924 resultados para ECCENTRIC CONTRACTIONS
Resumo:
Mode of access: Internet.
Resumo:
Includes index.
Resumo:
On t-p verso: Stereotyped at the Boston Stereotype Foundry... -- "Lubricatory" (i.e., preface): p.5-6; "Contents": p.7-10
Resumo:
Mode of access: Internet.
Resumo:
Aim. The purpose of this experiment was to assess the levels of muscle soreness, serum total cholesterol (TC) and creatine kinase (CK) in the first 48 hours following fatiguing eccentric exercise performed with the triceps brachii. Methods. Eleven untrained male college students performed a total of 50 eccentric elbow extensions in 8 sets (6x7 and 2x4) with a load equal to 85% of their maximal concentric elbow extension strength. Isometric elbow extension strength, muscle soreness and circumference, and serum CK and TC concentrations were measured before, immediately after, and 2, 24 and 48 hours after the exercise. Results. Statistically reliable changes in isometric strength, serum CK and TC, muscle soreness and upper arm circumference occurred within the first 48 hours following eccentric exercise. Serum TC concentrations exhibited a very rapid (within 2 hours) reduction from pre-exercise values after eccentric exercise to a relatively stable concentration of approximately 85% of baseline. Conclusion. These results suggest that serum TC concentration may follow the time-course of reductions in force generating capacity more closely than other biochemical markers of muscle damage.
Resumo:
We compared changes in markers of muscle damage and systemic inflammation after submaximal and maximal lengthening muscle contractions of the elbow flexors. Using a cross-over design, 10 healthy young men not involved in resistance training completed a submaximal trial (10 sets of 60 lengthening contractions at 10% maximum isometric strength, 1 min rest between sets), followed by a maximal trial (10 sets of three lengthening contractions at 100% maximum isometric strength, 3 min rest between sets). Lengthening contractions were performed on an isokinetic dynamometer. Opposite arms were used for the submaximal and maximal trials, and the trials were separated by a minimum of two weeks. Blood was sampled before, immediately after, 1 h, 3 h, and 1-4 d after each trial. Total leukocyte and neutrophil numbers, and the serum concentration of soluble tumor necrosis factor-alpha receptor 1 were elevated after both trials (P < 0.01), but there were no differences between the trials. Serum IL-6 concentration was elevated 3 h after the submaximal contractions (P < 0.01). The concentrations of serum tumor necrosis factor-alpha, IL-1 receptor antagonist, IL-10, granulocyte-colony stimulating factor and plasma C-reactive protein remained unchanged following both trials. Maximum isometric strength and range of motion decreased significantly (P < 0.001) after both trials, and were lower from 1-4 days after the maximal contractions compared to the submaximal contractions. Plasma myoglobin concentration and creatine kinase activity, muscle soreness and upper arm circumference all increased after both trials (P < 0.01), but were not significantly different between the trials. Therefore, there were no differences in markers of systemic inflammation, despite evidence of greater muscle damage following maximal versus submaximal lengthening contractions of the elbow flexors.
Resumo:
We report on an optical bend sensor based on a Bragg grating inscribed in an eccentric core polymer optical fiber. The device exhibits the strong fiber orientation dependence, the wide bend curvature range of ± 22.7 m-1 and high bend sensitivity of 63 pm/m-1.
Resumo:
This study investigated the detrimental effect of central field loss (CFL) on reading ability and general visual function. The aim was to improve the understanding of reading with eccentric retina in order that reading performances of individuals with CFL may be maximised. To improve visual ability of individuals with CFL, it is important to be able to accurately measure the outcome of any intervention. Various methods for determining visual function were therefore compared with perceived visual performance (as measured with a quality of life questionnaire) before and after surgical removal of choroidal new vessels (CNV) in macular disease patients. The results highlight the importance of low contrast measures (low contrast visual acuity and contrast sensitivity) when investigating perceived reading performance. Reading speed was found to be important for reflecting changes in general visual quality of life. Potential causes for reduced peripheral reading ability were investigated using both normally sighted and CFL subjects. For normally sighted subjects reading eccentrically with rapid serial visual presentation (RSVP) text, the inferior visual field was a better position (in terms of reading speed) for the presentation of the text. The size of the visual span was found to reduce with increasing eccentricity of fixation, providing a potential reason for reduced peripheral reading performances. The investigation of the ability to use context when reading with peripheral retina resulted in conflicting results. Studies in this thesis found both a reduction and no reduction in the ability of the peripheral retina to utilise context compared to the fovea. Individuals with long-term CFL showed no improvement in peripheral reading ability over that found for normally sighted subjects reading at the same eccentricity.