897 resultados para Filtration glomérulaire
Resumo:
The present work investigates the fouling mechanisms of PVDF hollow fibre membrane (0.03 μm) during the dead end ultrafiltration at a fixed permeate flux (outside to inside configuration) of complex synthetic seawater composed by humic acids, alginic acids, inorganic particles and numerous salts at high concentrations. Short term ultrafiltration experiments at 100 L.h-1.m-2 show that the optimal specific filtered volume seems to be equal to 50 L.m-2. A residual fouling resistance equal to 2.1010 m-1 is added after each cycle of filtration during 8h of ultrafiltration at 100 L.h-1.m-2 and 50 L.m-2. Most of the fouling is reversible (80%). Organics are barely (15% of humic acids) retained by the membrane. Backwash efficiency drops during operation which induces less organics into backwash waters. Humic acids could preferentially accumulate on the membrane early in the ultrafiltration and alginic acids after the build-up of a fouling pre-layer. Colloids and particulates could accumulate inside a heterogeneous fouling layer and/or the concentrate compartment of the membrane module before being more largely recovered inside backwash waters.
Estimating glomerular filtration rate in kidney transplantation: Still searching for the best marker
Resumo:
Kidney transplantation is the treatment of choice for end-stage renal disease. The evaluation of graft function is mandatory in the management of renal transplant recipients. Glomerular filtration rate (GFR), is generally considered the best index of graft function and also a predictor of graft and patient survival. However GFR measurement using inulin clearance, the gold standard for its measurement and exogenous markers such as radiolabeled isotopes ((51)Cr EDTA, (99m)Tc DTPA or (125)I Iothalamate) and non-radioactive contrast agents (Iothalamate or Iohexol), is laborious as well as expensive, being rarely used in clinical practice. Therefore, endogenous markers, such as serum creatinine or cystatin C, are used to estimate kidney function, and equations using these markers adjusted to other variables, mainly demographic, are an attempt to improve accuracy in estimation of GFR (eGFR). Nevertheless, there is some concern about the inability of the available eGFR equations to accurately identify changes in GFR, in kidney transplant recipients. This article will review and discuss the performance and limitations of these endogenous markers and their equations as estimators of GFR in the kidney transplant recipients, and their ability in predicting significant clinical outcomes.
Resumo:
The objective of this study was to assess the impact of the filtration method (in situ vs. ex situ) on the dissolved/particulate partitioning of 12 elements in hydrothermal samples collected from the Lucky Strike vent field (Mid-Atlantic Ridge; MAR). To do so, dissolved ( <0.45 mu m) and particulate Mg, Li, Mn, U, V, As, Ba, Fe, Zn, Cd, Pb and Cu were measured using different techniques (HR-ICP-MS, ICP-AES and CCSA). Using in situ filtration as a baseline, we showed that ex situ filtration (on-board and on shore after freezing) resulted in an underestimation of the dissolved pool, which was counterbalanced by an overestimation of the particulate pool for almost all the elements studied. We also showed that on-board filtration was acceptable for the assessment of dissolved and particulate Mn, Mg, Li and U for which the measurement bias for the dissolved fraction did not exceed 3%. However, in situ filtration appeared necessary for the accurate assessment of the dissolved and particulate concentrations of V, As, Fe, Zn, Ba, Cd, Pb and Cu. In the case of Fe, on-board filtration underestimated the dissolved pool by up to 96%. Laboratory filtration (after freezing) resulted in a large bias in the dissolved and particulate concentrations, unambiguously discounting this filtration method for deep-sea chemical speciation studies. We discuss our results in light of the precipitation processes that can potentially affect the accuracy of ex situ filtration methods.
Resumo:
Objective: The aim of this study was to evaluate the correlation between cholesterol levels and the glomerular filtration rate of adult patients in a Portuguese sample.
Resumo:
Today , Providing drinking water and process water is one of the major problems in most countries ; the surface water often need to be treated to achieve necessary quality, and in this way, technological and also financial difficulties cause great restrictions in operating the treatment units. Although water supply by simple and cheap systems has been one of the important objectives in most scientific and research centers in the world, still a great percent of population in developing countries, especially in rural areas, don't benefit well quality water. One of the big and available sources for providing acceptable water is sea water. There are two ways to treat sea water first evaporation and second reverse osmosis system. Nowadays R.O system has been used for desalination because of low budget price and easily to operate and maintenance. The sea water should be pretreated before R.O plants, because there is some difficulties in raw sea water that can decrease yield point of membranes in R.O system. The subject of this research may be useful in this way, and we hope to be able to achieve complete success in design and construction of useful pretreatment systems for R.O plant. One of the most important units in the sea water pretreatment plant is filtration, the conventional method for filtration is pressurized sand filters, and the subject of this research is about new filtration which is called continuous back wash sand filtration (CBWSF). The CBWSF designed and tested in this research may be used more economically with less difficulty. It consists two main parts first shell body and second central part comprising of airlift pump, raw water feeding pipe, air supply hose, backwash chamber and sand washer as well as inlet and outlet connections. The CBWSF is a continuously operating filter, i.e. the filter does not have to be taken out of operation for backwashing or cleaning. Inlet water is fed through the sand bed while the sand bed is moving downwards. The water gets filtered while the sand becomes dirty. Simultaneously, the dirty sand is cleaned in the sand washer and the suspended solids are discharged in backwash water. We analyze the behavior of CBWSF in pretreatment of sea water instead of pressurized sand filter. There is one important factor which is not suitable for R.O membranes, it is bio-fouling. This factor is defined by Silt Density Index (SDI).measured by SDI. In this research has been focused on decreasing of SDI and NTU. Based on this goal, the prototype of pretreatment had been designed and manufactured to test. The system design was done mainly by using the design fundamentals of CBWSF. The automatic backwash sand filter can be used in small and also big water supply schemes. In big water treatment plants, the units of filters perform the filtration and backwash stages separately, and in small treatment plants, the unit is usually compacted to achieve less energy consumption. The analysis of the system showed that it may be used feasibly for water treating, especially for limited population. The construction is rapid, simple and economic, and its performance is high enough because no mobile mechanical part is used in it, so it may be proposed as an effective method to improve the water quality and consequently the hygiene level in the remote places of the country.
Resumo:
This study shows a possibility of using municipal sewage sludge after thermal treatment in the production of a filtering material to water treatment. Due to the fast urbanization and implementation of high standards for effluent in many countries in recent years, the sewage sludge is being produced in an ever increasing amount. Therefore, the use of sludge is a suitable solution for the expected large quantity of sludge. Dehydration of sludge was performed by controlled heating at temperatures of 1100 degrees C, 850 degrees C, 650 degrees C, 350 degrees C for 3 hours. After thermal treatment the sludge was characterized by X-ray fluorescence, TG/DTG/DTA, residue solubilization and residue lixiviation tests. The aim of the present work was to observe, thought the characterization techniques, if the treated sewage sludge is or not adequate to be used as filter material to water treatment. It will be verified which treatment temperature of the sludge offer possibility to its use in water treatment without carrying pollutants in concentrations out of the standards.
Resumo:
The processing of industry and domestic effluents in wastewater treatment plants reduces the amount of polluted material and forms reusable water and dehydrated sludge. the generation of hazardous municipal sludge can be decreased, as well as the impact on surface and underground water and the risk to human health. The aim this study is to verify the possibility to use sintered sewage sludge as support material after thermal treatment in the production of a filtering material to water supply systems. After thermal treatment the sewage sludge ash was characterized by X-ray fluorescence (XRF), leaching test and water solubilization. Dehydration of sludge was performed by controlled heating at temperatures of 180 degrees C, 350 degrees C, 600 degrees C, 850 degrees C and 1000 degrees C for 3 hours.
Resumo:
The objective of the present study was to evaluate the efficiency of the process of biodigestion of the protein concentrate resulting from the ultrafiltration of the effluent from a slaughterhouse freezer of Nile tilapia. Bench digesters were used with excrements and water (control) in comparison with a mixture of cattle manure and effluent from the stages of filleting and bleeding of tilapias. The effluent obtained in the continuous process (bleeding + filleting) was the one with highest accumulated population from the 37th day, as well as greatest daily production. Gases composition did not differ between the protein concentrates, but the gas obtained with the use of the effluent from the filleting stage presented highest methane gas average (78.05%) in comparison with those obtained in the bleeding stage (69.95%) and in the continuous process (70.02%) or by the control method (68.59%).
Resumo:
Background: Diabetes mellitus is the most common cause of end-stage renal disease, which is associated with increased morbidity and mortality. The impact of bariatric surgery on chronic kidney disease is unclear. Objectives: Our primary aim was to assess the impact of bariatric surgery on estimated glomerular filtration rate (eGFR) in type 2 diabetes (T2D) patients. Our secondary aim was to compare the impact of bariatric surgery versus routine care on eGFR in patients with T2D. Setting: University Hospital, United Kingdom. Methods: A retrospective cohort analysis of adults with T2D who underwent bariatric surgery at a single center between January 2005 and December 2012. Data regarding eGFR were obtained from electronic patients records. eGFR was calculated using the Modification of Diet in Renal Disease formula. Data regarding patients with T2D who did not undergo bariatric surgery ("routine care") were obtained from patients attending the diabetes clinic at the same center from 2009 to 2011. Results: One hundred sixty-three patients were included (mean age 48.5±8.8 yr; baseline body mass index 50.8±9.1 kg/m2) and were followed for 3.0±2.3 years. Bariatric surgery resulted in an improvement in eGFR (median [interquartile range] 86.0 [73.0-100.0] versus 92.0 [77.0-101.0] mL/min/1.73 m2 for baseline versus follow-up, respectively; P = .003), particularly in patients with baseline eGFR≤60 mL/min/1.73 m2 (48.0 [42.0-57.0] versus 61.0 [55.0-63.0] mL/min/1.73 m2; P = .004). After adjusting for baseline eGFR, glycated hemoglobin (HbA1C), body mass index, age, and gender, bariatric surgery was associated with higher study-end eGFR compared with routine care (B = 7.787; P< .001). Conclusion: Bariatric surgery results in significant improvements in eGFR in T2D patients, particularly those with an eGFR≤60 mL/min/1.73 m2, while routine care was associated with a decline in eGFR.
Resumo:
La greffe rénale est le meilleur traitement de l’insuffisance rénale terminale. Par contre, la perte prématurée du greffon est un problème majeur chez les greffés qui est due majoritairement au rejet. La classification de Banff reconnait 2 catégories de rejets : une réaction médiée par les anticorps (ABMR) et/ou une réaction cellulaire (TCMR). L’ABMR est caractérisé par le développement de novo d’anticorps contre le donneur (DSA) en circulation et des dommages histologiques, comme la glomérulopathie du transplant. De novo, les DSA anti-HLA-II sont plus fréquemment associés à la glomérulopathie du transplant que les anti-HLA-I et sont associés à un moins bon pronostic clinique. Toutefois, le mécanisme par lequel les anti-HLA-II sont plus dommageables demeure mal connu. Mon hypothèse est que les anticorps anti-HLA sont suffisants pour perturber l’hémostase de l’endothélium glomérulaire. Plus particulièrement, nous croyons que les anticorps anti-HLA-II, diminuent l’expression de la thrombomoduline (TBM), ce qui pourrait mener aux lésions endothéliales glomérulaires associées à la glomérulopathie du transplant. Pour évaluer cette hypothèse, j’ai utilisé un modèle in vitro d’endothélium glomérulaire humain et du sérum de patients transplantés rénaux. Nous avons observé que l’expression membranaire de la TBM augmentait de manière dosedépendante en présence d‘anti-HLA-I, mais pas anti-HLA-II. Toutefois, lors de la mesure intracellulaire nous avons observé une accumulation cytosolique en réponse à une stimulation par les anti-HLA-II. De plus, nous avons observé une association significative entre la présence de DSA circulants anti-HLA-II dans les patients transplantés rénaux et un faible taux de TBM sérique. Ces résultats indiquent que la liaison des anticorps anti-HLA-I et II produit des effets différents sur l’expression endothéliale de la TBM. Les anticorps anti-HLA-II pourraient être associés à un état prothrombotique qui pourrait expliquer l’occurrence plus élevée de lésions microangiopathiques dans l’allogreffe et la moins bonne condition observée chez les patients ayant ces anticorps.
Resumo:
Reports of long-term tenofovir disoproxil fumarate (TDF) treatment in HIV-infected adolescents are limited. We present final results from the open-label (OL) TDF extension following the randomized, placebo (PBO)-controlled, double-blind phase of GS-US-104-0321 (Study 321). HIV-infected 12- to 17-year-olds treated with TDF 300 mg or PBO with an optimized background regimen (OBR) for 24-48 weeks subsequently received OL TDF plus OBR in a single arm study extension. HIV-1 RNA and safety, including bone mineral density (BMD), was assessed in all TDF recipients. Eighty-one subjects received TDF (median duration 96 weeks). No subject died or discontinued OL TDF for safety/tolerability. At week 144, proportions with HIV-1 RNA <50 copies/mL were 30.4% (7 of 23 subjects with baseline HIV-1 RNA >1000 c/mL initially randomized to TDF), 41.7% (5 of 12 subjects with HIV-1 RNA <1000 c/mL who switched PBO to TDF) and 0% (0 of 2 subjects failed randomized PBO plus OBR with HIV-1 RNA >1000 c/mL and switched PBO to TDF). Viral resistance to TDF occurred in 1 subject. At week 144, median decrease in estimated glomerular filtration rate was 38.1 mL/min/1.73 m (n = 25). Increases in median spine (+12.70%, n = 26) and total body less head BMD (+4.32%, n = 26) and height-age adjusted Z-scores (n = 21; +0.457 for spine, +0.152 for total body less head) were observed at week 144. Five of 81 subjects (6%) had persistent >4% BMD decreases from baseline. Some subjects had virologic responses to TDF plus OBR, and TDF resistance was rare. TDF was well tolerated and can be considered for treatment of HIV-infected adolescents.
Resumo:
In this study, we hypothesized that blunting of the natriuresis response to intracerebroventricularly (i.c.v.) microinjected cholinergic and adrenergic agonists is involved in the development of hypertension in spontaneously hypertensive rats (SHR). We evaluated the effect of i.c.v. injection of cholinergic and noradrenergic agonists, at increasing concentrations, and of muscarinic cholinergic and α1 and α2-adrenoceptor antagonists on blood pressure and urinary sodium handling in SHR, compared with age-matched Wistar Kyoto rats (WR). We confirmed that CCh and NE microinjected into the lateral ventricle (LV) of conscious rats leads to enhanced natriuresis. This response was associated with increased proximal and post-proximal sodium excretion accompanied by an unchanged rate of glomerular filtration. We showed that cholinergic-induced natriuresis in WR and SHR was attenuated by previous i.c.v. administration of atropine and was significantly lower in the hypertensive strain than in WR. In both groups the natriuretic effect of injection of noradrenaline into the LV was abolished by previous local injection of an α1-adrenoceptor antagonist (prazosin). Conversely, LV α2-adrenoceptor antagonist (yohimbine) administration potentiated the action of noradrenaline. The LV yohimbine pretreatment normalized urinary sodium excretion in SHR compared with age-matched WR. In conclusion, these are, as far as we are aware, the first results showing the importance of interaction of central cholinergic and/or noradrenergic receptors in the pathogenesis of spontaneous hypertension. These experiments also provide good evidence of the existence of a central adrenergic mechanism consisting of α1 and α2-adrenoceptors which works antagonistically on regulation of renal sodium excretion.
Resumo:
Inductively Coupled Plasma Optical Emission Spectrometry was used to determine Ca, Mg, Mn, Fe, Zn and Cu in samples of processed and natural coconut water. The sample preparation consisted in a filtration step followed by a dilution. The analysis was made employing optimized instrumental parameters and the results were evaluated using methods of Pattern Recognition. The data showed common concentration values for the analytes present in processed and natural samples. Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA) indicated that the samples of different kinds were statistically different when the concentrations of all the analytes were considered simultaneously.
Resumo:
The application of sand filters in localized irrigation systems is recommended in the presence of organic and algae contamination. The proper design and maintenance of these equipments are essential to assure an effective water quality control, in order to reduce the emitters clogging, to keep its water application uniformity, and to prevent increasing in the system operation costs. Despite the existence of some references about design, operation and maintenance of these filters, they are dispersed, with not enough details to guarantee the optimization of its hydraulics structure design and the proper selection of porous media to be used. Therefore, the objective of this work was to report a current literature review, relating practical information with scientific knowledge. The content of this review would help to induce and intensify the research on this subject and to contribute so the operational functions for the equipment are reached. It is also expected to assist the improvement of the filtration and flushing processes in the agricultural irrigation and the development of original design procedures and the rational use of these devices.
Resumo:
Culture supernatant of Staphylococcus aureus 722 in 3% triptone plus 1% yeast extract was used for EEA purification, proceeding comparison between dye ligand Red A affinity chromatography and classic chromatography. The capture of SEA with Amberlite CG-50 allowed rapid enterotoxin concentration from the culture supernatant. However, the ratio of 15 mg of the resin to a total of 150 mg of the toxin satured the resin, giving only 10 to 30% of SEA recuperation from the supernatant. The elution of concentrated material throught the Red A column resulted in a recovery of 60,87% of the toxin, and required 76 hours, indicating advantage on classic chromatography. Ion exchange column plus gel filtration recovered only 6,5 % of the SEA, and required 114 hours to conclude the procedure. The eletrophoresis of purified SEA indicated high grade of toxin obtained from Red A column, with 90 % of purity, compared to 60 % of classic column.