962 resultados para IMPLANTED LINBO3


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Xenotransplantation and multivisceral transplantation are advanced therapeutic methods that still require a scientific basis. There are no experimental models of multivisceral transplantation available, particularly not the monitoring by endoscopy. Here, we describe the endoscopic features in a model of multivisceral xenotransplantation. Methods: The distal esophagus, stomach, intestine, colon, liver, pancreas, and the kidneys with a common vascular pedicle were harvested from rabbits and implanted in swine (group I, n = 9) or in rabbits (group II, n = 4). Endoscopy was performed in the stomach, jejunum, and ascending colon at four consecutive time points (immediate after surgery and 10, 90, and 180 min after reperfusion). Lesions were macroscopically graded as mild, moderate, and severe. Biopsies were taken following sacrifice at 180 min after reperfusion. Results: In group I, the stomach, jejunum, and colon manifested a progression of lesions with predominance of mild lesions after 10 min, mild to moderate lesions after 90 min, and moderate to severe lesions after 180 min. In animals from group II, endoscopy showed normal features at all time points after reperfusion. Histopathologic analysis confirmed the diagnosis of hyperacute rejection in group I. Grafts from group II animals presented normal or mild ischemic/reperfusion injury. Conclusion: All animals subjected to multivisceral xenotransplantation showed a progression of endoscopic lesions with time after transplantation, while animals subjected to allotransplantation showed no aberrations in endoscopy. We conclude that endoscopy is a useful tool in the assessment of hyperacute rejection of a xenograft.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aims to evaluate the effectiveness of the duodenojejunal bypass liner (DJBL) in the improvement of insulin resistance and reduction of cardiovascular risk among morbidly obese patients with type 2 diabetes mellitus, using the triglyceride/high-density lipoprotein (HDL) cholesterol ratio, percentage of weight loss, and glycemic control. We used the TG/HDL ratio with a cutoff value of 3.5 to identify patients with insulin resistance. The value of the initial ratio was compared with the ratio obtained 6 months after implantation to evaluate whether an improvement in insulin resistance occurred. We also evaluated the improvement of glycated hemoglobin levels and the weight loss resulted from the use of the device and correlated that with the improvement of the TG/HDL ratio. All patients implanted with the device presented a statistically significant reduction of the HbA1c levels, with most patients (70.3%) obtaining diabetes control with HbA1c levels lower than 7% at the end of the study. All patients also presented a significant weight reduction, with an average loss of 12.6% of their initial weight. We observed an important improvement in insulin resistance and metabolic syndrome, with a significant reduction of the TG/HDL ratio from 5.75 to 4.36 (p < 0.001) and 42.6% of the patients presenting a TG/HDL ratio lower than 3.5 at the end of the study. The DJBL, when used for a period of 6 months, is effective in the control of diabetes, weight loss, improvement of insulin resistance, and decrease of cardiovascular risk among morbidly obese patients with type 2 diabetes mellitus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Organ shortage impairs the proposition of multivisceral transplantation to treat multiple organ failure. Interspecies (xeno) transplantation is a valid solution for organ shortage; however, suitable models of this advance are lacking. We describe an effective model of multivisceral xenotransplantation to study hyperacute rejection. Methods: Under general anesthesia, we in block recovered the distal esophagus, stomach, small bowel, colon, liver, pancreas, spleen, and kidneys from donors and implanted heterotopically in the lower abdomen of recipients. Animals were divided into four groups: I-canine donor, swine recipient (n = 6); II - swine donor, canine recipient (n = 5); III-canine donor, canine recipient (n = 4); and IV-swine donor, swine recipient (n = 5). Groups I and 11 comprised experimental (xenotransplantation) and III and IV control groups (allotransplantation). During the experiment, we appraised recipient evolution and graft modification by sequential biopsy up to 3 h. At this time, we killed animals for autopsy (experimental end point). Results: We accomplished all experiments successfully. Every grafts attained customary appearance and convenient urine output immediately after unclamp. Around 15 min after reperfusion, xenografts achieved signs of progressive hyperacute rejection and absence of urine output. At the end of experiments we observed moderate to severe hyperacute rejection at small bowel, colon, mesenteric lymph node, liver, spleen, pancreas, and kidney, while stomach and esophagus achieved mild lesions. In contrast, allograft achieved normal or minimum ischemia/reperfusion injury and constant urine output. Conclusion: The present procedure assembles a simple and effective model to study multivisceral xenotransplantation and may ultimately spread researches toward hyperacute rejection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Progesterone, estrogen and the hormonal complex of pregnancy have been responsible for some degree of colon hypomotility in human pregnancy. Objective: To find out if estrogen, progesterone and the hormonal complex of pregnancy decrease colon myoelectric activity. Methods: The study was performed in 37 healthy female rats in which electrodes were implanted on the serosa of the proximal ascendent, distal ascendent, transverse, and descendent colon. We analyzed the records of colon myoelectric activity in vivo in five groups: control, ovariectomized, ovariectomized and treated with estrogen, ovariectomized and treated with progesterone, and pregnant rats. Results: We found a great variation in myoelectric activity in all groups studied. The mean of electric activity did not show statistical difference among the five groups, but pregnant rats had a statistically significant higher duration of maximum electric activity in all distances from the cecocolon junction. Conclusion: Pregnant rats had a statistically higher duration of maximum electric activity. If we could transpose these results to humans, this increase in duration of colon myoelectric activity could explain, in part, the slight constipation that some pregnant women have. Copyright (C) 2008 S. Karger AG, Basel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to evaluate the neural response in double-array cochlear implant as well as to describe the refractory recovery and the spread of excitation functions. In a prospective study 11 patients were implanted with the double-array cochlear implant. Neural response telemetry (NRT) was performed intra-operatively. NRT threshold could be registered in 6 of the 11 patients, at least in one electrode. The remaining five patients did not show measurable neural response intra-operatively. It was noted that although recovery and spread of excitation functions could be recorded in all the tested electrodes with measurable neural responses, the responses were shown to be different from the usual register in patients with other etiologies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A biofilm is a complex community of surface-associated cells enclosed in a polymer matrix. They attach to solid surfaces and their formation can be affected by growth conditions and co-infection with other pathogens. The presence of biofilm may protect the microorganisms from host defenses, as well as significantly reduce their susceptibility to antifungal agents. Pathogenic microbes can form biofilms on the inert surfaces of implanted devices such as catheters, prosthetic cardiac valves and intrauterine devices (IUDs). The present study was carried out to analyze the presence of biofilm on the surface of intrauterine devices in patients with recurrent vulvovaginal candidiasis, and to determine the susceptibility profile of the isolated yeasts to amphotericin B and fluconazole. Candida albicans was recovered from the IUDs and it was found to be susceptible to the antifungal agents when tested under planktonic growing conditions. These findings indicate the presence of the biofilm on the surface of the IUD as an important risk factor for recurrent vulvovaginal candidiasis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: In this study, we analyzed the time course of hemodynamic efficiency and follow-up in Fontan candidates who underwent the bidirectional Glenn procedure for staged intracardiac cavopulmonary connection (ICPC). Methods: Between 1991 and 2008, 52 patients with univentricular heart (mean age, 3.3 years; range, 2-8 years; 27 female patients [51.9%]) underwent ICPC. The cardiac malformations were as follows: tricuspid atresia, 25 cases (48.0%); common ventricle, 16 cases (30.7%); and pulmonary atresia with intact ventricular septum, 11 cases (21.1%). The intracardiac cavopulmonary procedure was indicated for all 52 cases. In 42 patients (80.7%), an intra-atrial lateral tunnel was constructed with a bovine pericardium patch. In the last 10 consecutive cases (19.3%), we performed a modified surgical technique in which we implanted an intra-atrial corrugated bovine pericardium tube sutured around the superior and inferior vena cava ostium. In all cases, a 4-mm fenestration was made to reduce the intratunnel pressure. All 52 patients had previously undergone a Glenn operation. Results: There were 2 hospital deaths (3.8%) and no recorded late deaths. During the follow-up, all patients were medicated with antiplatelet drugs. To evaluate the hemodynamic performance, we used Doppler echocardiography, computed tomography, and magnetic nuclear resonance studies. There were no prosthesis thromboses during this follow-up period. To evaluate cardiac arrhythmias, we conducted a Holter study. The last 10 patients with an intra-atrial conduit (IAC) presented with sinus rhythm and no arrhythmias during the last 4 years. The 50 surviving patients (96.1%) have been followed up for 6 to 204 months; all these patients are free of reoperation. Conclusion: The Glenn operation, which is performed at an early age, prepares the pulmonary bed to receive the ICPC. The midterm results of the intracardiac Fontan procedure seem to be good. The modified surgical procedure (IAC) can be a good alternative technique to the Fontan procedure in suitable patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study, we evaluated the acute effects of central NAC administration on baroreflex in juvenile SHR and Wistar Kyoto (WKY) rats. Male SHR and WKY rats (8 10 weeks old) were implanted with a stainless steel guide cannula into the fourth cerebral ventricle (4th V). The femoral artery and vein were cannulated for mean arterial pressure (MAP) and heart rate (HR) measurement and drug infusion, respectively. After basal MAP and HR recordings, the baroreflex was tested with a pressor dose of phenylephrine (PHE, 8 mu g/kg, bolus) and a depressor dose of sodium nitroprusside (SNP, 50 mu g/kg, bolus). Baroreflex was evaluated before, 5, 15, 30 and 60 minutes after NAC injection into the 4th V. Vehicle treatment did not change baroreflex responses in WKY and SHR. Central NAC slightly but significantly increased basal HR at 15 minutes and significantly reduced PHE-induced increase in MAP 30 and 60 minutes after NAC injection (p < 0.05) in WKY rats. In relation to SHR, NAC decreased HR range 15 and 30 minutes after its administration. In conclusion, acute NAC into the 4th V does not improve baroreflex in juvenile SHR.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction. The hippocampal formation is a specific structure in the brain where neurogenesis occurs throughout adulthood and in which the neuronal cell loss causes various demential states. The main goal of this study was to verify whether fetal neural progenitor cells (NPCs) from transgenic rats expressing green fluorescent protein (GFP) retain the ability to differentiate into neuronal cells and to integrate into the hippocampal circuitry after transplantation. Methods. NPCs were isolated from E14 (gestational age: 14 days postconception) transgenic-Lewis and wild-type Sprague-Dawley rat embryos. Wild-type and transgenic cells were expanded and induced to differentiate into a neuronal lineage in vitro. Immunocytochemical and electrophysiological analysis were performed in both groups. GFP-expressing cells were implanted into the hippocampus and recorded electrophysiologically 3 months thereafter. Immunohistochemical analysis confirmed neuronal differentiation, and the yield of neuronal cells was determined stereologically. Results. NPCs derived from wild-type and transgenic animals are similar regarding their ability to generate neuronal cells in vitro. Neuronal maturity was confirmed by immunocytochemistry and electrophysiology, with demonstration of voltage-gated ionic currents, firing activity, and spontaneous synaptic currents. GFP-NPCs were also able to differentiate into mature neurons after implantation into the hippocampus, where they formed functional synaptic contacts. Conclusions. GFP-transgenic cells represent an important tool in transplantation studies. Herein, we demonstrate their ability to generate functional neurons both in vitro and in vivo conditions. Neurons derived from fetal NPCs were able to integrate into the normal hippocampal circuitry. The high yield of mature neurons generated render these cells important candidates for restorative approaches based on cell therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bovine pericardium, for cardiac valve fabrication, was coated with either chitosan or silk fibroin film. In vitro calcification tests of coated and non coated bovine pericardium were performed in simulated body fluid solution in order to investigate potential alternatives to minimize calcification on implanted heart valves. Complementary, morphology was assessed by scanning electron microscopy - SEM; X-ray diffraction (XRD) and infrared spectroscopy (FTIR-ATR) were performed for structural characterization of coatings and biocompatibility of chitosan. Silk fibroin films were assayed by in vitro cytotoxicity and endothelial cell growth tests. Bovine pericardium coated with silk fibroin or chitosan did not present calcification during in vitro calcification tests, indicating that these biopolymeric coatings do not induce bovine pericardium calcification. Chitosan and silk fibroin films were characterized as non cytotoxic and silk fibroin films presented high affinity to endothelial cells. The results indicate that bovine pericardium coated with silk fibroin is a potential candidate for cardiac valve fabrication, since the affinity of silk fibroin to endothelial cells can be explored to induce the tissue endothelization and therefore, increase valve durability by increasing their mechanical resistance and protecting them against calcification. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Aortic valve replacement with a cryopreserved aortic homograft (CH) is an attractive alternative to bioprosthesis implantation. The aim of the study was to compare the hemodynamic performance of CH implanted with aortic root inclusion compared to prototype stentless (SS) bioprosthesis, standard stented (SD) bioprosthesis, and a native aortic valve. Methods: Hemodynamics and Doppler echocardiographic measurements such as left ventricular ejection fraction, aortic valve orifice area index (AVOAI), mean and maximal transvalvular gradients, were obtained at rest and immediately after exercise in 28 patients after aortic valve replacement with CH (n = 10), SS (n = 9), or SD (n = 9), and in a control group (CG) of 15 normal volunteers. Results: Rest and peak exercise heart rate and workload achieved were not different among the groups. Baseline AVOAI was larger for CH and CG compared to SS and SD groups (P < 0.05). Maximal and mean transvalvular pressure gradients at rest were lower for CH compared to SS and SD groups (P < 0.05), but higher than CG (P < 0,05). Conclusion: Implanted aortic CH had better hemodynamic performance than SS and SD bioprosthesis and similar to native normal aortic valves, both at rest and immediately after exercise. (ECHOCARDIOGRAPHY, Volume 26, November 2009).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims. The use of hemodialysis temporary dual-lumen catheters is often complicated by infections, which may be a significant cause of death among patients with end stage renal disease (ESRD). The aim of this study was to assess the incidence of bacteremia and bacterial colonization related to non-tunneled, non-cuffed, dual-lumen temporary catheters in patients with ESRD submitted to hemodialysis. Methods. This study included 29 patients with ESRD. After catheter implantation, patients were monitored throughout the period of catheter permanence by means of blood samples collected weekly from a peripheral vein. Bacteria were isolated and identified according to CLSI recommendations. When catheters were removed for any reason, their tips were evaluated microbiologically. Results. A total of 194 blood samples from the 29 patients implanted with 55 catheters were analyzed. Of these, 15.5% (30 samples) demonstrated bacterial growth, principally Staphylococcus epidermidis (64.5%). Twenty patients (68.9%) presented at least one positive blood culture during follow-up. The median time for catheter colonization was 18.5 days (95% CI: 16.8-30.3). Of the 55 catheters implanted, 28 (50.9%) showed bacterial colonization, corresponding to 23.4 episodes/1000 catheter/days and 9.2 episodes of bacteremia /1000 catheter/days. Fifteen of 28 catheter tips analyzed showed bacterial growth (53.5%). In 14 of these (93.3%), there was agreement between the isolates from the catheter tip and blood cultures. Of 24 episodes of positive blood cultures from 20 different patients in 17 episodes (70.8%), the patients showed no clinical signs or symptoms of bacteremia. Conclusions. The high incidence of catheter colonization, the correlation between blood and catheter tip cultures, and the occurrence of frequent cases of asymptomatic bacteremia justify the proposal of routine peripheral blood collections to monitor patients undergoing hemodialysis with temporary dual-lumen catheters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background The aim of this study was to validate a biomagnetic method (alternate current biosusceptometry, ACB) for monitoring gastric wall contractions in rats. Methods In vitro data were obtained to establish the relationship between ACB and the strain-gauge (SG) signal amplitude. In vivo experiments were performed in pentobarbital-anesthetized rats with SG and magnetic markers previously implanted under the gastric serosa or after ingestion of magnetic material. Gastric motility was quantified from the tracing amplitudes and frequency profiles obtained by Fast Fourier Transform. Key Results The correlation between in vitro signal amplitudes was strong (R = 0.989). The temporal cross-correlation coefficient between the ACB and SG signal amplitude was higher (P < 0.0001) in the postprandial (88.3 +/- 9.1 V) than in the fasting state (31.0 +/- 16.9 V). Irregular signal profiles, low contraction amplitudes, and smaller signal-to-noise ratios explained the poor correlation between techniques for fasting-state recordings. When a magnetic material was ingested, there was also strong correlation in the frequency and signal amplitude and a small phase-difference between the techniques. The contraction frequencies using ACB were 0.068 +/- 0.007 Hz (postprandial) and 0.058 +/- 0.007 Hz (fasting) (P < 0.002) and those using SG were 0.066 +/- 0.006 Hz (postprandial) and 0.059 +/- 0.008 Hz (fasting) (P < 0.005). Conclusions & Inferences In summary, ACB is reliable for monitoring gastric wall contractions using both implanted and ingested magnetic materials, and may serve as an accurate and sensitive technique for gastrointestinal motility studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The brain noradrenergic system has been implicated in the expression of defensive behaviors elicited by acute stress. The dorsal periaqueductal gray area (dPAG) is a key structure involved in the behavioral and cardiovascular responses elicited by fear and anxiety situations. Although there are noradrenergic terminals in the dPAG, few studies have investigated the role of noradrenaline (NA) in the dPAG on anxiety modulation. The aim of this study was to evaluate the effect of NA microinjection into the dPAG of rats subjected to two animal models of anxiety, the elevated plus-maze and the Vogel conflict test. Male Wistar rats implanted with a guide cannula aimed at the dPAG received microinjections of NA (3, 15, or 45 nmol/0.05 mu l) or artificial cerebral spinal fluid into the dPAG immediately before being exposed to the elevated plus-maze or the Vogel conflict test. NA increased the exploration of the open arms and the number of enclosed arm entries in the elevated plus-maze. The increase in open arm exploration remained significant after being subjected to an analysis of covariance using the latter variable as covariate. Moreover, the NA microinjection into the dPAG did not increase general exploratory activity of animals subjected to the open-field test, indicating that the increase in open arm exploration cannot be attributed to a nonspecific increase in exploratory activity. In the Vogel test, the NA microinjection into the dPAG increased the number of punished licks without changing the number of nonpunished licks or interfering with the tail-flick test. The results, therefore, indicate that the NA microinjection into the dPAG produces anxiolytic-like effects, suggesting its possible involvement in the anxiety modulation. Behavioural Pharmacology 20:252-259 (C) 2009 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The ventral medial prefrontal cortex (vMPFC) has direct connections to subcortical, diencephalic and brainstem structures that have been closely related to depression. However, studies aimed at investigating the role of the vMPFC in the neurobiology of depression have produced contradictory results. Moreover, the precise involvement of vMPFC anatomic subdivisions, the prelimbic(PL) and the infralimbic (IL) cortices, in regulating depressive-like behavior have been poorly investigated. The forced swimming test (FST) is a widely employed animal model aimed at detecting antidepressant-like effects. Therefore, to further investigate a possible involvement of the vMFPC in depressive-like behavior, rats bilaterally implanted with cannulae aimed at the PL or IL prefrontal cortices were submitted to 15 min of forced swimming (pre-test) followed, 24 h later, by a 5-min swimming session (test), where immobility time was registered. Synaptic transmission in these regions was temporarily inhibited using local microinjection of cobalt chloride at different periods of the experimental procedure (before or after the pre-test or before the test). PL inactivation decreased immobility time independently of the time of the injection. In the IL inactivation induced a significant antidepressant-like effect when performed immediately before the pre-test or before the test, but not after the pre-test. These results suggest that activation of the vMPFC is important for the behavioral changes observed in rats submitted to the FST. They further indicate that, although both the PL and IL cortices are involved in these effects, they may play different roles. (C) 2010 Elsevier B.V. All rights reserved.