458 resultados para Eveline Hasler
Resumo:
Purpose To compare changes in the largest cross-sectional area (CSA) of the median nerve in wrists undergoing surgical decompression with changes in wrists undergoing non-surgical treatment of carpal tunnel syndrome (CTS). Methods This study was a prospective cohort study in 55 consecutive patients with 78 wrists with established CTS, including 60 wrists treated with surgical decompression and 18 wrists with non-surgical treatment. A sonographic examination was scheduled before and 4 months after initiation of treatment. We compared changes in CSA of the median nerve between wrists with surgical treatment and wrists with non-surgical treatment using linear regression models. Results Decreases in CSA of the median nerve were more pronounced in wrists with CTS release than in wrists undergoing nonsurgical treatment (difference in means, 1.0 mm2; 95% confidence interval, 0.3–1.8 mm2). Results were robust to the adjustment for age, gender, and neurological severity at baseline. Among wrists with CTS release, those with postoperative CSA of 10 mm2 or less tended to have better clinical outcomes than those with postoperative CSA of greater than 10 mm2 (p=.055). Postoperative sonographic workup in the 3 patients with unfavorable outcome or recurrence identified likely causes for treatment failure in 2 patients. Conclusions In this observational study, surgical decompression was associated with a greater decrease in median nerve CSA than was nonsurgical treatment. Smaller postoperative CSAs may be associated with better clinical outcomes. Additional randomized trials are necessary to determine the optimal treatment strategy in different subgroups of patients with CTS. Type of study/level of evidence Therapeutic III.
Resumo:
Bone pathologies as detected on MRI are associated with the presence of pain in knee osteoarthritis (OA). The authors examined whether bone attrition assessed on x-rays was associated with pain, stiffness and disability.
Resumo:
OBJECTIVE: To determine the effect of glucosamine, chondroitin, or the two in combination on joint pain and on radiological progression of disease in osteoarthritis of the hip or knee. Design Network meta-analysis. Direct comparisons within trials were combined with indirect evidence from other trials by using a Bayesian model that allowed the synthesis of multiple time points. MAIN OUTCOME MEASURE: Pain intensity. Secondary outcome was change in minimal width of joint space. The minimal clinically important difference between preparations and placebo was prespecified at -0.9 cm on a 10 cm visual analogue scale. DATA SOURCES: Electronic databases and conference proceedings from inception to June 2009, expert contact, relevant websites. Eligibility criteria for selecting studies Large scale randomised controlled trials in more than 200 patients with osteoarthritis of the knee or hip that compared glucosamine, chondroitin, or their combination with placebo or head to head. Results 10 trials in 3803 patients were included. On a 10 cm visual analogue scale the overall difference in pain intensity compared with placebo was -0.4 cm (95% credible interval -0.7 to -0.1 cm) for glucosamine, -0.3 cm (-0.7 to 0.0 cm) for chondroitin, and -0.5 cm (-0.9 to 0.0 cm) for the combination. For none of the estimates did the 95% credible intervals cross the boundary of the minimal clinically important difference. Industry independent trials showed smaller effects than commercially funded trials (P=0.02 for interaction). The differences in changes in minimal width of joint space were all minute, with 95% credible intervals overlapping zero. Conclusions Compared with placebo, glucosamine, chondroitin, and their combination do not reduce joint pain or have an impact on narrowing of joint space. Health authorities and health insurers should not cover the costs of these preparations, and new prescriptions to patients who have not received treatment should be discouraged.
Resumo:
Background Osteoarthritis is the most common form of joint disorder and a leading cause of pain and physical disability. Observational studies suggested a benefit for joint lavage, but recent, sham-controlled trials yielded conflicting results, suggesting joint lavage not to be effective. Objectives To compare joint lavage with sham intervention, placebo or non-intervention control in terms of effects on pain, function and safety outcomes in patients with knee osteoarthritis. Search methods We searched CENTRAL, MEDLINE, EMBASE, and CINAHL up to 3 August 2009, checked conference proceedings, reference lists, and contacted authors. Selection criteria We included studies if they were randomised or quasi-randomised trials that compared arthroscopic and non-arthroscopic joint lavage with a control intervention in patients with osteoarthritis of the knee. We did not apply any language restrictions. Data collection and analysis Two independent review authors extracted data using standardised forms. We contacted investigators to obtain missing outcome information. We calculated standardised mean differences (SMDs) for pain and function, and risk ratios for safety outcomes. We combined trials using inverse-variance random-effects meta-analysis. Main results We included seven trials with 567 patients. Three trials examined arthroscopic joint lavage, two non-arthroscopic joint lavage and two tidal irrigation. The methodological quality and the quality of reporting was poor and we identified a moderate to large degree of heterogeneity among the trials (I2 = 65%). We found little evidence for a benefit of joint lavage in terms of pain relief at three months (SMD -0.11, 95% CI -0.42 to 0.21), corresponding to a difference in pain scores between joint lavage and control of 0.3 cm on a 10-cm visual analogue scale (VAS). Results for improvement in function at three months were similar (SMD -0.10, 95% CI -0.30 to 0.11), corresponding to a difference in function scores between joint lavage and control of 0.2 cm on a WOMAC disability sub-scale from 0 to 10. For pain, estimates of effect sizes varied to some degree depending on the type of lavage, but this variation was likely to be explained by differences in the credibility of control interventions: trials using sham interventions to closely mimic the process of joint lavage showed a null-effect. Reporting on adverse events and drop out rates was unsatisfactory, and we were unable to draw conclusions for these secondary outcomes. Authors' conclusions Joint lavage does not result in a relevant benefit for patients with knee osteoarthritis in terms of pain relief or improvement of function.
Resumo:
Osteoarthritis is the most common form of joint disease and the leading cause of pain and physical disability in the elderly. Therapeutic ultrasound is one of several physical therapy modalities suggested for the management of pain and loss of function due to osteoarthritis (OA).
Resumo:
High protein diets have been shown to improve hepatic steatosis in rodent models and in high-fat fed humans. We therefore evaluated the effects of a protein supplementation on intrahepatocellular lipids (IHCL), and fasting plasma triglycerides in obese non diabetic women.
Resumo:
Pathological complete response (pCR) to neoadjuvant treatment correlates with outcome in breast cancer. We determined whether characteristics of neoadjuvant therapy are associated with pCR. We used multi-level models, which accounted for heterogeneity in pCR across trials and trial arms, to analyze individual patient data from 3332 women included in 7 German neoadjuvant trials with uniform protocols. PCR was associated with an increase in number of chemotherapy cycles (odds ratio [OR] 1.2 for every two additional cycles; P = 0.009), with higher cumulative anthracycline doses (OR 1.6; P = 0.002), higher cumulative taxane doses (OR 1.6; P = 0.009), and with capecitabine containing regimens (OR 1.62; P = 0.022). Association of pCR with increase in number of cycles appeared more pronounced in hormone receptor (HR)-positive tumors (OR 1.35) than in HR-negative tumors (OR 1.04; P for interaction = 0.046). Effect of anthracycline dose was particularly pronounced in HER2-negative tumors (OR 1.61), compared to HER2-positive tumors (OR 0.83; P for interaction = 0.14). Simultaneous trastuzumab treatment in HER2-positive tumors increased odds of pCR 3.2-fold (P < 0.001). No association of pCR and number of trastuzumab cycles was found (OR 1.20, P = 0.39). Dosing characteristics appear important for successful treatment of breast cancer. Longer treatment, higher cumulative doses of anthracyclines and taxanes, and the addition of capecitabine and trastuzumab are associated with better response. Tailoring according to breast cancer phenotype might be possible: longer treatment in HR-positive tumors, higher cumulative anthracycline doses for HER2-negative tumors, shorter treatment at higher cumulative doses for triple-negative tumors, and limited number of preoperative trastuzumab cycles in HER2-positive tumors.
Resumo:
Diagnostic and therapeutic approaches to trauma patients are, depending on experience, equipment and different therapeutic doctrines, subject to wide variations. The ability to compare trauma centres using a standardised trauma register helps to reveal unresolved systemic issues and simplifies the quality management in an Emergency Department (ED).
Resumo:
Objectives This study sought to compare the unrestricted use of everolimus-eluting stents (EES) with sirolimus-eluting stents (SES) in patients undergoing percutaneous coronary intervention. Background It is unclear whether there are differences in safety and efficacy between EES and SES during long-term follow-up. Methods Using propensity score matching, clinical outcome was compared among 1,342 propensity score–matched pairs of patients treated with EES and SES. The primary outcome was a composite of death, MI, and target vessel revascularization. Results The median follow-up was 1.5 years with a maximum of 3 years. The primary outcome occurred in 14.9% of EES- and 18.0% of SES-treated patients up to 3 years (hazard ratio [HR]: 0.83, 95% confidence interval [CI]: 0.68 to 1.00, p = 0.056). All-cause mortality (6.0% vs. 6.5%, HR: 0.92, 95% CI: 0.68 to 1.25, p = 0.59) was similar, risks of myocardial infarction (MI) (3.3% vs. 5.0%, HR: 0.62, 95% CI: 0.42 to 0.92, p = 0.017), and target vessel revascularization (7.0% vs. 9.6%, HR: 0.75, 95% CI: 0.57 to 0.99, p = 0.039) were lower with EES than SES. Definite stent thrombosis (ST) (HR: 0.30, 95% CI: 0.12 to 0.75, p = 0.01) was less frequent among patients treated with EES. The reduced rate of MI with EES was explained in part by the lower risk of definite ST and the corresponding decrease in events associated with ST (HR: 0.25, 95% CI: 0.08 to 0.75, p = 0.013). Conclusions The unrestricted use of EES appears to be associated with improved clinical long-term outcome compared with SES. Differences in favor of EES are driven in part by a lower risk of MI associated with ST.
Resumo:
The spine is a complex structure that provides motion in three directions: flexion and extension, lateral bending and axial rotation. So far, the investigation of the mechanical and kinematic behavior of the basic unit of the spine, a motion segment, is predominantly a domain of in vitro experiments on spinal loading simulators. Most existing approaches to measure spinal stiffness intraoperatively in an in vivo environment use a distractor. However, these concepts usually assume a planar loading and motion. The objective of our study was to develop and validate an apparatus, that allows to perform intraoperative in vivo measurements to determine both the applied force and the resulting motion in three dimensional space. The proposed setup combines force measurement with an instrumented distractor and motion tracking with an optoelectronic system. As the orientation of the applied force and the three dimensional motion is known, not only force-displacement, but also moment-angle relations could be determined. The validation was performed using three cadaveric lumbar ovine spines. The lateral bending stiffness of two motion segments per specimen was determined with the proposed concept and compared with the stiffness acquired on a spinal loading simulator which was considered to be gold standard. The mean values of the stiffness computed with the proposed concept were within a range of ±15% compared to data obtained with the spinal loading simulator under applied loads of less than 5 Nm.