968 resultados para High-range water reducer


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Concern about the neurotoxicity of lead, particularly in infants and young children, has led to a revision of blood lead levels which are considered to involve an acceptable level of human exposure. Drinking water guidelines have also been reviewed in order to reduce this source of population exposure to lead. In the last 20 years, guidelines have been reduced from 100 to 50 to 10 mu g/litre. Lead in tap water used to be a major public health problem in Glasgow because of the high prevalence of houses with lead service pipes, the low pH of the public water supply and the resulting high levels of lead in water used for public consumption. Following two separate programmes of water treatment, involving the addition of lime and, a decade later, lime supplemented with orthophosphate, it is considered that maximal measures have been taken to reduce lead exposure by chemical treatment of the water supply. Any residual problem of public exposure would require large scale replacement of lead service pipes. In anticipation of the more stringent limits for lead in drinking water, we set out to measure current lead exposure From tap water in the population of Glasgow served by the Loch Katrine water supply. to compare the current situation with 12 years previously and to assess the public health implications of different limits. The study was based on mothers of young children since maternal blood lead concentrations and the domestic water that mothers use to prepare bottle feeds are the principal sources of foetal and infant lead exposure. An estimated 17% of mothers lived in households with tap water lead concentrations of 10 mu g/litre (the WHO guideline) or above in 1993 compared with 49% in 1981. Mean maternal blood lead concentrations fell by 69% in 12 years. For a given water lead concentration, maternal blood lead concentrations were 67% lower. The mean maternal blood lead concentration was 3.7 mu g/litre in the population at large, compared with 3.3 mu g/litre in households with negligible or absent tap water lead. Nevertheless, between 63% and 76% of cases of mothers with blood lead concentrations of 10 mu g/dl or above were attributable to tap water lead. The study found that maternal blood lead concentrations were well within limits currently considered safe for human health. About 15% of infants may be exposed via bottle feeds to tap water lead concentrations that exceed the WHO guideline of 10 mu g/litre. In the context of the health and social problems which affect the well-being and development of infants and children in Glasgow, however, current levels of lend exposure are considered to present a relatively minor health problem. (C) 2000 Elsevier Science Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

.:Abstract-Objective: Bioelectrical impedance analysis (BIA) is widely used as bedside assessment of body composition. Body cell mass (BCM) and intracellular water (ICW) are clinically important body compartments. Estimates of ICW obtained from BIA by different calculation approaches were compared to a reference method in male HIV-infected patients. Patients: Representative subsample of clinically stable HIV-infected outpatients, consisting of 42 men with a body mass index of 22.4 +/- 3.8 kg/m(2) (range, 13-31 kg/m(2)). Methods: Total body potassium was assessed in a whole body counter, and compared to 50 kHz mono-frequency BIA and multifrequency bioelectrical impedance spectroscopy. Six different prediction equations for ICW from BIA data were applied. Methods were compared by the Bland-Altman method. Results: BIA-derived ICW estimates explained 58% to 73% of the observed variance in ICW (TBK), but limits of confidence were wide (-16.6 to +18.2% for the best method). BIA overestimated low ICW (TBK) and underestimated high ICW (TBK) when normalized for weight or height. Mono- and multifrequency BIA were not different in precision but population-specific equations tended to narrower confidence limits. Conclusion: BIA is an unreliable method to estimate ICW in this population, in contrast to the better established estimation of total body water and extracellular water. Potassium depletion in severe malnutrition may contribute to this finding but a major part of the residual between methods remains unexplained. (C) 2000 Harcourt Publishers Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The measurement of organic carbon in soils has traditionally used dichromate oxidation procedures including the Wakley and Black and the Heanes methods. The measurement of carbon in soils by high temperature combustion is now widely used providing a rapid automated procedure without the use of toxic chemicals. This procedure however measures total carbon thus requiring some means of correction for soil samples containing carbonate and charcoal forms of carbon. This paper examines the effects of known additions of charcoal to a range of soil types on the results obtained by the Walkley and Black, Heanes and combustion methods. The results show, that while the charcoal carbon does not react under Walkley and Black conditions, some proportion does so with the Heanes method. A comparison of six Australian Soil and Plant Analysis Council reference soil samples by the three methods showed good agreement between the Heanes method, the combustion method and only slightly lower recoveries by the Walkley and Black procedure. Carbonate carbon will cause an overestimation of soil organic carbon by the combustion method thus requiring a separate determination of carbonate carbon to be applied as a correction. This work shows that a suitable acid pre-treatment of alkaline soils in the sample boats followed by a drying step eliminates the carbonate carbon prior to combustion and the need for an additional measurement. The measurement of carbon in soils by high temperature combustion in an oxygen atmosphere has been shown to be a rapid and reliable method capable of producing results in good agreement with one of the established dichromate oxidation procedures.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The assumption in analytical solutions for flow from surface and buried point sources of an average water content, (θ) over bar, behind the wetting front is examined. Some recent work has shown that this assumption fitted some field data well. Here we calculated (θ) over bar using a steady state solution based on the work by Raats [1971] and an exponential dependence of the diffusivity upon the water content. This is compared with a constant value of (θ) over bar calculated from an assumption of a hydraulic conductivity at the wetting front of 1 mm day(-1) and the water content at saturation. This comparison was made for a wide range of soils. The constant (θ) over bar generally underestimated (θ) over bar at small wetted radii and overestimated (θ) over bar at large radii. The crossover point between under and overestimation changed with both soil properties and flow rate. The largest variance occurred for coarser texture soils at low-flow rates. At high-flow rates in finer-textured soils the use of a constant (θ) over bar results in underestimation of the time for the wetting front to reach a particular radius. The value of (θ) over bar is related to the time at which the wetting front reaches a given radius. In coarse-textured soils the use of a constant value of (θ) over bar can result in an error of the time when the wetting front reaches a particular radius, as large as 80% at low-flow rates and large radii.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Recent advances in the control of molecular engineering architectures have allowed unprecedented ability of molecular recognition in biosensing, with a promising impact for clinical diagnosis and environment control. The availability of large amounts of data from electrical, optical, or electrochemical measurements requires, however, sophisticated data treatment in order to optimize sensing performance. In this study, we show how an information visualization system based on projections, referred to as Projection Explorer (PEx), can be used to achieve high performance for biosensors made with nanostructured films containing immobilized antigens. As a proof of concept, various visualizations were obtained with impedance spectroscopy data from an array of sensors whose electrical response could be specific toward a given antibody (analyte) owing to molecular recognition processes. In addition to discussing the distinct methods for projection and normalization of the data, we demonstrate that an excellent distinction can be made between real samples tested positive for Chagas disease and Leishmaniasis, which could not be achieved with conventional statistical methods. Such high performance probably arose from the possibility of treating the data in the whole frequency range. Through a systematic analysis, it was inferred that Sammon`s mapping with standardization to normalize the data gives the best results, where distinction could be made of blood serum samples containing 10(-7) mg/mL of the antibody. The method inherent in PEx and the procedures for analyzing the impedance data are entirely generic and can be extended to optimize any type of sensor or biosensor.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectives: To assess the accuracy of reporting from both a diet history and food record and identify some of the characteristics of more accurate reporters in a group of healthy adult volunteers for an energy balance study. Design: Prospective measurements in free-living people. Setting: Wollongong, Australia. Subjects: Fifteen healthy volunteers (seven male, eight female; aged 22 -59 y; body mass index (BMI) 19 - 33 kg/m(2)) from the local community in the city of Wollongong, Australia. Interventions: Measurement of energy intake via diet history interview and 7 day food records, total energy expenditure by the doubly labelled water technique over 14 days, physical activity by questionnaire, and body fat by dual-energy X-ray absorptiometry. Results: Increased misreporting of energy intake was associated with increased energy expenditure (r = 0.90, P < 0.0001, diet history; r(s)=0.79, P=0.0005, food records) but was not associated with age, sex, BMI or body fat. Range in number of recorded dinner foods correlated positively with energy expenditure (r(s)=0.63, P=0.01) and degree of misreporting (r(s)=0.71, P=0.003, diet history; r(s)=0.63, P=0.01, food records). Variation in energy intake at dinner and over the whole day identified by the food records correlated positively with energy expenditure (r=0.58, P = 0.02) and misreporting on the diet history (r=0.62, P=0.01). Conclusions: Subjects who are highly active or who have variable dietary and exercise behaviour may be less accurate in reporting dietary intake. Our findings indicate that it may be necessary to screen for these characteristics in studies where accuracy of reporting at an individual level is critical. Sponsorship: The study was supported in part by Australian Research Council funds made available through the University of Wollongong.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Paracetamol is among the most worldwide consumed pharmaceuticals. Although its occurrence in the environment is well documented, data about the presence of its metabolites and transformation products is very scarce. The present work describes the development of an analytical method for the simultaneous determination of paracetamol, its principal metabolite (paracetamol-glucuronide) and its main transformation product (p-aminophenol) based on solid phase extraction (SPE) and high performance liquid chromatography coupled to diode array detection (HPLC-DAD). The method was applied to analysis of river waters, showing to be suitable to be used in routine analysis. Different SPE sorbents were compared and the use of two Oasis WAX cartridges in tandem proved to be the most adequate approach for sample clean up and pre-concentration. Under optimized conditions, limits of detection in the range 40–67 ng/L were obtained, as well as mean recoveries between 60 and 110% with relative standard deviations (RSD) below 6%. Finally, the developed SPE-HPLC/DAD method was successfully applied to the analysis of the selected compounds in samples from seven rivers located in the north of Portugal. Nevertheless all the compounds were detected, it was the first time that paracetamol-glucuronide was found in river water at concentrations up to 3.57 μg/L.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Cyanobacteria deteriorate the water quality and are responsible for emerging outbreaks and epidemics causing harmful diseases in Humans and animals because of their toxins. Microcystin-LR (MCT) is one of the most relevant cyanotoxin, being the most widely studied hepatotoxin. For safety purposes, the World Health Organization recommends a maximum value of 1 μg L−1 of MCT in drinking water. Therefore, there is a great demand for remote and real-time sensing techniques to detect and quantify MCT. In this work a Fabry–Pérot sensing probe based on an optical fibre tip coated with a MCT selective thin film is presented. The membranes were developed by imprinting MCT in a sol–gel matrix that was applied over the tip of the fibre by dip coating. The imprinting effect was obtained by curing the sol–gel membrane, prepared with (3-aminopropyl) trimethoxysilane (APTMS), diphenyl-dimethoxysilane (DPDMS), tetraethoxysilane (TEOS), in the presence of MCT. The imprinting effect was tested by preparing a similar membrane without template. In general, the fibre Fabry–Pérot with a Molecular Imprinted Polymer (MIP) sensor showed low thermal effect, thus avoiding the need of temperature control in field applications. It presented a linear response to MCT concentration within 0.3–1.4 μg L−1 with a sensitivity of −12.4 ± 0.7 nm L μg−1. The corresponding Non-Imprinted Polymer (NIP) displayed linear behaviour for the same MCT concentration range, but with much less sensitivity, of −5.9 ± 0.2 nm L μg−1. The method shows excellent selectivity for MCT against other species co-existing with the analyte in environmental waters. It was successfully applied to the determination of MCT in contaminated samples. The main advantages of the proposed optical sensor include high sensitivity and specificity, low-cost, robustness, easy preparation and preservation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION: Leptospirosis is a re-emerging zoonotic disease of humans and animals worldwide. The disease is caused by pathogenic species of the genus Leptospira. These organisms are maintained in nature via chronic renal infection of carrier animals, which excrete the organisms in their urine. Humans become infected through direct or indirect exposure to infected animals and their urine or through contact with contaminated water and soil. This study was conducted to investigate Leptospira infections as a re-emerging zoonosis that has been neglected in Egypt. METHODS: Samples from 1,250 animals (270 rats, 168 dogs, 625 cows, 26 buffaloes, 99 sheep, 14 horses, 26 donkeys and 22 camels), 175 human contacts and 45 water sources were collected from different governorates in Egypt. The samples were collected from different body sites and prepared for culture, PCR and the microscopic agglutination test (MAT). RESULTS: The isolation rates of Leptospira serovars were 6.9%, 11.3% and 1.1% for rats, dogs and cows, respectively, whereas the PCR results revealed respective detection rates of 24%, 11.3% and 1.1% for rats, dogs and cows. Neither the other examined animal species nor humans yielded positive results via these two techniques. Only six Leptospira serovars (Icterohaemorrhagiae, Pomona, Canicola, Grippotyphosa, Celledoni and Pyrogenes) could be isolated from rats, dogs and cows. Moreover, the seroprevalence of leptospiral antibodies among the examined humans determined using MAT was 49.7%. CONCLUSIONS: The obtained results revealed that rats, dogs and cows were the most important animal reservoirs for leptospirosis in Egypt, and the high seroprevalence among human contacts highlights the public health implications of this neglected zoonosis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Several suction–water-content (s-w) calibrations for the filter paper method (FPM) used for soil-suction measurement have been published. Most of the calibrations involve a bilinear function (i.e., two different equations) with an inflection point occurring at 60 kPawater content range of 30 %

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to evaluate tetracycline antibiotic (TA) removal from contaminated water by Moringa oleifera seed preparations. The composition of synthetic water approximate river natural contaminated water and TA simulated its presence as an emerging pollutant. Interactions between TA and protein preparations (extract; fraction and lectin) were also evaluated. TA was determined by solid phase extraction followed by high performance liquid chromatography - mass spectrometry. Moringa extract and flour removed TA from water. Extract removed TA in all concentrations and better removal (40%) was obtained with 40 mg L1; seed flour (particles < 5mm), 1.25 g L1 and 2.50 g L1 removed 28 and 29% of tetracycline, respectively; particles > 5 mm (0.50 g L1) removed 55% of antibiotic. Interactions between TA and seed preparations were assayed by haemagglutinating activity (HA). Specific HA (SHA) of extract (pH 7) was abolished with tetracycline (5 mg L1); fraction (75%) and lectin HA (97%) were inhibited with TA. Extract SHA decreased by 75% at pH 8. Zeta potential (ZP) of extract 700 mg L1 and tetracycline 50 mg L1 , pH range 5 to 8, showed different results. Extract ZP was more negative (10.73 mV to 16.00 mV) than tetracycline ZP (0.27 mV to 20.15 mV); ZP difference was greater in pH 8. The focus of this study was achieved since moringa preparations removed TA from water and compounds interacting with tetracycline involved at least lectin binding sites. This is a natural process, which do not promote environmental damage.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Furosemide (FD: Lasix) is a loop diuretic which strongly increases both urine flow and electrolyte urinary excretion. Healthy volunteers were administered 40 mg orally (dissolved in water) and concentrations of FD were determined in serum and urine for up to 6 h for eight subjects, who absorbed water at a rate of 400 ml/h. Quantification was performed by HPLC with fluorescence detection (excitation at 233 nm, emission at 389 nm) with a limit of detection of 5 ng/ml for a 300-microliters sample. The elution of FD was completed within 4 min using a gradient of acetonitrile concentration rising from 30 to 50% in 0.08 M phosphoric acid. The delay to the peak serum concentration ranged from 60 to 120 min. FD was still easily measurable in the sera from all subjects 6 h after administration. In urine, the excretion rates reached their maximum between 1 and 3 h. The total amount of FD excreted in the urine averaged 11.2 mg (range 7.6-14.0 mg), with a mean urine volume of 3024 ml (range 2620-3596 ml). Moreover, the urine density was lower than 1.010 (recommended as an upper limit in doping analysis to screen diuretics) only for 2 h. An additional volunteer was administered 40 mg of FD and his urine was collected over a longer period. FD was still detectable 48 h after intake. Gas chromatography-mass spectrometry with different types of ionization was used to confirm the occurrence of FD after permethylation of the extract. Negative-ion chemical ionization, with ammonia as reactant gas, was found to be the most sensitive method of detection.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Mississippi Valley-type zinc and lead deposits at Topla (250,150 metric tons (t) of ore grading 1.0 wt % Zn and 3.3 wt % Pb) and Mezica (19 million metric tons (Mt) of ore grading 5.3 wt % Pb and 2.7 wt % Zn) occur within the Middle to Upper Triassic platform carbonate rocks of the northern Karavanke/Drau Range geotectonic units of the Eastern Alps, Slovenia. The ore and host rocks of these deposits have been investigated by a combination of inorganic and organic geochemical methods to determine major, trace, and rare earth element (REE) concentrations, hydrocarbon distribution, and stable isotope ratios of carbonates, kerogen, extractable organic matter, and individual hydrocarbons. These data combined with sedimentological evidence provide insight into the paleoenvironmental conditions at the site of ore formation. The carbonate isotope composition, the REE patterns, and the distribution of hydrocarbon biomarkers (normal alkanes and steranes) suggest a marine depositional environment. At Topla, a relatively high concentration of redox sensitive trace elements (V, Mo, U) in the host dolostones and REE patterns parallel to that of the North American shale composite suggest that sediments were deposited in a reducing environment. Anoxic conditions enhanced the preservation of organic matter and resulted in relatively higher total organic carbon contents (up to 0.4 wt %). The isotopic composition of the kerogen (delta C-13(kerogon) = -29.4 to -25.0 parts per thousand, delta N-15(kerogen) = -.13.6 to 6.8 parts per thousand) suggests that marine algae and/or bacteria were the main source of organic carbon with a very minor contribution from detrital continental plants and a varying degree of alteration. Extractable organic matter from Topla ore is generally depleted in C-13 compared to the associated kerogen, which is consistent with an indigenous source of the bitumens. The mineralization correlates with delta N-15(kerogen) values around 0 per mil, C-13 depleted kerogen, C-13 enriched n-heptadecane, and relatively high concentrations of bacteria] hydrocarbon biomarkers, indicating a high cyanobacterial biomass at the site of ore formation. Abundant dissimilatory sulfate-reducing bacteria, feeding on the cyanobacterial remains, led to accumulation of biogenic H2S in the pore water of the sediments. This biogenic H2S was mainly incorporated into sedimentary organic matter and diagenetic pyrite. Higher bacterial activity at the ore site also is indicated by specific concentration ratios of hydrocarbons, which are roughly correlated with total Pb plus Zn contents. This correlation is consistent with mixing of hydrothermal metal-rich, fluids and local bacteriogenic sulfide sulfur. The new geochemical data provide supporting evidence that Topla is a low-temperature Mississippi Valley-type deposit formed in an anoxic supratidal saline to hypersaline environment. A laminated cyanobacterial mat, with abundant sulfate-reducing bacteria was the main site of sulfate reduction.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: Quantification of myocardial blood flow (MBF) with generator-produced (82)Rb is an attractive alternative for centres without an on-site cyclotron. Our aim was to validate (82)Rb-measured MBF in relation to that measured using (15)O-water, as a tracer 100% of which can be extracted from the circulation even at high flow rates, in healthy control subject and patients with mild coronary artery disease (CAD). METHODS: MBF was measured at rest and during adenosine-induced hyperaemia with (82)Rb and (15)O-water PET in 33 participants (22 control subjects, aged 30 ± 13 years; 11 CAD patients without transmural infarction, aged 60 ± 13 years). A one-tissue compartment (82)Rb model with ventricular spillover correction was used. The (82)Rb flow-dependent extraction rate was derived from (15)O-water measurements in a subset of 11 control subjects. Myocardial flow reserve (MFR) was defined as the hyperaemic/rest MBF. Pearson's correlation r, Bland-Altman 95% limits of agreement (LoA), and Lin's concordance correlation ρ (c) (measuring both precision and accuracy) were used. RESULTS: Over the entire MBF range (0.66-4.7 ml/min/g), concordance was excellent for MBF (r = 0.90, [(82)Rb-(15)O-water] mean difference ± SD = 0.04 ± 0.66 ml/min/g, LoA = -1.26 to 1.33 ml/min/g, ρ(c) = 0.88) and MFR (range 1.79-5.81, r = 0.83, mean difference = 0.14 ± 0.58, LoA = -0.99 to 1.28, ρ(c) = 0.82). Hyperaemic MBF was reduced in CAD patients compared with the subset of 11 control subjects (2.53 ± 0.74 vs. 3.62 ± 0.68 ml/min/g, p = 0.002, for (15)O-water; 2.53 ± 1.01 vs. 3.82 ± 1.21 ml/min/g, p = 0.013, for (82)Rb) and this was paralleled by a lower MFR (2.65 ± 0.62 vs. 3.79 ± 0.98, p = 0.004, for (15)O-water; 2.85 ± 0.91 vs. 3.88 ± 0.91, p = 0.012, for (82)Rb). Myocardial perfusion was homogeneous in 1,114 of 1,122 segments (99.3%) and there were no differences in MBF among the coronary artery territories (p > 0.31). CONCLUSION: Quantification of MBF with (82)Rb with a newly derived correction for the nonlinear extraction function was validated against MBF measured using (15)O-water in control subjects and patients with mild CAD, where it was found to be accurate at high flow rates. (82)Rb-derived MBF estimates seem robust for clinical research, advancing a step further towards its implementation in clinical routine.