844 resultados para Hip Fractures
Resumo:
Introduction: In an attempt to reduce stress shielding in the proximal femur multiple new shorter stem design have become available. We investigated the load to fracture of a new polished tapered cemented short stem in comparison to the conventional polished tapered Exeter stem. Method: A total of forty-two stems, twenty-one short stems and twenty-one conventional stems both with three different offsets were cemented in a composite sawbone model and loaded to fracture. Results: study showed that femurs will break at a significantly lower load to failure with a shorter compared to conventional length Exeter stem. Conclusion: This Both standard and short stem design are safe to use as the torque to failure is 7–10 times as much as the torques seen in activities of daily living.
Resumo:
Introduction Clinical guidelines for the treatment of chronic low back pain suggest the use of supervised exercise. Motor control (MC) based exercise is widely used within clinical practice but its efficacy is equivalent to general exercise therapy. MC exercise targets the trunk musculature. Considering the mechanical links between the hip, pelvis, and lumbar spine, surprisingly little focus has been on investigating the contribution of the hip musculature to lumbopelvic support. The purpose of this study is to compare the efficacy of two exercise programs for the treatment of non-specific low back pain (NSLBP). Methods Eighty individuals aged 18-65 years of age were randomized into two groups to participate in this trial. The primary outcome measures included self-reported pain intensity (0-100mm VAS) and percent disability (Oswestry Disability Index V2). Bilateral measures of hip strength (N/kg) and two dimensional frontal plane mechanics (º) were the secondary outcomes. Outcomes were measured at baseline and following a six-week home based exercise program including weekly sessions of real-time ultrasound imaging. Results Within group comparisons revealed clinically meaningful reductions in pain for both groups. The MC exercise only (N= 40, xˉ =-20.9mm, 95%CI -25.7, -16.1) and the combined MC and hip exercise (N= 40, xˉ = -24.9mm, 95%CI -30.8, -19.0). There was no statistical difference in the change of pain (xˉ =-4.0mm, t= -1.07, p=0.29, 95%CI -11.5, 3.5) or disability (xˉ =-0.3%, t=-0.19, p=0.85, 95%CI -11.5, 3.5) between groups. Conclusion Both exercise programs had similar and positive effects on NSLBP which support the use of the home based exercise programs with weekly supervised visits. However, the addition of specific hip strengthening exercises to a MC based exercise program did not result in significantly greater reductions in pain or disability. Trial Registration NCTO1567566 Funding: Worker’s Compensation Board Alberta Research Grant.
Resumo:
Objective: To investigate limb loading and dynamic stability during squatting in the early functional recovery of total hip arthroplasty (THA) patients. Design: Cohort study Setting: Inpatient rehabilitation clinic. Participants: A random sample of 61 THA patients (34♂/27♀; 62±9 yrs, 77±14 kg, 174±9 cm) was assessed twice, 13.2±3.8 days (PRE) and 26.6±3.3 days post-surgery (POST), and compared with a healthy reference group (REF) (22♂/16♀; 47±12yrs; 78±20kg; 175±10cm). Interventions: THA patients received two weeks of standard in-patient rehabilitation. Main Outcome Measure(s): Inter-limb vertical force distribution and dynamic stability during the squat maneuver, as defined by the root mean square (RMS) of the center of pressure in antero-posterior and medio-lateral directions, of operated (OP) and non-operated (NON)limbs. Self-reported function was assessed via FFb-H-OA 2.0 questionnaire. Results: At PRE, unloading of the OP limb was 15.8% greater (P<.001, d=1.070) and antero-posterior and medio-lateral center of pressure RMS were 30-34% higher in THA than REF P<.05). Unloading was reduced by 12.8% towards a more equal distribution from PRE to POST (P<.001, d=0.874). Although medio-lateral stability improved between PRE and POST (OP: 14.8%, P=.024, d=0.397; NON: 13.1%, P=.015, d=0.321), antero-posterior stability was not significantly different. Self-reported physical function improved by 15.8% (P<.001, d=0.965). Conclusion(s): THA patients unload the OP limb and are dynamically more unstable during squatting in the early rehabilitation phase following total hip replacement than healthy adults. Although loading symmetry and medio-lateral stability improved to the level of healthy adults with rehabilitation, antero-posterior stability remained impaired. Measures of dynamic stability and load symmetry during squatting provide quantitative information that can be used to clinically monitor early functional recovery from THA.
Resumo:
Problem addressed Wrist-worn accelerometers are associated with greater compliance. However, validated algorithms for predicting activity type from wrist-worn accelerometer data are lacking. This study compared the activity recognition rates of an activity classifier trained on acceleration signal collected on the wrist and hip. Methodology 52 children and adolescents (mean age 13.7 +/- 3.1 year) completed 12 activity trials that were categorized into 7 activity classes: lying down, sitting, standing, walking, running, basketball, and dancing. During each trial, participants wore an ActiGraph GT3X+ tri-axial accelerometer on the right hip and the non-dominant wrist. Features were extracted from 10-s windows and inputted into a regularized logistic regression model using R (Glmnet + L1). Results Classification accuracy for the hip and wrist was 91.0% +/- 3.1% and 88.4% +/- 3.0%, respectively. The hip model exhibited excellent classification accuracy for sitting (91.3%), standing (95.8%), walking (95.8%), and running (96.8%); acceptable classification accuracy for lying down (88.3%) and basketball (81.9%); and modest accuracy for dance (64.1%). The wrist model exhibited excellent classification accuracy for sitting (93.0%), standing (91.7%), and walking (95.8%); acceptable classification accuracy for basketball (86.0%); and modest accuracy for running (78.8%), lying down (74.6%) and dance (69.4%). Potential Impact Both the hip and wrist algorithms achieved acceptable classification accuracy, allowing researchers to use either placement for activity recognition.
Resumo:
Objectives To compare the efficacy of two exercise programs in reducing pain and disability for individuals with non-specific low back pain and to examine the underlying mechanical factors related to pain and disability for individuals with NSLBP. Design A single-blind, randomized controlled trial. Methods: Eighty participants were recruited from eleven community-based general medical practices and randomized into two groups completing either a lumbopelvic motor control or a combined lumbopelvic motor control and progressive hip strengthening exercise therapy program. All participants received an education session, 6 rehabilitation sessions including real time ultrasound training, and a home based exercise program manual and log book. The primary outcomes were pain (0-100mm visual analogue scale), and disability (Oswestry Disability Index V2). The secondary outcomes were hip strength (N/kg) and two-dimensional frontal plane biomechanics (°) measure during the static Trendelenburg test and while walking. All outcomes were measured at baseline and at 6-week follow up. Results There was no statistical difference in the change in pain (xˉ = -4.0mm, t= -1.07, p =0.29, 95%CI -11.5, 3.5) or disability (xˉ = -0.3%, t= -0.19, p =0.85, 95%CI -3.5, 2.8) between groups. Within group comparisons revealed clinically meaningful reductions in pain for both Group One (xˉ =-20.9mm, 95%CI -25.7, -16.1) and Group Two (xˉ =-24.9, 95%CI -30.8, -19.0). Conclusion Both exercise programs had similar efficacy in reducing pain. The addition of hip strengthening exercises to a motor control exercise program does not appear to result in improved clinical outcome for pain for individuals with non-specific low back pain.
Resumo:
The prevalence of osteoporosis is expected to increase with the ageing of the world’s population. This article reviews the epidemiology, risk factors and health burden of osteoporosis. In the Global Burden of Disease (GBD) Study 2005, osteoporosis is studied as a risk factor for fracture by considering the bone-mineral-density (BMD) measurement as the continuous exposure variable. We have performed a systematic review seeking population-based studies with BMD data measured by dual-X-ray absorptiometry (DXA). The femoral neck was selected as the unique location and all values were converted into Hologic® to enable inclusion of worldwide data for analysis. Provisional results on mean BMD values for different world regions are shown in age breakdowns for males and females 50 years or over, as well as mean T-scores using the young, white, female reference of National Health and Nutrition Examination Survey (NHANES) III. Results show remarkable geographical differences and a time trend towards improvement of the BMD values in Asian and European populations.
Resumo:
Joint moments and joint powers are widely used to determine the effects of rehabilitation programs and prosthetic components (e.g., alignments). A complementary analysis of the 3D angle between joint moment and joint angular velocity has been proposed to assess whether the joints are predominantly driven or stabilized.
Resumo:
Study Design: Comparative analysis Background: Calculations of lower limbs kinetics are limited by floor-mounted force-plates. Objectives: Comparison of hip joint moments, power and mechanical work on the prosthetic limb of a transfemoral amputee calculated by inverse dynamics using either the ground reactions (force-plates) or knee reactions (transducer). Methods: Kinematics, ground reactions and knee reactions were collected using a motion analysis system, two force-plates and a multi-axial transducer mounted below the socket, respectively. Results: The inverse dynamics using ground reactions under-estimated the peaks of hip energy generation and absorption occurring at 63 % and 76 % of the gait cycle (GC) by 28 % and 54 %, respectively. This method over-estimated a phase of negative work at the hip (from 37 %GC to 56 %GC) by 24%. It under-estimated the phases of positive (from 57 %GC to 72 %GC) and negative (from 73 %GC to 98 %GC) work at the hip by 11 % and 58%, respectively. Conclusions: A transducer mounted within the prosthesis has the capacity to provide more realistic kinetics of the prosthetic limb because it enables assessment of multiple consecutive steps and a wide range of activities without issues of foot placement on force-plates. CLINICAL RELEVANCE The hip is the only joint that an amputee controls directly to set in motion the prosthesis. Hip joint kinetics are associated with joint degeneration, low back pain, risks of fall, etc. Therefore, realistic assessment of hip kinetics over multiple gait cycles and a wide range of activities is essential.
Can larger-bodied cemented femoral components reduce periprosthetic fractures? A biomechanical study
Resumo:
Introduction: The risk for late periprosthetic femoral fractures is higher in patients treated for a neck of femur fracture compared to osteoarthritis. It has been hypothesised that osteopenia and consequent decreased stiffness of the proximal femur are responsible for this. We investigated whether a femoral component with a bigger body would increase the torque to failure in a biaxially loaded composite Sawbone model. Material and methods: A biomechanical bone analogue was used. Two different body sizes (Exeter 44-1 vs 44-4) of a polished tapered cemented femoral stem were implanted by an experienced surgeon in 7 bone analogues each and internally rotated at 40°/s until failure. Torque to fracture and fracture energy were measured using a biaxial materials testing device (Instron 8874, MI, USA). The data were non-parametric and therefore tested with the Mann-Whitney U-test. Results: The median torque to fracture was 156.7 Nm (IQR 19.7) for the 44-1 stem and 237.1 Nm (IQR 52.9) for the 44-4 stem (p=0.001). The median fracture energy was 8.5J (IQR 7.3) for the 44-1 stem and 19.5J (IQR 8.8) for the 44-4 stem (p=0.014). Conclusions: The use of a large body polished tapered cemented stems for neck of femur fractures increases the torque to failure in a biomechanical model and therefore is likely to reduce late periprosthetic fracture risk in this vulnerable cohort.
Resumo:
Had it been published a decade earlier, Hip-hop Japan might have been cited as a good example of the kind of multi-sited ethnography George Marcus (1998) proposes. Hip-hop Japan is a critical study of cultural globalisation. It presents as much theoretical interpretation, discussions of Japanese popular culture in general, and reviews of formulations of the Japanese self by Japanese scholars, as it does of Japanese hip-hop per se. In fact, the latter is relatively thinly described, as Condry’s project is to demonstrate how Japanese hip-hop’s particularities are made up from a mix of US hip-hop, Japanese modes of fandom, contestatory uses of the Japanese language and the specific logics of the Japanese popular music recording industry. The book journeys into these worlds as much as it does into the world of Japanese hip-hop.
Resumo:
Researchers have postulated that reduced hip-abductor muscle strength may have a role in the progression of knee osteoarthritis by increasing the external knee-adduction moment. However, the relationship between hip-abductor strength and frontal-plane biomechanics remains unclear. To experimentally reduce hip-abduction strength and observe the subsequent changes in frontal-plane biomechanics. Descriptive laboratory study. Research laboratory. Eight healthy, recreationally active men (age = 27 ± 6 years, height = 1.75 ± 0.11 m, mass = 76.1 ± 10.0 kg). All participants underwent a superior gluteal nerve block injection to reduce the force output of the hip-abductor muscle group. Maximal isometric hip-abduction strength and gait biomechanical data were collected before and after the injections. Gait biomechanical variables collected during walking consisted of knee- and hip-adduction moments and impulses and the peak angles of contralateral pelvic drop, hip adduction, and ipsilateral trunk lean. Hip-abduction strength was reduced after the injection (P = .001) and remained lower than baseline values at the completion of the postinjection gait data collection (P = .02). No alterations in hip- or knee-adduction moments (hip: P = .11; knee: P = .52) or impulses (hip: P = .16; knee: P = .41) were found after the nerve block. Similarly, no changes in angular kinematics were observed for contralateral pelvic drop (P = .53), ipsilateral trunk lean (P = .78), or hip adduction (P = .48). A short-term reduction in hip-abductor strength was not associated with alterations in the frontal-plane gait biomechanics of young, healthy men. Further research is needed to determine whether a similar relationship is true in older adults with knee osteoarthritis.
Resumo:
Background After being discharged from hospital following the acute management of a fragility fracture, older adults may re-present to hospital emergency departments in the post-discharge period. Early re-presentation to hospital, which includes hospital readmissions, and emergency department presentations without admission, may be considered undesirable for individuals, hospital institutions and society. The identification of modifiable risk factors for hospital re-representation following initial fracture management may prove useful for informing policy or practice initiatives that seek to minimise the need for older adults to re-present to hospital early after they have been discharged from their initial inpatient care. The purpose of this systematic review is to identify correlates of hospital re-presentation in older patients who have been discharged from hospital following clinical management of fragility fractures. Methods/Design The review will follow the PRISMA-P reporting guidelines for systematic reviews. Four electronic databases (Pubmed, CINAHL, Embase, and Scopus) will be searched. A suite of search terms will identify peer-reviewed articles that have examined the correlates of hospital re-presentation in older adults (mean age of 65 years or older) who have been discharged from hospital following treatment for fragility fractures. The Effective Public Health Practice Project Quality Assessment Tool for Quantitative Studies will be used to assess the quality of the studies. The strength of evidence will be assessed through best evidence synthesis. Clinical and methodological heterogeneity across studies are likely to impede meta-analyses. Discussion The best evidence synthesis will outline correlates of hospital re-presentations in this clinical group. This synthesis will take into account potential risks of bias for each study, while permitting inclusion of findings from a range of quantitative study designs. It is anticipated that findings from the review will be useful in identifying potentially modifiable risk factors that have relevance in policy, practice and research priorities to improve the management of patients with fragility fractures. Systematic Review Registration PROSPERO CRD42015019379
Resumo:
Osteoporotic fracture is a major cause of morbidity and mortality worldwide. Low bone mineral density (BMD) is a major predisposing factor to fracture and is known to be highly heritable. Site-, gender-, and age-specific genetic effects on BMD are thought to be significant, but have largely not been considered in the design of genome-wide association studies (GWAS) of BMD to date. We report here a GWAS using a novel study design focusing on women of a specific age (postmenopausal women, age 55-85 years), with either extreme high or low hip BMD (age- and gender-adjusted BMD z-scores of +1.5 to +4.0, n = 1055, or -4.0 to -1.5, n = 900), with replication in cohorts of women drawn from the general population (n = 20,898). The study replicates 21 of 26 known BMD-associated genes. Additionally, we report suggestive association of a further six new genetic associations in or around the genes CLCN7, GALNT3, IBSP, LTBP3, RSPO3, and SOX4, with replication in two independent datasets. A novel mouse model with a loss-of-function mutation in GALNT3 is also reported, which has high bone mass, supporting the involvement of this gene in BMD determination. In addition to identifying further genes associated with BMD, this study confirms the efficiency of extreme-truncate selection designs for quantitative trait association studies. © 2011 Duncan et al.