetes. Minimal changes were observed in sFasL. CONCLUSIONS sFas concentrations are increased and sFasL are decreased in subjects at high cardiovascular risk, suggesting that these proteins may be novel markers of vascular injury. Atorvastatin reduces sFas, indicating that short-term treatment with atorvastatin exhibits antiinflammatory effects in these subjects.
Resumo:
In this project a research both in finding predictors via clustering techniques and in reviewing the Data Mining free software is achieved. The research is based in a case of study, from where additionally to the KDD free software used by the scientific community; a new free tool for pre-processing the data is presented. The predictors are intended for the e-learning domain as the data from where these predictors have to be inferred are student qualifications from different e-learning environments. Through our case of study not only clustering algorithms are tested but also additional goals are proposed.
Resumo:
BACKGROUND Dermatologic surgeons routinely harvest pedicled flaps at distance with an axial or random pattern to repair facial defects. These types of skin flaps are time-consuming and have high economic, social and personal costs. These drawbacks could be avoided with the introduction of a single-step transfer of free flaps to the recipient site, with microvascular anastomosis. OBJECTIVE To demonstrate that better results are obtained with myocutaneous or fasciocutaneous free flaps and which one is more suitable in surgical dermatology. MATERIAL AND METHODS We selected two patients of opposite sexes and similar ages who had undergone Mohs surgery to remove recurrent malignant tumors that were located in the upper cheek bordering the zygomatic zone. The woman was treated with a fasciocutaneous radial free flap and the man with a rectus abdominis free flap. RESULTS Both patients had excellent immediate postoperative outcomes. Complications observed in the male patient were related to a previous pulmonary alteration. The fasciocutaneous radial free flap reconstruction was easier to perform than the rectus abdominis free flap; nevertheless, the radial free flap is very thin and, although the palmaris longus tendon is used, it does not yield enough volume, requiring later use of implants. In contrast, the rectus abdominis free flap transfers a wide flap with enough fat tissue to expand in the future. As for the cosmetic results regarding the donor site, the rectus abdominis free flap produces better-looking scars, since secondary defects of the palmar surface cannot be directly closed and usually require grafting - a situation that some patients do not accept. CONCLUSIONS In surgical dermatology, each case, once the tumor has been extirpated, requires its own reconstructive technique. The radial free flap is suitable for thin patients who are willing to cover their arm with a shirt. The rectus abdominis free flap is best suited for obese patients with deep and voluminous defects, although it is necessary to dislocate the navel from its original position.
Resumo:
Gluten content from barley, rye, wheat and in certain oat varieties, must be avoid in individuals with celiac disease. In most of the Western countries, the level of gluten content in food to be considered as gluten-free products is below 20 parts per million measured by ELISA based on specific anti-gluten peptide antibody. However, in beverages or food suffering complex hydrolytic processes as beers, the relative proportion of reactive peptides for celiac patients and the analytical techniques may differ, because of the diversity of the resulting peptide populations after fermentations. A beer below 20 parts per million of gluten but yet detectable levels of gluten peptides by anti-gliadin 33-mer antibodies (G12 and A1) was analyzed. We identified and characterized the relevant peptides for either antibody recognition or immunoactivity in celiac patients. The beer was fractionated by HPLC. The relative reactivity of the different HPLC fractions to the G12/A1 antibodies correlated to the reactivity of peripheral blood mononuclear cells isolated from 14 celiac individuals. Peptides from representative fractions classified according to the relative reactivity to G12/A1 antibodies were identified by mass spectrometry. The beer peptides containing sequences with similarity to those of previously described G12 and A1 epitopes were synthesized and confirmed significant reactivity for the antibodies. The most reactive peptides for G12/A1 also confirmed the highest immunogenicity by peripheral blood mononuclear cell activation and interferon γ production from celiac patients. We concluded that preparative HPLC combined with anti-gliadin 33-mer G12/A1 antibodies were very sensitive and specific methods to analyze the relevant immunogenic peptides in hydrolyzed gluten.
Resumo:
Tumoral necrosis factor α plays a central role in both the inflammatory response and that of the immune system. Thus, its blockade with the so-called anti-TNF agents (infliximab, etanercept, adalimumab, certolizumab pegol, and golimumab) has turned into the most important tool in the management of a variety of disorders, such as rheumatoid arthritis, spondyloarthropatties, inflammatory bowel disease, and psoriasis. Nonetheless, theoretically, some other autoimmune disorders may benefit from these agents. Our aim is to review these off-label uses of anti-TNF blockers in three common conditions: Behçet's disease, sarcoidosis, and noninfectious uveitis. Due to the insufficient number of adequate clinical trials and consequently to their lower prevalence compared to other immune disorders, this review is mainly based on case reports and case series.
Resumo:
OBJECTIVE to evaluate the prescription profile and to assess the off-label and unlicensed uses of medicines among non-hospitalised pediatric patients. DESIGN cross-sectional study. SETTING pediatric units in two urban health centers and general emergency room (Hospital Materno-Infantil, Málaga). MAIN MEASUREMENTS sociodemographics variables, reasons for consultation and information about therapeutic medications. The classification of prescriptions was established according to information requirements contained in the Summary of Products Characteristics (SPC). RESULTS A total of 388 children were included (a subsample of 105 treated in the emergency room). Four hundred sixty-two prescriptions (involving 74 different active ingredients) were evaluated. Each infant received and average of 1,7 drugs (95% CI: 1,6-1,9). The most prescribed medicines were ibuprofen, paracetamol, amoxicillin-clavulanate and budesonide. The therapeutic group with the greatest variety of drugs was the respiratory group. 27,4% (95% CI: 23,5-31) of prescriptions were off-label and the main cause was different age (60%; 95% CI: 54,1-63), followed by different dose (21,5%; 95% CI: 18-25), different indication (12%; 95% CI: 9,2-15) and different route of administration (7%; 95% CI: 5,4-10). CONCLUSIONS The rate of off-label uses presents intermediate figures. Around one third of the paediatric outpatients in our sample are exposed to at least one off-label or unlicensed prescription. We should, however, point out that such usage is based on scant official, quality information, although it is not necessarily incorrect. Evidence-based medicine should be encouraged to improve drug therapy in children, as well as following the rules on drugs in special situations.
Resumo:
BACKGROUND It is unknown if lack of polymer can provoke a different edge response in drug-eluting stents. The aim of this study was to compare edge vascular response between polymer-free paclitaxel-eluting stent (PF-PES) and polymer-based paclitaxel-eluting stents (PB-PES). METHODS AND RESULTS: A total of 165 eligible patients undergoing percutaneous coronary intervention were prospectively randomized 1:1 to receive either PF-PES or PB-PES. Those patients with paired intravascular ultrasound (IVUS) after procedure and at 9-month follow-up were included in this analysis.Seventy-six patients with 84 lesions, divided into PB-PES (38 patients, 41 lesions) and PF-PES groups (38 patients, 43 lesions) had paired post-procedure and 9-month follow-up IVUS and were therefore included in this substudy. There was a significant lumen decrease at the proximal edge of PF-PES (from 9.02±3.06 mm(2)to 8.47±3.05 mm(2); P=0.040), and a significant plaque increase at the distal edges of PF-PES (from 4.39±2.73 mm(2)to 4.78±2.63 mm(2); P=0.004). At the distal edge there was a significant plaque increase in the PF-PES compared to PB-PES (+8.0% vs. -0.6%, respectively; P=0.015) with subsequent lumen reduction (-5.2% vs. +6.0%, respectively; P=0.024). CONCLUSIONS PF-PES had significant plaque increase and lumen reduction at the distal edge as compared to PB-PES, probably due to difference in polymer-based drug-release kinetics between the 2 platforms.
Resumo:
This paper describes a systematic research about free software solutions and techniques for art imagery computer recognition problem.
Resumo:
Successful expansion of haematopoietic cells in ex vivo cultures will have important applications in transplantation, gene therapy, immunotherapy and potentially also in the production of non-haematopoietic cell types. Haematopoietic stem cells (HSC), with their capacity to both self-renew and differentiate into all blood lineages, represent the ideal target for expansion protocols. However, human HSC are rare, poorly characterized phenotypically and genotypically, and difficult to test functionally. Defining optimal culture parameters for ex vivo expansion has been a major challenge. We devised a simple and reproducible stroma-free liquid culture system enabling long-term expansion of putative haematopoietic progenitors contained within frozen human fetal liver (FL) crude cell suspensions. Starting from a small number of total nucleated cells, a massive haematopoietic cell expansion, reaching > 1013-fold the input cell number after approximately 300 d of culture, was consistently achieved. Cells with a primitive phenotype were present throughout the culture and also underwent a continuous expansion. Moreover, the capacity for multilineage lymphomyeloid differentiation, as well as the recloning capacity of primitive myeloid progenitors, was maintained in culture. With its better proliferative potential as compared with adult sources, FL represents a promising alternative source of HSC and the culture system described here should be useful for clinical applications.
Resumo:
Concrete curing is closely related to cement hydration, microstructure development, and concrete performance. Application of a liquid membrane-forming curing compound is among the most widely used curing methods for concrete pavements and bridge decks. Curing compounds are economical, easy to apply, and maintenance free. However, limited research has been done to investigate the effectiveness of different curing compounds and their application technologies. No reliable standard testing method is available to evaluate the effectiveness of curing, especially of the field concrete curing. The present research investigates the effects of curing compound materials and application technologies on concrete properties, especially on the properties of surface concrete. This report presents a literature review of curing technology, with an emphasis on curing compounds, and the experimental results from the first part of this research—lab investigation. In the lab investigation, three curing compounds were selected and applied to mortar specimens at three different times after casting. Two application methods, single- and double-layer applications, were employed. Moisture content, conductivity, sorptivity, and degree of hydration were measured at different depths of the specimens. Flexural and compressive strength of the specimens were also tested. Statistical analysis was conducted to examine the relationships between these material properties. The research results indicate that application of a curing compound significantly increased moisture content and degree of cement hydration and reduced sorptivity of the near-surface-area concrete. For given concrete materials and mix proportions, optimal application time of curing compounds depended primarily upon the weather condition. If a sufficient amount of a high-efficiency-index curing compound was uniformly applied, no double-layer application was necessary. Among all test methods applied, the sorptivity test is the most sensitive one to provide good indication for the subtle changes in microstructure of the near-surface-area concrete caused by different curing materials and application methods. Sorptivity measurement has a close relation with moisture content and degree of hydration. The research results have established a baseline for and provided insight into the further development of testing procedures for evaluation of curing compounds in field. Recommendations are provided for further field study.
Resumo:
For free-breathing, high-resolution, three-dimensional coronary magnetic resonance angiography (MRA), the use of intravascular contrast agents may be helpful for contrast enhancement between coronary blood and myocardium. In six patients, 0.1 mmol/kg of the intravascular contrast agent MS-325/AngioMARK was given intravenously followed by double-oblique, free-breathing, three-dimensional inversion-recovery coronary MRA with real-time navigator gating and motion correction. Contrast-enhanced, three-dimensional coronary MRA images were compared with images obtained with a T2 prepulse (T2Prep) without exogenous contrast. The contrast-enhanced images demonstrated a 69% improvement in the contrast-to-noise ratio (6.6 +/- 1.1 vs. 11.1 +/- 2.5; P < 0.01) compared with the T2Prep approach. By using the intravascular agent, extensive portions (> 80 mm) of the native left and right coronary system could be displayed consistently with sub-millimeter in-plane resolution. The intravascular contrast agent, MS-325/AngioMARK, leads to a considerable enhancement of the blood/muscle contrast for coronary MRA compared with T2Prep techniques. The clinical value of the agent remains to be defined in a larger patient series. J. Magn. Reson. Imaging 1999;10:790-799.