891 resultados para Dual frequency microstrip Antenna


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Wearable antenna performance measurements were used to characterize a synthetic variable layered phantom testbed, representative of human tissue for operation in the 868/915 MHz, and 2400 MHz industrial, scientific and medical frequency bands. Antenna radiation efficiency measurements on the phantom were compared with measurements on the thorax region of a human test subject. The results show that the phantom is representative of the human body for the application of wireless vital sign monitors, where conductive connections are made to the tissue.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A wearable silver nano particle inkjet printed antenna suitable for wireless biomedical sensing is presented. The performance is evaluated on a synthetic variable layered phantom test-bed, representative of human tissue for operation in the 868/915 MHz, and 2400 MHz industrial, scientific and medical frequency bands. Antenna radiation efficiency measurements on the phantom were compared with antennas prototyped with copper. Total radiation efficiencies up to ???6.5 dB are reported, with less than 0.5 dB difference in performance between copper and silver nano particle variants, showing promising application for low-cost disposable wireless sensing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work investigates low cost localization systems (LS) based on received signal strength (RSS) and integrated with different types of antennas with main emphasis on sectorial antennas. The last few years have witnessed an outstanding growth in wireless sensor networks (WSN). Among its various possible applications, the localization field became a major area of research. The localization techniques based on RSS are characterized by simplicity and low cost of integration. The integration of LS based on RSS and sectorial antennas (SA) was proven to provide an effective solution for reducing the number of required nodes of the networks and allows the combination of several techniques, such as RSS and angle of arrival (AoA). This PhD thesis focuses on studying techniques, antennas and protocols that best meet the needs of each LS with main focus on low cost systems based on RSS and AoA. Firstly there are studied localization techniques and system that best suit the requirements of the user and the antennas that are most appropriate according to the nature of the signal. In this step it is intended to provide a fundamental understanding of the undertaken work. Then the developed antennas are presented according to the following categories: sectorial and microstrip antennas. Two sectorial antennas are presented: a narrowband antenna operating at 2.4 to 2.5 GHz and a broadband antenna operating at 800MHz-2.4GHz. The low cost printed antennas were designed to operate at 5 GHz, which may be used for vehicular communication. After presenting the various antennas, several prototypes of indoor/outdoor LS are implemented and analyzed. Localization protocols are also proposed, one based on simplicity and low power, and the other on interoperability with different types of antennas and system requirements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Due to the application of active components into antennas these became a source of distortion on wireless communication systems. In this paper we explore the nonlinear effects occurring in a frequency reconfigurable antenna operating with a PIN Diode. We describe the measurement setup used to check the antenna intermodulation products and the measured compression and third order intermodulation limitations of a frequency reconfigurable antenna, operating at the UMTS and WLAN frequencies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Titre: La Visualisation in vivo des « espèces oxygénées radiculaires» au niveau des cellules ganglionnaires de la rétine. Le But : Les espèces d'oxygène réactives sont non seulement produites à la suite de la blessure cellulaire, mais servent aussi des molécules faisantes des signes pour une variété de processus critiques, en incluant mitosis et de mort de cellule. Nous avons auparavant dit que la blessure à RGC axons incite un éclatement de superoxyde dans le corps de cellule, probablement de l'origine mitochondrial (Lieven et al, 2006). Nous décrivons maintenant une méthode pour refléter des espèces d'oxygène réactives dans la rétine de l'animal vivant en utilisant un confocal le lisant rapidement du laser ophthalmoscope a appelé la Rétine de Heidelberg Angiograph 2 (HRA2) équipé avec les lasers doubles. La méthodolologie : Après les études préliminaires en utilisant d'autres indicateurs (hydroethidium; HEt) pour les espèces d'oxygène réactives, nous avons essayé de refléter des espèces d'oxygène réactives dans le dans le modèle de vivo l'utilisation 5-(et 6)-chloromethyl-2', 7 '-dichlorodihydrofluorescein diacetate, l'acétyle ester (le CM-H2DCFDA). Un nerf optique de Longs-Evans rats a été écrasé intraorbitalement, en épargnant la circulation retinal. Dans certains rats colliculi supérieur de Longs rats Evans avait été auparavant exposé via craniotomy et surposé avec Gelfoam saturé avec le vert indocyanine (ICG). Aux points de temps variables les animaux ont été injectés intraveineusement ou intravitreally avec HEt ou le CM-H2DCFDA et reflétés avec fluorescein et-ou les filtres d'ICG en utilisant le HRA2. Les résultats: Nous avons démontré le foyer brillant multiple de fluorescence dans la couche de cellule de ganglion quand nous avons rétrogradement étiqueté d'ICG bilatéralement, en indiquant qu'ICG était un colorant rétrogradement transporté qui pourrait être découvert avec le HRA2. Après axotomy et l'injection intravitreal de CM-H2DCFDA, il y avait la fluorescence brillante dans le canal fluorescein dans quelques cellules dans la couche de cellule de ganglion, en accord avec la production d'une ou plusieurs espèces d'oxygène réactives. Les conclusions : RGCs peut être identifié et les niveaux d'espèces d'oxygène réactives mesurés en utilisant une fréquence double confocal Mots-clés : cellules ganglionnaires de la rétine; especes oxygenique radiculaire; la visualisation;

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Photonic band-gap (PBG) structures are utilized in microwave components as filters to suppress unwanted signals. In this work, rectangular perforations were created in the ground plane of a microstrip line to construct a PBG structure. A gold-coated alumina substrate was utilized to switch or tune the bandstop characteristics of this structure. It was demonstrated that the bandstop characteristics were switched off from - 35 to - 1 dB at 16 GHz. Tuning of the bandstop edge with a shift of 1.5 GHz was also shown

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The closed form expression for the radiated power of a half-wave microstrip patch is modified to calculate the impedance bandwidth of a printed dipole. Analyses of cavity backed flared and end-loaded printed dipoles are presented

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents a theoretical, numerical and computation analysis of parameters of a rectangular microstrip antenna with metamaterial substrate, fin line as a coupler and also integrated devices like integrated filter antenna. It is applied theory to full-wave of Transverse Transmission Line - TTL method, to characterize the magnitude of the substrate and obtain the general equations of the electromagnetic fields. About the metamaterial, they are characterized by permittivity and permeability tensor, reaching to the general equations for the electromagnetic fields of the antenna. It is presented a study about main representation of PBG(Photonic Band Gap) material and its applied for a specific configuration. A few parameters are simulated some structures in order to reduce the physical dimensions and increase the bandwidth. The results are presented through graphs. The theoretical and computational analysis of this work have shown accurate and relatively concise. Conclusions are drawn and suggestions for future work

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Metamaterials have attracted a great attention in recent years mostly due to their electromagnetic properties not found in nature. Since metamaterials began to be synthesized by the insertion of artificially manufactured inclusions in a medium specified host , it provides the researcher a broad collection of independent parameters such as the electromagnetic properties of the material host. In this work was presents an investigation of the unique properties of Split Ring Resonators and compounds metamaterials was performed. We presents a theoretical and numerical analysis , using the full-wave formalism by applying the Transverse Transmission Line - LTT method for the radiation characteristics of a rectangular microstrip antenna using metamaterial substrate, as is successfully demonstrated the practical use of these structures in antennas. We experimentally confirmed that composite metamaterial can improved the performance of the structures considered in this thesis

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work is the analysis of a structure of the microstrip antenna designed for application in ultra wide band systems (Ultra Wideband - UWB). This is a prospective analytical study where they tested the changes in the geometry of the antenna, observing their suitability to the proposed objectives. It is known that the UWB antenna must operate in a range of at least 500 MHz, and answer a fractional bandwidth greater than or equal to 25%. It is also desirable that the antenna meets the specifications of track determined by FCC - Federal Communication Commission, which regulates the system in 2002 designating the UWB bandwidth of 7.5 GHz, a range that varies from 3.1 GHz to 10, 6 GHz. by setting the maximum power spectral density of operation in -41.3 dB / MHz, and defining the fractional bandwidth by 20%. The study starts of a structure of geometry in the form of stylized @, which evolves through changes in its form, in simulated commercial software CST MICROWAVE STUDIO, version 5.3.1, and then tested using the ANSOFT HFSS, version 9. These variations, based on observations of publications available from literature referring to the microstrip monopole planar antennas. As a result it is proposed an antenna, called Monopole Antenna Planar Spiral Almost Rectangular for applications in UWB systems - AMQEUWB, which presents simulated and measured results satisfactory, consistent with the objectives of the study. Some proposals for future work are mentioned

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the absence of the selective availability, which was turned off on May 1, 2000, the ionosphere can be the largest source of error in GPS positioning and navigation. Its effects on GPS observable cause a code delays and phase advances. The magnitude of this error is affected by the local time of the day, season, solar cycle, geographical location of the receiver and Earth's magnetic field. As it is well known, the ionosphere is the main drawback for high accuracy positioning, when using single frequency receivers, either for point positioning or relative positioning of medium and long baselines. The ionosphere effects were investigated in the determination of point positioning and relative positioning using single frequency data. A model represented by a Fourier series type was implemented and the parameters were estimated from data collected at the active stations of RBMC (Brazilian Network for Continuous Monitoring of GPS satellites). The data input were the pseudorange observables filtered by the carrier phase. Quality control was implemented in order to analyse the adjustment and to validate the significance of the estimated parameters. Experiments were carried out in the equatorial region, using data collected from dual frequency receivers. In order to validate the model, the estimated values were compared with ground truth. For point and relative positioning of baselines of approximately 100 km, the values of the discrepancies indicated an error reduction better than 80% and 50% respectively, compared to the processing without the ionospheric model. These results give an indication that more research has to be done in order to provide support to the L1 GPS users in the Equatorial region.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

GPS precise point positioning (PPP) can provide high precision 3-D coordinates. Combined pseudorange and carrier phase observables, precise ephemeris and satellite clock corrections, together with data from dual frequency receivers, are the key factors for providing such levels of precision (few centimeters). In general, results obtained from PPP are referenced to an arbitrary reference frame, realized from a previous free network adjustment, in which satellite state vectors, station coordinates and other biases are estimated together. In order to obtain consistent results, the coordinates have to be transformed to the relevant reference frame and the appropriate daily transformation parameters must be available. Furthermore, the coordinates have to be mapped to a chosen reference epoch. If a velocity field is not available, an appropriated model, such as NNR-NUVEL-IA, has to be used. The quality of the results provided by this approach was evaluated using data from the Brazilian Network for Continuous Monitoring of the Global Positioning System (RBMC), which was processed using GIPSY-OASIS 11 software. The results obtained were compared to SIRGAS 1995.4 and ITRF2000, and reached precision better than 2cm. A description of the fundamentals of the PPP approach and its application in the integration of regional GPS networks with ITRF is the main purpose of this paper.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

When GNSS receivers capable of collecting dual-frequency data are available, it is possible to eliminate the first-order ionospheric effect in the data processing through the ionosphere-free linear combination. However, the second- and third-order ionospheric effects still remain. The first-, second- and third-order ionospheric effects are directly proportional to the total electron content (TEC), although the second- and third-order effects are influenced, respectively, by the geomagnetic field and the maximum electron density. In recent years, the international scientific community has given more attention to these kinds of effects and some works have shown that for high precision GNSS positioning these effects have to be taken into consideration. We present a software tool called RINEX_HO that was developed to correct GPS observables for second- and third-order ionosphere effects. RINEX_HO requires as input a RINEX observation file, then computes the second- and third-order ionospheric effects, and applies the corrections to the original GPS observables, creating a corrected RINEX file. The mathematical models implemented to compute these effects are presented, as well as the transformations involving the earth's magnetic field. The use of TEC from global ionospheric maps and TEC calculated from raw pseudorange measurements or pseudoranges smoothed by phase is also investigated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cada vez mais é crescente o uso do GPS (Global Positioning System ) em estudos da atmosfera terrestre. Neste artigo, a atmosfera superior da Terra, denominada ionosfera, foi estudada durante um período de alta atividade solar (ano de 2001) usando dados de receptores GPS de dupla freqüência localizados na região brasileira, pertencentes à RBMC (Rede Brasileira de Monitoramento Contínuo). A partir dos dados GPS foram calculados os valores de TEC (Total Electron Content - Conteúdo Total de Elétrons) da ionosfera. Adicionalmente foram incluídos no estudo dados de freqüência crítica da camada F2 advinda de Digissondas localizadas em São Luís/MA (3ºS; 44ºW) e Cachoeira Paulista/SP (22ºS; 45ºW), para fins de comparação. de uma forma geral, os resultados mostraram maiores valores de TEC durante os meses próximos aos equinócios e menores durante os meses de inverno. Quanto à variação diária do TEC, os menores valores foram verificados por volta das 4-6 HL (Hora Local) e os maiores durante o período da tarde, com valores um pouco maiores para São Luís. O segundo pico da anomalia equatorial foi verificado em Cachoeira Paulista nos meses próximos aos equinócios e verão. Na maioria dos meses, uma alta correlação linear foi verificada quando realizada a comparação entre os valores de freqüência crítica da camada F2 e os de TEC, principalmente para São Luís.