936 resultados para Implant removal
Resumo:
Yhteenveto: Rauta ja mangaani Suomen glasifluviaalisten akviferien pohjavedessä ja poisto biosuodatuksella
Resumo:
A commercial acrylic fiber with 92% (w/w) acrylonitrile content was partially hydrolyzed converting a fraction of the nitrile (-CN) groups to carboxylic acid (-COOH) groups, to coat the fiber with polyethylenimine (PEI) resin, which was then crosslinked with glutaraldehyde and further quaternized with ethyl chloroacetate to produce a novel strong-base anionic exchanger in the form of fiber. Designated as PAN(QPEI.XG)(Cl-), the fibrous sorbent was compared with a commercial bead-form resin Amberlite IRA-458(Cl-) in respect of sorption capacity, selectivity, and kinetics for removal of silver thiosulfate complexes from aqueous solutions. Though the saturation level of [Ag(S2O3)(2)](3-) on PAN(QPEI.XG)(Cl-) is considerably less than that on IRA-458(Cl-), the gel-coated fibrous sorbent exhibits, as compared to the bead-form sorbent, a significantly higher sorption selectivity for the silver thiosulfate complex in the presence of excess of other anions Such as S2O32-, SO42-, and Cl-, and a remarkably faster rate of both sorption and stripping. The initial uptake of the sorbate by the fibrous sorbent is nearly instantaneous, reaching up to similar to 80% of the saturation capacity within 10 s, as compared to only similar to 12% on the bead-form sorbent. The high initial rate of uptake fits a shell-core kinetic model for sorption on fiber of cylindrical geometry. With 4M HCl, the stripping of the sorbed silver complex from the fibrous sorbent is clean and nearly instantaneous, while, in contrast, a much slower rate of stripping on the bead-form sorbent leads to its fouling due to a slow decomposition of the silver thiosulfate complex in the acidic medium.
Resumo:
The utility of rice husk as an adsorbent for metal ions such as iron, zinc and copper from acid mine water was assessed. The adsorption isotherms exhibited Langmuirian behavior and were endothermic in nature. The free energy values for adsorption of the chosen metal ions onto rice husk were found to be highly negative attesting to favorable interaction. Over 99% Fe3+, 98% of Fe2+ and Zn2+ and 95% Cu2+ uptake was achieved from acid mine water, with a concomitant increase in the pH value by two units using rice husk. The remediation studies carried out on acid mine water and simulated acid mine water pretreated with rice husk indicated successful growth of Desulfotomaculum nigrificans (D. nigrificans). The amount of sulphate bioreduction in acid mine water at an initial pH of 5.3 was enhanced by D. nigrificans from 21% to 40% in the presence of rice husk filtrate supplemented with carbon and nitrogen. In simulated acid mine water with fortified husk filtrate, the sulphate reduction was even more extensive, with an enhancement to 73%. Concurrently, almost 90% Fe2+, 89% Zn2+ and 75% Cu2+ bioremoval was attained from simulated acid mine water. Metal adsorption by rice husk was confirmed in desorption experiments in which almost complete removal of metal ions from the rice husk was achieved after two elutions using 1 M HCl. The possible mechanisms of metal ion adsorption onto rice husk and sulphate reduction using D. nigrificans are discussed.
Resumo:
In this paper, we propose a systolic architecture for hidden-surface removal. Systolic architecture is a kind of parallel architecture best known for its easy VLSI implementability. After discussing the design details of the architecture, we present the results of the simulation experiments conducted in order to evaluate the performance of the architecture.
Resumo:
Yhteenveto: Acinetobacter sp. metsäteollisuuden jätevesien biologisessa fosforinpoistossa
Resumo:
X-ray absorption spectra at the oxygen K edge using the total yield technique are reported for YBa2Cu3O6.9 and YBa2Cu2.7Fe0.3O6.9. A comparison of the two spectra reveals that the mobile holes in YBa2Cu3O7-δ are removed and localized on Fe doping. Fe thus enters the lattice primarily in the formally trivalent oxidation state.
Resumo:
Removal of impurity elements from hot metal is essential in basic oxygen steelmaking. Oxidation of phosphorus from hot metal has been studied by several authors since the early days of steelmaking. Influence of different parameters on the distribution of phosphorus, seen during the recent work of the authors, differs somewhat from that reported earlier. On the other hand, removal of sulphur during steelmaking has drawn much less attention. This may be due to the magnitude of desulphurisation in oxygen steelmaking being relatively low and desulphurisation during hot metal pre-treatment or in the ladle furnace offering better commercial viability Further, it is normally accepted that sulphur is removed to steelmaking slag in the form of sulphide only However, recent investigations have indicated that a significant amount of sulphur removed during basic oxygen steelmaking can exist in the form of sulphate in the slag under oxidising conditions. The distribution of sulphur during steelmaking becomes more important in the event of carry-over of sulphur-rich blast-furnace slag, which increases sulphur load in the BOF. The chemical nature of sulphur in this slag undergoes a gradual transition from sulphide to sulphate as the oxidative refining progresses.
Resumo:
The potential to remove chromium(VI) from aqueous solutions through biosorption using coffee husk was investigated. The effects of pH, contact time, initial concentration and adsorbent dosage on the adsorption of Cr(VI) were studied. The data obeyed Langmuir and Freundlich adsorption isotherms. The Langmuir adsorption capacity was found to be 44.95 mg/g. The Freundlich constants K-f and n were 1.027 mg/g (litre/mg)(n)] and 1.493, respectively. Desorption studies indicated the removal of 60% of the hexavalent chromium. Infrared spectral studies revealed the presence of functional groups, such as hydroxyl and carboxyl groups, on the surface of the biomass, which facilitates biosorption of Cr(VI).
Resumo:
With the advent of VLSI it has become possible to map parallel algorithms for compute-bound problems directly on silicon. Systolic architecture is very good candidate for VLSI implementation because of its regular and simple design, and regular communication pattern. In this paper, a systolic algorithm and corresponding systolic architecture, a linear systolic array, for the scanline-based hidden surface removal problem in three-dimensional computer graphics have been proposed. The algorithm is based on the concept of sample spans or intervals. The worst case time taken by the algorithm is O(n), n being the number of segments in a scanline. The time taken by the algorithm for a given scene depends on the scene itself, and on an average considerable improvement over the worst case behaviour is expected. A pipeline scheme for handling the I/O process has also been proposed which is suitable for VLSI implementation of the algorithm.
Resumo:
Improved performance of plasma in raw engine exhaust treatment is reported. A new type of reactor referred to as of cross-flow dielectric barrier discharge (DBD) was used, in which the gas flow is perpendicular to the corona electrode. In raw exhaust environment, the cross-flow (radial-flow) reactor exhibits a superior performance with regard to NOX removal when compared to that with axial flow of gas. Experiments were conducted at different flow rates ranging from 2 L/min to 25 L/min. The plasma assisted barrier discharge reactor has shown encouraging results in NOx removal at high flow rates.
Resumo:
Experiments have been conducted to obtain the optimum conditions of hydrogen ion concentration of feed and strip phases and concentration of the carrier ALAMINE 336, in the extraction of Cr(VI) and Hg(II) using two different types of liquid membranes-bulk liquid membrane and emulsion liquid membrane. Experiments have also been carried out to find the effect of metal loading and the effect of extraction time on metal flux.
Resumo:
The suitability of the European Centre for Medium Range Weather Forecasting (ECMWF) operational wind analysis for the period 1980-1991 for studying interannual variability is examined. The changes in the model and the analysis procedure are shown to give rise to a systematic and significant trend in the large scale circulation features. A new method of removing the systematic errors at all levels is presented using multivariate EOF analysis. Objectively detrended analysis of the three-dimensional wind field agrees well with independent Florida State University (FSU) wind analysis at the surface. It is shown that the interannual variations in the detrended surface analysis agree well in amplitude as well as spatial patterns with those of the FSU analysis. Therefore, the detrended analyses at other levels as well are expected to be useful for studies of variability and predictability at interannual time scales. It is demonstrated that this trend in the wind field is due to the shift in the climatologies from the period 1980-1985 to the period 1986-1991.
Resumo:
The removal of noise and outliers from measurement signals is a major problem in jet engine health monitoring. Topical measurement signals found in most jet engines include low rotor speed, high rotor speed. fuel flow and exhaust gas temperature. Deviations in these measurements from a baseline 'good' engine are often called measurement deltas and the health signals used for fault detection, isolation, trending and data mining. Linear filters such as the FIR moving average filter and IIR exponential average filter are used in the industry to remove noise and outliers from the jet engine measurement deltas. However, the use of linear filters can lead to loss of critical features in the signal that can contain information about maintenance and repair events that could be used by fault isolation algorithms to determine engine condition or by data mining algorithms to learn valuable patterns in the data, Non-linear filters such as the median and weighted median hybrid filters offer the opportunity to remove noise and gross outliers from signals while preserving features. In this study. a comparison of traditional linear filters popular in the jet engine industry is made with the median filter and the subfilter weighted FIR median hybrid (SWFMH) filter. Results using simulated data with implanted faults shows that the SWFMH filter results in a noise reduction of over 60 per cent compared to only 20 per cent for FIR filters and 30 per cent for IIR filters. Preprocessing jet engine health signals using the SWFMH filter would greatly improve the accuracy of diagnostic systems. (C) 2002 Published by Elsevier Science Ltd.