198 resultados para Interobserver


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Acetabular anatomy on AP pelvic radiographsdepends on pelvic orientation during radiograph acquisition. However, not all parameters may change to a clinically relevant degree with differences in pelvic orientation. This issue may influence the diagnosis of acetabular pathologies and planning of corrective acetabular surgery (reorientation or rim trimming). However, to this point, it has not been well characterized. Questions/purposes We asked (1) which radiographic parameters change in a clinical setting when normalized to neutral pelvic orientation; (2) which parameters do not change in an experimental setting when the pelvis is experimentally rotated/tilted; and (3) which of these changes are ‘‘ultimately’’ relevant based on a prespecified definition of relevance. Methods In a clinical setup, 11 hip parameters were evaluated in 101 patients (126 hips) by two observers and the interobserver difference was calculated. All parameters were normalized to an anatomically defined neutral pelvic orientation with the help of a lateral pelvic radiograph and specific software. Differences between nonnormalized and normalized values were calculated (effect of normalization). In an experimental setup involving 20 cadaver pelves (40 hips), the maximum range for each parameter was computed with the pelvis rotated (range, −12° to 12°) and tilted (range, −24° to 24°). ‘‘Ultimately’’ relevant changes existed if the effect of normalization exceeded the interobserver difference (eg, 37% versus 6% for prevalence of a positive crossover sign) and/or the maximum experimental range exceeded 1 SD of interobserver difference (eg, 27% versus 6% for anterior acetabular coverage). Results In the clinical setup, all parameters except the ACM angle and craniocaudal acetabular coverage changed when being normalized, eg, effect of normalization for lateral center-edge angle, acetabular index, and sharp angle ranged from −5° to 4° (p values < 0.029). In the experimental setup, five parameters showed no major changes, whereas six parameters did change (all p values < 0.001). Ultimately relevant changes were found for anteroposterior acetabular coverage, retroversion index, and prevalence of a positive crossover or posterior wall sign. Conclusions Lateral center-edge angle, ACM angle, Sharp angle, acetabular and extrusion index, and craniocaudal acetabular coverage showed no relevant changes with varying pelvic orientation and can therefore be acquired independent from individual pelvic tilt and rotation in clinical practice. In contrast, anteroposterior acetabular coverage, crossover and posterior wall sign, and retroversion index call for specific efforts that address individual pelvic orientation such as computer-assisted evaluation of radiographs. Level of Evidence Level III, diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS Information on tumour border configuration (TBC) in colorectal cancer (CRC) is currently not included in most pathology reports, owing to lack of reproducibility and/or established evaluation systems. The aim of this study was to investigate whether an alternative scoring system based on the percentage of the infiltrating component may represent a reliable method for assessing TBC. METHODS AND RESULTS Two hundred and fifteen CRCs with complete clinicopathological data were evaluated by two independent observers, both 'traditionally' by assigning the tumours into pushing/infiltrating/mixed categories, and alternatively by scoring the percentage of infiltrating margin. With the pushing/infiltrating/mixed pattern method, interobserver agreement (IOA) was moderate (κ = 0.58), whereas with the percentage of infiltrating margins method, IOA was excellent (intraclass correlation coefficient of 0.86). A higher percentage of infiltrating margin correlated with adverse features such as higher grade (P = 0.0025), higher pT (P = 0.0007), pN (P = 0.0001) and pM classification (P = 0.0063), high-grade tumour budding (P < 0.0001), lymphatic invasion (P < 0.0001), vascular invasion (P = 0.0032), and shorter survival (P = 0.0008), and was significantly associated with an increased probability of lymph node metastasis (P < 0.001). CONCLUSIONS Information on TBC gives additional prognostic value to pathology reports on CRC. The novel proposed scoring system, by using the percentage of infiltrating margin, outperforms the 'traditional' way of reporting TBC. Additionally, it is reproducible and simple to apply, and can therefore be easily integrated into daily diagnostic practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Autophagy assures cellular homeostasis, and gains increasing importance in cancer, where it impacts on carcinogenesis, propagation of the malignant phenotype and development of resistance. To date, its tissue-based analysis by immunohistochemistry remains poorly standardized. Here we show the feasibility of specifically and reliably assessing the autophagy markers LC3B and p62 (SQSTM1) in formalin fixed and paraffin embedded human tissue by immunohistochemistry. Preceding functional experiments consisted of depleting LC3B and p62 in H1299 lung cancer cells with subsequent induction of autophagy. Western blot and immunofluorescence validated antibody specificity, knockdown efficiency and autophagy induction prior to fixation in formalin and embedding in paraffin. LC3B and p62 antibodies were validated on formalin fixed and paraffin embedded cell pellets of treated and control cells and finally applied on a tissue microarray with 80 human malignant and non-neoplastic lung and stomach formalin fixed and paraffin embedded tissue samples. Dot-like staining of various degrees was observed in cell pellets and 18/40 (LC3B) and 22/40 (p62) tumors, respectively. Seventeen tumors were double positive for LC3B and p62. P62 displayed additional significant cytoplasmic and nuclear staining of unknown significance. Interobserver-agreement for grading of staining intensities and patterns was substantial to excellent (kappa values 0.60 - 0.83). In summary, we present a specific and reliable IHC staining of LC3B and p62 on formalin fixed and paraffin embedded human tissue. Our presented protocol is designed to aid reliable investigation of dysregulated autophagy in solid tumors and may be used on large tissue collectives.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neuroendocrine tumors (NET) are routinely graded and staged to judge prognosis. Proliferation index using MIB1 staining has been introduced to assess grading. There are vivid discussions on cutoff definitions, automated counting, and interobserver variability. However, no data exist regarding interlaboratory reproducibility for low proliferation indices which are of importance to discriminate between G1 and G2 NET. We performed MIB1 staining in three different university hospital-based pathology laboratories on a tissue micro array (TMA) of a well-characterized patient cohort, containing pancreatic NET of 61 patients. To calculate the proliferation index, number of positive tumor nuclei was divided by the total number of tumor nuclei. Labeling index was compared to mitotic counts in whole tissue sections and to clinical outcome. Linear regression analysis, intraclass comparison, and log-rank analysis were performed. Intraclass correlation showed moderate-to-fair agreement. Especially low proliferating tumors were affected by interlaboratory differences. Log-rank analysis was performed for each lab and resulted in three different cutoffs (5.0, 3.0, and 0.5 %). Every calculated cutoff stratified the patient cohort to a significant extent for the underlying stain (p < 0.001, <0.001, and <0.001) but showed no or lesser significance when applied to the other stains. Significant and relevant interlab differences for MIB1 exist. Since the MIB1 proliferation index influences grading, local cutoffs or external standardization should urgently be introduced to achieve reliability and reproducibility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A common debate among dermatopathologists is that prior knowledge of the clinical picture of melanocytic skin neoplasms may introduce a potential bias in the histopathologic examination. Histologic slides from 99 melanocytic skin neoplasms were circulated among 10 clinical dermatologists, all of them formally trained and board-certified dermatopathologists: 5 dermatopathologists had clinical images available after a 'blind' examination (Group 1); the other 5 had clinical images available before microscopic examination (Group 2). Data from the two groups were compared regarding 'consensus' (a diagnosis in agreement by ≥4 dermatopathologists/group), chance-corrected interobserver agreement (Fleiss' k) and level of diagnostic confidence (LDC: a 1-5 arbitrary scale indicating 'increasing reliability' of any given diagnosis). Compared with Group 1 dermatopathologists, Group 2 achieved a lower number of consensus (84 vs. 90) but a higher k value (0.74 vs. 0.69) and a greater mean LDC value (4.57 vs. 4.32). The same consensus was achieved by the two groups in 81/99 cases. Spitzoid neoplasms were most frequently controversial for both groups. The histopathologic interpretation of melanocytic neoplasms seems to be not biased by the knowledge of the clinical picture before histopathologic examination.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hip dysplasia is characterized by insufficient femoral head coverage (FHC). Quantification of FHC is of importance as the underlying goal of the surgery to treat hip dysplasia is to restore a normal acetabular morphology and thereby to improve FHC. Unlike a pure 2D X-ray radiograph-based measurement method or a pure 3D CT-based measurement method, previously we presented a 2.5D method to quantify FHC from a single anteriorposterior (AP) pelvic radiograph. In this study, we first quantified and compared 3D FHC between a normal control group and a patient group using a CT-based measurement method. Taking the CT-based 3D measurements of FHC as the gold standard, we further quantified the bias, precision and correlation between the 2.5D measurements and the 3D measurements on both the control group and the patient group. Based on digitally reconstructed radiographs (DRRs), we investigated the influence of the pelvic tilt on the 2.5D measurements of FHC. The intraclass correlation coefficients (ICCs) for absolute agreement was used to quantify interobserver reliability and intraobserver reproducibility of the 2.5D measurement technique. The Pearson correlation coefficient, r, was used to determine the strength of the linear association between the 2.5D and the 3D measurements. Student's t-test was used to determine whether the differences between different measurements were statistically significant. Our experimental results demonstrated that both the interobserver reliability and the intraobserver reproducibility of the 2.5D measurement technique were very good (ICCs > 0.8). Regression analysis indicated that the correlation was very strong between the 2.5D and the 3D measurements (r = 0.89, p < 0.001). Student's t-test showed that there were no statistically significant differences between the 2.5D and the 3D measurements of FHC on the patient group (p > 0.05). The results of this study provided convincing evidence demonstrating the validity of the 2.5D measurements of FHC from a single AP pelvic radiograph and proved that it could serve as a surrogate for 3D CT-based measurements. Thus it may be possible to use this method to avoid a CT scan for the purpose of estimating 3D FHC in diagnosis and post-operative treatment evaluation of patients with hip dysplasia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION Conventional 2-dimensional radiography uses defined criteria for outcome assessment of apical surgery. However, these radiographic healing criteria are not applicable for 3-dimensional radiography. The present study evaluated the repeatability and reproducibility of new cone-beam computed tomographic (CBCT)-based healing criteria for the judgment of periapical healing 1 year after apical surgery. METHODS CBCT scans taken 1 year after apical surgery (61 roots of 54 teeth in 54 patients, mean age = 54.4 years) were evaluated by 3 blinded and calibrated observers using 4 different indices. Reformatted buccolingual CBCT sections through the longitudinal axis of the treated roots were analyzed. Radiographic healing was assessed at the resection plane (R index), within the apical area (A index), of the cortical plate (C index), and regarding a combined apical-cortical area (B index). All readings were performed twice to calculate the intraobserver agreement (repeatability). Second-time readings were used for analyzing the interobserver agreement (reproducibility). Various statistical tests (Cohen, kappa, Fisher, and Spearman) were performed to measure the intra- and interobserver concurrence, the variability of score ratios, and the correlation of indices. RESULTS For all indices, the rates of identical first- and second-time scores were always higher than 80% (intraobserver Cohen κ values ranging from 0.793 to 0.963). The B index (94.0%) showed the highest intraobserver agreement. Regarding interobserver agreement, the highest rate was found for the B index (72.1%). The Fleiss' κ values for R and B indices exhibited substantial agreement (0.626 and 0.717, respectively), whereas the values for A and C indices showed moderate agreement (0.561 and 0.573, respectively). The Spearman correlation coefficients for R, A, C, and B indices all exhibited a moderate to very strong correlation with the highest correlation found between C and B indices (rs = 0.8069). CONCLUSIONS All indices showed an excellent intraobserver agreement (repeatability). With regard to interobserver agreement (reproducibility), the B index (healing of apical and cortical defects combined) and the R index (healing on the resection plane) showed substantial congruence and thus are to be recommended in future studies when using buccolingual CBCT sections for radiographic outcome assessment of apical surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

UNLABELLED The purpose of this study was to evaluate the reproducibility of a new software based analysing system for ventilation/perfusion single-photon emission computed tomography/computed tomography (V/P SPECT/CT) in patients with pulmonary emphysema and to compare it to the visual interpretation. PATIENTS, MATERIAL AND METHODS 19 patients (mean age: 68.1 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. Data were analysed by two independent observers in visual interpretation (VI) and by software based analysis system (SBAS). SBAS PMOD version 3.4 (Technologies Ltd, Zurich, Switzerland) was used to assess counts and volume per lung lobe/per lung and to calculate the count density per lung, lobe ratio of counts and ratio of count density. VI was performed using a visual scale to assess the mean counts per lung lobe. Interobserver variability and association for SBAS and VI were analysed using Spearman's rho correlation coefficient. RESULTS Interobserver agreement correlated highly in perfusion (rho: 0.982, 0.957, 0.90, 0.979) and ventilation (rho: 0.972, 0.924, 0.941, 0.936) for count/count density per lobe and ratio of counts/count density in SBAS. Interobserver agreement correlated clearly for perfusion (rho: 0.655) and weakly for ventilation (rho: 0.458) in VI. CONCLUSIONS SBAS provides more reproducible measures than VI for the relative tracer uptake in V/P SPECT/CTs in patients with pulmonary emphysema. However, SBAS has to be improved for routine clinical use.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE To investigate whether the effects of hybrid iterative reconstruction (HIR) on coronary artery calcium (CAC) measurements using the Agatston score lead to changes in assignment of patients to cardiovascular risk groups compared to filtered back projection (FBP). MATERIALS AND METHODS 68 patients (mean age 61.5 years; 48 male; 20 female) underwent prospectively ECG-gated, non-enhanced, cardiac 256-MSCT for coronary calcium scoring. Scanning parameters were as follows: Tube voltage, 120 kV; Mean tube current time-product 63.67 mAs (50 - 150 mAs); collimation, 2 × 128 × 0.625 mm. Images were reconstructed with FBP and with HIR at all levels (L1 to L7). Two independent readers measured Agatston scores of all reconstructions and assigned patients to cardiovascular risk groups. Scores of HIR and FBP reconstructions were correlated (Spearman). Interobserver agreement and variability was assessed with ĸ-statistics and Bland-Altmann-Plots. RESULTS Agatston scores of HIR reconstructions were closely correlated with FBP reconstructions (L1, R = 0.9996; L2, R = 0.9995; L3, R = 0.9991; L4, R = 0.986; L5, R = 0.9986; L6, R = 0.9987; and L7, R = 0.9986). In comparison to FBP, HIR led to reduced Agatston scores between 97 % (L1) and 87.4 % (L7) of the FBP values. Using HIR iterations L1 - L3, all patients were assigned to identical risk groups as after FPB reconstruction. In 5.4 % of patients the risk group after HIR with the maximum iteration level was different from the group after FBP reconstruction. CONCLUSION There was an excellent correlation of Agatston scores after HIR and FBP with identical risk group assignment at levels 1 - 3 for all patients. Hence it appears that the application of HIR in routine calcium scoring does not entail any disadvantages. Thus, future studies are needed to demonstrate whether HIR is a reliable method for reducing radiation dose in coronary calcium scoring.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Obesity has been on the rise in the United States over the last 30 years for all populations, including preschoolers. The purpose of the project was to develop an observation tool to measure physical activity levels in preschool children and use the tool in a pilot test of the CATCH UP curriculum at two Head Start Centers in Houston. Pretest and posttest interobserver agreements were all above 0.60 for physical activity level and physical activity type. Preschoolers spent the majority of their time in light physical activity (75.33% pretest, 87.77% posttest), and spent little time in moderate to vigorous physical activity (MVPA) (24.67% pretest, 12.23% posttest). Percent time spent in MVPA decreased significantly pretest to posttest from (F=5.738, p=0.043). While the pilot testing of the CATCH UP curriculum did not show an increase in MVPA, the SOFIT-P tool did show promising results as being a new method for collecting physical activity level data for preschoolers. Once the new tool has undergone more reliability and validity testing, it could allow for a more convenient method of collecting physical activity levels for preschoolers. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A imagem digital adquirida pelo sistema da placa de fósforo foto ativada é visualizada no monitor do computador em um formato denominado DICOM. Este formato ocupa muito espaço para armazenamento, o que dificulta o arquivamento e transmissão da imagem pela Internet. O objetivo deste estudo foi avaliar a influência da compressão JPEG, nos Fatores de Qualidade 100, 80 e 60 na reprodutibilidade da marcação de pontos cefalométricos em imagens de telerradiografias em norma lateral comparadas com o formato DICOM. A amostra consistiu de 120 imagens de telerradiografias em norma lateral obtidas a partir de 30 indivíduos, dos quais se obteve uma radiografia digital no formato DICOM. Essas imagens foram convertidas para o formato JPEG. Após o cegamento e randomização da amostra, três Ortodontistas calibrados marcaram a localização de 12 pontos cefalométricos em cada imagem utilizando o sistema de coordenadas X e Y. Esse procedimento foi repetido após 1 mês. A reprodutibilidade intra e inter observador foi calculada usando o teste de correlação intraclasse. Para comparação entre os grupos de compressão e DICOM na reprodutibilidade de marcação dos pontos utilizou se a Análise de Variância (ANOVA) a um critério para medidas repetidas. Os resultados mostraram que as marcações dos pontos cefalométricos foram bastante reprodutíveis, exceto para o ponto Órbita na coordenada X. Os diferentes formatos de arquivo mostraram estatisticamente iguais para cada ponto e eixo aferido. As compressões JPEG estudadas das imagens de telerradiografias em norma lateral não tiveram efeito na reprodutibilidade da marcação dos pontos cefalométricos testados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A imagem digital adquirida pelo sistema da placa de fósforo foto ativada é visualizada no monitor do computador em um formato denominado DICOM. Este formato ocupa muito espaço para armazenamento, o que dificulta o arquivamento e transmissão da imagem pela Internet. O objetivo deste estudo foi avaliar a influência da compressão JPEG, nos Fatores de Qualidade 100, 80 e 60 na reprodutibilidade da marcação de pontos cefalométricos em imagens de telerradiografias em norma lateral comparadas com o formato DICOM. A amostra consistiu de 120 imagens de telerradiografias em norma lateral obtidas a partir de 30 indivíduos, dos quais se obteve uma radiografia digital no formato DICOM. Essas imagens foram convertidas para o formato JPEG. Após o cegamento e randomização da amostra, três Ortodontistas calibrados marcaram a localização de 12 pontos cefalométricos em cada imagem utilizando o sistema de coordenadas X e Y. Esse procedimento foi repetido após 1 mês. A reprodutibilidade intra e inter observador foi calculada usando o teste de correlação intraclasse. Para comparação entre os grupos de compressão e DICOM na reprodutibilidade de marcação dos pontos utilizou se a Análise de Variância (ANOVA) a um critério para medidas repetidas. Os resultados mostraram que as marcações dos pontos cefalométricos foram bastante reprodutíveis, exceto para o ponto Órbita na coordenada X. Os diferentes formatos de arquivo mostraram estatisticamente iguais para cada ponto e eixo aferido. As compressões JPEG estudadas das imagens de telerradiografias em norma lateral não tiveram efeito na reprodutibilidade da marcação dos pontos cefalométricos testados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A imagem radiográfica digital adquirida pelo sistema de placa de fósforo foto ativada é normalmente visualizada no monitor do computador no formato DICOM, caracterizado pela alta resolução das imagens. Como este formato ocupa muito espaço para armazenamento, as imagens digitais são submetidas a uma compressão, que otimiza a capacidade de espaço dos computadores e reduz o tempo de transmissão pela Internet. O objetivo desse estudo foi avaliar a influência da compressão TIFF e JPEG na reprodutibilidade intra e interexaminador da marcação de pontos cefalométricos em imagens de telerradiografias em norma lateral comparadas com o formato DICOM. A amostra consistiu de 90 imagens de telerradiografias obtidas a partir de 30 indivíduos, dos quais se obteve uma radiografia digital exibida no formato DICOM. Estas imagens foram convertidas para os formatos JPEG, com Fator de Qualidade 80 e TIFF. Após o cegamento e randomização da amostra, três ortodontistas calibrados marcaram a localização de 15 pontos cefalométricos em cada imagem utilizando o sistema de coordenadas x e y. Os resultados mostraram que as marcações dos pontos cefalométricos apresentaram concordância de reprodutibilidade tanto intra como interexaminador, exceto para os pontos Go, Po, Or, B e Pog . Os diferentes formatos de arquivo mostraram resultados estatisticamente semelhantes para cada ponto e eixo aferido. As compressões JPEG e TIFF estudadas não tiveram efeito, em imagens de telerradiografias em norma lateral, na reprodutibilidade intra e interexaminadores da marcação dos pontos cefalométricos testados.(AU)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A imagem radiográfica digital adquirida pelo sistema de placa de fósforo foto ativada é normalmente visualizada no monitor do computador no formato DICOM, caracterizado pela alta resolução das imagens. Como este formato ocupa muito espaço para armazenamento, as imagens digitais são submetidas a uma compressão, que otimiza a capacidade de espaço dos computadores e reduz o tempo de transmissão pela Internet. O objetivo desse estudo foi avaliar a influência da compressão TIFF e JPEG na reprodutibilidade intra e interexaminador da marcação de pontos cefalométricos em imagens de telerradiografias em norma lateral comparadas com o formato DICOM. A amostra consistiu de 90 imagens de telerradiografias obtidas a partir de 30 indivíduos, dos quais se obteve uma radiografia digital exibida no formato DICOM. Estas imagens foram convertidas para os formatos JPEG, com Fator de Qualidade 80 e TIFF. Após o cegamento e randomização da amostra, três ortodontistas calibrados marcaram a localização de 15 pontos cefalométricos em cada imagem utilizando o sistema de coordenadas x e y. Os resultados mostraram que as marcações dos pontos cefalométricos apresentaram concordância de reprodutibilidade tanto intra como interexaminador, exceto para os pontos Go, Po, Or, B e Pog . Os diferentes formatos de arquivo mostraram resultados estatisticamente semelhantes para cada ponto e eixo aferido. As compressões JPEG e TIFF estudadas não tiveram efeito, em imagens de telerradiografias em norma lateral, na reprodutibilidade intra e interexaminadores da marcação dos pontos cefalométricos testados.(AU)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A lesão do plexo braquial é considerada a alteração neural mais grave das extremidades. A principal causa é o trauma de alta energia, especialmente acidentes envolvendo veículos a motor. Por este motivo, as lesões traumáticas do plexo braquial são cada vez mais frequentes. O presente estudo avaliou a acurácia da ressonância magnética (RM) no diagnóstico das lesões traumáticas do plexo braquial no adulto, utilizando o achado intraoperatório como padrão-ouro. Também foi avaliada a acurácia da neurografia pesada em difusão (neurografia DW) em relação à RM convencional e a capacidade de diferenciação dos três tipos de lesão: avulsão, ruptura e lesão em continuidade. Trinta e três pacientes com história e diagnóstico clínico de lesão traumática do plexo braquial foram prospectivamente estudados por RM. Os achados obtidos pela RM sem e com o uso da neurografia DW, e os achados de exame clínico foram comparados com os achados intraoperatórios. A análise estatística foi feita com associação de significância de 5%. Observou-se alta correlação entre a RM com neurografia DW e a cirurgia (rs=0,79), e baixa correlação entre a RM convencional e a cirurgia (rs=0,41). A correlação interobservador foi maior para a RM com neurografia DW (rs = 0,94) do que para a RM sem neurografia DW (rs = 0,75). Os resultados de sensibilidade, acurácia e valor preditivo positivo foram acima de 95% para as RM com e sem neurografia DW no estudo de todo o plexo. As especificidades foram, em geral, maiores para a neurografia DW (p < 0,05). Em relação à diferenciação dos tipos de lesão, a RM com neurografia DW apresentou altas acurácias e sensibilidades no diagnóstico da avulsão/rotura, e alta especificidade no diagnóstico da lesão em continuidade. A acurácia da RM (93,9%) foi significativamente maior que a do exame clínico (76,5%) no diagnóstico das lesões de todo o plexo braquial (p < 0,05).