927 resultados para Image processing, computer-assisted
Resumo:
Using diffusion tensor tractography, we quantified the microstructural changes in the association, projection, and commissural compact white matter pathways of the human brain over the lifespan in a cohort of healthy right-handed children and adults aged 6-68 years. In both males and females, the diffusion tensor radial diffusivity of the bilateral arcuate fasciculus, inferior longitudinal fasciculus, inferior fronto-occipital fasciculus, uncinate fasciculus, corticospinal, somatosensory tracts, and the corpus callosum followed a U-curve with advancing age; fractional anisotropy in the same pathways followed an inverted U-curve. Our study provides useful baseline data for the interpretation of data collected from patients.
Resumo:
Vesicular stomatitis virus (VSV) is a bullet-shaped rhabdovirus and a model system of negative-strand RNA viruses. Through direct visualization by means of cryo-electron microscopy, we show that each virion contains two nested, left-handed helices: an outer helix of matrix protein M and an inner helix of nucleoprotein N and RNA. M has a hub domain with four contact sites that link to neighboring M and N subunits, providing rigidity by clamping adjacent turns of the nucleocapsid. Side-by-side interactions between neighboring N subunits are critical for the nucleocapsid to form a bullet shape, and structure-based mutagenesis results support this description. Together, our data suggest a mechanism of VSV assembly in which the nucleocapsid spirals from the tip to become the helical trunk, both subsequently framed and rigidified by the M layer.
Resumo:
V2 has long been recognized to contain functionally distinguishable compartments that are correlated with the stripelike pattern of cytochrome oxidase activity. Early electrophysiological studies suggested that color, direction/disparity, and orientation selectivity were largely segregated in the thin, thick, and interstripes, respectively. Subsequent studies revealed a greater degree of homogeneity in the distribution of response properties across stripes, yet color-selective cells were still found to be most prevalent in the thin stripes. Optical recording studies have demonstrated that thin stripes contain both color-preferring and luminance-preferring modules. These thin stripe color-preferring modules contain spatially organized hue maps, whereas the luminance-preferring modules contain spatially organized luminance-change maps. In this study, the neuronal basis of these hue maps was determined by characterizing the selectivity of neurons for isoluminant hues in multiple penetrations within previously characterized V2 thin stripe hue maps. The results indicate that neurons within the superficial layers of V2 thin stripe hue maps are organized into columns whose aggregated hue selectivity is closely related to the hue selectivity of the optically defined hue maps. These data suggest that thin stripes contain hue maps not simply because of their moderate percentage of hue-selective neurons, but because of the columnar and tangential organization of hue selectivity.
Resumo:
INTRODUÇÃO: A prótese biliar endoscópica é aceita em todo o mundo como a primeira escolha de tratamento paliativo na obstrução biliar maligna. Atualmente ainda persistem dois tipos de materiais utilizados em sua confecção: plástico e metal. Consequentemente, muitas dúvidas surgem quanto a qual deles é o mais benéfico para o paciente. Esta revisão reúne as informações disponíveis da mais alta qualidade sobre estes dois tipos de prótese, fornecendo informações em relação à disfunção, complicação, taxas de reintervenção, custos, sobrevida e tempo de permeabilidade; e pretende ajudar a lidar com a prática clínica nos dias de hoje. OBJETIVO: Analisar, através de metanálise, os benefícios de dois tipos de próteses na obstrução biliar maligna inoperável. MÉTODOS: Uma revisão sistemática de ensaios clínicos randomizados (RCT) foi conduzida, com a última atualização em março de 2015, utilizando EMBASE, CINAHL (EBSCO), Medline, Lilacs / Centro (BVS), Scopus, o CAPES (Brasil), e literatura cinzenta. As informações dos estudos selecionados foram extraídas tendo em vista seis desfechos: primariamente disfunção, taxas de reintervenção e complicações; e, secundariamente, custos, sobrevivência e tempo de permeabilidade. Os dados sobre as características dos participantes do RCT, critérios de inclusão e exclusão e tipos de próteses também foram extraídos. Os vieses foram avaliados principalmente através da escala de Jadad. Esta metanálise foi registrada no banco de dados PROSPERO pelo número CRD42014015078. A análise do risco absoluto dos resultados foi realizada utilizando o software RevMan 5, calculando as diferenças de risco (RD) de variáveis dicotômicas e média das diferenças (MD) de variáveis contínuas. Os dados sobre a RD e MD para cada desfecho primário foram calculados utilizando o teste de Mantel-Haenszel e a inconsistência foi avaliada com o teste Qui-quadrado (Chi2) e o método de Higgins (I2). A análise de sensibilidade foi realizada com a retirada de estudos discrepantes e a utilização do efeito aleatório. O teste t de Student foi utilizado para a comparação das médias aritméticas ponderadas, em relação aos desfechos secundários. RESULTADOS: Inicialmente foram identificados 3660 estudos; 3539 foram excluídos por título ou resumo, enquanto 121 estudos foram totalmente avaliados e foram excluídos, principalmente por não comparar próteses metálicas (SEMS) e próteses plásticas (PS), levando a treze RCT selecionados e 1133 indivíduos metanálise. A média de idade foi de 69,5 anos, e o câncer mais comum foi de via biliar (proximal) e pancreático (distal). O diâmetro de SEMS mais utilizado foi de 10 mm (30 Fr) e o diâmetro de PS mais utilizado foi de 10 Fr. Na metanálise, SEMS tiveram menor disfunção global em comparação com PS (21,6% versus 46,8% p < 0,00001) e menos reintervenções (21,6% versus 56,6% p < 0,00001), sem diferença nas complicações (13,7% versus 15,9% p = 0,16). Na análise secundária, a taxa média de sobrevida foi maior no grupo SEMS (182 contra 150 dias - p < 0,0001), com um período maior de permeabilidade (250 contra 124 dias - p < 0,0001) e um custo semelhante por paciente, embora menor no grupo SEMS (4.193,98 contra 4.728,65 Euros - p < 0,0985). CONCLUSÃO: SEMS estão associados com menor disfunção, menores taxas de reintervenção, melhor sobrevida e maior tempo de permeabilidade. Complicações e custos não apresentaram diferença
Resumo:
Incidental findings on low-dose CT images obtained during hybrid imaging are an increasing phenomenon as CT technology advances. Understanding the diagnostic value of incidental findings along with the technical limitations is important when reporting image results and recommending follow-up, which may result in an additional radiation dose from further diagnostic imaging and an increase in patient anxiety. This study assessed lesions incidentally detected on CT images acquired for attenuation correction on two SPECT/CT systems. Methods: An anthropomorphic chest phantom containing simulated lesions of varying size and density was imaged on an Infinia Hawkeye 4 and a Symbia T6 using the low-dose CT settings applied for attenuation correction acquisitions in myocardial perfusion imaging. Twenty-two interpreters assessed 46 images from each SPECT/CT system (15 normal images and 31 abnormal images; 41 lesions). Data were evaluated using a jackknife alternative free-response receiver-operating-characteristic analysis (JAFROC). Results: JAFROC analysis showed a significant difference (P < 0.0001) in lesion detection, with the figures of merit being 0.599 (95% confidence interval, 0.568, 0.631) and 0.810 (95% confidence interval, 0.781, 0.839) for the Infinia Hawkeye 4 and Symbia T6, respectively. Lesion detection on the Infinia Hawkeye 4 was generally limited to larger, higher-density lesions. The Symbia T6 allowed improved detection rates for midsized lesions and some lower-density lesions. However, interpreters struggled to detect small (5 mm) lesions on both image sets, irrespective of density. Conclusion: Lesion detection is more reliable on low-dose CT images from the Symbia T6 than from the Infinia Hawkeye 4. This phantom-based study gives an indication of potential lesion detection in the clinical context as shown by two commonly used SPECT/CT systems, which may assist the clinician in determining whether further diagnostic imaging is justified.
Resumo:
An algorithm for the real-time registration of a retinal video sequence captured with a scanning digital ophthalmoscope (SDO) to a retinal composite image is presented. This method is designed for a computer-assisted retinal laser photocoagulation system to compensate for retinal motion and hence enhance the accuracy, speed, and patient safety of retinal laser treatments. The procedure combines intensity and feature-based registration techniques. For the registration of an individual frame, the translational frame-to-frame motion between preceding and current frame is detected by normalized cross correlation. Next, vessel points on the current video frame are identified and an initial transformation estimate is constructed from the calculated translation vector and the quadratic registration matrix of the previous frame. The vessel points are then iteratively matched to the segmented vessel centerline of the composite image to refine the initial transformation and register the video frame to the composite image. Criteria for image quality and algorithm convergence are introduced, which assess the exclusion of single frames from the registration process and enable a loss of tracking signal if necessary. The algorithm was successfully applied to ten different video sequences recorded from patients. It revealed an average accuracy of 2.47 ± 2.0 pixels (∼23.2 ± 18.8 μm) for 2764 evaluated video frames and demonstrated that it meets the clinical requirements.
Resumo:
A pilot study to detect volume changes of cerebral structures in growth hormone (GH)-deficient adults treated with GH using serial 3D MR image processing and to assess need for segmentation prior to registration was conducted.
Resumo:
Since the invention of photography humans have been using images to capture, store and analyse the act that they are interested in. With the developments in this field, assisted by better computers, it is possible to use image processing technology as an accurate method of analysis and measurement. Image processing's principal qualities are flexibility, adaptability and the ability to easily and quickly process a large amount of information. Successful examples of applications can be seen in several areas of human life, such as biomedical, industry, surveillance, military and mapping. This is so true that there are several Nobel prizes related to imaging. The accurate measurement of deformations, displacements, strain fields and surface defects are challenging in many material tests in Civil Engineering because traditionally these measurements require complex and expensive equipment, plus time consuming calibration. Image processing can be an inexpensive and effective tool for load displacement measurements. Using an adequate image acquisition system and taking advantage of the computation power of modern computers it is possible to accurately measure very small displacements with high precision. On the market there are already several commercial software packages. However they are commercialized at high cost. In this work block-matching algorithms will be used in order to compare the results from image processing with the data obtained with physical transducers during laboratory load tests. In order to test the proposed solutions several load tests were carried out in partnership with researchers from the Civil Engineering Department at Universidade Nova de Lisboa (UNL).