935 resultados para Equipment Approval.
Resumo:
During the mid 80 19s and the early 90 19s the Banking sector of the CEMAC sub-region experienced crisis. This could be seen from the numerous liquidation of Banks within the sub-region during this period, microfinance establishments found a place as an alternative financial institution involved in the provision of savings and loans to the masses. The exercise of the activities of microfinance necessitates an application for approval form the monetary authority. Their potential managers and auditors must equally apply and obtain a license before functioning. After this approval has been obtained the microfinance establishment must register with the National Credit Council and the Trade and Personal Property Credit Register. // Durant les années 80 et au début des années 90 le secteur Bancaire de la sous-région CEMAC on vécue une crise, ceci pouvait ce voit par de nombreuse liquidation des Banques au sein de la sous-région pendant cette période. Les Etablissement de Micro finance ont trouve une place comme une institution financière alternative s’impliquant dans la fourniture de l’épargne et des prêts pour la masses. Mais l'exercice de l'activité de microfinance exige une demande d'agrément remise par l'autorité monétaire après confirmation de la commission bancaire. Mais avant que cet agrément soit remis, ils doivent fournir certain documents et informations. Les microfinances sont également oblige de fournir certaines documents et information s'il veut offrir un agence dans un du état membre de la CEMAC. Quand cette agrément est remise il sont les obligations administrative et professionnelle a remplir. Ceci consiste de s’inscrire auprès du Conseil National du Crédit et le Registre du Commerce et du Crédit Mobilier, adhérer a une Association Professionnelle, mais ils sont le choix adhérer à un réseau ou de poursuivre les activités indépendamment. L'autorité monétaire peut unilatéralement retrait la décision d'agrément pour un raison ou l'autre. Cependant, la décision de retrait de l'agrément est assujettir à un appel devant le conseil d'administration de la BEAC. La commission bancaire a prévu un ensemble de sanctions pour s'assurer que une personne ou établissement en défaut soit appelle en ordre. // Cameroon, Micro-finance, CEMAC, COBAC, Legislation
Resumo:
AIMS: To describe the procedural performance and 30-day outcomes following implantation using the 18 Fr CoreValve Revalving System (CRS) as part of the multicentre, expanded evaluation registry, 1-year after obtaining CE mark approval. METHODS AND RESULTS: Patients with symptomatic severe aortic stenosis and logistic Euroscore > or =15%, or age > or =75 years, or age > or =65 years associated with pre-defined risk factors, and for whom a physician proctor and a clinical specialist were in attendance during the implantation and who collected the clinical data, were included. From April 2007, to April 2008, 646 patients with a mean age of 81 +/- 6.6 years, mean aortic valve area 0.6 +/- 0.2 cm2, and logistic EuroSCORE of 23.1 +/- 13.8% were recruited. After valve implantation, the mean transaortic valve gradient decreased from 49.4 +/- 13.9 to 3 +/- 2 mmHg. All patients had paravalvular aortic regurgitation < or = grade 2. The rate of procedural success was 97%. The procedural mortality rate was 1.5%. At 30 days, the all-cause mortality rate (i.e, including procedural) was 8% and the combined rate of death, stroke and myocardial infarction was 9.3%. CONCLUSIONS: The results of this study demonstrate the high rate of procedural success and a low 30-day mortality in a large cohort of high-risk patients undergoing transcatheter aortic valve implantation (TAVI) with the CRS.
Resumo:
The purpose of this study is to provide a procedure to include emissions to the atmosphere resulting from the combustion of diesel fuel during dredging operations into the decision-making process of dredging equipment selection. The proposed procedure is demonstrated for typical dredging methods and data from the Illinois Waterway as performed by the U.S. Army Corps of Engineers, Rock Island District. The equipment included in this study is a 16-inch cutterhead pipeline dredge and a mechanical bucket dredge used during the 2005 dredging season on the Illinois Waterway. Considerable effort has been put forth to identify and reduce environmental impacts from dredging operations. Though environmental impacts of dredging have been studied no efforts have been applied to the evaluation of air emissions from comparable types of dredging equipment, as in this study. By identifying the type of dredging equipment with the lowest air emissions, when cost, site conditions, and equipment availability are comparable, adverse environmental impacts can be minimized without compromising the dredging project. A total of 48 scenarios were developed by varying the dredged material quantity, transport distance, and production rates. This produced an “envelope” of results applicable to a broad range of site conditions. Total diesel fuel consumed was calculated using standard cost estimating practices as defined in the U.S. Army Corps of Engineers Construction Equipment Ownership and Operating Expense Schedule (USACE, 2005). The diesel fuel usage was estimated for all equipment used to mobilize and/or operate each dredging crew for every scenario. A Limited Life Cycle Assessment (LCA) was used to estimate the air emissions from two comparable dredging operations utilizing SimaPro LCA software. An Environmental Impact Single Score (EISS) was the SimaPro output selected for comparison with the cost per CY of dredging, potential production rates, and transport distances to identify possible decision points. The total dredging time was estimated for each dredging crew and scenario. An average hourly cost for both dredging crews was calculated based on Rock Island District 2005 dredging season records (Graham 2007/08). The results from this study confirm commonly used rules of thumb in the dredging industry by indicating that mechanical bucket dredges are better suited for long transport distances and have lower air emissions and cost per CY for smaller quantities of dredged material. In addition, the results show that a cutterhead pipeline dredge would be preferable for moderate and large volumes of dredged material when no additional booster pumps are required. Finally, the results indicate that production rates can be a significant factor when evaluating the air emissions from comparable dredging equipment.
Resumo:
BACKGROUND: Only data of published study results are available to the scientific community for further use such as informing future research and synthesis of available evidence. If study results are reported selectively, reporting bias and distortion of summarised estimates of effect or harm of treatments can occur. The publication and citation of results of clinical research conducted in Germany was studied. METHODS: The protocols of clinical research projects submitted to the research ethics committee of the University of Freiburg (Germany) in 2000 were analysed. Published full articles in several databases were searched and investigators contacted. Data on study and publication characteristics were extracted from protocols and corresponding publications. RESULTS: 299 study protocols were included. The most frequent study design was randomised controlled trial (141; 47%), followed by uncontrolled studies (61; 20%), laboratory studies (30; 10%) and non-randomised studies (29; 10%). 182 (61%) were multicentre studies including 97 (53%) international collaborations. 152 of 299 (51%) had commercial (co-)funding and 46 (15%) non-commercial funding. 109 of the 225 completed protocols corresponded to at least one full publication (total 210 articles); the publication rate was 48%. 168 of 210 identified publications (80%) were cited in articles indexed in the ISI Web of Science. The median was 11 citations per publication (range 0-1151). CONCLUSIONS: Results of German clinical research projects conducted are largely underreported. Barriers to successful publication need to be identified and appropriate measures taken. Close monitoring of projects until publication and adequate support provided to investigators may help remedy the prevailing underreporting of research.
Resumo:
This thesis represents the overview of hydrographic surveying and different types of modern and traditional surveying equipment, and data acquisition using the traditional single beam sonar system and a modern fully autonomous underwater vehicle, IVER3. During the thesis, the data sets were collected using the vehicles of the Great Lake Research Center at Michigan Technological University. This thesis also presents how to process and edit the bathymetric data on SonarWiz5. Moreover, the three dimensional models were created after importing the data sets in the same coordinate system. In these interpolated surfaces, the details and excavations can be easily seen on the surface models. In this study, the profiles are plotted on the surface models to compare the sensors and details on the seabed. It is shown that single beam sonar might miss some details, such as pipeline and quick elevation changes on the seabed when we compare to the side scan sonar of IVER3 because the single side scan sonar can acquire better resolution. However, sometimes using single beam sonar can save your project time and money because the single beam sonar is cheaper than side scan sonars and the processing might be easier than the side scan data.
Resumo:
When masculine forms are used to refer to men and women, this causes male-biased cognitive representations and behavioral consequences, as numerous studies have shown. This effect can be avoided or reduced with the help of gender-fair language. In this talk, we will present different approaches that aim at influencing people’s use of and attitudes towards gender-fair language. Firstly, we tested the influence of gender-fair input on people’s own use of gender-fair language. Based on Irmen and Linner’s (2005) adaptation of the scenario mapping and focus approach (Sanford & Garrod, 1998), we found that after reading a text with gender-fair forms women produced more gender-fair forms than women who read gender-neutral texts or texts containing masculine generics. Men were not affected. Secondly, we examined reactions to arguments which followed the Elaboration Likelihood Model (Petty &Cacioppo, 1986). We assumed that strong pros and cons would be more effective than weak arguments or control statements. The results indicated that strong pros could convince some, but not all participants, suggesting a complex interplay of diverse factors in reaction to attempts at persuasion. The influence of people’s initial characteristics will be discussed. Currently, we are investigating how self-generated refutations, in addition to arguments, may influence initial attitudes. Based on the resistance appraisal hypothesis (Tormala, 2008), we assume that individuals are encouraged in their initial attitude if they manage to refute strong counter-arguments. The results of our studies will be discussed regarding their practical implications.
Resumo:
INTRODUCTION The new ATS/ERS consensus report recommends in vitro validation of multiple-breath inert gas washout (MBW) equipment based on a lung model with simulated physiologic conditions. We aimed to assess accuracy of two MBW setups for infants and young children using this model, and to compare functional residual capacity (FRC) from helium MBW (FRCMBW ) with FRC from plethysmography (FRCpleth ) in vivo. METHODS The MBW setups were based on ultrasonic flow meter technology. Sulfur hexafluoride and helium were used as tracer gases. We measured FRC in vitro for specific model settings with and without carbon dioxide and calculated differences of measured to generated FRC. For in vivo evaluation, difference between FRCMBW and FRCpleth was calculated in 20 healthy children, median age 6.1 years. Coefficient of variation (CV) was calculated per FRC. RESULTS In the infant model (51 runs, FRC 80-300 ml), mean (SD) relative difference between generated and measured FRCs was 0.7 (4.7) %, median CV was 4.4% for measured FRCs. In the young child model, one setting (8 runs, FRC 400 ml) showed a relative difference of up to 13%. For the remaining FRCs (42 runs, FRC 600-1,400 ml), mean (SD) relative difference was -2.0 (3.4) %; median CV was 1.4% for measured FRCs. In vivo FRCpleth exceeded FRCMBW values by 37% on average. CONCLUSIONS Both setups measure lung volumes in the intended age group reliably and reproducibly. Characteristics of different techniques should be considered when measuring lung volumes in vivo. Pediatr Pulmonol. © 2014 Wiley Periodicals, Inc.
Resumo:
BACKGROUND A rapid review, guided by a protocol, was conducted to inform development of the World Health Organization's guideline on personal protective equipment in the context of the ongoing (2013-present) Western African filovirus disease outbreak, with a focus on health care workers directly caring for patients with Ebola or Marburg virus diseases. METHODS Electronic databases and grey literature sources were searched. Eligibility criteria initially included comparative studies on Ebola and Marburg virus diseases reported in English or French, but criteria were expanded to studies on other viral hemorrhagic fevers and non-comparative designs due to the paucity of studies. After title and abstract screening (two people to exclude), full-text reports of potentially relevant articles were assessed in duplicate. Fifty-seven percent of extraction information was verified. The Grading of Recommendations Assessment, Development and Evaluation framework was used to inform the quality of evidence assessments. RESULTS Thirty non-comparative studies (8 related to Ebola virus disease) were located, and 27 provided data on viral transmission. Reporting of personal protective equipment components and infection prevention and control protocols was generally poor. CONCLUSIONS Insufficient evidence exists to draw conclusions regarding the comparative effectiveness of various types of personal protective equipment. Additional research is urgently needed to determine optimal PPE for health care workers caring for patients with filovirus.
Resumo:
AMS-14C applications often require the analysis of small samples. Such is the case of atmospheric aerosols where frequently only a small amount of sample is available. The ion beam physics group at the ETH, Zurich, has designed an Automated Graphitization Equipment (AGE III) for routine graphite production for AMS analysis from organic samples of approximately 1 mg. In this study, we explore the potential use of the AGE III for graphitization of particulate carbon collected in quartz filters. In order to test the methodology, samples of reference materials and blanks with different sizes were prepared in the AGE III and the graphite was analyzed in a MICADAS AMS (ETH) system. The graphite samples prepared in the AGE III showed recovery yields higher than 80% and reproducible 14C values for masses ranging from 50 to 300 lg. Also, reproducible radiocarbon values were obtained for aerosol filters of small sizes that had been graphitized in the AGE III. As a study case, the tested methodology was applied to PM10 samples collected in two urban cities in Mexico in order to compare the source apportionment of biomass and fossil fuel combustion. The obtained 14C data showed that carbonaceous aerosols from Mexico City have much lower biogenic signature than the smaller city of Cuernavaca.
Resumo:
The aim of this work is to develop a software that allows the inspection of spur gear manufactured in the sub-millimeter range. The measurements are made using a digital optical machine and using an analysis proprietary software implemented in Matlab®, which is able to handle images, captured using the digital optical machine. The software allows to evaluate the profile and pitch deviations as establish in the ISO/TR 10064-1:1992 standard