982 resultados para LOW-ENERGY


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Within general characteristics of low-energy few-body systems, we revise some well-known correlations found in nuclear physics, and the properties of low-mass halo nuclei in a three-body neutron-neutron-core model. In this context, near the critical conditions for the occurrence of an Efimov state, we report some results obtained for the neutron- 19C elastic scattering. © 2010 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using a recent shape-independent approximation for the 3S1-3D1 mixing parameter, theoretical prevision for the low-energy mixing parameters is made. The present prevision is consistent with the deuteron binding energy, its asymptotic D-state to S-state ratio, ηd, the triplet-scattering length, and the meson exchange tail of the tensor nucleon-nucleon potential. The theoretical prevision up to an incident laboratory energy of 25 MeV is consistent with the recent multi-energy determination of mixing parameters, but is much higher than many single-energy determinations of the same. The low single-energy values of the mixing parameter could be reproduced by meson-theoretical potentials only with a substantially reduced ηd. © 1994 The American Physical Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report cross sections for elastic electron scattering by gas phase glycine (neutral form), obtained with the Schwinger multichannel method. The present results are the first obtained with a new implementation that combines parallelization with OpenMP directives and pseudopotentials. The position of the well known pi* shape resonance ranged from 2.3 eV to 2.8 eV depending on the polarization model and conformer. For the most stable isomer, the present result (2.4 eV) is in fair agreement with electron transmission spectroscopy assignments (1.93 +/- 0.05 eV) and available calculations. Our results also point out a shape resonance around 9.5 eV in the A' symmetry that would be weakly coupled to vibrations of the hydroxyl group. Since electron attachment to a broad and lower lying sigma* orbital located on the OH bond has been suggested the underlying mechanism leading to dissociative electron attachment at low energies, we sought for a shape resonance around similar to 4 eV. Though we obtained cross sections with the target molecule at the equilibrium geometry and with stretched OH bond lengths, least-squares fits to the calculated eigenphase sums did not point out signatures of this anion state (though, in principle, it could be hidden in the large background). The low energy (similar to 1 eV) integral cross section strongly scales as the bond length is stretched, and this could indicate a virtual state pole, since dipole supported bound states are not expected at the geometries addressed here. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.3687345]

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Optical transition radiation (OTR) plays an important role in beam diagnostics for high energy particle accelerators. Its linear intensity with beam current is a great advantage as compared to fluorescent screens, which are subject to saturation. Moreover, the measurement of the angular distribution of the emitted radiation enables the determination of many beam parameters in a single observation point. However, few works deals with the application of OTR to monitor low energy beams. In this work we describe the design of an OTR based beam monitor used to measure the transverse beam charge distribution of the 1.9-MeV electron beam of the linac injector of the IFUSP microtron using a standard vision machine camera. The average beam current in pulsed operation mode is of the order of tens of nano-Amps. Low energy and low beam current make OTR observation difficult. To improve sensitivity, the beam incidence angle on the target was chosen to maximize the photon flux in the camera field-of-view. Measurements that assess OTR observation (linearity with beam current, polarization, and spectrum shape) are presented, as well as a typical 1.9-MeV electron beam charge distribution obtained from OTR. Some aspects of emittance measurement using this device are also discussed. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4748519]

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The extrapolation chamber is a parallel-plate ionization chamber that allows variation of its air-cavity volume. In this work, an experimental study and MCNP-4C Monte Carlo code simulations of an ionization chamber designed and constructed at the Calibration Laboratory at IFEN to be used as a secondary dosimetry standard for low-energy X-rays are reported. The results obtained were within the international recommendations, and the simulations showed that the components of the extrapolation chamber may influence its response up to 11.0%. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the framework of gauged flavour symmetries, new fermions in parity symmetric representations of the standard model are generically needed for the compensation of mixed anomalies. The key point is that their masses are also protected by flavour symmetries and some of them are expected to lie way below the flavour symmetry breaking scale(s), which has to occur many orders of magnitude above the electroweak scale to be compatible with the available data from flavour changing neutral currents and CP violation experiments. We argue that, actually, some of these fermions would plausibly get masses within the LHC range. If they are taken to be heavy quarks and leptons, in (bi)-fundamental representations of the standard model symmetries, their mixings with the light ones are strongly constrained to be very small by electroweak precision data. The alternative chosen here is to exactly forbid such mixings by breaking of flavour symmetries into an exact discrete symmetry, the so-called proton-hexality, primarily suggested to avoid proton decay. As a consequence of the large value needed for the flavour breaking scale, those heavy particles are long-lived and rather appropriate for the current and future searches at the LHC for quasi-stable hadrons and leptons. In fact, the LHC experiments have already started to look for them.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reactions initiated by collisions with low-energy secondary electrons has been found to be the prominent mechanism toward the radiation damage on living tissues through DNA strand breaks. Now it is widely accepted that during the interaction with these secondary species the selective breaking of chemical bonds is triggered by dissociative electron attachment (DEA), that is, the capture of the incident electron and the formation of temporary negative ion states [1,2,3]. One of the approaches largely used toward a deeper understanding of the radiation damage to DNA is through modeling of DEA with its basic constituents (nucleotide bases, sugar and other subunits). We have tried to simplify this approach and attempt to make it comprehensible at a more fundamental level by looking at even simple molecules. Studies involving organic systems such as carboxylic acids, alcohols and simple ¯ve-membered heterocyclic compounds are taken as starting points for these understanding. In the present study we investigate the role played by elastic scattering and electronic excitation of molecules on electron-driven chemical processes. Special attention is focused on the analysis of the in°uence of polarization and multichannel coupling e®ects on the magnitude of elastic and electronically inelastic cross-sections. Our aim is also to investigate the existence of resonances in the elastic and electronically inelastic channels as well as to characterize them with respect to its type (shape, core-excited or Feshbach), symmetry and position. The relevance of these issues is evaluated within the context of possible applications for the modeling of discharge environments and implications in the understanding of mutagenic rupture of DNA chains. The scattering calculations were carried out with the Schwinger multichannel method (SMC) [4] and its implementation with pseudopotentials (SMCPP) [5] at di®erent levels of approximation for impact energies ranging from 0.5 eV to 30 eV. References [1] B. Boudai®a, P. Cloutier, D. Hunting, M. A. Huels and L. Sanche, Science 287, 1658 (2000). [2] X. Pan, P. Cloutier, D. Hunting and L. Sanche, Phys. Rev. Lett. 90, 208102 (2003). [3] F. Martin, P. D. Burrow, Z. Cai, P. Cloutier, D. Hunting and L. Sanche, Phys. Rev. Lett. 93, 068101 (2004). [4] K. Takatsuka and V. McKoy, Phys. Rev. A 24, 2437 (1981); ibid. Phys. Rev. A 30, 1734 (1984). [5] M. H. F. Bettega, L. G. Ferreira and M. A. P. Lima, Phys. Rev. A 47, 1111 (1993).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present work describes the development of a new body-counter system based on HPGe detectors and installed at IVM of KIT. The goal, achieved, was the improvement of the ability to detect internal contaminations in the human body, especially the ones concerning low-energy emitters and multiple nuclides. The development of the system started with the characterisation of detectors purchased for this specific task, with the optimisation of the different desired measurement configurations following and ending with the installation and check of the results. A new software has been developed to handle the new detectors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La tesi nasce da un'attività di ricerca approfondita su alcune tecnologie innovative e all'avanguardia nell'ambito del mobile computing e dell'Internet of Things. Tra queste il focus principale è orientato allo studio del Bluetooth Low Energy, nuova specifica di Bluetooth caratterizzata principalmente da un consumo di energia assai ridotto. In particolare, si è approfondito il suo funzionamento nel caso dei beacon, piccoli dispositivi che permettono una localizzazione mediante l'invio di un segnale BLE. Inoltre è stata analizzata la possibilità di interazione con Android, poiché oggigiorno non si può evitare di pensare a come queste tecnologie possano interfacciarsi con il mondo degli smartphone e dei tablet. Come conseguenza di tale attività di ricerca è stato analizzato un caso di studio che permettesse di applicare le tecnologie studiate e la loro interazione. Si è pensato quindi a un piccolo sistema distribuito per schermi adattativi (capaci di modificare i contenuti visualizzati in relazione ad eventi esterni) affinché ogni schermo mostrasse dinamicamente l'orario delle lezioni di ciascuno studente all'avvicinarsi di quest'ultimo, e solo per il tempo di permanenza nei pressi dello schermo. Si è quindi progettato e sviluppato un prototipo, e infine durante il testing si sono potute verificare le attuali potenzialità di queste tecnologie e trarre conclusioni sulla possibilità della loro futura diffusione e di impiego in contesti differenti.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lo scopo dell’elaborato di tesi è la progettazione e lo sviluppo di un’applicazione per il modulo Bluetooth Low Energy (BLE) Texas Instrument CC2650 in grado di leggere le informazioni da un sensore analogico, tramite un Analog-Digital- Converter (ADC), e di scambiare i dati con uno smartphone Android in tempo reale. L’interfaccia realizzata deve essere universale, ovvero dovrà essere compatibile con sensori di diverso tipo, facilmente estensibile per l’aggiunta di un numero maggiore di periferiche di lettura e utilizzabile con un ampio numero di dispositivi.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In questo elaborato è stato effettuato uno studio di soluzioni tecnologiche per eseguire una localizzazione di prossimità in ambienti indoor tramite la percezione di segnali Bluetooth Low Energy. Il sistema analizzato e sperimentato è composto da un dispositivo in ricezione che effettua una stima della distanza che intercorre con il trasmettitore, tramite la valutazione della potenza del segnale ricevuto. A causa della propagazione indoor, tale stima risulta poco accurata in termini di ranging in quanto vengono a generarsi delle fluttuazioni istantanee del segnale ricevuto dovute a fenomeni di multipath. L’obiettivo di questo progetto è stato quello di mitigare queste oscillazioni sfruttando due trasmettitori al posto di uno, effettuando quindi in ricezione opportune combinazioni fra i segnali ricevuti (Diversity Combining Techniques).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In questo elaborato sono stati confrontati i moduli bluetooth WT11, BLE113 , BT121 rispetto alle loro caratteristiche di banda, consumo, range e utilizzabilita in un contesto applicativo stringente come quello degli utilizzi biomeccanici. Si sono prima elencati i settori di riferimento, per poi descrivere il contesto applicativo in ambito medico e sportivo. Il confronto finale ha tenuto conto delle modalita di comunicazione bluetooth classic e bluetooth low energy, cercando di motivare quale modulo risulti migliore per questo particolare e innovativo contesto.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electron Monte Carlo (eMC) dose calculation algorithm in Eclipse (Varian Medical Systems) is based on the macro MC method and is able to predict dose distributions for high energy electron beams with high accuracy. However, there are limitations for low energy electron beams. This work aims to improve the accuracy of the dose calculation using eMC for 4 and 6 MeV electron beams of Varian linear accelerators. Improvements implemented into the eMC include (1) improved determination of the initial electron energy spectrum by increased resolution of mono-energetic depth dose curves used during beam configuration; (2) inclusion of all the scrapers of the applicator in the beam model; (3) reduction of the maximum size of the sphere to be selected within the macro MC transport when the energy of the incident electron is below certain thresholds. The impact of these changes in eMC is investigated by comparing calculated dose distributions for 4 and 6 MeV electron beams at source to surface distance (SSD) of 100 and 110 cm with applicators ranging from 6 x 6 to 25 x 25 cm(2) of a Varian Clinac 2300C/D with the corresponding measurements. Dose differences between calculated and measured absolute depth dose curves are reduced from 6% to less than 1.5% for both energies and all applicators considered at SSD of 100 cm. Using the original eMC implementation, absolute dose profiles at depths of 1 cm, d(max) and R50 in water lead to dose differences of up to 8% for applicators larger than 15 x 15 cm(2) at SSD 100 cm. Those differences are now reduced to less than 2% for all dose profiles investigated when the improved version of eMC is used. At SSD of 110 cm the dose difference for the original eMC version is even more pronounced and can be larger than 10%. Those differences are reduced to within 2% or 2 mm with the improved version of eMC. In this work several enhancements were made in the eMC algorithm leading to significant improvements in the accuracy of the dose calculation for 4 and 6 MeV electron beams of Varian linear accelerators.