983 resultados para LASER BEAM MACHINING


Relevância:

80.00% 80.00%

Publicador:

Resumo:

he phenomenon of single beam mirage effect, otherwise known as photothermal deflection (PTD) effect using a He–Ne laser beam has been employed to detect phase transitions in some liquid crystals. It has been observed that anomalous changes in amplitude occur in the PTD signal level near the transition temperature. The experimental details and the results of measurements made in liquid crystals E8, M21 and M24 are given in this paper.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Thermal lensing effect was studied in aqueous solutions of rhodamine B using 532 nm, 9 ns pulses from a Nd:YAG laser. A low intensity He-Ne laser beam was used for probing the thermal lens. Results obtained show that it is appropriate to use this technique for studying nonlinear absorption processes like two photon absorption or excited state absorption and for analyzing dimerization equilibria.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Non-destructive testing d multilayer dielectric coatings (SiO2/TiO2 structure) has been carried out using the photoacoustic technique. This technique makes use d a 10 mW He-Ne laser, a photoacoustic cell and a lock-in amplifier. The chopped He-Ne laser beam is allowed to fall on the sample placed in a photoacoustic cell. The acoustic signals thus generated are detected using a microphone and the resulting output is processed by a lock-in amplifier. The amplitude and phase of the signals were measured as a function of the chopping frequency. Striking step-like variations are observed in me phase against frequency plot which dearly reveals the different layers present in the multilayer structure.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Experimental method for measuring photoacoustic(PA) signals generated by a pulsed laser beam in liquids is described. The pulsed PA technique is found to be a convenient and accurate method for determination of quantum yield in fluorescent dye solutions. Concentration dependence of quantum yield of rhodamine 6G in water is studied using the above method. The results indicate that the quantum yield decreases with increase in concentration in the quenching region in agreement with the existing reports based on radiometric measurements.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The phenomenon of mirage effect suffered by a He-Ne laser beam has been utilized to detect phase transitions in solids. It has been observed that anomalous fluctuations of large amplitude occur in the signal level near the transition temperature. The mean square value of the fluctuation is found to exhibit a well-defined peak at this point. Results of measurements made in the case of crystals of TGS ((NH2CH2COOH)3.H2SO4) and a ceramic sample (BaTiO3) are given to illustrate this technique.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Variations in the decay times of the characteristic green emissions at 522.7, 551.3, 549.6, 547.6, 542.2, 540.2, 535.9 and 533.5nm from CaF2 :H03+ with concentration are studied at RT and LNT. A pulsed N2 laser beam of power density 1.5 MW cm-2 is used for the excitation. Temperature dependent concentration quenching of the decay times are observed for all the emission bands. But an increase in the decay time due to the reabsorption process is also observed for a few of the above bands.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Raman spectra of the KTP single crystal are recorded in electric fields (dc and ac) applied along the polar axis c. Spectra with the laser beam focused near the cathode end, anode end and the centre of the crystal are recorded. The cathode end of the crystal develops a spot ‘grey track’ where the laser beam is focused after a lapse of 5 h from the application of a dc electric field of 38 V/cm. The spectra recorded at the cathode end after the application of field show variations in intensity of bands. A new band appears at 177 cm21. Changes in band intensities are explained on the basis of changes in polarizability of the crystal due to the movement of K1 ions along the polar axis. K1 ions accumulate at the cathode end, where the ‘Grey track’ formation occurs. The intensity enhancement observed for almost all bands in the ac field is attributed to the improvement of crystalline quality.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Scanning Probe Microscopy (SPM) has become of fundamental importance for research in area of micro and nano-technology. The continuous progress in these fields requires ultra sensitive measurements at high speed. The imaging speed limitation of the conventional Tapping Mode SPM is due to the actuation time constant of piezotube feedback loop that keeps the tapping amplitude constant. In order to avoid this limit a deflection sensor and an actuator have to be integrated into the cantilever. In this work has been demonstrated the possibility of realisation of piezoresistive cantilever with an embedded actuator. Piezoresistive detection provides a good alternative to the usual optical laser beam deflection technique. In frames of this thesis has been investigated and modelled the piezoresistive effect in bulk silicon (3D case) for both n- and p-type silicon. Moving towards ultra-sensitive measurements it is necessary to realize ultra-thin piezoresistors, which are well localized to the surface, where the stress magnitude is maximal. New physical effects such as quantum confinement which arise due to the scaling of the piezoresistor thickness was taken into account in order to model the piezoresistive effect and its modification in case of ultra-thin piezoresistor (2D case). The two-dimension character of the electron gas in n-type piezoresistors lead up to decreasing of the piezoresistive coefficients with increasing the degree of electron localisation. Moreover for p-type piezoresistors the predicted values of the piezoresistive coefficients are higher in case of localised holes. Additionally, to the integration of the piezoresistive sensor, actuator integrated into the cantilever is considered as fundamental for realisation of fast SPM imaging. Actuation of the beam is achieved thermally by relying on differences in the coefficients of thermal expansion between aluminum and silicon. In addition the aluminum layer forms the heating micro-resistor, which is able to accept heating impulses with frequency up to one megahertz. Such direct oscillating thermally driven bimorph actuator was studied also with respect to the bimorph actuator efficiency. Higher eigenmodes of the cantilever are used in order to increase the operating frequencies. As a result the scanning speed has been increased due to the decreasing of the actuation time constant. The fundamental limits to force sensitivity that are imposed by piezoresistive deflection sensing technique have been discussed. For imaging in ambient conditions the force sensitivity is limited by the thermo-mechanical cantilever noise. Additional noise sources, connected with the piezoresistive detection are negligible.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Techniques for the coherent generation and detection of electromagnetic radiation in the far infrared, or terahertz, region of the electromagnetic spectrum have recently developed rapidly and may soon be applied for in vivo medical imaging. Both continuous wave and pulsed imaging systems are under development, with terahertz pulsed imaging being the more common method. Typically a pump and probe technique is used, with picosecond pulses of terahertz radiation generated from femtosecond infrared laser pulses, using an antenna or nonlinear crystal. After interaction with the subject either by transmission or reflection, coherent detection is achieved when the terahertz beam is combined with the probe laser beam. Raster scanning of the subject leads to an image data set comprising a time series representing the pulse at each pixel. A set of parametric images may be calculated, mapping the values of various parameters calculated from the shape of the pulses. A safety analysis has been performed, based on current guidelines for skin exposure to radiation of wavelengths 2.6 µm–20 mm (15 GHz–115 THz), to determine the maximum permissible exposure (MPE) for such a terahertz imaging system. The international guidelines for this range of wavelengths are drawn from two U.S. standards documents. The method for this analysis was taken from the American National Standard for the Safe Use of Lasers (ANSI Z136.1), and to ensure a conservative analysis, parameters were drawn from both this standard and from the IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields (C95.1). The calculated maximum permissible average beam power was 3 mW, indicating that typical terahertz imaging systems are safe according to the current guidelines. Further developments may however result in systems that will exceed the calculated limit. Furthermore, the published MPEs for pulsed exposures are based on measurements at shorter wavelengths and with pulses of longer duration than those used in terahertz pulsed imaging systems, so the results should be treated with caution.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We propose a new satellite mission to deliver high quality measurements of upper air water vapour. The concept centres around a LiDAR in limb sounding by occultation geometry, designed to operate as a very long path system for differential absorption measurements. We present a preliminary performance analysis with a system sized to send 75 mJ pulses at 25 Hz at four wavelengths close to 935 nm, to up to 5 microsatellites in a counter-rotating orbit, carrying retroreflectors characterized by a reflected beam divergence of roughly twice the emitted laser beam divergence of 15 µrad. This provides water vapour profiles with a vertical sampling of 110 m; preliminary calculations suggest that the system could detect concentrations of less than 5 ppm. A secondary payload of a fairly conventional medium resolution multispectral radiometer allows wide-swath cloud and aerosol imaging. The total weight and power of the system are estimated at 3 tons and 2,700 W respectively. This novel concept presents significant challenges, including the performance of the lasers in space, the tracking between the main spacecraft and the retroreflectors, the refractive effects of turbulence, and the design of the telescopes to achieve a high signal-to-noise ratio for the high precision measurements. The mission concept was conceived at the Alpbach Summer School 2010.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Z-scan technique is employed to obtain the nonlinear refractive index (n (2)) of the Ca(4)REO(BO(3))(3) (RECOB, where RE = Gd and La) single crystals using 30 fs laser pulses centered at 780 nm for the two orthogonal orientations determined by the optical axes (X and Z) relative to the direction of propagation of the laser beam (k//Y// crystallographic b-axis). The large values of n (2) indicate that both GdCOB and LaCOB are potential hosts for Yb:RECOB lasers operating in the Kerr-lens mode locking (KLM) regime.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cooperative spontaneous emission of a single photon from a cloud of N atoms modifies substantially the radiation pressure exerted by a far-detuned laser beam exciting the atoms. On one hand, the force induced by photon absorption depends on the collective decay rate of the excited atomic state. On the other hand, directional spontaneous emission counteracts the recoil induced by the absorption. We derive an analytical expression for the radiation pressure in steady-state. For a smooth extended atomic distribution we show that the radiation pressure depends on the atom number via cooperative scattering and that, for certain atom numbers, it can be suppressed or enhanced. Cooperative scattering of light by extended atomic clouds can become important in the presence of quasi-resonant light and could be addressed in many cold atoms experiments.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Several experiments (time-resolved Z-scan experiments based on pulsed and CW pump lasers, time-resolved divergence diagnostics) have been performed to examine and clarify the question of the converging or diverging population lensing effect occurring in a Cr(3+):Al(2)O(3) ruby laser. The dynamics of the laser far-field divergence of such a laser indeed indicated initially a diverging effect while Z-scan measurements conclude to a converging one. The origin of this discrepancy is thus analysed and elucidated here by introducing the general concept of correlation collapse between the centre and the wings of a laser beam having some clipping. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Gold nanoparticles (AuNP) incorporated into hydrotalcite (HT), provide an interesting type of pigment in which temperature can modulate the plasmon resonance and the aggregation phenomenon. As inferred from microscopy techniques, the preferential binding sites are located at the border of the HT external basal surface, leading to aggregates of gold nanoparticles displaying characteristic plasmon resonance and interference bands around 520 and 700 nm, respectively. The thermally induced color changes in the HT-supported gold material arise from the competition between of nanoparticles aggregation and fusion processes, as characterized by TEM and STM. A laser beam can also induce such changes, allowing the writing of optical information on this type of material.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

It was aimed to evaluate the spectrum and uniformity of droplets in function of sprayers, spraying volumes and rates of chemical insecticide on the mortality of Pseudoplusia includens in laboratory. The work was carried out at UNESP, Jaboticabal, SP, Brazil. The following treatments were applied over the caterpillars: two equipments (atomizer and hydraulic nozzle); two spray volumes (17 and 50 L ha(-1) for the atomizer and 50 and 100 L ha(-1) for the hydraulic nozzle); and two dosages of the insecticide endosulfan (0.5 and 1.0 L pc ha(-1)), in fully randomized plots, in a factorial scheme 2x2x2 and 1 untreated check. The caterpillars mortality was evaluated until the 6(th) day after the application of treatments. The spectrum of the droplets was evaluated in a particle size analyzer in real time determining the diameter and spectrum of droplets sprayed through the laser beam of the analyser. It was verified that the spray volume can be reduced by 17 L ha(-1) without losses on the P. includens control. The doses of 0.5 L pc ha(-1) (recommended for Anticarsia gemmatalis) did not satisfactorily control the caterpillar soybean looper. The atomizer produces droplets of higher uniformity (SPAN: 0.52) and lower percentage of droplets susceptible to drift (3.3%) compared to hydraulic nozzle (SPAN: 1.34 e % droplets <= 100 mu m: 15.2).