1000 resultados para Highway communications


Relevância:

20.00% 20.00%

Publicador:

Resumo:

[ES]Este Trabajo de Fin de Grado consiste en diseñar y desarrollar una solución de resilient communications para su uso en entornos de movilidad, en concreto, en entornos vehiculares. Se diseñara una solución que consiste en añadir soporte de múltiples vías de comunicación entre dos extremos para el protocolo de movilidad HIP. Este trabajo consiste en buscar una solución de resilient communications, ya que buscamos como objetivo principal aumentar la disponibilidad del sistema de comunicaciones, es decir, aumentar aspectos tales como la tolerancia a fallos y contra ataques de seguridad, concretamente contra ataques contra la disponibilidad.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An article in the Engineering News-Record for March 30, 1923, describes a new concrete arch bridge across the Connecticut River between Springfield and West Springfield, Mass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The gain of a transmitter for intersatellite communications is closely related to the performance of all the links. We calculate the transmitter telescope's gain with the help of the rigorous scalar diffraction theory and equivalent optical layout method. Furthermore, a comparison is performed with the conventional imaging method. The results show that the stop inside the telescope can affect the gain of the telescope. Finally, the gain is calculated under the condition of the aberrations. We find that different aberrations cause different effects. (C) 2006 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The gain of a transmitter for intersatellite communications is closely related to the performance of all the links. We calculate the transmitter telescope's gain with the help of the rigorous scalar diffraction theory and equivalent optical layout method. Furthermore, a comparison is performed with the conventional imaging method. The results show that the stop inside the telescope can affect the gain of the telescope. Finally, the gain is calculated under the condition of the aberrations. We find that different aberrations cause different effects. (C) 2006 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The span of the bridge was assumed as 100 feet. The type of bridge used is the timber Howe Truss. The height of truss was taken as 20 feet between center lines of top and bottom chords. The width was taken as 18 feet center to center of trusses. The truss was divided up into five panels 20 feet long.

It was designed according to the "General Specifications for Steel Highway Bridges" by Ketchum. For the live load for the floor and its supports, a load of 80 pounds per square foot of total floor surface or a 15 ton traction engine with axles 10 feet centers and 6 feet gage, two thirds of load to be carried by rear axles.

For the truss a load of 75 pounds per square foot of floor surface.

For the wind load the bottom lateral bracing is to be designed to resist a lateral wind load of 300 pounds per foot of span; 150 pounds of this to be treated as a moving load.

The top lateral bracing is to be designed to resist a lateral wind force of 150 pounds per foot of span.

The timber to be used in the bridge is to be Douglas fir.

The unit stresses used for timber are those of the American Railway Engineering Association.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Smart Grids are becoming a reality all over the world. Nowadays, the research efforts for the introduction and deployment of these grids are mainly focused on the development of the field of Smart Metering. This emerging application requires the use of technologies to access the significant number of points of supply (PoS) existing in the grid, covering the Low Voltage (LV) segment with the lowest possible costs. Power Line Communications (PLC) have been extensively used in electricity grids for a variety of purposes and, of late, have been the focus of renewed interest. PLC are really well suited for quick and inexpensive pervasive deployments. However, no LV grid is the same in any electricity company (utility), and the particularities of each grid evolution, architecture, circumstances and materials, makes it a challenge to deploy Smart Metering networks with PLC technologies, with the Smart Grid as an ultimate goal. This paper covers the evolution of Smart Metering networks, together with the evolution of PLC technologies until both worlds have converged to project PLC-enabled Smart Metering networks towards Smart Grid. This paper develops guidelines over a set of strategic aspects of PLC Smart Metering network deployment based on the knowledge gathered on real field; and introduces the future challenges of these networks in their evolution towards the Smart Grid.