1000 resultados para Healthcare Channel


Relevância:

20.00% 20.00%

Publicador:

Resumo:

While enhanced cybersecurity options, mainly based around cryptographic functions, are needed overall speed and performance of a healthcare network may take priority in many circumstances. As such the overall security and performance metrics of those cryptographic functions in their embedded context needs to be understood. Understanding those metrics has been the main aim of this research activity. This research reports on an implementation of one network security technology, Internet Protocol Security (IPSec), to assess security performance. This research simulates sensitive healthcare information being transferred over networks, and then measures data delivery times with selected security parameters for various communication scenarios on Linux-based and Windows-based systems. Based on our test results, this research has revealed a number of network security metrics that need to be considered when designing and managing network security for healthcare-specific or non-healthcare-specific systems from security, performance and manageability perspectives. This research proposes practical recommendations based on the test results for the effective selection of network security controls to achieve an appropriate balance between network security and performance

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concept of big data has already outperformed traditional data management efforts in almost all industries. Other instances it has succeeded in obtaining promising results that provide value from large-scale integration and analysis of heterogeneous data sources for example Genomic and proteomic information. Big data analytics have become increasingly important in describing the data sets and analytical techniques in software applications that are so large and complex due to its significant advantages including better business decisions, cost reduction and delivery of new product and services [1]. In a similar context, the health community has experienced not only more complex and large data content, but also information systems that contain a large number of data sources with interrelated and interconnected data attributes. That have resulted in challenging, and highly dynamic environments leading to creation of big data with its enumerate complexities, for instant sharing of information with the expected security requirements of stakeholders. When comparing big data analysis with other sectors, the health sector is still in its early stages. Key challenges include accommodating the volume, velocity and variety of healthcare data with the current deluge of exponential growth. Given the complexity of big data, it is understood that while data storage and accessibility are technically manageable, the implementation of Information Accountability measures to healthcare big data might be a practical solution in support of information security, privacy and traceability measures. Transparency is one important measure that can demonstrate integrity which is a vital factor in the healthcare service. Clarity about performance expectations is considered to be another Information Accountability measure which is necessary to avoid data ambiguity and controversy about interpretation and finally, liability [2]. According to current studies [3] Electronic Health Records (EHR) are key information resources for big data analysis and is also composed of varied co-created values [3]. Common healthcare information originates from and is used by different actors and groups that facilitate understanding of the relationship for other data sources. Consequently, healthcare services often serve as an integrated service bundle. Although a critical requirement in healthcare services and analytics, it is difficult to find a comprehensive set of guidelines to adopt EHR to fulfil the big data analysis requirements. Therefore as a remedy, this research work focus on a systematic approach containing comprehensive guidelines with the accurate data that must be provided to apply and evaluate big data analysis until the necessary decision making requirements are fulfilled to improve quality of healthcare services. Hence, we believe that this approach would subsequently improve quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Automatic speech recognition from multiple distant micro- phones poses significant challenges because of noise and reverberations. The quality of speech acquisition may vary between microphones because of movements of speakers and channel distortions. This paper proposes a channel selection approach for selecting reliable channels based on selection criterion operating in the short-term modulation spectrum domain. The proposed approach quantifies the relative strength of speech from each microphone and speech obtained from beamforming modulations. The new technique is compared experimentally in the real reverb conditions in terms of perceptual evaluation of speech quality (PESQ) measures and word error rate (WER). Overall improvement in recognition rate is observed using delay-sum and superdirective beamformers compared to the case when the channel is selected randomly using circular microphone arrays.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fire safety plays a vital role in building design because appropriate level of fire safety is important to safeguard lives and property. Cold-formed steel channel sections along with fire-resistive plasterboards are used to construct light-gauge steel frame (LSF) floor systems to provide adequate fire resistance ratings (FRR). It is common practice to use lipped channel sections (LCS) as joists in LSF floor systems, and past research has only considered such systems. This research focuses on adopting improved joist sections such as hollow flange channel (HFC) sections to improve the structural performance and FRR of cold-formed LSF floor systems under standard fire conditions. The structural and thermal performances of LSF floor systems made of a welded HFC, LiteSteel Beams (LSB), with different plasterboard and insulation configurations, were investigated using four full-scale fire tests under standard fires. These fire tests showed that the new LSF floor system with LSB joists improved the FRR in comparison to that of conventional LCS joists. Fire tests have provided valuable structural and thermal performance data of tested floor systems that included time-temperature profiles and failure times, temperatures, and modes. This paper presents the details of the fire tests conducted in this study and their results along with some important findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Australia has commenced public reporting and benchmarking of healthcare associated infections (HAIs), despite not having a standardised national HAI surveillance program. Annual hospital Staphylococcus aureus bloodstream (SAB) infection rates are released online, with other HAIs likely to be reported in the future. Although there are known differences between hospitals in Australian HAI surveillance programs, the effect of these differences on reported HAI rates is not known. Objective To measure the agreement in HAI identification, classification, and calculation of HAI rates, and investigate the influence of differences amongst those undertaking surveillance on these outcomes. Methods A cross-sectional online survey exploring HAI surveillance practices was administered to infection prevention nurses who undertake HAI surveillance. Seven clinical vignettes describing HAI scenarios were included to measure agreement in HAI identification, classification, and calculation of HAI rates. Data on characteristics of respondents was also collected. Three of the vignettes were related to surgical site infection and four to bloodstream infection. Agreement levels for each of the vignettes were calculated. Using the Australian SAB definition, and the National Health and Safety Network definitions for other HAIs, we looked for an association between the proportion of correct answers and the respondents’ characteristics. Results Ninety-two infection prevention nurses responded to the vignettes. One vignette demonstrated 100 % agreement from responders, whilst agreement for the other vignettes varied from 53 to 75 %. Working in a hospital with more than 400 beds, working in a team, and State or Territory was associated with a correct response for two of the vignettes. Those trained in surveillance were more commonly associated with a correct response, whilst those working part-time were less likely to respond correctly. Conclusion These findings reveal the need for further HAI surveillance support for those working part-time and in smaller facilities. It also confirms the need to improve uniformity of HAI surveillance across Australian hospitals, and raises questions on the validity of the current comparing of national HAI SAB rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the results of the time dispersion parameters obtained from a set of channel measurements conducted in various environments that are typical of multiuser Infostation application scenarios are presented. The measurement procedure takes into account the practical scenarios typical of the positions and movements of the users in the particular Infostation network. To provide one with the knowledge of how much data can be downloaded by users over a given time and mobile speed, data transfer analysis for multiband orthogonal frequency division multiplexing (MB-OFDM) is presented. As expected, the rough estimate of simultaneous data transfer in a multiuser Infostation scenario indicates dependency of the percentage of download on the data size, number and speed of the users, and the elapse time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

People get into healthcare because they want to help society. And when a new hospital is briefed, everyone tries to do their best, but the process is mired by the impossibility of the task. Stakeholders rarely understand the architectural process, nobody can predict the future, and the only thing for certain is that everything will change as the project unfolds, revealing errors in initial assumptions and calculations, shifts in needs, new technologies etc. Yet there’s always pressure to keep to the programme and to press on regardless. This chaos leads eventually to suboptimal results: hospitals the world over are riddled with inefficiencies, idiosyncrasies, incredible wastage and features that lead to poor clinical outcomes. This talk will sketch out the basics of Scrum, the most popular open-source Lean/Agile methodology. It will discuss what healthcare designers can learn from the geeks in Silicon Valley reduce risk, meet deadlines and deliver the highest possible value for the budget despite the uncertainty.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lean principles create highly efficient healthcare facilities by maximising the clinical value of every part of a facility and by removing everything else. In order that clinical accommodation can be used for a diverse set of functions including unexpected tasks and processes that haven’t even been invented, they have to be big. But somewhat surprisingly, whole facilities tend to shrink in terms of gross floor areas by disposing of non-clinical spaces when designed using Lean principles. And with the whole unit – the building costs shrink too. Using examples from the UK and the USA, this talk explores the unexpected solutions and improved outcomes when designers use a Lean approach to design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Public submission # 029 to a Australian federal parliamentary committee considering proposed legislative changes to the Commonwealth's Healthcare Identifiers Act 2010 and the Personally Controlled Electronic Health Records Act 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new physically based classical continuous potential distribution model, particularly considering the channel center, is proposed for a short-channel undoped body symmetrical double-gate transistor. It involves a novel technique for solving the 2-D nonlinear Poisson's equation in a rectangular coordinate system, which makes the model valid from weak to strong inversion regimes and from the channel center to the surface. We demonstrated, using the proposed model, that the channel potential versus gate voltage characteristics for the devices having equal channel lengths but different thicknesses pass through a single common point (termed ``crossover point''). Based on the potential model, a new compact model for the subthreshold swing is formulated. It is shown that for the devices having very high short-channel effects (SCE), the effective subthreshold slope factor is mainly dictated by the potential close to the channel center rather than the surface. SCEs and drain-induced barrier lowering are also assessed using the proposed model and validated against a professional numerical device simulator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fire performance of cold-formed steel members is an important criterion to be verified for their successful use in structural applications. However, lack of clear design guidance on their fire performance has inhibited their usage in buildings. Their elevated temperature mechanical properties, i.e., yield strengths, elastic moduli and stress–strain relationships, are imperative for the fire design. In the past many researchers have proposed elevated temperature mechanical property reduction factors for cold-formed steels, however, large variations exist among them. The LiteSteel Beam (LSB), a hollow flange channel section, is manufactured by a combined cold-forming and electric resistance welding process. Its web, inner and outer flange elements have different yield strengths due to varying levels of cold-working caused by their manufacturing process. Elevated temperature mechanical properties of LSBs are not the same even within their cross-sections. Therefore an experimental study was undertaken to determine the elevated temperature mechanical properties of steel plate elements in LSBs. Elevated temperature tensile tests were performed on web, inner and outer flange specimens taken from LSBs, and their results are presented in this paper including their comparisons with previous studies. Based on the test results and the proposed values from previous studies and fire design standards, suitable predictive equations are proposed for the determination of elevated temperature mechanical properties of LSB web and flange elements. Suitable stress–strain models are also proposed for the plate elements of this cold-formed and welded hollow flange channel section.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fire resistance of load bearing Light Gauge Steel Frame (LSF) wall systems is important to protect lives and properties in fire accidents. Recent fire tests of LSF walls made of the new cold-formed and welded hollow flange channel (HFC) section studs and the commonly used lipped channel section (LCS) studs have shown the influence of stud sections on the fire resistance rating (FRR) of LSF walls. To advance the use of HFC section studs and to verify the outcomes from the fire tests, finite element models were developed to predict the structural fire performance of LSF walls made of welded HFC section studs. The developed models incorporated the measured non-uniform temperature distributions in LSF wall studs due to the exposure of standard fire on one side, and accurate elevated temperature mechanical properties of steel used in the stud sections. These models simulated the various complexities involved such as thermal bowing and neutral axis shift caused by the non-uniform temperature distribution in the studs. The finite element analysis (FEA) results agreed well with the full scale fire test results including the FRR, outer hot and cold flange temperatures at failure and axial deformation and lateral displacement profiles. They also confirmed the superior fire performance of LSF walls made of HFC section studs. The applicability of both transient and steady state FEA of LSF walls under fire conditions was verified in this study, which also investigated the effects of using various temperature distribution patterns across the cross-section of HFC section studs on the FRR of LSF walls. This paper presents the details of this numerical study and the results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical and experimental study of the hydraulic jump in stilling basins with abrupt drop and sudden enlargement, called the spatial B-jump here, is carried out for finding the sequent depth ratio and resulting energy dissipation. The spatial B-jump studied has its toe downstream of the expansion section, and the stream lines at the toe are characterized by downward curvature. An expression is obtained for the sequent depth ratio based on the momentum equation with suitable assumptions for the extra pressure force term because of the abrupt drop in the bed and sudden enlargement in the basin width. Predictions compare favorably with experiments. It is shown that the spatial B-jump needs less tailwater depth, thereby enhancing the stability of the jump when compared either with spatial jump, which forms in sudden expanding channels, or with B-jump, which forms in a channel with an abrupt drop in bed. It is also shown that there is a significant increase in relative energy loss for the spatial B-jump compared to either the spatial jump or B-jump alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have designed a four-helix protein that is expected to tetramerize in the membrane to form an ion channel with a structurally well defined pore. A synthetic peptide corresponding to the channel lining helix facilitates ion transport across liposomal membranes and largely helical in membranes. Detailed circular dichroism studies of the peptide in methanol, water and methanal-water mixtures reveal that it is helical in methanol, beta-structured in 97.5% water and a combination of these two structures at intermediate compositions of methanol and water. A fluorescence resonance energy transfer study of the peptide shows that the peptide is monomeric in methanol but undergoes extensive anti-parallel aggregation in aqueous solution.