921 resultados para Elastic-modulus


Relevância:

60.00% 60.00%

Publicador:

Resumo:

160 p. (Bibliogr. 141-160)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present paper aims to develop a robust spherical indentation-based method to extract material plastic properties. For this purpose, a new consideration of-piling-up effect is incorporated into the expanding cavity model; an extensive numerical study on the similarity Solution has also been performed. As a consequence, two semi-theoretical relations between the indentation response and material plastic properties are derived, with which plastic properties of materials can be identified from a single instrumented spherical indentation curve, the advantage being that this approach no longer needs estimations of contact radius with given elastic modulus. Moreover, the inconvenience in using multiple indenters with different tip angles can be avoided. Comprehensive sensitivity analyses show that the present algorithm is reliable. Also, by experimental verification performed oil three typical materials, good agreement of the material properties between those obtained from the reverse algorithm and experimental data is obtained.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The osteocyte network is recognized as the major mechanical sensor in the bone remodeling process, and osteocyte-osteoblast communication acts as an important mediator in the coordination of bone formation and turnover. In this study, we developed a novel 3D trabecular bone explant co-culture model that allows live osteocytes situated in their native extracellular matrix environment to be interconnected with seeded osteoblasts on the bone surface. Using a low-level medium perfusion system, the viability of in situ osteocytes in bone explants was maintained for up to 4 weeks, and functional gap junction intercellular communication (GJIC) was successfully established between osteocytes and seeded primary osteoblasts. Using this novel co-culture model, the effects of dynamic deformational loading, GJIC, and prostaglandin E-2 (PGE(2)) release on functional bone adaptation were further investigated. The results showed that dynamical deformational loading can significantly increase the PGE(2) release by bone cells, bone formation, and the apparent elastic modulus of bone explants. However, the inhibition of gap junctions or the PGE(2) pathway dramatically attenuated the effects of mechanical loading. This 3D trabecular bone explant co-culture model has great potential to fill in the critical gap in knowledge regarding the role of osteocytes as a mechano-sensor and how osteocytes transmit signals to regulate osteoblasts function and skeletal integrity as reflected in its mechanical properties.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A contração de polimerização das resinas compostas é uma característica indesejável que compromete a integridade da interface dente/restauração. O objetivo deste estudo foi avaliar in vitro a influência de diferentes materiais usados em restaurações classe II de resina composta, quanto ao grau de conversão, tensão de contração, resistência a flexão, módulo de elasticidade e formação de fenda marginal. Foram realizados preparos classe II com dimensões de 4x4x2mm em terceiros molares recém-extraídos para a avaliação da formação de fenda marginal. As cavidades foram niveladas com cimento de ionômero de vidro Riva Light Cure (SDI) (CIV), resina de baixa contração SureFilSDR (Dentsply) (SDR), resina flow FiltekZ350Flow (3M/ESPE) (Z350F) e resina composta FiltekP90 (3M/ESPE) (P90). As restaurações (n=3) foram avaliadas com lupa estereoscópica. A resistência a flexão foi avaliada por meio de ensaio de flexão em três pontos. Para este ensaio foram confeccionados dez corpos de prova (n=10) de cada material com dimensões de 10x2x1mm. Para o teste de tensão de contração foram utilizados cilindros de polimetacrilato com 5 mm de diâmetro e 13 ou 28mm de comprimento. Os bastões foram fixados na EMIC com um espaço de 2mm entre eles, onde os materiais foram inseridos. Foram realizadas cinco repetições para cada grupo (n=5) e a tensão proveniente da contração foi medida por até 10 minutos após o início da fotopolimerização. O Grau de Conversão (GC) foi determinado por espectroscopia no infravermelho com transformada de Fourier (FTIR). Os resultados foram tratados estatisticamente por análise de variância (ANOVA) e Teste de Tukey (p<0,05). Fenda marginal: Z350F = CIV > SDR = P90. Tensão de contração: Z350F > SDR > CIV = P90. Resistência a flexão: P90 > SDR = Z350F > CIV. Módulo de Elasticidade: P90 > CIV = SDR = Z350F. GC: Z350F = SDR > P90 > CIV. Conclusões: existe correlação entre a formação de fenda marginal e as propriedades físico químicas dos materiais testados, sendo as resinas de baixa contração que proporcionaram melhor adaptação marginal; existe correlação entre resistência a flexão, módulo de elasticidade, tensão de contração e a composição dos materiais, já que os compósitos com melhores resultados foram os que apresentaram os maiores percentuais de carga, no entanto, maior grau de conversão não representou melhores propriedades mecânicas.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O presente trabalho foi desenvolvido com o intuito de estudar a utilização do método de ensaio não destrutivo de ultrassom para inspecionar e caracterizar materiais compósitos. Os objetivos principais da pesquisa foram medir a espessura, encontrar e dimensionar delaminações em reparo de material compósito laminado para tubulações e medir a velocidade do som no concreto para o cálculo do módulo de elasticidade. Inicialmente foram estudados os parâmetros físicos relevantes inerentes a cada material para o método de ultrassom, para então estabelecer uma metodologia de inspeção. A técnica de pulso-eco foi capaz de encontrar as descontinuidades no compósito laminado. Para a determinação do módulo de elasticidade do concreto, a técnica de transmissão foi utilizada obtendo-se resultados satisfatórios.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

No presente trabalho, foram processados compósitos de polietileno de alta densidade (PEAD) com hidroxiapatita deficiente de cálcio (HA), com o objetivo de obter materiais com melhores propriedades mecânicas e bioatividade. A adição da HA deficiente de cálcio proporcionou um aumento no módulo de elasticidade (maior rigidez), menor resistência ao impacto e decréscimo do grau de cristalinidade do PEAD, proporcionando uma maior bioatividade ao material. A análise térmica exploratória (sistema não isotérmico) foi realizada por meio da técnica de calorimetria exploratória diferencial (DSC) e foram avaliados os teores de fosfato de cálcio e a velocidade de rotação da rosca no processamento dos materiais. No estudo da cristalização não-isotérmica observou-se uma diminuição da temperatura de cristalização com o aumento da taxa de resfriamento para todos os materiais sintetizados. A energia de ativação (Ea) da cristalização dos materiais foi avaliada por meio dos métodos Kissinger e Ozawa. A amostra com 5% de HA deficiente de cálcio e velocidade de processamento de 200 rpm foi a que apresentou menor valor de energia de ativação, 262 kJ/mol, menor desvio da linearidade e a que mais se assemelhou à matriz de PEAD sem HA. O teor de hidroxiapatita deficiente de cálcio não favorece o processo de cristalização devido à alta energia de ativação determinada pelos métodos descritos. Provavelmente, a velocidade de rotação, favorece a dispersão da carga na matriz de PEAD, dificultando o processo de cristalização. Na aplicação do método de Osawa-Avrami, os coeficientes de correlação indicaram perda na correlação linear. Estas perdas podem estar associadas a uma pequena percentagem de cristalização secundária e/ou à escolha das temperaturas utilizadas para determinar a velocidade de cristalização. Na determinação dos parâmetros pelo método de Mo, as menores percentagens de cristalização apresentaram um grande desvio da linearidade, com coeficiente de correlação bem menor que 1 e com o aumento da percentagem de cristalização, o desvio da linearidade diminui, ficando próximo de 1. Os resultados obtidos mostraram que o modelo de Mo e de Osawa-Avrami não foram capazes de definir o comportamento cinético dos materiais produzidos neste trabalho.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O objetivo desse estudo, in vitro, foi avaliar através de testes mecânicos e tribológicos, a aplicação de dois glazeadores disponíveis comercialmente e uma composição experimental como material de cobertura em restaurações de resina composta com relação à rugosidade superficial, à dureza e à resistência ao desgaste. Foram confeccionados 24 corpos de prova (CP) do compósito Z350XT (3M/ESPE) e divididos em 4 grupos. O grupo controle (GC) não recebeu selamento, o grupo Biscover LV (GB) recebeu aplicação do Biscover LV (Bisco), o grupo Natural Glaze (GN) recebeu aplicação do Natural Glaze (Nova DFL) e o grupo Experimental (GE) recebeu aplicação de um glazeador experimental contendo nanopartículas (1% em peso). Posteriormente, os CP foram submetidos à análise da rugosidade superficial utilizando um perfilômetro e avaliação da dureza através de um nanoindentador, que fornece também o módulo elástico do material. Em seguida, os CP foram submetidos ao teste de desgaste linear alternado, durante 15.000 ciclos, com carga de 5N, em água destilada. A profundidade máxima de desgaste foi avaliada através de um perfilômetro. A análise dos dados relativos à rugosidade superficial (m) foi realizada utilizando ANOVA/Duncan (p-valor = 0,000). As médias e desvio padrão foram: GC-0,12(0,01); GB-0,06(0,01); GN-0,13(0,02); GE-0,13(0,01). A análise da dureza (GPa) e módulo elástico (GPa) foram avaliados aplicando o teste não-paramétrico de Kruskal-Wallis. As médias e desvio padrão para dureza foram: GC-1,10(0,24); GB-0,31(0,004); GN-0,08(0,004); GE-0,12(0,008) para carga de 1,25mN; GC-1,08(0,139); GB-0,32(0,004); GN-0,08(0,003); GE-0,13(0,006) para carga de 2,5mN; GC-1,10(0,101); GB-0,33(0,003); GN-0,09(0,002); GE-0,13(0,056) para carga de 5,0mN. As médias e desvio padrão para módulo elástico foram: GC-17,71(1,666); GB-5,44(0,084); GN-3,484(0,114); GE-4,55(0,178) para carga de 1,25mN; GC-17,5(1,449); GB-5,18(0,065); GN-3,38(0,078); GE-4,55(0,12) para carga de 2,5mN; GC-17,69(1,793); GB-5,04(0,041); GN-3,63(0,066); GE-4,85(0,104) para carga de 5,0mN. A análise dos dados relativos à profundidade de desgaste (m) foi realizada utilizando ANOVA/Dunnett (p-valor = 0,000). As médias e desvio padrão foram: GC-12,51(0,89); GB-0,59(0,07); GN-1,41(0,12); GE-1,84(0,18). A partir dos resultados apresentados pode-se concluir que apenas o Biscover LV foi capaz de reduzir a rugosidade superficial da resina composta testada. Os demais, Natural Glaze e Experimental, não alteraram a rugosidade superficial e foram estatisticamente semelhantes entre si e com o grupo controle. Todos os glazeadores testados reduziram a dureza e o módulo elástico da resina composta quando comparados com o grupo controle, diferindo entre si, apresentando uma ordem crescente de dureza e módulo elástico (Natural Glaze < Experimental < Biscover < Controle). Todos os glazeadores testados foram capazes de reduzir o desgaste da resina composta, quando comparados com o grupo controle, diferindo entre si, apresentado uma ordem crescente de desgaste (Biscover < Natural Glaze < Experimental < Controle).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A model has been developed to predict the erosive wear behaviour of elastomers under conditions of glancing impact by small hard particles. Previous work has shown the erosive wear mechanism of elastomers under these conditions to be similar in nature to that of abrasive wear by a sharp blade. The model presented here was developed from the model of Southern and Thomas for sliding abrasion, by combining their treatment of the growth of surface cracks with a model for particle impact in which the force - displacement relationship for an idealized flat-ended punch on a semi-infinite elastic solid was assumed. In this way an expression for the erosive wear rate was developed, and compared with experimental measurements of wear rate for natural rubber, styrene - butadiene rubber and a highly crosslinked polybutadiene rubber. Good qualitative agreement was found between the predictions of the model and the experimental measurements. The variation of erosion rate with impact velocity, impact angle, particle size, elastic modulus of the material, coefficient of friction and fatigue properties were all well accounted for. Quantitative agreement was less good, and the effects of erosive particle shape could not be accounted for. The reasons for these discrepancies are discussed. © 1992 IOP Publishing Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In order to improve drilling mud design to cater for specific well situations, a more comprehensive knowledge and understanding of filter cake failure is needed. This paper describes experimental techniques aimed at directly probing the mechanical properties of filter cakes, without having to take into account artefacts due to fluid flow in the substrate. The use of rheometers allows us to determine shear yield stress and dynamic shear modulii of cakes grown on filter paper. A new scraping technique measures the strength and moisture profiles of typical filter cakes with a 0.1 mm resolution. This technique also allows us to probe the adhesion between the filter cake and its rock substrate. In addition, œdometer drained consolidation and unloading of a filter cake give us compression parameters useful for Cam Clay modelling. These independent measurements give similar results as to the elastic modulus of different filter cakes, showing an order of magnitude difference between water based and oil based cakes. We find that these standard cakes behave predominantly as purely elastic materials, with a sharp transition into plastic flow, allowing for the determination of a well-defined yield stress. The effect ofsolids loading on a given type of mud is also studied.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nanoindentation is a popular technique for measuring the intrinsic mechanical response of bone and has been used to measure a single-valued elastic modulus. However, bone is a composite material with 20-80 nm hydroxyapatite plates embedded in a collagen matrix, and modern instrumentation allows for measurements at these small length scales. The present study examines the indentation response of bone and artificial gelatin-apatite nanocomposite materials across three orders of magnitude of lengthscale, from nanometers to micrometers, to isolate the composite phase contributions to the overall response. The load-displacement responses were variable and deviated from the quadratic response of homogeneous materials at small depths. The distribution of apparent elastic modulus values narrowed substantially with increasing indentation load. Indentation of particulate nanocomposites was simulated using finite element analysis. Modeling results replicated the convergence in effective modulus seen in the experiments. It appears that the apatite particles are acting as the continuous ("matrix") phase in bone and nanocomposites. Copyright © 2004 by ASME.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The contribution of the relative volumes of mineral and collagen to the nanomechanical behavior of articular calcified cartilage is explored using nanoindentation, quantitative backscattered electron imaging, and finite element analysis. Elastic modulus generally increases with mineral volume fraction. In highly mineralized tissues, the mineral occupation of water space significantly increases modulus with addition of little mineral. Mineral and organic phases were modeled using Hashin-Shtrikman composite bounds, calculated as a function of mineral volume fraction. Modulus values fall between the Hashin-Shtrikman bounds, indicating some intermediate degree of mineral phase connectivity. Such connectivity in ACC is greater than that achieved in bone and results from uniform collagen orientation and large volume of water space available for mineral occupation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A key issue in the fabrication of Terfenol-D 2-2 composites with internal magnetic field biasing is the selection of appropriate constituent materials to obtain high magnetostriction while keeping optimum magnetomechanical properties. The fabrication process is costly and time consuming and, therefore, numerical methods to predict their properties are useful. In this paper, finite element analysis (FEA) of the magnetostriction of such composites has been carried out using the commercial package ABAQUS. It has been shown that composites fabricated using Nd2Fe14B for the permanent magnetic material layers possess the highest internal fields within the Terfenol-D layers, although the overall strain of these composites is limited to approximately 800 × 10-6 due to the high elastic modulus of Nd2Fe14B. Simulations showed that the strain can be enhanced by choosing a different material with a lower elastic modulus for the permanent magnetic layer even though the internal field is lower. The simulations showed that the strain can increase by 12% if the Nd 2Fe14B layer is substituted by SmCo5; by 23% if it is substituted by Sm2Co17; and by 35% if it is substituted by Alnico. © 2008 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Noise and vibration from underground railways is a major source of disturbance to inhabitants near subways. To help designers meet noise and vibration limits, numerical models are used to understand vibration propagation from these underground railways. However, the models commonly assume the ground is homogeneous and neglect to include local variability in the soil properties. Such simplifying assumptions add a level of uncertainty to the predictions which is not well understood. The goal of the current paper is to quantify the effect of soil inhomogeneity on surface vibration. The thin-layer method (TLM) is suggested as an efficient and accurate means of simulating vibration from underground railways in arbitrarily layered half-spaces. Stochastic variability of the soils elastic modulus is introduced using a KL expansion; the modulus is assumed to have a log-normal distribution and a modified exponential covariance kernel. The effect of horizontal soil variability is investigated by comparing the stochastic results for soils varied only in the vertical direction to soils with 2D variability. Results suggest that local soil inhomogeneity can significantly affect surface velocity predictions; 90 percent confidence intervals showing 8 dB averages and peak values up to 12 dB are computed. This is a significant source of uncertainty and should be considered when using predictions from models assuming homogeneous soil properties. Furthermore, the effect of horizontal variability of the elastic modulus on the confidence interval appears to be negligible. This suggests that only vertical variation needs to be taken into account when modelling ground vibration from underground railways. © 2012 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Bone is a complex material with a hierarchical multi-scale organization from the molecule to the organ scale. The genetic bone disease, osteogenesis imperfecta, is primarily caused by mutations in the collagen type I genes, resulting in bone fragility. Because the basis of the disease is molecular with ramifications at the whole bone level, it provides a platform for investigating the relationship between structure, composition, and mechanics throughout the hierarchy. Prior studies have individually shown that OI leads to: 1. increased bone mineralization, 2. decreased elastic modulus, and 3. smaller apatite crystal size. However, these have not been studied together and the mechanism for how mineral structure influences tissue mechanics has not been identified. This lack of understanding inhibits the development of more accurate models and therapies. To address this research gap, we used a mouse model of the disease (oim) to measure these outcomes together in order to propose an underlying mechanism for the changes in properties. Our main finding was that despite increased mineralization, oim bones have lower stiffness that may result from the poorly organized mineral matrix with significantly smaller, highly packed and disoriented apatite crystals. Using a composite framework, we interpret the lower oim bone matrix elasticity observed as the result of a change in the aspect ratio of apatite crystals and a disruption of the crystal connectivity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To investigate how substrate properties influence stem-cell fate, we cultured single human epidermal stem cells on polydimethylsiloxane (PDMS) and polyacrylamide (PAAm) hydrogel surfaces, 0.1 kPa-2.3 MPa in stiffness, with a covalently attached collagen coating. Cell spreading and differentiation were unaffected by polydimethylsiloxane stiffness. However, cells on polyacrylamide of low elastic modulus (0.5 kPa) could not form stable focal adhesions and differentiated as a result of decreased activation of the extracellular-signal-related kinase (ERK)/mitogen-activated protein kinase (MAPK) signalling pathway. The differentiation of human mesenchymal stem cells was also unaffected by PDMS stiffness but regulated by the elastic modulus of PAAm. Dextran penetration measurements indicated that polyacrylamide substrates of low elastic modulus were more porous than stiff substrates, suggesting that the collagen anchoring points would be further apart. We then changed collagen crosslink concentration and used hydrogel-nanoparticle substrates to vary anchoring distance at constant substrate stiffness. Lower collagen anchoring density resulted in increased differentiation. We conclude that stem cells exert a mechanical force on collagen fibres and gauge the feedback to make cell-fate decisions.