953 resultados para Fault-tolerant control
Resumo:
This work describes different possibilities of protection and control system improvement of primary distribution substation. The status of condition and main problems of power networks from reliability point of view in Russia are described. This work studies technologies used today in Russia for protection of distribution networks with their disadvantages. Majority of medium voltage networks (6-35 kV) has isolated network point. There is still no any protection available on the market which allows to estimate distance to fault in case of earth fault. The thesis analyses methods of earth fault distance calculation. On the basis of computer simulation the influence of various factors on calculation accuracy is studied. The practical implementation of the method presupposes usage of digital relay. Application of digital relay is accompanied by numerous opportunities which are described in this work. Also advantages of system implemented on the basis of IEC 61850 standard are examined. Finally, suitability of modern digital relays from GOST standard point of view is analyzed.
Resumo:
One of the techniques used to detect faults in dynamic systems is analytical redundancy. An important difficulty in applying this technique to real systems is dealing with the uncertainties associated with the system itself and with the measurements. In this paper, this uncertainty is taken into account by the use of intervals for the parameters of the model and for the measurements. The method that is proposed in this paper checks the consistency between the system's behavior, obtained from the measurements, and the model's behavior; if they are inconsistent, then there is a fault. The problem of detecting faults is stated as a quantified real constraint satisfaction problem, which can be solved using the modal interval analysis (MIA). MIA is used because it provides powerful tools to extend the calculations over real functions to intervals. To improve the results of the detection of the faults, the simultaneous use of several sliding time windows is proposed. The result of implementing this method is semiqualitative tracking (SQualTrack), a fault-detection tool that is robust in the sense that it does not generate false alarms, i.e., if there are false alarms, they indicate either that the interval model does not represent the system adequately or that the interval measurements do not represent the true values of the variables adequately. SQualTrack is currently being used to detect faults in real processes. Some of these applications using real data have been developed within the European project advanced decision support system for chemical/petrochemical manufacturing processes and are also described in this paper
Resumo:
The weed Borreria densiflora is a management issue in soybean and sugarcane crops from North and Northeastern Brazil. Knowledge upon chemical control of B. densiflora contributes to the integrated management of this weed species, especially when active ingredient options become reduced due to the selection of herbicide resistant or tolerant weed species. Experiments in pre- and post-emergence of B. densiflora were conducted in greenhouse, in a randomized block design and four replications. In pre-emergence, the dose-response curve methodology was used and 7 herbicides were tested. In post-emergence, 9 herbicides at the recommended rate and 4 herbicide mixtures were tested. For pre and post-emergence conditions, evaluations were conducted at 60 and 21 days after treatment (DAT), respectively, and the variables analyzed were weed control and dry weight (%). The results showed options of pre-emergent herbicides that can be used for controlling B. densiflora, especially in sugarcane, where chemical weed control is mainly based on pre-emergent applications. In the current glyphosate resistance scenario, one should consider the use of pre-emergent herbicides within an integrated management of B. densiflora. For satisfactory post-emergence control, B. densiflora plants should be sprayed at the phenological stage of up to three pairs of leaves. Herbicide mixtures have been and will continue to be an important tool in chemical weed management, broadening the spectrum of weed control, while diversifying herbicide mechanisms of action, which helps to prevent or delay the appearance of herbicide resistance.
Resumo:
This study aimed to control different populations of Digitaria insularisby glyphosate herbicide, isolated and mixed, besides the combination of methods (chemical and mechanical) to manage resistant adult plants. Three experiments were conducted, one in pots which were maintained under non-controlled conditions and two under field conditions. In the experiment in pots, twelve populations of D. insularis were sprayed with isolated glyphosate (1.44 and 2.16 kg a.e. ha-1) and mixed (1.44 and 2.16 kg a.e. ha-1) with quizalofop-p tefuryl (0.12 kg i.a. ha-1). The treatment of 1.44 kg a.e. ha-1 of glyphosate plus 0.12 kg a.i. ha-1 of quizalofop was sufficient for adequate control (>95%) of all populations. Population 11 (area of grain production in Itumbiara, GO) was considered sensitive to glyphosate. Others populations were moderately sensitive or tolerant to the herbicide. In the field, the plants of D. insularis of one of the experiments were mowed and, in the other, there were not. Eight treatments with herbicides [isolated glyphosate (1.44 and 2.16 kg a.e. ha-1) and mixed (1.44 and 2.16 kg a.e. ha-1) with quizalofop-p-tefuryl at 0.12 kg a.i. ha-1), clethodim at 0.108 kg a.i. ha-1) or nicosulfuron at 0.06 kg a.i. ha-1)] were assessed, in combination with or without sequential application of the standard treatment, sprayed 15 days after the first application. The combination of the mechanic control with the application of glyphosate (2.16 and 1.44 kg a.e. ha-1) plus quizalofop-p-tefuryl (0.12 kg a.i. ha-1) or clethodim (0.108 kg a.i. ha-1), associated to the sequential application, was the most effective strategy for the management of adult plants of resistant D. insularis.
Resumo:
ABSTRACTWhite clover is tolerant to many herbicides, making difficult a chemical control of this species during soybean crop establishments. The objective of this research was to select herbicides applied postemergence to control white clover in soybean and know the effects of this control on soybean yield. Seven herbicides were assessed, applied postemergence, with or without sequential application of glyphosate, and two control treatments (no control and total control of white clover). Glyphosate (with two sequential applications), fomesafen (with a sequential application of glyphosate), chlorimuron-ethyl and lactofen have shown a satisfactory control of white clover (above 80%). The lower control efficiency has resulted in lower production of soybeans.
Resumo:
In order to identify early abnormalities in non-insulin-dependent diabetes mellitus (NIDDM) we determined insulin (using an assay that does not cross-react with proinsulin) and proinsulin concentrations. The proinsulin/insulin ratio was used as an indicator of abnormal ß-cell function. The ratio of the first 30-min increase in insulin to glucose concentrations following the oral glucose tolerance test (OGTT; I30-0/G30-0) was taken as an indicator of insulin secretion. Insulin resistance (R) was evaluated by the homeostasis model assessment (HOMA) method. True insulin and proinsulin were measured during a 75-g OGTT in 35 individuals: 20 with normal glucose tolerance (NGT) and without diabetes among their first-degree relatives (FDR) served as controls, and 15 with NGT who were FDR of patients with NIDDM. The FDR group presented higher insulin (414 pmol/l vs 195 pmol/l; P = 0.04) and proinsulin levels (19.6 pmol/l vs 12.3 pmol/l; P = 0.03) post-glucose load than the control group. When these groups were stratified according to BMI, the obese FDR (N = 8) showed higher fasting and post-glucose insulin levels than the obese NGT (N = 9) (fasting: 64.8 pmol/l vs 7.8 pmol/l; P = 0.04, and 60 min post-glucose: 480.6 pmol/l vs 192 pmol/l; P = 0.01). Also, values for HOMA (R) were higher in the obese FDR compared to obese NGT (2.53 vs 0.30; P = 0.075). These results show that FDR of NIDDM patients have true hyperinsulinemia (which is not a consequence of cross-reactivity with proinsulin) and hyperproinsulinemia and no dysfunction of a qualitative nature in ß-cells.
Resumo:
Tolerance to lipopolysaccharide (LPS) occurs when animals or cells exposed to LPS become hyporesponsive to a subsequent challenge with LPS. This mechanism is believed to be involved in the down-regulation of cellular responses observed in septic patients. The aim of this investigation was to evaluate LPS-induced monocyte tolerance of healthy volunteers using whole blood. The detection of intracellular IL-6, bacterial phagocytosis and reactive oxygen species (ROS) was determined by flow cytometry, using anti-IL-6-PE, heat-killed Staphylococcus aureus stained with propidium iodide and 2',7'-dichlorofluorescein diacetate, respectively. Monocytes were gated in whole blood by combining FSC and SSC parameters and CD14-positive staining. The exposure to increasing LPS concentrations resulted in lower intracellular concentration of IL-6 in monocytes after challenge. A similar effect was observed with challenge with MALP-2 (a Toll-like receptor (TLR)2/6 agonist) and killed Pseudomonas aeruginosa and S. aureus, but not with flagellin (a TLR5 agonist). LPS conditioning with 15 ng/mL resulted in a 40% reduction of IL-6 in monocytes. In contrast, phagocytosis of P. aeruginosa and S. aureus and induced ROS generation were preserved or increased in tolerant cells. The phenomenon of tolerance involves a complex regulation in which the production of IL-6 was diminished, whereas the bacterial phagocytosis and production of ROS was preserved. Decreased production of proinflammatory cytokines and preserved or increased production of ROS may be an adaptation to control the deleterious effects of inflammation while preserving antimicrobial activity.
Resumo:
One of the techniques used to detect faults in dynamic systems is analytical redundancy. An important difficulty in applying this technique to real systems is dealing with the uncertainties associated with the system itself and with the measurements. In this paper, this uncertainty is taken into account by the use of intervals for the parameters of the model and for the measurements. The method that is proposed in this paper checks the consistency between the system's behavior, obtained from the measurements, and the model's behavior; if they are inconsistent, then there is a fault. The problem of detecting faults is stated as a quantified real constraint satisfaction problem, which can be solved using the modal interval analysis (MIA). MIA is used because it provides powerful tools to extend the calculations over real functions to intervals. To improve the results of the detection of the faults, the simultaneous use of several sliding time windows is proposed. The result of implementing this method is semiqualitative tracking (SQualTrack), a fault-detection tool that is robust in the sense that it does not generate false alarms, i.e., if there are false alarms, they indicate either that the interval model does not represent the system adequately or that the interval measurements do not represent the true values of the variables adequately. SQualTrack is currently being used to detect faults in real processes. Some of these applications using real data have been developed within the European project advanced decision support system for chemical/petrochemical manufacturing processes and are also described in this paper
Resumo:
This paper deals with fault detection and isolation problems for nonlinear dynamic systems. Both problems are stated as constraint satisfaction problems (CSP) and solved using consistency techniques. The main contribution is the isolation method based on consistency techniques and uncertainty space refining of interval parameters. The major advantage of this method is that the isolation speed is fast even taking into account uncertainty in parameters, measurements, and model errors. Interval calculations bring independence from the assumption of monotony considered by several approaches for fault isolation which are based on observers. An application to a well known alcoholic fermentation process model is presented
Resumo:
Fault location has been studied deeply for transmission lines due to its importance in power systems. Nowadays the problem of fault location on distribution systems is receiving special attention mainly because of the power quality regulations. In this context, this paper presents an application software developed in Matlabtrade that automatically calculates the location of a fault in a distribution power system, starting from voltages and currents measured at the line terminal and the model of the distribution power system data. The application is based on a N-ary tree structure, which is suitable to be used in this application due to the highly branched and the non- homogeneity nature of the distribution systems, and has been developed for single-phase, two-phase, two-phase-to-ground, and three-phase faults. The implemented application is tested by using fault data in a real electrical distribution power system
Resumo:
Not considered in the analytical model of the plant, uncertainties always dramatically decrease the performance of the fault detection task in the practice. To cope better with this prevalent problem, in this paper we develop a methodology using Modal Interval Analysis which takes into account those uncertainties in the plant model. A fault detection method is developed based on this model which is quite robust to uncertainty and results in no false alarm. As soon as a fault is detected, an ANFIS model is trained in online to capture the major behavior of the occurred fault which can be used for fault accommodation. The simulation results understandably demonstrate the capability of the proposed method for accomplishing both tasks appropriately
Resumo:
ABSRACT This thesis focuses on the monitoring, fault detection and diagnosis of Wastewater Treatment Plants (WWTP), which are important fields of research for a wide range of engineering disciplines. The main objective is to evaluate and apply a novel artificial intelligent methodology based on situation assessment for monitoring and diagnosis of Sequencing Batch Reactor (SBR) operation. To this end, Multivariate Statistical Process Control (MSPC) in combination with Case-Based Reasoning (CBR) methodology was developed, which was evaluated on three different SBR (pilot and lab-scales) plants and validated on BSM1 plant layout.
Resumo:
Les noves tecnologies a la xarxa ens permeten transportar, cada cop més, grans volums d' informació i trànsit de xarxa amb diferents nivells de prioritat. En aquest escenari, on s'ofereix una millor qualitat de servei, les conseqüències d'una fallada en un enllaç o en un node esdevenen més importants. Multiprotocol Lavel Switching (MPLS), juntament amb l'extensió a MPLS generalitzat (GMPLS), proporcionen mecanismes ràpids de recuperació de fallada establint camins, Label Switch Path (LSPs), redundants per ser utilitzats com a camins alternatius. En cas de fallada podrem utilitzar aquests camins per redireccionar el trànsit. El principal objectiu d'aquesta tesi ha estat millorar alguns dels actuals mecanismes de recuperació de fallades MPLS/GMPLS, amb l'objectiu de suportar els requeriments de protecció dels serveis proporcionats per la nova Internet. Per tal de fer aquesta avaluació s'han tingut en compte alguns paràmetres de qualitat de protecció com els temps de recuperació de fallada, les pèrdues de paquets o el consum de recursos. En aquesta tesi presentem una completa revisió i comparació dels principals mètodes de recuperació de fallada basats en MPLS. Aquest anàlisi inclou els mètodes de protecció del camí (backups globals, backups inversos i protecció 1+1), els mètodes de protecció locals i els mètodes de protecció de segments. També s'ha tingut en compte l'extensió d'aquests mecanismes a les xarxes òptiques mitjançant el pla de control proporcionat per GMPLS. En una primera fase d'aquest treball, cada mètode de recuperació de fallades és analitzat sense tenir en compte restriccions de recursos o de topologia. Aquest anàlisi ens dóna una primera classificació dels millors mecanismes de protecció en termes de pèrdues de paquets i temps de recuperació. Aquest primer anàlisi no és aplicable a xarxes reals. Per tal de tenir en compte aquest nou escenari, en una segona fase, s'analitzen els algorismes d'encaminament on sí tindrem en compte aquestes limitacions i restriccions de la xarxa. Es presenten alguns dels principals algorismes d'encaminament amb qualitat de servei i alguna de les principals propostes d'encaminament per xarxes MPLS. La majoria dels actual algorismes d'encaminament no tenen en compte l'establiment de rutes alternatives o utilitzen els mateixos objectius per seleccionar els camins de treball i els de protecció. Per millorar el nivell de protecció introduïm i formalitzem dos nous conceptes: la Probabilitat de fallada de la xarxa i l'Impacte de fallada. Un anàlisi de la xarxa a nivell físic proporciona un primer element per avaluar el nivell de protecció en termes de fiabilitat i disponibilitat de la xarxa. Formalitzem l'impacte d'una fallada, quant a la degradació de la qualitat de servei (en termes de retard i pèrdues de paquets). Expliquem la nostra proposta per reduir la probabilitat de fallada i l'impacte de fallada. Per últim fem una nova definició i classificació dels serveis de xarxa segons els valors requerits de probabilitat de fallada i impacte. Un dels aspectes que destaquem dels resultats d'aquesta tesi és que els mecanismes de protecció global del camí maximitzen la fiabilitat de la xarxa, mentre que les tècniques de protecció local o de segments de xarxa minimitzen l'impacte de fallada. Per tant podem assolir mínim impacte i màxima fiabilitat aplicant protecció local a tota la xarxa, però no és una proposta escalable en termes de consum de recursos. Nosaltres proposem un mecanisme intermig, aplicant protecció de segments combinat amb el nostre model d'avaluació de la probabilitat de fallada. Resumint, aquesta tesi presenta diversos mecanismes per l'anàlisi del nivell de protecció de la xarxa. Els resultats dels models i mecanismes proposats milloren la fiabilitat i minimitzen l'impacte d'una fallada en la xarxa.
Resumo:
Les restriccions reals quantificades (QRC) formen un formalisme matemàtic utilitzat per modelar un gran nombre de problemes físics dins els quals intervenen sistemes d'equacions no-lineals sobre variables reals, algunes de les quals podent ésser quantificades. Els QRCs apareixen en nombrosos contextos, com l'Enginyeria de Control o la Biologia. La resolució de QRCs és un domini de recerca molt actiu dins el qual es proposen dos enfocaments diferents: l'eliminació simbòlica de quantificadors i els mètodes aproximatius. Tot i això, la resolució de problemes de grans dimensions i del cas general, resten encara problemes oberts. Aquesta tesi proposa una nova metodologia aproximativa basada en l'Anàlisi Intervalar Modal, una teoria matemàtica que permet resoldre problemes en els quals intervenen quantificadors lògics sobre variables reals. Finalment, dues aplicacions a l'Enginyeria de Control són presentades. La primera fa referència al problema de detecció de fallades i la segona consisteix en un controlador per a un vaixell a vela.
Resumo:
El desalineamiento temporal es la incorrespondencia de dos señales debido a una distorsión en el eje temporal. La Detección y Diagnóstico de Fallas (Fault Detection and Diagnosis-FDD) permite la detección, el diagnóstico y la corrección de fallos en un proceso. La metodología usada en FDD está dividida en dos categorías: técnicas basadas en modelos y no basadas en modelos. Esta tesis doctoral trata sobre el estudio del efecto del desalineamiento temporal en FDD. Nuestra atención se enfoca en el análisis y el diseño de sistemas FDD en caso de problemas de comunicación de datos, como retardos y pérdidas. Se proponen dos técnicas para reducir estos problemas: una basada en programación dinámica y la otra en optimización. Los métodos propuestos han sido validados sobre diferentes sistemas dinámicos: control de posición de un motor de corriente continua, una planta de laboratorio y un problema de sistemas eléctricos conocido como hueco de tensión.