879 resultados para HEART-RATE


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the present study was to examine the relationship between the performance heart rate during an ultra-endurance triathlon and the heart rate corresponding to several demarcation points measured during laboratory-based progressive cycle ergometry and treadmill running. Less than one month before an ultra-endurance triathlon, 21 well-trained ultra-endurance triathletes (mean +/- s: age 35 +/- 6 years, height 1.77 +/- 0.05 in, mass 74.0 +/- 6.9 kg, (V) over dot O-2peak = 4.75 +/- 0.42 1 center dot min(-1)) performed progressive exercise tests of cycle ergometry and treadmill running for the determination of peak oxygen uptake ((V) over do O-2peak), heart rate corresponding to the first and second ventilatory thresholds, as well as the heart rate deflection point. Portable telemetry units recorded heart rate at 60 s increments throughout the ultra-endurance triathlon. Heart rate during the cycle and run phases of the ultra-endurance triathlon (148 +/- 9 and 143 +/- 13 beats center dot min(-1) respectively) were significantly (P < 0.05) less than the second ventilatory thresholds (160 +/- 13 and 165 +/- 14 beats center dot min(-1) respectively) and heart rate deflection points (170 +/- 13 and 179 +/- 9 beats center dot min(-1) respectively). However, mean heart rate during the cycle and run phases of the ultra-endurance triathlon were significantly related to (r = 0.76 and 0.66; P < 0.01), and not significantly different from, the first ventilatory thresholds (146 +/- 12 and 148 +/- 15 beats center dot min(-1) respectively). Furthermore, the difference between heart rate during the cycle phase of the ultra-endurance triathlon and heart rate at the first ventilatory threshold was related to marathon run time (r = 0.61; P < 0.01) and overall ultra-endurance triathlon time (r = 0.45; P < 0.05). The results suggest that triathletes perform the cycle and run phases of the ultra-endurance triathlon at an exercise intensity near their first ventilatory threshold

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This is the protocol for a review and there is no abstract. The objectives are as follows: To evaluate the effectiveness and risks of fetal scalp lactate sampling in the assessment of fetal wellbeing during labour, compared with no testing or alternative additional testing (pH, fetal pulse oximetry, etc) for women exhibiting a non-reassuring cardiotocograph trace. A secondary objective of the review is to determine whether effectiveness and risks of intrapartum fetal scalp lactate sampling is influenced by the following: stage of labour; gestation less than 37 completed weeks, greater than or equal to 37 completed weeks; additional tests performed to confirm the presence or absence of fetal acidemia during labour.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Changes in heart rate (f(H)) and cloacal ventilation frequency (f(C)) were investigated in the Fitzroy turtle, Rheodytes leukops, under normoxic (17.85 kPa) and hypoxic (3.79 kPa) conditions at 25 degrees C. Given R. leukops' high reliance on aquatic respiration via the cloacal bursae, the objective Of this Study was to examine the effect of varying aquatic PO2 levels upon the expression of a bradycardia in a freely diving, bimodally respiring turtle. In normoxia, mean diving f(H) and f(C) for R. leukops remained constant with increasing submergence length, indicating that a bradycardia failed to develop during extended dives of up to 3 days. Alternatively, exposure to aquatic hypoxia resulted in the expression of a bradycardia as recorded by a decreasing mean diving f(H) with increasing dive duration. The observed bradycardia is attributed to a hypoxic-induced metabolic depression, possibly facilitated by a concurrent decrease in f(C). Results suggest that R. leukops alters its strategy from aquatic O-2 extraction via cloacal respiration in normoxia to O-2 conservation when exposed to aquatic hypoxia for the purpose of extending dive duration. Upon surfacing, a significant tachycardia was observed for R. leukops regardless of aquatic PO2, presumably functioning to rapidly equilibrate blood and tissue gas tensions with alveolar gas to reduce surfacing duration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since its introduction, pulse oximetry has become a conventional clinical measure. Besides being arterial blood oxygen saturation (SpO2) measure, pulse oximeters can be used for other cardiovascular measurements, like heart rate (HR) estimations, derived from its photo plethysmographic (PPG) signals. The temporal coherence of the PPG signals and thereby HR estimates are heavily dependent on its minimal phase variability. A Masimo SET Rad-9TM, Novametrix Oxypleth and a custom designed PPG system were investigated for their relative phase variation. R-R intervals from electro-cardiogram (ECG) were recorded concurrently as reference. PPG signals obtained from the 3 systems were evaluated by comparing their respective beat-to-beat (B-B) intervals with the corresponding R-R estimates during a static test. For their relative B-B comparison to the ECG, Novametrix system differed 0.680.52% (p

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a new method for characterizing the newborn heart rate variability (HRV) is proposed. The central of the method is the newly proposed technique for instantaneous frequency (IF) estimation specifically designed for nonstationary multicomponen signals such as HRV. The new method attempts to characterize the newborn HRV using features extracted from the time–frequency (TF) domain of the signal. These features comprise the IF, the instantaneous bandwidth (IB) and instantaneous energy (IE) of the different TF components of the HRV. Applied to the HRV of both normal and seizure suffering newborns, this method clearly reveals the locations of the spectral peaks and their time-varying nature. The total energy of HRV components, ET and ratio of energy concentrated in the low-frequency (LF) to that in high frequency (HF) components have been shown to be significant features in identifying the HRV of newborn with seizures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we propose features extracted from the heart rate variability (HRV) based on the first and second conditional moments of time-frequency distribution (TFD) as an additional guide for seizure detection in newborn. The features of HRV in the low frequency band (LF: 0-0.07 Hz), mid frequency band (MF: 0.07-0.15 Hz), and high frequency band (HF: 0.15-0.6 Hz) have been obtained by means of the time-frequency analysis using the modified-B distribution (MBD). Results of ongoing time-frequency research are presented. Based on our preliminary results, the first conditional moment of HRV which is also known as the mean/central frequency in the LF band and the second conditional moment of HRV which is also known as the variance/instantaneous bandwidth (IB) in the HF band can be used as a good feature to discriminate the newborn seizure from the non-seizure