876 resultados para Enginyeria de gas
Resumo:
Since GHB (gamma-hydroxybutyric acid) is naturally produced in the human body, clinical and forensic toxicologists must be able to discriminate between endogenous levels and a concentration resulting from exposure. To suggest an alternative to the use of interpretative concentration cut-offs, the detection of exogenous GHB in urine specimens was investigated by means of gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). GHB was isolated from urinary matrix by successive purification on Oasis MCX and Bond Elute SAX solid-phase extraction (SPE) cartridges prior to high-performance liquid chromatography (HPLC) fractioning using an Atlantis dC18 column eluted with a mixture of formic acid and methanol. Subsequent intramolecular esterification of GHB leading to the formation of gamma-butyrolactone (GBL) was carried out to avoid introduction of additional carbon atoms for carbon isotopic ratio analysis. A precision of 0.3 per thousand was determined using this IRMS method for samples at GHB concentrations of 10 mg/L. The (13)C/(12)C ratios of GHB in samples of subjects exposed to the drug ranged from -32.1 to -42.1 per thousand, whereas the results obtained for samples containing GHB of endogenous origin at concentration levels less than 10 mg/L were in the range -23.5 to -27.0 per thousand. Therefore, these preliminary results show that a possible discrimination between endogenous and exogenous GHB can be made using carbon isotopic ratio analyses.
Resumo:
En el cas sota estudi, hem revisat totes les memòries oficials de verificació disponibles dels graus en enginyeria en informàtica, enginyeria en telecomunicació i multimèdia amb l'objectiu d'analitzar diferents aspectes de la presència de diferents competències comunicatives transversals. En concret ens hem centrat en les competències d'expressió oral i escrita en llengua pròpia i estrangera (anglès), en l'habilitat en les relacions interpersonals i en la capacitat de comunicar-se amb audiències expertes i profanes sobre els matèries dels estudis.
Resumo:
L'aplicació desenvolupada és un entorn web que permetrà als estudiants de la UOC millorarel seu rendiment en les assignatures d'Enginyeria del programari, mitjançant la utilització de l'eina de correcció automàtica de diagrames UML desenvolupada pel grup de recerca GRES-UOC.
Resumo:
L'objectiu d'aquest Treball Final de Carrera consisteix en la realització del desenvolupament d'un Gestor d'Administració de Sistemes (GAS). El desenvolupament d'aquest gestor tindrà ús real i vindrà a cobrir una necessitat del departament de Sistemas Informàtic de l'Hospital Americà de la Base Naval de Trencada on treball com a administradora de sistemes.
Resumo:
L'objectiu d'aquest projecte és fer ús de la nova programació orientada a aspectes (AOP) per a fer tasques de reenginyeria. la finalitat seria que, amb l'ajut d'aquesta tecnologia, es pogués extreure informació de l'execució d'una aplicació, de manera que a partir d'aquesta informació es pogués obtenir el diagrama de cas d'ús.
Resumo:
Actualment a l'Estat espanyol s'està implantant el Pla Bolonya per incorporar-se a l'Espai Europeu d'Estudis Superiors (l'EEES). Com a un dels principals objectius, l'EEES pretén homogeneïtzar els estudis i de manera concreta les competències adquirides per qualsevol estudiant independentment d'on hagi realitzat els seus estudis. Per això, existeixen iniciatives europees (com el projecte Tuning) que treballen per definir competències per a totes les titulacions universitàries.El projecte presenta l'anàlisi realitzat sobre vint Universitats de diferents continents per identificar models d'ensenyament-aprenentatge de competències no tècniques. La recerca es centra addicionalment en la competència comunicativa escrita.La font principal de dades ha estat la informació proporcionada a les pàgines Web de les universitats i molt especialment els seus plans d'estudi.
Resumo:
Per una banda, contextualitza el concepte de competència professional dins del marc de l'EEES, i reconeix i classifica a partir de la revisió de la documentació existent les competències específiques i transversals o genèriques, que han de tenir els nous titulats del Grau d'EI. Per altra banda, s'escomet l'anàlisi dels plans d'estudi i dels plans docents del Grau per identificar la seva adaptació al EEES,, concretament en el que fa referència a la competència de comunicació escrita.
Sensitive headspace gas chromatography analysis of free and conjugated 1-methoxy-2-propanol in urine
Resumo:
Glycol ethers still continue to be a workplace hazard due to their important use on an industrial scale. Currently, chronic occupational exposures to low levels of xenobiotics become increasingly relevant. Thus, sensitive analytical methods for detecting biomarkers of exposure are of interest in the field of occupational exposure assessment. 1-Methoxy-2-propanol (1M2P) is one of the dominant glycol ethers and the unmetabolized urinary fraction has been identified to be a good biological indicator of exposure. An existing analytical method including a solid-phase extraction and derivatization before GC/FID analysis is available but presents some disadvantages. We present here an alternative method for the determination of urinary 1M2P based on the headspace gas chromatography technique. We determined the 1M2P values by the direct headspace method for 47 samples that had previously been assayed by the solid-phase extraction and derivatization gas chromatography procedure. An inter-method comparison based on a Bland-Altman analysis showed that both techniques can be used interchangeably. The alternative method showed a tenfold lower limit of detection (0.1 mg/L) as well as good accuracy and precision which were determined by several urinary 1M2P analyses carried out on a series of urine samples obtained from a human volunteer study. The within- and between-run precisions were generally about 10%, which corresponds to the usual injection variability. We observed that the differences between the results obtained with both methods are not clinically relevant in comparison to the current biological exposure index of urinary 1M2P. Accordingly, the headspace gas chromatography technique turned out to be a more sensitive, accurate, and simple method for the determination of urinary 1M2P.[Authors]
Resumo:
A gas chromatographic-mass spectrometric method is presented which allows the determination of chlorzoxazone and 6-hydroxychlorzoxazone after derivatization with the reagent N-tert.-butyldimethylsilyl-N-methyltrifluoroacetamide. No interference was observed from endogenous compounds following the extraction of plasma samples from six different human subjects. The standard curves were linear over a working range of 20 to 4000 ng/ml and of 20 to 1000 ng/ml for chlorzoxazone and 6-hydroxychlorzoxazone, respectively. Recoveries ranged from 65 to 97% for the two compounds and intra- and inter-day coefficients of variation were always less than 9%. The limit of quantitation of the method was found to be 5 ng/ml for the two compounds, hence allowing its use for single low dose pharmacokinetics.
Resumo:
The aim of our study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable for the routine determination of blood CO concentration in forensic toxicology laboratories. The main drawback of the GC/MS methods discussed in literature for CO measurement is the absence of a specific CO internal standard necessary for performing quantification. Even if stable isotope of CO is commercially available in the gaseous state, it is essential to develop a safer method to limit the manipulation of gaseous CO and to precisely control the injected amount of CO for spiking and calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in a vial in situ, an internal labeled standard gas ((13)CO) formed by the reaction of labeled formic acid formic acid (H(13)COOH) with sulfuric acid. As sulfuric acid can also be employed to liberate the CO reagent from whole blood, the procedure allows for the liberation of CO simultaneously with the generation of (13)CO. This method allows for precise measurement of blood CO concentrations from a small amount of blood (10 μL). Finally, this method was applied to measure the CO concentration of intoxicated human blood samples from autopsies.
Resumo:
Repàs de la trajectòria professional com a editor, començant com a editor de caire socialista i acabant col·laborant amb la dictadura de Primo de Rivera. Es fa especial menció al seu paper com a editor de Josep Pla i a la seva editorial, Ediciones Alfa
Resumo:
Introduction: Ethylglucuronide (EtG) is a direct and specific metabolite of ethanol. Its determination in hair is of increasing interest for detecting and monitoring alcohol abuse. The quantification of EtG in hair requires analytical methods showing highest sensitivity and specificity. We present a fully validated method based on gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS/MS). The method was validated using French Society of Pharmaceutical Sciences and Techniques (SFSTP) guidelines which are based on the determination of the total measurement error and accuracy profiles. Methods: Washed and powdered hair is extracted in water using an ultrasonic incubation. After purification by Oasis MAX solid phase extraction, the derivatized EtG is detected and quantified by GC-NCI-MS/MS method in the selected reaction monitoring mode. The transitions m/z 347 / 163 and m/z 347 / 119 were used for the quantification and identification of EtG. Four quality controls (QC) prepared with hair samples taken post mortem from 2 subjects with a known history of alcoholism were used. A proficiency test with 7 participating laboratories was first run to validate the EtG concentration of each QC sample. Considering the results of this test, these samples were then used as internal controls for validation of the method. Results: The mean EtG concentrations measured in the 4 QC were 259.4, 130.4, 40.8, and 8.4 pg/mg hair. Method validation has shown linearity between 8.4 and 259.4 pg/mg hair (r2 > 0.999). The lower limit of quantification was set up at 8.4 pg/mg. Repeatability and intermediate precision were found less than 13.2% for all concentrations tested. Conclusion: The method proved to be suitable for routine analysis of EtG in hair. GC-NCI-MS/MS method was then successfully applied to the analysis of EtG in hair samples collected from different alcohol consumers.