958 resultados para Goodenough’s human figure test
Resumo:
We investigated roles of different forms of cytochrome P450 (P450 or CYP) in the metabolic activation of heterocyclic amines (HCAs) and other procarcinogens to genotoxic metabolite(s) in the newly developed umu tester strains Salmonella typhimurium (S. typhimurium) OY1002/1A1, OY1002/1A2, OY1002/1B1, OY1002/2C9, OY1002/2D6, OY1002/2E1 and OY 1002/3A4. which express respective human P450 enzymes and NADPH-cytochrome P350 reductase (reductase) and bacterial O-acetyltransferase (O-AT). These strains were established by introducing two plasmids into S. typhimurium TA 1535, one carrying both P450 and the reductase cDNA in a bicistronic construct under control of an IPTG-inducible double me promoter and the other, pOA 102, carrying O-AT and umuClacZ fusion genes. Expression levels of CYP were found to range between 35 to 550 nmol/l cell culture in the strains tested. O-AT activities in different strains ranged from 52 to 135 nmol isoniazid acetylated/min/mg protein. All HCAs tested, and 2-aminoanthracene and 2-aminofluorene exhibited high genotoxicity in the OY1002/1A2 strain, and genotoxicity of 2-amino-3-methylimidazo [4,5-f]quinoline was detected in both the OY1002/1A1 and OY1002/1A2 strains. 1-Amino-1,4-dimethyl-5H-pyrido[4.3-b]-indole and 3-amino-1-methyl-5H-pyrido[4,3-b]-indole were activated in the OY1002/1A1, OY1002/1B1, OY1002/1A2, and OY1002/3A4 strains. Aflatoxin B-1 exhibited genotoxicity in the OY1002/1A2, OY1002/1A1, and OY1002/3A4 strains. beta -Naphthylamine and benzo[a]pyrene did not exhibit genotoxicity in any of the strains. These results suggest that CYP1A2 is the major cytochrom P450 enzyme involved in bioactivation of HCAs. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
As the use of technological devices in everyday environments becomes more prevalent, it is clear that access to these devices has become an important aspect of occupational performance. Children are increasingly required to competently manipulate technology such as the computer to fulfil occupational roles of student and player. Occupational therapists are in a position to facilitate the successful interface between children and standard computer technologies. The literature has supported the use of direct manipulation interfaces in computing that requires mastery of devices such as the mouse. Identification of children likely to experience difficulties with mouse use will inform the development of appropriate methods of intervention promoting mouse skill and further enhance participation in occupational tasks. The aim of this paper is to discuss the development of an assessment of mouse proficiency for children. It describes the construction of the assessment, the content of the test, and its content validity.
Resumo:
We investigated the use of mice transgenic for human leucocyte antigen (HLA) A*0201 antigen-binding domains to test vaccines composed of defined HLA A*0201-restricted cytotoxic T-lymphocyte (CTL) epitopes of human papillomavirus (HPV) type 16 E7 oncoprotein. HPV is detected in >90% of cervical carcinomas. HPV16 E7 oncoprotein transforms cells of the uterine cervix and functions as a tumour-associated antigen to which immunotherapeutic strategies may be directed. We report that although the HLA A*0201 E7 epitope peptides function both to prime for E7 CTL responses, and to sensitize target cells for E7-directed CTL killing in situations where antigen processing is not required, the epitopes are not processed out of either endogenously expressed or immunization-introduced E7, by the mouse antigen-processing and presentation machinery. Thus (1) CTL induced by HLA A*0201 peptide immunization killed E7 peptide-pulsed target cells, but did not kill target cells expressing whole E7; (2) immunization with whole E7 protein did not elicit CTL directed to HLA A*0201-restricted E7 CTL epitopes; (3) HLA A*0201-restricted CTL epitopes expressed in the context of a DNA polytope vaccine did not activate E7-specific T cells either in 'conventional' HLA A*0201 transgenic (A2.1K(b) ) mice, or in HHD transgenic mice in which expression of endogenous H-2 class 1 is precluded; and (4) HLA A*0201 E7 peptide epitope immunization was incapable of preventing the growth of an HLA A*0201- and E7-expressing tumour. There are generic implications for the universal applicability of HLA-class 1 transgenic mice for studies of human CTL epitope presentation in murine models of human infectious disease where recognition of endogenously processed antigen is necessary. There are also specific implications for the use of HLA A2 transgenic mice for the development of E7-based therapeutic vaccines for cervical cancer.
Resumo:
Placental growth hormone (PGH) progressively replaces pituitary growth hormone in the maternal circulation from mid-gestation onwards in human pregnancy. Our previous investigations have shown that placental growth hormone concentrations correlate well with foetal growth. Despite the apparent correlation between PGH and birthweight, the physiology of its secretion during pregnancy has not been well defined. We investigated the response of maternal serum PCH to oral glucose loading in pregnant women (n = 24) who demonstrated normal glucose tolerance at a mean gestation of 29 weeks. Mean (SEM) fasting PGH concentrations were high (36.9 [6.4] ng/ml). No suppression of PGH was noted at one, two or three hours after a 75 g oral glucose load. Similarly, no changes were noted in growth hormone binding protein or in calculated free PGH over the course of the glucose tolerance test. As expected, insulin concentrations rose sixfold and insulin like growth factor binding protein 1 concentrations fell by 20% with glucose loading. Cot-relation analysis showed maternal weight, BMI, fasting serum glucose serum insulin to be significantly correlated with the babies' birthweight. Our results support the proposition that PGH concentrations in maternal serum are not Suppressed by oral glucose loading in non-diabetic mothers.
Resumo:
The recent description of the respiratory pathogen human metapneumovirus (hMPV) has highlighted a deficiency in current diagnostic techniques for viral agents associated with acute lower respiratory tract infections. We describe two novel approaches to the detection of viral RNA by use of reverse transcriptase PCR (RT-PCR). The PCR products were identified after capture onto a solid-phase medium by hybridization with a sequence-specific, biotinylated oligonucleotide probe. The assay was applied to the screening of 329 nasopharyngeal aspirates sampled from patients suffering from respiratory tract disease. These samples were negative for other common microbial causes of respiratory tract disease. We were able to detect hMPV sequences in 32 (9.7%) samples collected from Australian patients during 2001. To further reduce result turnaround times we designed a fluorogenic TaqMan oligoprobe and combined it with the existing primers for use on the LightCycler platform. The real-time RT-PCR proved to be highly reproducible and detected hMPV in an additional 6 out of 62 samples (9.6%) tested during the comparison of the two diagnostic approaches. We found the real-time RT-PCR to be the test of choice for future investigation of samples for hMPV due to its speed, reproducibility, specificity, and sensitivity.
Resumo:
The Test of Mouse Proficiency (TOMP) was developed to assist occupational therapists and education professionals assess computer mouse competency skills in children from preschool to upper primary (elementary) school age. The preliminary reliability and validity of TOMP are reported in this paper. Methods used to examine the internal consistency, test-retest reliability, and criterion- and construct-related validity of the test are elaborated. In the continuing process of test refinement, these preliminary studies support to varying degrees the reliability and validity of TOMP. Recommendations for further validation of the assessment are discussed along with indications for potential clinical application.
Resumo:
In medical emergency situations, when a patient needs a blood transfusion, the universal blood type O− is administered. This procedure may lead to the depletion of stock reserves of O− blood. Nowadays, there is no commercial equipment capable of determining the patient's blood type in situ, in a fast and reliable process. Human blood typing is usually performed through the manual test, which involves a macroscopic observation and interpretation of the results by an analyst. This test, despite of having a fast response time, may lead to human errors, which sometimes can be fatal to the patient. This paper presents the development of an automatic mechatronic prototype for determining human blood typing (ABO and Rh systems) through image processing techniques. The prototype design takes into account the characteristics of reliability of analysis, portability, and response time allowing the system to be used in emergency situations. The developed prototype performs blood and reagents mixture acquires the resultant image and processes the data (based on image processing techniques) to determine the sample blood type. It was tested in a laboratory, using cataloged samples of blood types, provided by the Portuguese Institute of Blood and Transplantation. Hereafter, it is expected to test and validate the prototype in clinical environments.
Resumo:
Cryptosporidium sp., a coccidian parasite usually found in the faeces of cattle, has been recently implicated as an agent of human intestinal disease, mainly in immunocompromised patients. In the study realized, by an indirect immunofluorescence technique, specific immunoglobulins (IgG and IgM) have been demonstrated in human serum against Cryptosporidium oocysts. Purified oocysts were used as antigens in the indirect immunofluorecence assay. After analyzing this test in sera from selected groups of patients, the frequency of both specific IgG and IgM of immunocompetent children who were excreting oocysts in their faeces was 62% and in children with negative excretion of oocysts was 20% and 40%, respectively. In adults infected with the human immunodeficiency virus (HIV) and who were excreting Cryptosporidium in their stools, the frequency was 57% for IgG but only 2% for IgM. Twenty three percent of immunocompromised adults with not determined excretion of oocysts in their stools had anti-Cryptosporidium IgG in their sera. Children infected with human immunodeficiency virus had no IgM and only 14% had IgG detectable in their sera. The indirect immunoflorescence assay, when used with other parasitological techniques appears to be useful for retrospective population studies and for diagnosis of acute infection. The humoral immune response of HIV positive patients to this protozoan agent needs clarification.
Resumo:
Lectins were labeled with fluorescein and tried as conjugates in the immunofluorescence (IP) test for the detection of IgM antibodies to T. gondii, in the diagnosis of acute toxoplasmosis. This approach was an attempt to find alternative reagents for anti-human IgM fluorescent conjugates (AHIgMFC), which contain quite frequently anaibcdies to toxoplasma, as contaminants, due to natural T. gondii infections among animals used for imunization. Lentil (Lens culinaris) lectin fluorescence conjugates (LcFC) provided most satisfactory results. The evaluation of LcFC carried out in a total of 179 sera from patients with acute and chronic toxoplasmosis, with non-related infections or healthy subjects, gave high values of relative efficiency, co-positivity and co-negativity indices, respectively 0.989, 0.969 and 1.000, in reference to the conventional AHIgMFC. Moreover, three batches of LcFC successively prepared gave reproducible test results. The advantage of LcFC as an alternative reagent for the serodiagnosis of acute toxoplasmosis is supported by practical aspects of its preparation.
Resumo:
The present study was carried out in two different areas of Province of Cordoba, Argentina, where there was a suspicious of endemic mycosis. The previous data were the presence of a clinical case of pulmonary cryptococcosis in one area (Alta Gracia) and the previous findings of a high incidence of coccidioidin and cryptococcin reactors in the population of the second one (Villa Dolores). In both areas soil samples for fungi were studied and Cryptococcus neoformans was found in 2/25 samples from Alta Gracia. In Villa Dolores Coccidioides immitis was isolated in 2/40 samples, and C. neoformans in 1/40 samples. Delayed hypersensitivity test with cryptococcin was determined in the population from Alta Gracia and it was found to be 5.3%. Positive cutaneous tests with coccidioidin (33.8%) and cryptococcin (31.9%) in Villa Dolores were obtained. With these findings two endemic areas of systemic mycoses in Cordoba, Argentina were delimited.
Resumo:
The present study evaluates the humoral and cellular immune responses in 35 volunteers submited to short antirabies vaccination schedules with the Fuenzalida & Palacios vaccine based on the administration of doses on non consecutive days. The volunteers were divided into two groups. The first group received a total number of five doses given on days 0, 4, 7, 20 and 35. The other group received four doses, the first one being a double dose given on day 0 and than three other single doses on days 7, 20 and 35. The evaluation of humoral immune response was carried out by serum neutralization (SN) and indirect immunofluorescense (IIF) tests, while the cellular immune response was evaluated by lymphoblastic transformation assay (LTA) and skin test (ST). According to our results these reduced schedules elicited early and effective humoral and cellulafimmune responses to rabies antigen suggesting that new reduced schedules should be extensively studied in order to give the proper bases to the proposition of changes in the current long-term schedule.
Resumo:
The absolute numbers of total leukocytes, lymphocytes, T cells, helper/inducer, suppressor/cytotoxic and B cells were decreased in the peripheral blood of patients with chronic Chagas' disease. Since antilymphocyte antibodies were present only in a minority of patients they probably cannot account for the abnormalities in lymphocyte subsets. Patient neutrophils stimulated with endotoxin-treated autologous plasma showed depressed chemotactic activity and this seems to be an intrinsic cellular defect rather than plasma inhibition. Random migration of neutrophils was normal. Reduction of nitroblue tetrazolium by endotoxin- stimulated neutrophils was also decreased. These findings further document the presence of immunosuppression in human Chagas' disease. They may be relevant to autoimmunity, defense against microorganisms and against tumor cells at least in a subset of patients with more severe abnormalities.
Resumo:
A dot enzyme-linked immunosorbent assay (DOT-ELISA) was developed to detect specific antibodies in cerebrospinal fluid (CSF) for human neurocysticercosis immunodiagnosis, with Cysticercus cellulosae antigen dotted on a new solid-phase. This was represented by sheets of a synthetic polyester fabric impregnated with a polymerized resin (N-methylol-acrylamide). A very stable preparation was thus obtained, the antigen being covalently bound by cross-linking with free N-methylol groups on the resin. Since robust, no special care was necessary for handling the solid-phase. The test could be performed at room-temperature. From 30 CSF samples assayed, 14 were positive, from a group of 15 cases of neurocysticercosis, with titers from 1 to 128; 15 other samples, from normals or other neurological diseases, were all negative. Test characteristics seem to indicate it as adequate for epidemiological surveys. A more detailed study on sensitivity, specificity, reproducibility and the use in serum samples is being conducted.
Resumo:
Serum sample obtained from a male, 12 year old patient suffering from Guillain-Barré syndrome (GBS) was positive for human T-lymphotropic virus (HTLV-I) antibody by the enzyme-linked immunosorbent assay (ELISA) and the Western Blot analysis (WB). Attempts to isolate enteroviruses (including poliovirus) from faecal material in both tissue culture and suckling mice were unsuccessful; in addition, acute and convalescent paired serum samples did not show any evidence of recent poliovirus infection when tested against the three serotypes. Specific tests for detection of Epstein-Barr virus infection were not performed; however, the Paul-Bunnel test yielded negative results. ELISA for detection of anti-cytomegalovirus IgM was also negative. The concomitant occurrence of either adult T cell leukemia (ATL) or lymphoma was not recorded in this case.
Resumo:
It was reevaluated a reduced schedule for anti-rabies post-exposure immunization with newborn mice nervous tissue vaccine (Fuenzalida 8c Palacios) in a group of 30 non exposed volunteers. The vaccine was administered by intramuscular injections on days zero, 2, 4, 16 and 27, in the deltoid area. Antibody levels were determinated by a simplified serum neutralization microtest on days zero, 16 and 37. On days 16 and 37 the antibody levels of the whole group was >0.5 IU/ml and >1.0 IU/ml, respectively. The cell mediated immunity was precociously detected (on day 4) by the delayed type hipersensitivity skin test. Our results show that this reduced schedule elicited an early and effective humoral and cellular immune response. However it is necessary other studies with larger groups of vaccinees in order to obtain definitive conclusion.