998 resultados para ELECTROCHEMICAL FORMATION


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ionic liquids (ILs) based on trihexyltetradecylphosphonium coupled with either diphenylphosphate or bis(trifluoromethanesulfonyl)amide have been shown to react with magnesium alloy surfaces, leading to the formation a surface film that can improve the corrosion resistance of the alloy. The morphology and microstructure of the magnesium surface seems critical in determining the nature of the interphase, with grain boundary phases and intermetallics within the grain, rich in zirconium and zinc, showing almost no interaction with the IL and thereby resulting in a heterogeneous surface film. This has been explained, on the basis of solid-state NMR evidence, as being due to the extremely low reactivity of the native oxide films on the intermetallics (ZrO2 and ZnO) with the IL as compared with the magnesium-rich matrix where a magnesium hydroxide and/or carbonate inorganic surface is likely. Solid-state NMR characterization of the ZE41 alloy surface treated with the IL based on (Tf)2N− indicates that this anion reacts to form a metal fluoride rich surface in addition to an organic component. The diphenylphosphate anion also seems to undergo an additional chemical process on the metal surface, indicating that film formation on the metal is not a simple chemical interaction between the components of the IL and the substrate but may involve electrochemical processes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The generation of potentially corrosion-resistant films on light metal alloys of magnesium have been investigated. Magnesium alloy, ZE41 [Mg−Zn−Rare Earth (RE)-Zr, nominal composition 4 wt % Zn, 1.7 wt % RE (Ce), 0.6 wt % Zr, remaining balance, Mg], was exposed under potentiostatic control to the ionic liquid trihexyl(tetradecyl)phosphonium diphenylphosphate, denoted [P6,6,6,14][DPP]. During exposure to this IL, a bias potential, shifted from open circuit, was applied to the ZE41 surface. Electrochemical impedance spectroscopy (EIS) and chronoamperometry (CA) were used to monitor the evolution of film formation on the metal surface during exposure. The EIS data indicate that, of the four bias potentials examined, applying a potential of −200 mV versus OCP during the exposure period resulted in surface films of greatest resistance. Both EIS measurements and scanning electron microscopy (SEM) imaging indicate that these surfaces are substantially different to those formed without potential bias. Time of flight-secondary ion mass spectrometry (ToF-SIMS) elemental mapping of the films was utilized to ascertain the distribution of the ionic liquid cationic and anionic species relative to the microstructural surface features of ZE41 and indicated a more uniform distribution compared with the surface following exposure in the absence of a bias potential. Immersion of the treated ZE41 specimens in a chloride contaminated salt solution clearly indicated that the ionic liquid generated surface films offered significant protection against pitting corrosion, although the intermetallics were still insufficiently protected by the IL and hence favored intergranular corrosion processes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An electrochemical approach to the formation of a protective surface film on Mg alloys immersed in the ionic liquid (IL), trihexyl(tetradecyl)phosphonium–bis 2,4,4-trimethylpentylphosphinate, was investigated in this work. Initially, cyclic voltammetry was used with the Mg alloy being cycled from OCP to more anodic potentials. EIS data indicate that, under these circumstances, an optimum level of protection was achieved at intermediate potentials (e.g., 0 or 0.25 V versus Ag/AgCl). In the second part of this paper, a small constant bias was applied to the Mg alloy immersed in the IL for extended periods using a novel cell design. This electrochemical cell allowed us to monitor in situ surface film formation on the metal surface as well as the subsequent corrosion behaviour of the metal in a corrosive medium. This apparatus was used to investigate the evolution of the surface film on an AZ31 magnesium alloy under a potential bias (between ±100 mV versus open circuit) applied for over 24 h, and the film evolution was monitored using electrochemical impedance spectroscopy (EIS). A film resistance was determined from the EIS data and it was shown that this increased substantially during the first few hours (independent of the bias potential used) with a subsequent decrease upon longer exposure of the surface to the IL. Preliminary characterization of the film formed on the Mg alloy surface using ToF-SIMS indicates that a multilayer surface exists with a phosphorous rich outer layer and a native oxide/hydroxide film underlying this. The corrosion performance of a treated AZ31 specimen when exposed to 0.1 M NaCl aqueous solution showed considerable improvement, consistent with electrochemical data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The modification of electrodes with the tripeptide Gly–Gly–His for the detection of copper in water samples is described in detail. The tripeptide modified electrode was prepared by first self-assembling 3-mercaptopropionic acid (MPA) onto the gold electrode followed by covalent attachment of the tripeptide to the self-assembled monolayer using carbodiimide coupling. The electrodes were characterized using electrochemistry, a newly developed mass-spectrometry method and quantum mechanical calculations. The mass spectrometry confirmed the modification to proceed as expected with peptide bonds formed between the carboxylic acids of the MPA and the terminal amine of the peptide. Electrochemical measurements indicated that approximately half the MPA molecules in a SAM are modified with the peptide. The peptide modified electrodes exhibited high sensitivity to copper which is attributed to the stable 4N coordinate complex the peptide formed around the metal ion to give copper the preferred tetragonal coordination. The formation of a 4 coordinate complex was predicted using quantum mechanical calculation and confirmed using mass spectrometry. The adsorption of the copper to the peptide modified electrode was consistent with a Langmuir isotherm with a binding constant of (8.1 ± 0.4) 1010 M−1 at 25 °C.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The new ligand, [Fc(cyclen)2] (5) (Fc=ferrocene, cyclen=1,4,7,10-tetraazacyclododecane), and corresponding ZnII complex receptor, [Fc{Zn(cyclen)(CH3OH)}2](ClO4)4 (1), consisting of a ferrocene moiety bearing one ZnII-cyclen complex on each cyclopentadienyl ring, have been designed and prepared through a multi-step synthesis. Significant shifts in the 1H NMR signals of the ferrocenyl group, cf. ferrocene and a previously reported [Fc{Zn(cyclen)}]2+ derivative, indicated that the two ZnII-cyclen units in 1 significantly affect the electronic properties of the cyclopentadienyl rings. The X-ray crystal structure shows that the two positively charged ZnII-cyclen complexes are arranged in a trans like configuration, with respect to the ferrocene bridging unit, presumably to minimise electrostatic repulsion. Both 5 and 1 can be oxidized in 1:4 CH2Cl2/CH3CN and Tris-HCl aqueous buffer solution under conditions of cyclic voltammetry to give a well defined ferrocene-centred (Fc0/+) process. Importantly, 1 is a highly selective electrochemical sensor of thymidilyl(3′-5′)thymidine (TpT) relative to other nucleobases and nucleotides in Tris-HCl buffer solution (pH 7.4). The electrochemical selectivity, detected as a shift in reversible potential of the Fc0/+ component, is postulated to result from a change in the configuration of bis(ZnII-cyclen) units from a trans to a cis state. This is caused by the strong 1:1 binding of the two deprotonated thymine groups in TpT to different ZnII centres of receptor 1. UV-visible spectrophotometric titrations confirmed the 1:1 stoichiometry for the 1:TpT adduct and allowed the determination of the apparent formation constant of 0.89±0.10×106 M−1 at pH 7.4.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electrochemical impedance spectroscopy (EIS) was used to study and evaluate commercial batch treatment inhibitors which are used for protecting oil wells, gas wells, and pipelines from CO2 corrosion, focusing on the evaluation of inhibitor film persistency. It was found that theformation and deterioration of batch treatment inhibitor films were accompanied by typical impedance spectral changes. During the formation of inhibitor films, electrode impedance showed a rapid increase and the Bode phase angle plots also showed a sudden change. Thus, the formation of inhibitor film was a very fast process. During the deterioration of inhibitor films, electrode impedance showed a gradual decrease and the Bode phase angle plots showed changes which characterised the three stages of the inhibitor film deterioration process. The relationships between EIS and corrosion rate are discussed, including comparisons with weight loss measurements. Based on the experimental findings in the present work, a method is suggested for estimating the persistency of inhibitor films by monitoring the characteristic changes in the Bode phase angle plots and by measuring electrochemical charge transfer resistance at the second and third stages of the inhibitor film deterioration process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electrochemical noise analysis (ENA) was used to monitor continuously the formation and deterioration processes of a commercial batch treatment inhibitor film of the type used for protecting against CO2 corrosion in oilfields; ENA was shown to be able to follow effectively the formation and deterioration processes of batch treatment inhibitor films. As an inhibitor film formed, the current noise amplitude decreased rapidly and the noise resistance Rn, which is deducible from the voltage and current noise records, was found to increase sharply. Conversely, as the inhibitor film deteriorated, the current noise amplitude increased rapidly and Rn decreased rapidly. In the corrosion inhibition system studied, the noise resistance was confirmed to be similar to the linear polarisation resistance. Based on the calculation of Rn on a continuous basis, a technique is proposed to study fast corrosion processes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electrochemical impedance spectroscopy (EIS) was used to study carbon dioxide (CO2) corrosion product scales and their effects on further CO2 corrosion. Objectives were to determine the suitability of EIS for studying corrosion scales and to investigate the influence of environmental factors on scale formation. EIS provided useful information about protective abilities and electrochemical properties of corrosion scales. CO2 corrosion scales formed at high-temperature and pressure provided better protection than those formed at low-temperature and pressure. The level of protection of the scale formed at higher temperature and pressure increased with exposure time. EIS results were compared with coupon weight-loss measurements. Scales were analyzed using a combination of Fourier transform infrared (FTIR) analysis, x-ray diffraction (XRD), and electron microscopy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Three types of methylcyclohexane (MCH) coating were deposited as interlayer dielectrics on copper using plasma-enhanced chemical vapor deposition (PECVD) at three different RF plasma power levels. The coating performance was then evaluated by an electrochemical im pedance spectroscopy (EIS) and a potentiodynamic polarization test in 3.5 wt.% NaCl solution. An atomic force microscopy (AFM) and Fourier transform infrared reflection (FT-IR) spectroscopy were also conducted to analyze the coatings. The MCH coatings showed a lower corrosion rate than the copper substrate in the potentiodynamic tests. The EIS results showed that the corrosion resistance of the coatings increased with an increasing plasma power. Thus, the MCH films with an increasing plasma power improved the corrosion resistance due to the formation of a low-porosity coating, the enhanced formation of C−H, C−C, and C≡C stretching configurations, and the improved smooth surfaces.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CrN films on a bipolar plate in polymer electrolyte membrane fuel cells have several advantages owing to their excellent corrosion resistance and mechanical properties. Three CrN samples deposited at various radio frequency (RF) powers by RF magnetron sputtering were evaluated under potentiodynamic, potentiostatic and electrochemical impedance spectroscopy conditions. The electrochemical impedance spectroscopy data were monitored for 168 h in a corrosive environment at 70 °C to determine the coating performance at +600 mVSCE under simulated cathodic conditions in a polymer electrolyte membrane fuel cell. The electrochemical behavior of the coatings increased with decreasing RF power. CrN films on the AISI 316 stainless steel substrate showed high protective efficiency and charge transfer resistance, i.e. increasing corrosion resistance with decreasing RF power. X-ray diffraction confirmed the formation of a CrN(200) preferred orientation at low RF power.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electrochemical impedance spectroscopy (EIS) was used to study carbon dioxide (CO2) corrosion product scales and their effects on further CO2 corrosion. Objectives were to determine the suitability of EIS for studying corrosion scales and to investigate the influence of environmental factors on scale formation. EIS provided useful information about protective abilities and electrochemical properties of corrosion scales. CO2 corrosion scales formed at high-temperature and pressure provided better protection than those formed at low-temperature and pressure. The level of protection of the scale formed at higher temperature and pressure increased with exposure time. EIS results were compared with coupon weight-loss measurements. Scales were analyzed using a combination of Fourier transform infrared (FTIR) analysis, x-ray diffraction (XRD), and electron microscopy

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Three new ortho -metallated palladium complexes, [Pd(O,O’-hfacac)(κ2-2-C6F4PPh2)] (11), [Pd2(O,O’hfacac)2(μ-2-C6F4PPh2)2](12) and [Pd(O,O’-hfacac)(κC-2-C6F4PPh2)(PPh3)] (13) (hfacac = hexafluoroace-tylacetonate), have been prepared and fully characterised. The electrochemical reductions of complexes 11–13, together with those of other cyclopalladated complexes containing 2C6R4PPh2 ligands (R = H, F) were studied by cyclic, rotating disk and microelectrode voltammetry. Evidence for the one-electron reduction of [PdI(κ2-2-C6F4PPh2)(PPh2Fc)] (6) was obtained from coulometric analysis, although the product is unstable and undergoes further chemical processes. Preparative electro-reduction of [Pd2(μ-Br)2(κ2-2-C6F4PPh2)2] (7) in CH2Cl2 causes reductive cleavage of its Pd–C σ-bonds and formation of the complex [PdBr2{PPh2(2-C6F4H)}2](14); possible mechanisms are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

All rights reserved. A graphene nanodots-encaged porous gold electrode via ion beam sputtering deposition (IBSD) for electrochemical sensing is presented. The electrodes were fabricated using Au target, and a composite target of Al and graphene, which were simultaneously sputtered onto glass substrates by Ar ion beam, followed with hydrochloric acid corrosion. The as-prepared graphene nanodots-encaged porous gold electrodes were then used for the analysis of heavy metal ions, e.g. Cu2+ and Pb2+ by Osteryoung square wave voltammetry (OSWV). These porous electrodes exhibited enhanced detection range for the heavy metal ions due to the entrapped graphene nanodots in 3-D porous structure. In addition, it was also found that when the thickness of porous electrode reached 40 nm the detection sensitivity came into saturation. The linear detection range is 0.009-4 μM for Cu2+ and 0.006-2.5 μM for Pb2+. Good reusability and repeatability were also observed. The formation mechanism and 3-D structure of the porous electrode were also investigated using scanning electron microscope (SEM), transmission electron microscope (TEM) and X-ray photoelectron spectra (XPS). This graphene entrapped 3-D porous structure may envision promising applications in sensing devices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Whilst ionic liquids (IL) have been shown to inhibit corrosion on some reactive metals and alloys by forming a surface film, e.g. Li and Mg, understanding of the interaction between ionic liquids and aluminium is lacking. This research study investigated the viability of film formation on AA5083 Aluminium Alloy by electrochemical treatments in the trihexyl(tetradecyl)phosphonium diphenylphosphate ([P6,6,6,14][dpp]) IL. Two-step anodic treatments were performed on AA5083 in the IL, followed by a comparison of the corrosion behaviour of the IL-treated samples with that of a control. It has been revealed that the two-step IL-treatment led to reduced current densities on AA5083 under cyclic voltammetry scan in the IL before and after the IL-treatment. Lower corrosion rates have been shown on all samples treated in IL at room temperature. Surface characterisation showed a non-uniform porous film on the 50°C IL-treated sample with a film thickness ranging between 37nm and 155nm. The IL-film enhanced the corrosion resistance of AA5083 by protecting the Al-matrix and Fe-rich intermetallic particles (IMPs). Although findings of this study suggest similar IL-film formation as that on Li and Mg, more research needs to be conducted to optimise the electrochemical treatment conditions and ultimately to develop a robust IL-film formation procedure for corrosion protection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two quinoline derivatives, 8-aminoquinoline (8-AQ) and 8-nitroquinoline (8-NQ), have been used as inhibitors to examine their corrosion protection effect on AA5052 aluminium alloy in 3% NaCl solution. The weight-loss and electrochemical measurement have indicated that 8-AQ and 8-NQ play as anodic inhibitor to retard the anodic electrochemical process. SEM/EDS analysis clearly shows that 8-AQ and 8-NQ form a protective film on the AA5052 alloy surface. Density functional theory (DFT) calculation confirmed the formation of strong hybridization between the p-orbital of reactive sites in the inhibitor molecules and the sp-orbital of the Al atom. 8-aminoquinoline and 8-nitroquinoline may be useful as effective corrosion inhibitors for aluminium alloys.