985 resultados para Doppler


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Left ventricular diastolic dysfunction plays an important role on heart failure progression. In order to obtain additional reference values of left ventricular diastolic parameters and investigate influence of common variables, peak E wave (peak E), peak A wave (peak A), E/A ratio (E/A), E wave deceleration time (EDT) and isovolumic relaxation time (IRVT) were studied in 40 clinically healthy dogs, by pulsed wave Doppler. The following values were obtained: peak E = 0.747 ± 0.117 m/s, peak A = 0.487 ± 0.062 m/s, E/A = 1.533 ± 0.198, EDT = 88.7 ± 9.2 ms and IRVT = 0.080 ± 0.009 s. Some parameters were influenced by heart rate (peak E, peak A and IRVT), by age (peak A and E/A) and by body weight (TRIV). Gender influence was absent. Values obtained can be used as reference for canine specimens but its interpretation should consider on the influence of related variables.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo do trabalho foi estabelecer a relação entre a ecobiometria renal com medidas de conformação corporal como a distância atlanto-coccígea (DAC) e a altura (H) de cães adultos saudáveis, obtendo-se parâmetros de normalidade para avaliar o tamanho e volume renal, bem como estabelecer valores de referência para avaliar a perfusão sanguínea dos rins por meio do índice de resistividade (IR) e do índice de pulsatilidade (IP) do ramo principal da artéria renal. No estudo foram utilizados 22 cães adultos sem raça definida, sendo 11 machos e 11 fêmeas. Os animais foram previamente aferidos quanto a DAC e a H. Os exames ultra-sonográficos foram realizados com um aparelho HDI 4000 PHILIPS munido de um transdutor microconvexo multifreqüêncial (5-8 MHz), dispositivos Doppler Colorido e Doppler de Fluxo. Os animais foram posicionados em decúbito lateral direito ou esquerdo, de acordo com o rim a ser avaliado. Os diâmetros longitudinal (DL) e dorsoventral (DDV) dos rins foram mensurados na secção longitudinal e, o diâmetro transversal (DT) foi aferido no plano transversal. O volume (V) foi calculado automaticamente pelo software do ultra-som. Com o uso do Triplex Doppler, o IR e o IP das artérias renais direita e esquerda foram obtidos. Todos os dados foram apresentados em média ± EPM. Análises de regressão linear foram realizadas tendo o DL, DDV, DT e V como variáveis dependentes e a DAC e H como variáveis independentes. Os IR e IP dos rins direito e esquerdo foram comparados pelo teste t de Student. A DAC variou de 54-78cm para machos e 37-71cm para fêmeas e a altura variou entre 34-64 cm para os machos e 24-57cm para as fêmeas. As médias obtidas para DL, DDV, DT e V dos rins esquerdo e direito foram: 5,24±0,27cm, 3,07±0,15cm, 3,07±0,9cm, 28,01±3,4mL e 4,50±0,19cm, 2,88±0,14cm, 2,71±0,15cm, 21,27±2,6mL, respectivamente. As análises de regressão linear entre as medidas lineares e volume renal com a DAC e a H foram significativas para os interceptos e coeficientes de regressão (P<0,01). Houve diferenças estatísticas quando comparado os IR e IP entre os rins direito e esquerdo (P=0,001), sendo que as médias para IR e IP dos rins esquerdo e direito foram 0,62±0,08; 1,34±0,18 e 0,70±0,06; 1,62±0,13; respectivamente. Os dados obtidos no presente trabalho podem auxiliar na avaliação do tamanho, volume e perfusão dos rins de cães adultos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Avaliaram-se com Doppler pulsátil os fluxos das valvas aórtica (AO) e pulmonar (Pul) por meio de análise qualitativa (presença de regurgitações valvares e características do espectro avaliado) e quantitativa, com obtenção de parâmetros ecocardiográficos como velocidades máxima (V. Max.) e média (V. Me.), integral de velocidade (VTI), tempo de aceleração (TA) e ejeção (TE), de 30 cães considerados clinicamente sadios por meio de exames físico, laboratoriais, eletrocardiográfico, ecocardiográfico (modos uni e bidimensional), radiográfico de tórax e mensuração da pressão arterial sistêmica. Obtiveram-se os seguintes resultados para os referidos parâmetros: V.max. AO= 1,22± 19,38m/s; V. Me. AO= 0,72± 0,08m/s; VTI AO= 0,14± 0,02m; TA AO= 38,80± 11,29ms; TE AO= 197,90± 24,77ms; V. Max. Pul= 0,95± 0,18m/s; V. Me. Pul= 0,63± 0,10m/s; VTI Pul= 0,13± 0,02m; TA Pul= 70,97± 18,87ms; TE Pul= 203,70± 28,98ms. Em apenas três animais observou-se regurgitação pulmonar. Alguns parâmetros apresentaram correlação negativa com a variável freqüência cardíaca (VTI AO, TE AO, VTI Pul, TA Pul, TE Pul); outros correlação positiva com a variável peso (VTI AO, TA AO, TE AO, VTI Pul, TE Pul,) e não se observou influência da variável sexo na maioria dos parâmetros avaliados. Na comparação entre os dois fluxos, observaram-se V. Max. AO e V. Me. AO maiores que V. Max. Pul. e V. Me. Pul., respectivamente, VTI AO maior que VTI Pul, e TA AO menor que TA Pul.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo do presente estudo foi avaliar a hemodinâmica renal de cadelas com piometra por meio de exames laboratoriais, ultrassonografia Modo B e Doppler, antes e após o tratamento cirúrgico com ovariosanpigohisterectomia (OSH). Foram utilizadas 30 cadelas com diagnóstico de piometra, todas foram submetidas a OSH (momento 1) e 20 foram reavaliadas sete dias após a cirurgia (momento 2). A perfusão renal, o índice de resistividade da artéria renal principal e de cada artéria interlobar (cranial, média e caudal) foi estatisticamente diferente entre os momentos 1 e 2 (p<0,05). Não foi observada diferença estatística para a perfusão renal entre o rim direito e esquerdo no momento 1 e 2. As correlações entre o índice de resistividade da artéria renal principal e as variáveis utilizadas para verificar a função renal foram estabelecidas no momento 1. Para as variáveis correlacionadas ureia, creatinina, proteinúria, relação GGT/creatinina e proteína/creatinina ocorreram associações curvilíneas e positivas com o índice de resistividade da artéria renal principal (p<0,05), no entanto essas correlações foram consideradas de média e fracas. Ao comparar o IR da artéria renal principal com diferentes escores de desidratação e perfusão renal, este foi estatisticamente diferente, e demonstrou aumento da resistência renal em cadelas com moderada redução da perfusão renal, assim como em cadelas desidratadas. Foram avaliadas diversas características de morfologia renal na ultrassonografia Modo B, no entanto, somente as variáveis presença de dilatação de pelve, sinal da medular e outras alterações como áreas de infartos e pontos hiperecogênicos difusos na cortical e medular renal foram estatisticamente distintas de um momento para o outro, com maior frequência no momento 2. Os resultados do presente trabalho demonstram que a ultrassonografia Doppler pode identificar alterações de redução na perfusão renal, por meio do Doppler colorido e o aumento do índice de resistividade das artérias renais em cadelas com piometra. Assim como, a ultrassonografia modo B, embora apresente alterações inespecíficas, pode detectar alterações renais progressivas em cadelas com piometra.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper aims to describe the uterine and ovarian ultrasonographic characteristics and Doppler velocimetric features of their arteries in bitches during the periovulatory period. Fifteen estrous cycles in 10 animals were evaluated. The ultrasonographic characteristics, resistance indices (RI) and pulsatility indices (PI) of the uterus and ovaries in each animal were recorded 5 days before and after ovulation (D0). The data were statistically analyzed, and the results were expressed as the mean ± standard error of mean (P<0.05). In results the ultrasonographic features of the uterus were the same on all of the cycles and evaluated days. The uterus had an average diameter of 0.85±0.02cm. An increase in the volume of the ovaries and the diameter of the ovarian follicles were measured. Ovaries had a volume of 0.64±0.06cm³, and the follicles cavities had a diameter of 0.46 ± 0.01 cm on the day of ovulation. After ovulation, it was observed that some follicles not collapse in some cycles. Two days prior to ovulation, the uterine blood perfusion decreased. This decrease remained unchanged until ovulation. Following ovulation, we measured a gradual increase in the uterine perfusion and in the ovarian artery. This artery directed blood flow to the ovaries and increased the intra-ovarian perfusion on the day after ovulation. In conclusion, specific features are observed in the uterus and ovarian ultrasound image and Doppler values of their arteries presented on the periovulatory days and when associated allow to estimate more accurately the date of ovulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A cardiomiopatia hipertrófica (CMH) é a principal cardiopatia dos felinos e é caracterizada por hipertrofia miocárdica concêntrica, sem dilatação ventricular. Disfunções miocárdicas ocorrem em gatos com CMH, mas pouco se conhece a respeito destas alterações nos estágios iniciais da afecção. Em gatos da raça Maine Coon, a mutação no gene MyBPC-A31P está relacionada com a CMH de origem familial, porém, a correlação exata entre o genótipo e o fenótipo ainda é inconclusiva. A ecocardiografia tecidual é uma modalidade não invasiva que permite avaliação da função miocárdica e é mais sensível que a ecocardiografia convencional. Para avaliar as funções sistólica e diastólica, antes ou após a ocorrência de hipertrofia ventricular, gatos da raça Maine Coon (n=57), geneticamente testados para a mutação, foram avaliados por meio de ecocardiografias convencional e tecidual (nas modalidades Doppler tecidual pulsado e Doppler tecidual colorido). Posteriormente, foram fenotipicamente classificados em: normais (n=45), suspeitos (n=7) e acometidos pela CMH (n=5); e genotipicamente classificados em: negativos (n=28), heterozigotos (n=26) e homozigotos para a mutação (n=3). Valores de velocidades miocárdicas (Doppler tecidual pulsado e colorido) medidos na região basal e média do septo interventricular (SIV), da parede livre do ventrículo esquerdo (PVE), da parede anterior do ventrículo esquerdo (PAVE), da parede posterior do ventrículo esquerdo (PPVE) e do segmento radial da PVE, foram comparados nos diferentes grupos. Observou-se que as velocidades longitudinais Em (Doppler tecidual pulsado) na região média da PVE foram menores nos gatos com CMH quando comparados com suspeitos e normais. Os valores de Em/Am (Doppler tecidual colorido), na região basal do SIV, foram inferiores nos gatos com CMH quando comparados com suspeitos e normais. A relação E/Em (Doppler tecidual colorido), na região basal do SIV, foi maior nos gatos com CMH em relação aos suspeitos e normais, enquanto que os valores de Sm (Doppler tecidual colorido), em região basal da PVE, foram menores nos gatos heterozigotos quando comparados com os negativos, ambos sem hipertrofia ventricular. Observou-se correlação positiva entre a ocorrência de fusão das ondas Em e Am e a frequência cardíaca, assim como correlação positiva entre valores de Sm e Em e a frequência cardíaca (Doppler tecidual pulsado e colorido). A ecocardiografia tecidual é uma nova modalidade ecocardiográfica reprodutível em gatos que, isoladamente, não permite diferenciar gatos portadores da mutação antes do desenvolvimento de hipertrofia ventricular. Apresenta utilidade como auxílio no diagnóstico em fases iniciais, mas, apesar da expectativa para a identificação precoce de indivíduos portadores da CMH, ainda há necessidade de estudos mais extensos e com maior número de indivíduos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to assess whether there are differences in Doppler velocimetry parameters between different sizes. Twenty dogs were equally divided into small and large groups used in this study. The dogs were evaluated using Triplex ultrasound. Testicular artery was located by Colour Doppler in the spermatic cord, marginal to the testes and intratesticular segments and then, spectral Doppler were used to calculate: peak systolic velocity (PSV), end diastolic velocity (EDV), resistance index (RI) and pulsatility index (PI). The mean testicular volume in the left side was significantly higher than the right side, in both groups. Doppler examination showed higher velocities (EDV) at spermatic cord in large dogs; marginal to the testes was observed higher velocities in small dogs; intratesticular region no differences were observed (P < 0.05) and within the groups differences between segments of the artery were also observed for each parameter. The results showed that there are differences in Doppler velocimetry parameters between different sizes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract: Annually hundreds of crab-eating foxes (Cerdocyon thous) are referred to rehabilitation centers and zoos in Brazil. The ultrasonographic study of wildlife species is an important tool for a non-invasive and accurate anatomical description and provides important information for wildlife veterinary care. The aim of the present study was to determine the characteristics of the main abdominal organs as well as the vascular indexes of the abdominal aorta and renal arteries of crab-eating foxes (Cerdocyon thous) using mode B ultrasonography and Doppler ultrasonography, respectively. Ultrasonographic features of the main abdominal organs were described and slight differences were noticed between ultrasound imaging of abdominal organs of crab-eating foxes and other species. The bladder presented wall thickness of 12±0.01mm, with three defined layers. Both, the right and left kidneys presented corticomedullary ratio of 1:1 and similarly to the adrenals and the liver, they were homogeneous and hypoechoic compared to the spleen. The spleen was homogeneous and hyperechoic compared to the kidneys. The stomach presented 3 to 5 peristaltic movements per minute, wall thickness of 39±0.05mm and lumen and mucosa with hyperechoic and hypoechoic features, respectively. Small and large intestines presented 2 to 3 peristaltic movements per minute, wall thickness of 34±0.03mm and three defined layers with hyperechogenic (submucosa and serosa) and hypoechogenic (muscular) features. Ovaries of the female crab-eating fox were hypoechoic compared to the spleen and with heterogeneous parenchyma due to the presence of 2x2mm ovarian follicles. Prostates of the six males were regular and with a well defined boundary, with a homogeneous and hyperechoic parenchyma compared to the spleen. Vascular indexes of the abdominal aorta (PSV: 25.60±0.32cm/s; EDV: 6.96±1.68cm/s; PI: 1.15±0.07 e RI: 0.73±0.07) and right (PSV: 23.08±3.34cm/s; EDV: 9.33±2.36cm/s; PI: 1.01±0.65 e RI: 0.65±0.16) and left renal arteries (PSV: 23.74±3.94cm/s; EDV: 9.07±3.02cm/s; PI: 1.04±0.31 e RI: 0.64±0.10) were determined. Thus, conventional and Doppler ultrasonographic imaging provides basic information that can be used as reference for the species as well for other wild canids and it is a precise and non-invasive method that can be safely used to evaluate and diagnose abdominal injuries in these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resumo: A obesidade é o problema nutricional que mais acomete os cães e pode causar vários efeitos deletérios a saúde animal. No entanto, o efeito desta condição sobre a pressão arterial sistólica (PAS) em cães obesos é controverso. Os métodos indiretos de mensuração da PAS são os mais comumente utilizados na medicina veterinária para o diagnóstico da hipertensão sistêmica, por serem mais práticos e de fácil acesso. Não foram localizados na literatura estudos que tenham comparado os dois métodos para esta avaliação em cães obesos. Diante do exposto, o objetivo desse estudo foi avaliar a PAS em cães obesos, comparando os métodos indiretos de mensuração da pressão arterial, oscilométrico e doppler ultrassônico, a fim de verificar as diferenças nos valores obtidos, como também o método mais indicado para aferir a PAS em cães nesta condição. Foram avaliados 50 cães, incluindo 25 obesos com escore de condição corporal (ECC) médio de 8,42±0,50 e 25 cães com peso corporal ideal com ECC médio de 4,56±0,51. Os resultados revelaram valores superiores da PAS obtidos pelo método doppler (152±16mmHg) comparados ao oscilométrico (136±11mmHg). A análise de correspondência determinada por análise estatística multivariada demonstrou maior correspondência entre a condição corporal e o método de avaliação da PAS. Esses achados sugerem que o método indireto doppler pode aferir com mais precisão os valores de PAS em cães obesos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resumo: Meios de contraste iodado podem promover efeitos hemodinâmicos relacionados à vasoconstrição intrarrenal prolongada e redução da perfusão, predispondo à hipóxia e isquemia medular. Alterações de resistência vascular renal podem representar os primeiros sinais de mudança funcional desse órgão. A técnica Doppler pulsado é considerada acessível, não invasiva e permite avaliar a dinâmica vascular dos rins, por meio da aferição dos índices de resistividade (IR) e pulsatilidade (IP). Contudo, na espécie canina, a aquisição de traçados espectrais pode ser penosa devido às dificuldades de varredura e captação de sinal Doppler, sobretudo em relação ao rim direito, devido à sua localização dorsocranial na cavidade abdominal, o que prolonga substancialmente a realização do exame. O objetivo deste estudo é comprovar que a avaliação Doppler pulsado das artérias intrarrenais do rim esquerdo de cães representa a repercussão hemodinâmica renal da administração intravenosa de meios de contraste iodado não sendo necessária a realização do exame nos dois rins. Foram avaliados ambos os rins de seis cadelas adultas em quatro momentos distintos: antes da infusão intravenosa do contraste radiológico e após 1,5 horas, 24 horas e 48 horas, por meio da análise subjetiva da morfologia, ecogenicidade cortical e grau de perfusão renais e análise objetiva do comprimento, volume e resistência vascular intrarrenais (IR e IP). Os parâmetros avaliados ao modo B e Doppler dos rins direito e esquerdo não apresentaram diferenças estatisticamente significativas entre si em cada momento avaliado. Assim, constatou-se que o exame ultrassonográfico Doppler pulsado do rim esquerdo representou a repercussão hemodinâmica renal da aplicação intravenosa de meios de contraste iodado, desde que morfometria, morfologia, ecogenicidade cortical e perfusão de ambos os rins fossem consideradas semelhantes na abordagem ultrassonográfica inicial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this Master Thesis we discuss issues related to the measurement of the effective scattering surface, based on the Doppler Effect. Modeling of the detected signal was made. Narrowband signal filtering using low-frequency amplifier was observed. Parameters of the proposed horn antennas were studied; radar cross section charts for three different objects were received.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Forty-seven patients with unilateral obstructive calculi (12 males and 35 females) were submitted to 99mTc-diethylene triamine pentaacetic acid (DTPA) or 99mTc-dimercaptosuccinic acid (DMSA) scans for assessment of renal function. The scans revealed unilateral functional deficit in 68 and 66% of the patients, respectively. A calculus size of 1.1 to 2.0 cm was significantly associated with deficit detected by DTPA, but duration of obstruction and calculus localization were not. After relief of the obstruction, the mean percent renal function of the affected kidney was found to be significantly increased from 25 ± 12% to 29 ± 12% in DTPA and from 21 ± 15% to 24 ± 12% in DMSA. Initial Doppler ultrasonography performed in 35 patients detected an increased resistive index in 10 (29%). In the remaining patients with a normal resistive index, ureteral urinary jet was observed, indicating partial obstruction. The high frequency of renal function impairment detected by DTPA and of tubulointerstitial damage detected by DMSA as well as the slight amelioration of unilateral renal function after relief of obstruction suggest that scintigraphy assessment may help evaluate the unilateral percentage of renal function and monitor renal function recovery when it occurs. The presence of a urinary jet detected by Doppler ultrasonography further indicates the severity of obstruction and the recovery prognosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Borderline hypertension (BH) has been associated with an exaggerated blood pressure (BP) response during laboratory stressors. However, the incidence of target organ damage in this condition and its relation to BP hyperreactivity is an unsettled issue. Thus, we assessed the Doppler echocardiographic profile of a group of BH men (N = 36) according to office BP measurements with exaggerated BP in the cycloergometric test. A group of normotensive men (NT, N = 36) with a normal BP response during the cycloergometric test was used as control. To assess vascular function and reactivity, all subjects were submitted to the cold pressor test. Before Doppler echocardiography, the BP profile of all subjects was evaluated by 24-h ambulatory BP monitoring. All subjects from the NT group presented normal monitored levels of BP. In contrast, 19 subjects from the original BH group presented normal monitored BP levels and 17 presented elevated monitored BP levels. In the NT group all Doppler echocardiographic indexes were normal. All subjects from the original BH group presented normal left ventricular mass and geometrical pattern. However, in the subjects with elevated monitored BP levels, fractional shortening was greater, isovolumetric relaxation time longer, and early to late flow velocity ratio was reduced in relation to subjects from the original BH group with normal monitored BP levels (P<0.05). These subjects also presented an exaggerated BP response during the cold pressor test. These results support the notion of an integrated pattern of cardiac and vascular adaptation during the development of hypertension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although echocardiography has been used in rats, few studies have determined its efficacy for estimating myocardial infarct size. Our objective was to estimate the myocardial infarct size, and to evaluate anatomic and functional variables of the left ventricle. Myocardial infarction was produced in 43 female Wistar rats by ligature of the left coronary artery. Echocardiography was performed 5 weeks later to measure left ventricular diameter and transverse area (mean of 3 transverse planes), infarct size (percentage of the arc with infarct on 3 transverse planes), systolic function by the change in fractional area, and diastolic function by mitral inflow parameters. The histologic measurement of myocardial infarction size was similar to the echocardiographic method. Myocardial infarct size ranged from 4.8 to 66.6% when determined by histology and from 5 to 69.8% when determined by echocardiography, with good correlation (r = 0.88; P < 0.05; Pearson correlation coefficient). Left ventricular diameter and mean diastolic transverse area correlated with myocardial infarct size by histology (r = 0.57 and r = 0.78; P < 0.0005). The fractional area change ranged from 28.5 ± 5.6 (large-size myocardial infarction) to 53.1 ± 1.5% (control) and correlated with myocardial infarct size by echocardiography (r = -0.87; P < 0.00001) and histology (r = -0.78; P < 00001). The E/A wave ratio of mitral inflow velocity for animals with large-size myocardial infarction (5.6 ± 2.7) was significantly higher than for all others (control: 1.9 ± 0.1; small-size myocardial infarction: 1.9 ± 0.4; moderate-size myocardial infarction: 2.8 ± 2.3). There was good agreement between echocardiographic and histologic estimates of myocardial infarct size in rats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The severity of left ventricular (LV) dysfunction in rats with myocardial infarction (MI) varies widely. Because homogeneity in baseline parameters is essential for experimental investigations, a study was conducted to establish whether Doppler echocardiography (DE) could accurately identify animals with high LV end-diastolic pressure as a marker of LV dysfunction soon after MI. Direct measurements of LV end-diastolic pressure were made and DE was performed simultaneously 1 week after surgically induced MI (N = 16) or sham-operation (N = 17) in female Wistar rats (200 to 250 g). The ratio of peak early (E) to late (A) diastolic LV filling velocities and the ratio of E velocity to peak early (Em) diastolic myocardial velocity were the best predictors of high LV end-diastolic pressure (>12 mmHg) soon after MI. Cut-off values of 1.77 for the E/A ratio (P = 0.001) identified rats with elevated LV end-diastolic pressure with 90% sensitivity and 80% specificity. Cut-off values of 20.4 for the E/Em ratio (P = 0.0001) identified rats with elevated LV end-diastolic pressure with 81.8% sensitivity and 80% specificity. Moreover, E/A and E/Em ratios were the only echocardiographic parameters independently associated with LV end-diastolic pressure in multiple linear regression analysis. Therefore, DE identifies rats with high LV end-diastolic pressure soon after MI. These findings have implications for using serial DE in animal selection and in the assessment of their response to experimental therapies.