963 resultados para Illinois. Ambient Air Monitoring Section
Resumo:
This paper presents the instrumentation and control architecture for a laboratory based two-stage 4-bed silica gel + water adsorption system. The system consists of primarily two fluids: refrigerant (water vapour) and heat transfer fluid (water) flowing through various components. Heat input to the system is simulated using multiple heaters and ambient air is used as the heat sink. The laboratory setup incorporates a real time National Instruments (NI) controller to control several digital and analog valves, heaters, pumps and fans along with simultaneous data acquisition from various flow, pressure and temperature sensors. The paper also presents in detail the various automated and manual tasks required for successful operation of the system. Finally the system pressure and temperature dynamics are reported and its performance evaluated for various cycle times. (C) 2015 Elsevier Ltd. All rights reserved.
Resumo:
We report the synthesis of ZnO nanowires in ambient air at 650 degrees C by a single-step vapor transport method using two different sources Zn (ZnO nanowires-I) and Zn:Cu (ZnO nanowires-II). The Zn:Cu mixed source co-vaporize Zn with a small amount of Cu at temperatures where elemental Cu source does not vaporize. This method provides us a facile route for Cu doping into ZnO. The aspect ratio of the grown ZnO nanowires-II was found to be higher by more than five times compared ZnO nanowires-I. Photocatalytic activity was measured by using a solar simulator and its ultraviolet-filtered light. The ZnO nanowires-II shows higher catalytic activity due to increased aspect ratio and higher content of surface defects because of incorporation of Cu impurities.
Resumo:
在空气环境中利用氩等离子体射流进行材料加工时,环境空气卷吸进入射流可能会引起金属材料氧化.采用同轴屏蔽气体保护是减小该不利影响的一种可行方案.为此本文对空气环境中层流氩等离子体冲击射流特性受屏蔽气体影响问题进行了数值模拟研究,重点考察了屏蔽气体速度等对材料加工区氧含量的影响.
Resumo:
Modeling study is performed concerning the heat transfer and fluid flow for a laminar argon plasma jet impinging normally upon a flat workpiece exposed to the ambient air. The diffusion of the air into the plasma jet is handled by using the combined-diffusion-coefficient approach. The heat flux density and jet shear stress distributions at the workpiece surface obtained from the plasma jet modeling are then used to study the re-melting process of a carbon steel workpiece. Besides the heat conduction within the workpiece, the effects of the plasma-jet inlet parameters (temperature and velocity), workpiece moving speed, Marangoni convection, natural convection etc. on the re-melting process are considered. The modeling results demonstrate that the shapes and sizes of the molten pool in the workpiece are influenced appreciably by the plasma-jet inlet parameters, workpiece moving speed and Marangoni convection. The jet shear stress manifests its effect at higher plasma-jet inlet velocities, while the natural convection effect can be ignored. The modeling results of the molten pool sizes agree reasonably with available experimental data.
Resumo:
A numerical study on wave dynamic processes occurring in muzzle blast flows, which are created by a supersonic projectile released from the open-end of a shock tube into ambient air, is described in this paper. The Euler equations, assuming axisymmetric flows, are solved by using a dispersion-controlled scheme implemented with moving boundary conditions. Three test cases are simulated for examining friction effects on the muzzle flow. From numerical simulations, the wave dynamic processes, including two blast waves, two jet flows, the bow shock wave and their interactions in the muzzle blasts, are demonstrated and discussed in detail. The study shows that the major wave dynamic processes developing in the muzzle flow remain similar when the friction varies, but some wave processes, such as shock-shock interactions, shock-jet interactions and the contact surface instability, get more intensive, which result in more complex muzzle blast flows.
Resumo:
The generation, jet length and flow-regime change characteristics of argon plasma issuing into ambient air have been experimentally examined. Different torch structures have been used in the tests. Laminar plasma jets can be generated within a rather wide range of working-gas flow rates, and an unsteady transitional flow state exists between the laminar and turbulent flow regimes. The high-temperature region length of the laminar plasma jet can be over an order longer than that of the turbulent plasma jet and increases with increasing argon flow rate or arc current, while the jet length of the turbulent plasma is less influenced by the generating parameters. The flow field of the plasma jet has very high radial gradients of plasma parameters, and a Reynolds number alone calculated in the ordinary manner may not adequately serve as a criterion for transition. The laminar plasma jet can have a higher velocity than that of an unsteady or turbulent jet. The long laminar plasma jet has good stiffness to withstand the impact of laterally injected cold gas and particulate matter. It could be used as a rather ideal object for fundamental studies and be applied to novel materials processing due to its attractive stable and adjustable properties.
Resumo:
Capillary forces are significantly dominant in adhesive forces measured with an atomic force microscope (AFM) in ambient air, which are always thought to be dependent on water film thickness, relative humidity, and the free energy of water film. We study the nature of the pull-off force on a variety of surfaces as a function of tip velocity. It is found that the capillary forces are of relatively strong dependence on tip velocity. The present experiment is expected to provide a better understanding of the work mechanism of AFM in ambient air.
Resumo:
We report on an experimental and theoretical study of the transient flows which develop as a naturally ventilated room adjusts from one temperature to another. We focus on a room heated from below by a uniform heat source, with both high- and low-level ventilation openings. Depending on the initial temperature of the room relative to (i) the final equilibrium temperature and (ii) the exterior temperature, three different modes of ventilation may develop. First, if the room temperature lies between the exterior and the equilibrium temperature, the interior remains well-mixed and gradually heats up to the equilibrium temperature. Secondly, if the room is initially warmer than the equilibrium temperature, then a thermal stratification develops in which the upper layer of originally hot air is displaced upwards by a lower layer of relatively cool inflowing air. At the interface, some mixing occurs owing to the effects of penetrative convection. Thirdly, if the room is initially cooler than the exterior, then on opening the vents, the original air is displaced downwards and a layer of ambient air deepens from above. As this lower layer drains, it is eventually heated to the ambient temperature, and is then able to mix into the overlying layer of external air, and the room becomes well-mixed. For each case, we present new laboratory experiments and compare these with some new quantitative models of the transient flows. We conclude by considering the implications of our work for natural ventilation of large auditoria.
Resumo:
Silent and stable long laminar plasma jets can be generated in a rather wide range of working parameters. The laminar flow state can be maintained even if considerable parameter fluctuations exist in the laminar plasma jet or if there is an impact of laterally injected particulate matter and its carrier gas. The attractive special features of laminar plasma jets include extremely low noise level, less entrainment of ambient air, much longer and adjustable high-temperature region length, and smaller axial gradient of plasma parameters. Modeling results show that the laminar plasma jet length increases with increasing jet inlet velocity or temperature and the effect of natural convection on laminar plasma jet characteristics can be ignored, consistent with experimental observations. The large difference between laminar and turbulent plasma jet characteristics is revealed to be due to their different laws of surrounding gas entrainment. Besides the promising applications of the laminar plasma jet to remelting and cladding strengthening of the metallic surface and to thermal barrier coating preparation, it is expected that the laminar plasma jet can become a rather ideal object for the basic studies of thermal plasma science owing to the nonexistence of the complexity caused by turbulence.
Resumo:
Capillary forces are dominant in adhesive forces measured with an atomic force microscope (AFM) in ambient air, which are thought to be dependent on water film thickness, relative humidity and the free energy of the water film. In this paper, besides these factors, we study the nature of the 'pull-off' force on a variety of atmospheres as a function of the contact time. It is found that capillary forces strongly depend on the contact time. In lower relative humidity atmosphere, the adhesion force is almost independent of the contact time. However, in higher relative humidity, the adhesion force increases with the contact time. Based on the experiment and a model that we present in this paper, the growth of the liquid bridge can be seen as undergoing two processes: one is water vapour condensation; the other is the motion of the thin liquid film that is absorbed on the substrate. The experiment and the growth model presented in this paper have direct relevance to the working mechanism of AFM in ambient air.
Resumo:
There are very strong interests in improving the high-temperature wear resistance of the y-TiAl intermetallic alloy, especially when applied as tribological moving components. In this paper, microstructure, high-temperature dry sliding wear at 600 degrees C and isothermal oxidation at 1000 degrees C on ambient air of laser clad gamma/W2C/TiC composite coatings with different constitution of Ni-Cr-W-C precursor mixed powders on TiAl alloy substrates have been investigated. The results show that microstructure of the laser fabricated composite coatings possess non-equilibrium microstructure consisting of the matrix of nickel-base solid solution gamma-NiCrAl and reinforcements of TiC, W2C and M23C6 carbides. Higher wear resistance than the original TiAl alloy is achieved in the composite coatings under high-temperature wear test conditions. However, the oxidation resistance of the laser clad gamma/W2C/TiC composite coatings is deceased. The corresponding mechanisms resulting in the above behaviors of the laser clad composite coatings are discussed. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Silent and stable long laminar plasma jets can be generated in a rather wide range of working parameters. The laminar flow state can be maintained even if considerable parameter fluctuations exist in the laminar plasma jet or if there is an impact of laterally injected particulate matter and its carrier gas. The attractive special features of laminar plasma jets include extremely low noise level, less entrainment of ambient air, much longer and adjustable high-temperature region length, and smaller axial gradient of plasma parameters. Modeling results show that the laminar plasma jet length increases with increasing jet inlet velocity or temperature and the effect of natural convection on laminar plasma jet characteristics can be ignored, consistent with experimental observations. The large difference between laminar and turbulent plasma jet characteristics is revealed to be due to their different laws of surrounding gas entrainment. Besides the promising applications of the laminar plasma jet to remelting and cladding strengthening of the metallic surface and to thermal barrier coating preparation, it is expected that the laminar plasma jet can become a rather ideal object for the basic studies of thermal plasma science owing to the nonexistence of the complexity caused by turbulence.
Resumo:
In present study, effect of interfacial heat transfer with ambient gas on the onset of oscillatory convection in a liquid bridge of large Prandtl number on the ground is systematically investigated by the method of linear stability analyses. With both the constant and linear ambient air temperature distributions, the numerical results show that the interfacial heat transfer modifies the free-surface temperature distribution directly and then induces a steeper temperature gradient on the middle part of the free surface, which may destabilize the convection. On the other hand, the interfacial heat transfer restrains the temperature disturbances on the free surface, which may stabilize the convection. The two coupling effects result in a complex dependence of the stability property on the Biot number. Effects of melt free-surface deformation on the critical conditions of the oscillatory convection were also investigated. Moreover, to better understand the mechanism of the instabilities, rates of kinetic energy change and "thermal" energy change of the critical disturbances were investigated (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
O óxido nítrico (NO) constitui um dos mais importantes mediadores intra e extracelulares e tem sido descrita sua participação tanto em processos biológicos como patológicos. Nosso objetivo foi verificar se o aumento ou a diminuição do óxido nítrico apresenta um efeito benéfico na proteção do tecido pulmonar no enfisema pulmonar induzido por fumaça de cigarro em camundongos. Para tanto, utilizamos o L-NAME (inibidor do NO), a L-arginina (substrato para a formação do NO) e os comparamos com a N-acetilcisteína (utilizada no tratamento da DPOC). Foram utilizados 65 camundongos C57BL/6 machos. Cinquenta animais foram divididos em grupos controle, fumaça de cigarro (FC), fumaça de cigarro + L-NAME (FC+LN), fumaça de cigarro + L-arginina (FC+LA), fumaça de cigarro + N-acetilcisteína (FC+NAC) (n=10, por grupo). Durante sessenta dias 40 animais foram expostos a 12 cigarros comerciais por dia, 3 vezes ao dia. Os grupos controle e FC foram submetidos à gavagens orogástricas com o veículo. Os grupos FC+LN, FC+LA, FC+NAC receberam gavagens diárias de L-NAME (60 mg/kg), L-arginina (120 mg/kg) ou NAC (200 mg/kg) respectivamente. Quinze animais (n = 5, por grupo) foram expostos ao ar ambiente e tratados apenas com L-NAME, L-arginina e NAC. Realizamos a análise do perfil das células do lavado broncoalveolar após o sacrifício. O pulmão direito foi removido para as análises histológicas do alargamento dos espaços aéreos determinado pela medida do diâmetro alveolar médio (Lm) e da densidade de superfície (Sv) dos septos alveolares. Os pulmões esquerdos foram removidos e homogeneizados para a as análises da atividade enzimática (SOD, CAT e MPO) e do sistema glutationa (GSH/GSSG), para a análise dos valores de nitrito e da expressão de 4-HNE, MMP-12, NE, TIMP-1, TIMP-2. Nossos resultados apontam que o L-NAME tem uma ação voltada para a matriz extracelular (via protease-antiprotease), enquanto que a L-arginina possui uma ação voltada para os oxidantes, assim como a NAC. Porém a NAC atua aumentando os níveis de glutationa, o que interfere diretamente nos oxidantes (via oxidante-antioxidante), enquanto a L-arginina interfere aumentando o burden oxidativo concomitante a um aumento da velocidade de ação dos oxidantes o que aumenta as células inflamatórias, mas diminui seu tempo de ação permitindo uma maior proteção. Concluímos que tanto o favorecimento para a produção e liberação do NOatravés da administração da L-arginina quanto a inibição do NOpela utilização do L-NAME foi eficiente na proteção do pulmão, apesar de não terem alcançado um resultado tão bom quanto a NAC.
Resumo:
O dimensionamento de uma rede de monitoramento e controle da qualidade do ar requer o conhecimento da área onde os poluentes atmosféricos, emitidos por fontes fixas e móveis, tendem a se concentrar e os seus fenômenos de dispersão. A definição das áreas de monitoramento da poluição atmosférica na Região Metropolitana do Rio de Janeiro é um tema discutido desde o início dos anos 80 quando foram estabelecidas as bacias aéreas a partir de cartas topográficas. Este projeto consiste em pesquisa aplicada ao estabelecimento da configuração espacial e mapeamento das bacias aéreas a partir de dados digitais. Tal esforço é justificado em função do alcance dos beneficiados diretamente e à sociedade em geral, a partir do conhecimento das condições da qualidade do ar e seu comportamento ao longo do tempo. O estudo realizado se concentra na Região Metropolitana do Rio de Janeiro, com base em dados necessários para a avaliação da dinâmica das massas de ar na área de estudo e suas características para definição das novas bacias aéreas com suporte de um Sistema de Informação Geográfica (SIG). Apoiado nos dados cartográficos digitais e nos dados cadastrais das estações de monitoramento, foi projetado e implementado um SIG, em atendimento aos requisitos de mapeamento digital das bacias aéreas, da distribuição espacial das estações de monitoramento da qualidade do ar, das principais fontes de emissão de poluentes e das principais vias de circulação veicular, onde foram identificadas e mapeadas regiões com características semelhantes para diversos cenários com uso potencial do SIG. Foi criado um banco de dados georeferenciado, previamente modelado oferecendo consultas espaciais destinadas às necessidades de gestão ambiental. Com a utilização do SIG, foram identificadas áreas com deficiência no monitoramento, áreas críticas de poluição atmosférica e propostas as novas bacias aéreas delimitadas a partir dos dados digitais. O SIG se mostrou uma ferramenta eficiente para a gestão ambiental da qualidade do ar na RMRJ, pois permitiu em ambiente de escritório a representação dos elementos necessários para a avaliação da configuração espacial das bacias aéreas e proporcionou uma visualização dinâmica da distribuição espacial das estações de monitoramento nas bacias aéreas propostas.