713 resultados para Interphase transformer
Resumo:
This paper presents the design of a dual Z-source inverter that can be used with either a single dc source or two isolated dc sources. Unlike traditional inverters, the integration of a properly designed Z-source network and semiconductor switches to the proposed dual inverter allows buck-boost power conversion to be performed over a wide modulation range with three-level output waveforms generated. The connection of an additional transformer to the inverter ac output also allows all generic wye- or delta-connected loads with three-wire or four-wire configuration to be supplied by the inverter. Modulation-wise, the dual inverter can be controlled using a carefully designed carrier-based pulse-width modulation (PWM) scheme that always will ensure balanced voltage boosting of the Z-source network, while simultaneously achieving reduced common-mode switching. Because of the omission of dead-time delays in the dual inverter PWM scheme, its switched common-mode voltage can be completely eliminated, unlike in traditional inverters where narrow common-mode spikes are still generated. Under semiconductor failure conditions, the presented PWM schemes can easily be modified to allow the inverter to operate without interruption and for cases where two isolated sources are used, zero common-mode voltage can still be ensured. These theoretical findings together with the inverter practicality have been confirmed both in simulations using PSIM with Matlab/Simulink coupler and experimentally using a laboratory implemented inverter prototype.
Resumo:
This paper presents the design of a dual Z-source inverter that can be used with either a single dc source or two isolated dc sources. Unlike traditional inverters, the integration of a properly designed Z-source network and semiconductor switches to the proposed dual inverter allows buck-boost power conversion to be performed over a wide modulation range, with three-level output waveforms generated. The connection of an additional transformer to the inverter ac output also allows all generic wye-or delta-connected loads with three-wire or four-wire configuration to be supplied by the inverter. Modulationwise, the dual inverter can be controlled using a carefully designed carrier-based pulsewidth-modulation (PWM) scheme that will always ensure balanced voltage boosting of the Z-source network while simultaneously achieving reduced common-mode switching. Because of the omission of dead-time delays in the dual-inverter PWM scheme, its switched common-mode voltage can be completely eliminated, unlike in traditional inverters, where narrow common-mode spikes are still generated. Under semiconductor failure conditions, the presented PWM schemes can easily be modified to allow the inverter to operate without interruption, and for cases where two isolated sources are used, zero common-mode voltage can still be ensured. These theoretical findings, together with the inverter practicality, have been confirmed in simulations both using PSIM with Matlab/Simulink coupler and experimentally using a laboratory-implemented inverter prototype.
Resumo:
Dual-active bridges (DABs) can be used to deliver isolated and bidirectional power to electric vehicles (EVs) or to the grid in vehicle-to-grid (V2G) applications. However, such a system essentially requires a two-stage power conversion process, which significantly increases the power losses. Furthermore, the poor power factor associated with DAB converters further reduces the efficiency of such systems. This paper proposes a novel matrix converter based resonant DAB converter that requires only a single-stage power conversion process to facilitate isolated bi-directional power transfer between EVs and the grid. The proposed converter comprises a matrix converter based front end linked with an EV side full-bridge converter through a high frequency isolation transformer and a tuned LCL network. A mathematical model, which predicts the behavior of the proposed system, is presented to show that both the magnitude and direction of the power flow can be controlled through either relative phase angle or magnitude modulation of voltages produced by converters. Viability of the proposed concept is verified through simulations. The proposed matrix converter based DAB, with a single power conversion stage, is low in cost, and suites charging and discharging in single or multiple EVs or V2G applications.
Resumo:
Battery-supercapacitor hybrid energy storage systems are becoming popular in the renewable energy sector due to their improved power and energy performances. These hybrid systems require separate dc-dc converters, or at least one dc-dc converter for the supercapacitor bank, to connect them to the dc-link of the grid interfacing inverter. These additional dc-dc converters increase power losses, complexity and cost. Therefore, possibility of their direct connection is investigated in this paper. The inverter system used in this study is formed by cascading two 3-level inverters, named as the “main inverter” and the “auxiliary inverter”, through a coupling transformer. In the test system the main inverter is connected with the rectified output of a wind generator while the auxiliary inverter is directly attached to a battery and a supercapacitor bank. The major issues with this approach are the dynamic changes in dc-link voltages and inevitable imbalances in the auxiliary inverter voltages, which results in unevenly distributed space vectors. A modified SVM technique is proposed to solve this issue. A PWM based time sharing method is proposed for power sharing between the battery and the supercapacitor. Simulation results are presented to verify the efficacy of the proposed modulation and control techniques.
Resumo:
Additional converters that are used to interface energy storage devices incur power losses as well as increased system cost and complexity. The need for additional converters can be eliminated if the grid side inverter can itself be effectively used as the interface for energy storage. This paper therefore proposes a technique whereby the grid side inverter can also be used as an interface to connect a supercapacitor energy storage for wind energy conversion systems. The proposed grid side inverter is formed by cascading a 3-level inverter and a 2-level inverter through a coupling transformer. The three-level inverter is the main inverter and it is powered by the rectified output of the wind turbine coupled AC generator while the 2-level auxiliary inverter is connected to the super capacitor bank that is used to compensate short term power fluctuations. Novel modulation and control techniques are proposed to address the problems associated with non-integer and dynamically-changing dc-link voltage ratio, which is caused by the random nature of wind. Simulation results are presented to verify the efficacy of the proposed system in suppressing short term wind power fluctuations.
Resumo:
A switching control strategy is proposed for current-fed half-bridge converters. An active switch based voltage doubler circuit at the secondary side of the isolation transformer is used to obtain zero-current-switching at turn-off and zero-voltage-switching at turn-on in the primary side switches of the current-fed half-bridge converter. The operation of the current-fed half-bridge converter with the proposed switching control strategy is explained using the equivalent circuit during each sub-interval of operation. The operation of the current-fed halfbridge converter is simulated using MATLAB/Simpower and PSIM to verify the feasibility of the switching control strategy. Experimental results are provided to validate the converter's operation.
Resumo:
This paper presents a novel concept of Energy Storage System (ESS) interfacing with the grid side inverter in wind energy conversion systems. The inverter system used here is formed by cascading a 2-level inverter and a three level inverter through a coupling transformer. The constituent inverters are named as the “main inverter” and the “auxiliary inverter” respectively. The main inverter is connected with the rectified output of the wind generator while the auxiliary inverter is attached to a Battery Energy Storage System (BESS). The BESS ensures constant power dispatch to the grid irrespective of change in wind condition. Furthermore, this unique combination of BESS and inverter eliminates the need of additional dc-dc converters. Novel modulation and control techniques are proposed to address the problem of non-integer, dynamically-changing dc-link voltage ratio, which is due to random wind changes. Strategies used to handle auxiliary inverter dc-link voltage imbalances and controllers used to charge batteries at different rates are explained in detail. Simulation results are presented to verify the efficacy of the proposed modulation and control techniques in suppressing random wind power fluctuations.
Resumo:
The contamination of electrical insulators is one of the major contributors to the risk of operation outages in electrical substations, especially in coastal zones with high salinity levels and atmospheric pollution. By using the measurement of leakage-currents, which is one of the main indicators of contamination in insulators, this work seeks to the determine the correlation with climatic variables, such as ambient temperature, relative humidity, solar irradiance, atmospheric pressure, and wind speed and direction. The results obtained provide an input to the behaviour of the leakage current under atmospheric conditions that are particular to the Caribbean coast of Colombia. Spearman’s rank correlation coefficients and principal component analysis are utilised to determine the significant relationships among the different variables under consideration. The necessary information for the study was obtained via historical databases of both atmospheric variables and the leakage current measured in over a period of one year in a 220-kV potential transformer insulator. We identified the influencing factors of temperature, humidity, radiation, wind speed and direction on the magnitude of the leakage current as the most relevant.
Resumo:
This paper explores the possibility of using grid side inverter as an interface to connect energy storage systems. A dual inverter system, formed by cascading two 2-level inverters through a coupling transformer, is used as the testing model. The inverters are named as “main inverter” and “auxiliary inverter”. The main inverter is powered by the rectified output of the wind generator while the auxiliary inverter is attached to a Battery Energy Storage System (BESS). If there is a surplus of wind power compared to the demand, then that would be stored in BESS while if there is a deficit in wind power then the demand will be satisfied by supplying power from the BESS. This enables constant power dispatch to the grid irrespective of wind changes. Novel modulation and control techniques are proposed to address the problem of non-integer, dynamically-varying dc-link voltage ratio, which is due to random wind changes. Furthermore, a maximum power tracking controller for this unique system is explained in detail. Simulation results verify the efficacy of proposed modulation and control techniques in suppressing random power fluctuations.
Resumo:
This paper presents a novel STATCOM configuration for voltage quality improvement in wind power generation systems. The proposed STATCOM is formed by cascading two 3-level inverters, `bulk inverter' and `conditioning inverter', through a coupling transformer. Both inverters are powered by dc-link capacitors and they are charged by a small amount of active power drawn from the grid. To minimize switching losses, the high power bulk inverter operates at low frequency while low power high frequency conditioning inverter is used to suppress harmonic content produced by the bulk inverter output. With only 24 switches this topology can synthesize a nine level inverter, if the dc-link voltage ratio is maintained at 3:1. Modulation and control techniques have been developed to meet this requirement. Reactive power of the STATCOM is controlled to mitigate voltage sags or swells caused by sudden wind changes. Simulation and experimental results are presented to verify the efficacy of the proposed modulation and control techniques used in the STATCOM.
Resumo:
Inspired by similar reforms introduced in New Zealand, Canada and the United States, the Commonwealth, with the co-operation of the States, seeks in the Personal Property Securities Bill 2008 (the Bill) to introduce a central repository of recorded information reflecting particular security interests in personal property in Australia. Specifically, the interest recorded is an interest in personal property provided for by a transaction that in substance secures the payment or the performance of an obligation. In addition to providing a notification of the use of the personal property as collateral to secure the payment of monies or the performance of an obligation, the Bill proposes to introduce a regime of prioritising interests in the same collateral. Central to this prioritisation are the concepts of a ‘perfected security interests’and ‘unperfected security interests’. Relevantly, a perfected security interest in collateral has priority over an unperfected security interest in the same collateral. The proposed mechanisms rely on the fundamental integer of personal property, which is defined as any property other than land. Recognising that property may take a tangible as well as an intangible form, the Bill reflects an appreciation of the fact that some property may have a tangible form which may act as collateral, and simultaneously the same property may involve other property, intangible property in the form of intellectual property rights, which in their own right may be the subject of a‘security agreement’. An example set out in the Commentary on the Consultation Draft of the Bill (the Commentary), indicates the practical implications involving certain property which have multiple profiles for the purposes of the Bill. This submission is concerned with the presumptions made in relation to the interphase between tangible property and intangible property arising from the same personal property, as set out in s 30 of the Bill.
Resumo:
A switching control strategy is proposed for single and dual inductor current-fed push-pull converters. The proposed switching control strategy can be used with both current-fed push-pull converters with an active voltage doubler rectifier, or active rectifier, in the secondary side of the isolation transformer. The proposed switching control strategy makes turn-on and turn-off processes of the primary side power switches zero-voltage-switching and zero-current-switching respectively. The soft-switching operation of the single and dual inductor push-pull converters, with both types of active rectifier, is explained. Simulation and experimental results are provided to validate soft switching operation of the current-fed push-pull converters with the proposed switching control strategy.
Resumo:
The biological impact of Rho depends critically on the precise subcellular localization of its active, GTP-loaded form. This can potentially be determined by the balance between molecules that promote nucleotide exchange or GTP hydrolysis. However, how these activities may be coordinated is poorly understood. We now report a molecular pathway that achieves exactly this coordination at the epithelial zonula adherens. We identify an extramitotic activity of the centralspindlin complex, better understood as a cytokinetic regulator, which localizes to the interphase zonula adherens by interacting with the cadherin-associated protein, α-catenin. Centralspindlin recruits the RhoGEF, ECT2, to activate Rho and support junctional integrity through myosin IIA. Centralspindlin also inhibits the junctional localization of p190 B RhoGAP, which can inactivate Rho. Thus, a conserved molecular ensemble that governs Rho activation during cytokinesis is used in interphase cells to control the Rho GTPase cycle at the zonula adherens
Resumo:
Low voltage distribution networks feature a high degree of load unbalance and the addition of rooftop photovoltaic is driving further unbalances in the network. Single phase consumers are distributed across the phases but even if the consumer distribution was well balanced when the network was constructed changes will occur over time. Distribution transformer losses are increased by unbalanced loadings. The estimation of transformer losses is a necessary part of the routine upgrading and replacement of transformers and the identification of the phase connections of households allows a precise estimation of the phase loadings and total transformer loss. This paper presents a new technique and preliminary test results for a method of automatically identifying the phase of each customer by correlating voltage information from the utility's transformer system with voltage information from customer smart meters. The techniques are novel as they are purely based upon a time series of electrical voltage measurements taken at the household and at the distribution transformer. Experimental results using a combination of electrical power and current of the real smart meter datasets demonstrate the performance of our techniques.
Resumo:
This paper reviews the use of multi-agent systems to model the impacts of high levels of photovoltaic (PV) system penetration in distribution networks and presents some preliminary data obtained from the Perth Solar City high penetration PV trial. The Perth Solar City trial consists of a low voltage distribution feeder supplying 75 customers where 29 consumers have roof top photovoltaic systems. Data is collected from smart meters at each consumer premises, from data loggers at the transformer low voltage (LV) side and from a nearby distribution network SCADA measurement point on the high voltage side (HV) side of the transformer. The data will be used to progressively develop MAS models.