792 resultados para Implantes cocleares


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mini-implant has become a device for anchorage quite widespread and current employee in Orthodontics. The effectiveness of mini-implant is mostly due for its stability primary, however is important to understand about factors that influence the stability. This article presents a review of literature in the database, and as a criterion for inclusion in articles published on the factors related to the stability of mini-implant carried out on humans and animals. The articles was selected according selection criteria related to stability, The factors of mini-implants stability have been described in the literature with scattered scientific information, most of them just as clinical observations. However, these factors of stability can be classified in relation to screw, professional and patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As an innovative transitory anchorage device, the mini-implants deserve to be described with details regarding its use and action during orthodontic treatment. Therefore, this paper intents to present some biomechanic criteria adopted to for a better use of mini-implants as anchorage in anterior retraction (space closure), molar distalization, mesial movement of the molars, intrusion of molars and as support to provisional implant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atualmente o titânio é empregado como biomaterial devido à sua biocompatibilidade e resistência à corrosão. Entretanto, íons fluoretos, freqüentemente empregados em dentifrícios bucais, podem interferir no processo de corrosão. O objetivo deste estudo foi analisar a influência de um meio fluoretado com diferentes pH nas propriedades mecânicas e na resistência à corrosão dos conjuntos implantes/componentes protéticos à base de Ti c.p., a partir dos testes de fadiga, microscopia eletrônica de varredura (MEV) e dureza. Foram simulados cinco anos de uso regular de meios de higiene oral com conteúdo de 1500 ppm de NaF, com dois diferentes pH, 7,4 e 5,3, mediante imersão das amostras nesses meios durante 184 horas e também em água destilada, grupo controle. As amostras foram testadas num durômetro Micromet 2001 (500gf/30s). Os dados dos testes de dureza foram analisados pelo teste de Wilcoxon, demonstrando que as amostras sofreram influência negativa na dureza após a ação dos íons fluoreto. Entretanto, essa influência não ocorreu nos testes de fadiga realizados em uma máquina de ensaios mecânicos MTS-810, fixada a 100.000 ciclos, 15Hz e programada com força de fadiga a 150 N. Pela análise de MEV foram constatadas evidências de corrosão na superfície das amostras após ação de íons fluoretos, entretanto pelo EDS não se verificou incorporação de íons fluoretos sobre a superfície dos conjuntos. Concluiu-se que a concentração de flúor e o pH das soluções não exerceram influência nas propriedades mecânicas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The biological principles of osseointegration caused the rehabilitation treatment with osseointegrated implant become a safe, well alternative accepted by the dental community for the high success rate, allowing the preparation of functional and aesthetic prostheses in edentulous and partial patients. We passed the initial phase of functional vision for an aesthetic approach, too, depending on the demands of the patient and the quest for excellence by professionals. Over these last years, implant treatment has undergone many changes in surgical and prosthetic protocols. The less invasive surgical techniques and the development of restorative materials, especially ceramics allow the prosthetic rehabilitation of high functional quality and aesthetics. The installation of implants in sockets immediately after extraction of teeth involved by fracture, periodontal disease, endodontic lesions, is part of the arsenal of techniques for rehabilitating a number of advantages that we get to the outcome of multidisciplinary treatment. For this, we must consider several criteria in its planning as a fundamental unit, adjacent teeth, multiple losses, system, form and number of implants, type of retention of the prosthesis components, the patient expectation of the outcome perspective, gingival biotype, standard of ridge resorption, the smile line, etc. occlusal analysis. With the three-dimensional placement of the implant can immediately join the biological processes of repair of the socket, implant osseointegration, speeding treatment time. Much has been made by companies in the surface treatment of endosseous implants to be osseointegration shortened and restorative procedures started earlier, bringing benefits to the patient and professional. Among the main advantages we can emphasize the preservation of the structures adjacent to the teeth replaced, minor resorption of bone tissue involved... (Complete abstract click electronic access below)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this in vitro study was quantify the micro strain development around the internal hexagon implants, varying the type of prosthetic coping. For This reason, three implants of internal hexagon were inserted into one polyurethane block in line placement. Microunit abutments were screwed onto the implants. Tangentially the implants were bonded the strain gauges, two to the center implant. Ten structures, each one containing three copings were cast in Co-Cr alloy, that were divided into groups in the first group, plastic copings were used, and in the second group machined copings were used. The superstructure’s occlusal screws were tightened onto Microunit abutments with 10 Ncm torque, the magnitude of micro strain was recorded. The mean values of each strain gauge of each plastic copings were 363,37 ± 237,66 and the machined copings were 338,12 ± 223,01. The data were analyzed statistically by t- Student test. No statistically significant difference was found between the prosthetic copings (p= 0,867). It was concluded that to internal hexagon implants in line placement, the type of copings presented similar magnitude of micro strain after prosthetic occlusal screw was tightened

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)