926 resultados para Forensic science
Resumo:
As the auditory ossicles are difficult to display without harming them in conventional autopsies, lesions of these minute bones and the ossicular chain are regularly missed. In this study, the method of choice in clinical medicine for the examination of such lesions, namely multislice computed tomography, was applied to 100 corpses. The hereby obtained results regarding ossicle luxation and petrous bone fracture indicated that the lesions were not dependant on the amount, but rather on the type of energy inflicted to the head.
Resumo:
Fatal falls from great height are a frequently encountered setting in forensic pathology. They present--by virtue of a calculable energy transmission to the body--an ideal model for the assessment of the effects of blunt trauma to a human body. As multislice computed tomography (MSCT) has proven not only to be invaluable in clinical examinations, but also to be a viable tool in post-mortem imaging, especially in the field of osseous injuries, we performed a MSCT scan on 20 victims of falls from great height. We hereby detected fractures and their distributions were compared with the impact energy. Our study suggests a marked increase of extensive damage to different body regions at about 20 kJ and more. The thorax was most often affected, regardless of the amount of impacting energy and the primary impact site. Cranial fracture frequency displayed a biphasic distribution with regard to the impacting energy; they were more frequent in energies of less than 10, and more than 20 kJ, but rarer in the intermediate energy group, namely that of 10-20 kJ.
Resumo:
At a party of a sports club, an argument started between two groups of young men, in the course of which one of the persons involved threw a beer glass hitting a young man of the other group, who collapsed with a profusely bleeding wound. Although resuscitation measures were initiated immediately, the victim died at the scene due to exsanguination from the completely severed left external carotid artery in combination with the aspiration of blood. Tests with drinking glasses thrown at a skull-neck model suggested that an undamaged beer glass thrown at the head of the victim could not cause the fatal injuries on the neck because of its splintering behaviour. In fact, it seemed that the beer glass had been damaged prior to throwing it and that its sharp edges perforated the skin on hitting the neck.
Resumo:
Morphological findings in death due to hypothermia are variable and predominantly unspecific. Goal of this study was to check the usefulness of post-mortem cross-sectional imaging methods in the diagnosis of externally invisible findings in death due to hypothermia. Three consecutive forensic cases that died due to hypothermia were examined using post-mortem multi-slice computed tomography (MSCT) and magnetic resonance imaging (MRI) prior to autopsy. MSCT excluded traumatic skeletal and fatty tissue injury. Using MRI, it was possible to detect hemorrhages within the muscles of the back in all three cases, a so far unknown finding in death due to hypothermia. MRI also allowed the detection of hemorrhages in the iliopsoas muscles. Wishnewsky spots remained radiologically undetected using the present examination techniques. In conclusion, hemorrhages of the muscles of the back might serve as a new sign of death due to hypothermia; however, additional studies on their specificity are necessary. Post-mortem MRI is considered as a good diagnosing tool for muscular hemorrhages, with a great potential for examination and documentation.
Resumo:
Homicide-suicides, the murder of one or several individuals followed by the suicide of the perpetrator, are rare but have devastating effects on families and communities. We did a systematic review and meta-analysis of studies comparing perpetrators of homicide-suicides with perpetrators of simple homicides and suicides and examined the proportion of firearm use and its correlation with firearm availability. We searched Medline and Embase from inception to July 2012 and identified 27 eligible studies. Perpetrators of homicide-suicides were older and more likely to be male and married to or separated from their victims than perpetrator of simple homicides or suicides. Influence of alcohol and a history of domestic violence or unemployment were less prevalent in homicide-suicides than in homicides. The proportion of firearm use in homicide-suicides varied across countries and was highest in the USA, Switzerland and South Africa, followed by Australia, Canada, The Netherlands and England and Wales, with a strong correlation between the use of firearms and the level of civilian gun ownership in the country. Our results indicate that homicide-suicides represent a distinct entity, with characteristics distinguishing them both from homicides and suicides.
Resumo:
The analysis and reconstruction of forensically relevant events, such as traffic accidents, criminal assaults and homicides are based on external and internal morphological findings of the injured or deceased person. For this approach high-tech methods are gaining increasing importance in forensic investigations. The non-contact optical 3D digitising system GOM ATOS is applied as a suitable tool for whole body surface and wound documentation and analysis in order to identify injury-causing instruments and to reconstruct the course of event. In addition to the surface documentation, cross-sectional imaging methods deliver medical internal findings of the body. These 3D data are fused into a whole body model of the deceased. Additional to the findings of the bodies, the injury inflicting instruments and incident scene is documented in 3D. The 3D data of the incident scene, generated by 3D laser scanning and photogrammetry, is also included into the reconstruction. Two cases illustrate the methods. In the fist case a man was shot in his bedroom and the main question was, if the offender shot the man intentionally or accidentally, as he declared. In the second case a woman was hit by a car, driving backwards into a garage. It was unclear if the driver drove backwards once or twice, which would indicate that he willingly injured and killed the woman. With this work, we demonstrate how 3D documentation, data merging and animation enable to answer reconstructive questions regarding the dynamic development of patterned injuries, and how this leads to a real data based reconstruction of the course of event.
Resumo:
To evaluate the sensitivity of postmortem computed tomography (PMCT) in rib fracture detection validated against autopsy. Fifty-one forensic cases underwent a postmortem CT prior to forensic autopsy. Two image readers (radiologist and forensic pathologist) assessed high resolution CT data sets for rib fractures. Correct recognition rates (CRR), sensitivity and specificity values were calculated over all observations as well as individually for every rib and region. Additionally, for partial rib fractures the sensitivity of autopsy was calculated vice versa. 3876 entries in each study protocol (autopsy, PMCT radiologist and PMCT forensic pathologist) were investigated. A total of 690 fractures (autopsy), 491 (PMCT and radiologist) and 559 (PMCT and forensic pathologist) were detected. The CRR was 0.85. Sensitivity and specificity of PMCT for rib fracture detection were 0.63 (0.58 radiologist, 0.68 forensic pathologist) and 0.97 (both readers 0.97), respectively. Low CRR and sensitivity values were obtained for antero-lateral fractures. Partial rib fractures were better detected by PMCT. PMCT has a rather low sensitivity for rib fracture detection when validated against autopsy and indicates that clinical CT may also demonstrate a reasonable number of false negatives. Partial rib fractures often remain undetected at autopsy.
Resumo:
We present postmortem computed tomography (pmCT) as well as postmortem magnetic resonance (pmMR) imaging findings in a case of type II DeBakey aortic dissection with a complete rupture of the ascending aorta compared to the findings obtained at forensic autopsy. PmCT only allowed a presumptive diagnosis of aortic dissection based on an anterior mediastinal enlargement. However, at pmMR the dissection including the aortic rupture was clearly visible. Visualization was realized in an unenhanced manner without the need for postmortem angiography.
Resumo:
The aim of this study was to investigate if acute myocardial infarction can be detected by post-mortem cardiac magnetic resonance (PMMR) at an earlier stage than by traditional autopsy, i.e., within less than 4 h after onset of ischemia; and if so, to determine the characteristics of PMMR findings in early acute infarcts. Twenty-one ex vivo porcine hearts with acute myocardial infarction underwent T2-weighted cardiac PMMR imaging within 3 h of onset of iatrogenic ischemia. PMMR imaging findings were compared to macroscopic findings. Myocardial edema induced by ischemia and reperfusion was visible on PMMR in all cases. Typical findings of early acute ischemic injury on PMMR consist of a central zone of intermediate signal intensity bordered by a rim of increased signal intensity. Myocardial edema can be detected on cardiac PMMR within the first 3 h after the onset of ischemia in porcine hearts. The size of myocardial edema reflects the area of ischemic injury in early acute (per-acute) myocardial infarction. This study provides evidence that cardiac PMMR is able to detect acute myocardial infarcts at an earlier stage than traditional autopsy and routine histology.
Resumo:
The aim of this study was to assess the potential of monoenergetic computed tomography (CT) images to reduce beam hardening artifacts in comparison to standard CT images of dental restoration on dental post-mortem CT (PMCT). Thirty human decedents (15 male, 58 ± 22 years) with dental restorations were examined using standard single-energy CT (SECT) and dual-energy CT (DECT). DECT data were used to generate monoenergetic CT images, reflecting the X-ray attenuation at energy levels of 64, 69, 88 keV, and at an individually adjusted optimal energy level called OPTkeV. Artifact reduction and image quality of SECT and monoenergetic CT were assessed objectively and subjectively by two blinded readers. Subjectively, beam artifacts decreased visibly in 28/30 cases after monoenergetic CT reconstruction. Inter- and intra-reader agreement was good (k = 0.72, and k = 0.73 respectively). Beam hardening artifacts decreased significantly with increasing monoenergies (repeated-measures ANOVA p < 0.001). Artifact reduction was greatest on monoenergetic CT images at OPTkeV. Mean OPTkeV was 108 ± 17 keV. OPTkeV yielded the lowest difference between CT numbers of streak artifacts and reference tissues (-163 HU). Monoenergetic CT reconstructions significantly reduce beam hardening artifacts from dental restorations and improve image quality of post-mortem dental CT.
Resumo:
BACKGROUND Instillation of contrast medium into stab wounds has shown promising results regarding visibility and assessment of general stab direction with computed tomography. However, the accuracy of this method--and, incidentally also probing of stab wounds--has to our knowledge not previously been examined. Also the effect of bluntness of different stabbing objects on the examination of stab wounds was not considered before this study. METHODS Using a pocket-knife, a steak-knife, and a Phillips screwdriver, nine stab wounds each were inflicted to three pork haunches. The depths of the stab wounds were determined by probing and multislice computed tomography (MSCT) after instillation of a contrast medium (CM) and then compared to those observed by dissection, our internal "gold standard". RESULTS In stab wounds inflicted by knives, MSCT-CM and probing provided results which differed by roughly 10-11% from the dissection results. In screwdriver stabs MSCT-CM showed a deviation of almost 30%, probing over 33%. DISCUSSION MSCT-CM is a possible alternative to layer-by-layer dissection in autopsy cases of knife stab wounds. Probing, although obsolete in post-mortem examinations, is sufficiently accurate in determining the length of a stab wound of a living person. In cases of stab wounds with blunt objects such as screwdrivers, neither MSCT-CM nor probing proved to be sufficiently accurate. CONCLUSION MSCT-CM is a possible alternative to layer-by-layer dissection in autopsy cases of knife stab wounds. Probing, although obsolete in post-mortem examinations, is sufficiently accurate in determining the length of a stab wound of a living person. In cases of stab wounds with blunt objects such as screwdrivers, neither MSCT-CM nor probing proved to be sufficiently accurate.
Resumo:
The aim of this study was to evaluate the reliability of the cardiothoracic ratio (CTR) in postmortem computed tomography (PMCT) and to assess a CTR threshold for the diagnosis of cardiomegaly based on the weight of the heart at autopsy. PMCT data of 170 deceased human adults were retrospectively evaluated by two blinded radiologists. The CTR was measured on axial computed tomography images and the actual cardiac weight was weighed at autopsy. Inter-rater reliability, sensitivity, and specificity were calculated. Receiver operating characteristic curves were calculated to assess enlarged heart weight by CTR. The autopsy definition of cardiomegaly was based on normal values of the Zeek method (within a range of both, one or two SD) and the Smith method (within the given range). Intra-class correlation coefficients demonstrated excellent agreements (0.983) regarding CTR measurements. In 105/170 (62 %) cases the CTR in PMCT was >0.5, indicating enlarged heart weight, according to clinical references. The mean heart weight measured in autopsy was 405 ± 105 g. As a result, 114/170 (67 %) cases were interpreted as having enlarged heart weights according to the normal values of Zeek within one SD, while 97/170 (57 %) were within two SD. 100/170 (59 %) were assessed as enlarged according to Smith's normal values. The sensitivity/specificity of the 0.5 cut-off of the CTR for the diagnosis of enlarged heart weight was 78/71 % (Zeek one SD), 74/55 % (Zeek two SD), and 76/59 % (Smith), respectively. The discriminative power between normal heart weight and cardiomegaly was 79, 73, and 74 % for the Zeek (1SD/2SD) and Smith methods respectively. Changing the CTR threshold to 0.57 resulted in a minimum specificity of 95 % for all three definitions of cardiomegaly. With a CTR threshold of 0.57, cardiomegaly can be identified with a very high specificity. This may be useful if PMCT is used by forensic pathologists as a screening tool for medico-legal autopsies.
Resumo:
An HPLC-DAD method for the quantitative analysis of Δ(9)-tetrahydrocannabinol (THC), Δ(9)-tetrahydrocannabinolic acid-A (THCA-A), cannabidiol (CBD), and cannabinol (CBN) in confiscated cannabis products has been developed, fully validated and applied to analyse seized cannabis products. For determination of the THC content of plant material, this method combines quantitation of THCA-A, which is the inactive precursor of THC, and free THC. Plant material was dried, homogenized and extracted with methanol by ultrasonication. Chromatographic separation was achieved with a Waters Alliance 2695 HPLC equipped with a Merck LiChrospher 60 RP-Select B (5μm) precolumn and a Merck LiChroCart 125-4 LiChrospher 60 RP-Select B (5μm) analytical column. Analytes were detected and quantified using a Waters 2996 photo diode array detector. This method has been accepted by the public authorities of Switzerland (Bundesamt für Gesundheit, Federal Office of Public Health), and has been used to analyse 9092 samples since 2000. Since no thermal decarboxylation of THCA-A occurs, the method is highly reproducible for different cannabis materials. Two calibration ranges are used, a lower one for THC, CBN and CBD, and a higher one for THCA-A, due to its dominant presence in fresh plant material. As provider of the Swiss proficiency test, the robustness of this method has been tested over several years, and homogeneity tests even in the low calibration range (1%) show high precision (RSD≤4.3%, except CBD) and accuracy (bias≤4.1%, except CBN).
Resumo:
Delta-9-tetrahydrocannabinolic acid A (THCA-A) is the biosynthetic precursor of delta-9-tetrahydrocannabinol (THC) in cannabis plants, and has no psychotropic effects. THCA-A can be detected in blood and urine, and several metabolites have been identified. THCA-A was also shown to be incorporated in hair by side stream smoke to a minor extent, but incorporation via blood stream or sweat seems unlikely. The detection of THCA-A in biological fluids may serve as a marker for differentiating between the intake of prescribed THC medication – containing only pure THC – and cannabis products containing THC besides THC-acid A and other cannabinoids. However, the knowledge about its usefulness in forensic cases is very limited. The aim of the present work was the development of a reliable method for THCA-A determination in human blood or plasma using LC–MS/MS and application to cases of driving under the influence of drugs. Fifty eight (58) authentic whole blood and the respective plasma samples were collected from drivers suspected of driving under the influence of cannabis from the region of Bern (Switzerland). Samples were first tested for THC, 11-OH-THC and THC-COOH, and then additionally for THCA-A. For this purpose, the existing LC–MS/MS method was modified and validated, and found to be selective and linear over a range of 1.0 to 200 ng/mL (the correlation coefficients were above 0.9980 in all validation runs). Limit of detection (LOD) and limit of quantification (LOQ) were 0.3 ng/mL and 1.0 ng/mL respectively. Intra- and inter-assay accuracy were equal or better than 90% and intra- and inter-assay precision were equal or better than 11.1%. The mean extraction efficiencies were satisfactory being equal or higher than 85.4%. THCA-A was stable in whole blood samples after 3 freeze/thaw cycles and storage at 4 °C for 7 days. Re-injection (autosampler) stability was also satisfactory. THC was present in all blood samples with levels ranging from 0.7 to 51 ng/mL. THCA-A concentrations ranged from 1.0 to 496 ng/mL in blood samples and from 1.4 to 824 ng/mL in plasma samples. The plasma:blood partition coefficient had a mean value of 1.7 (±0.21, SD). No correlation was found between the degree of intoxication or impairment stated in the police protocols or reports of medical examinations and the detected THCA-A-concentration in blood.